Tag: burner

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital 
average 10kgs per hour. 
with double(2) sets burner.

Equipment Technical Specifications

Model

YD-10

Feed Capacity

Typical 20 kgs per feed

Burning Rate

Typical 10 kgs Each hour

Burning Time Each Feed

2 hours

Voltage

220V

Fuel

Diesel Petroleum

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

5.4-12.6 Kgs/Hour

External Dimensions

100 x 100 x 160cm (mainbody)

Internal Dimensions

50 x 50 x 80cm(Main Chamber)

Waste combustion chamber

200Liters

Article Combustion Chamber

100Liters

Oil Tank Capacity

50 Liters

Door Opening

35 x 35cm

Chimney

3.0M

Gross Weight

1000kgs

Chamber Material

Refractory Concrete

Max.

126,000Kcal/Hr.

Operation Technical Specifications

Chamber fever

Chamber Anti-Rate

8000C -10000C

Residency time

13500C

0.5 Sec.

Burning efficiency

>98%

Waste Lower Calorific Power

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Ability of destruction in weight: 60 Kg/h.

It should be in a position to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes generated by hospitals, private clinics, labs, institutes, etc…

Design Specification: Forms A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the discharge of smoke and fine dust, (Smokeless) throughout the loadings.

It should be able to decrease the volume of wastes from 98%.

It should be in a position to hold emission in the next burn with gas residence of not less than 2 seconds.

The incineration must be completely free of visible smoke in addition to offensive odours.

The reduced volt electricity (L.C.P) of this waste will be 3,500 kcal/kg

The Temperatures of combustion: Minimum will be 850oC and maximum 1400oC

Post combustion: 1100oC.

The Internal diameter of the Chimney: Ø 400 and its elevation: 8 m

The Loudness of the combustion room: 1.200 L

The Dimension of this door for loading in cm: 70×70.

Burner operation should be Automatic On/Off

Gas: petrol

The supplier must provide  necessary information for the top of  this installment

This incinerator with”PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Totally tight door for your manual loading of waste.  The loading must be Manual, Batch Load 

* A burner of light which the usage is limited to the ignition of waste.

* Frontage of loading door seals gone on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulating material of the combustion chamber should be composed of refractory bricks, so using a high content of aluminum and insulates bricks so as to assure a minimum temperature on   the exterior sheet metal. Thickness : ≥100 mm

. Nature: 42% of Al203

Insulate in fibrous panels:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of light of waste, together with gas, regular mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

Incinerator with Ease of Jealousy in weight: 60 Kg/h.

Ability of destruction in weight: 60 Kg/h.

It should be able to work less 10 hours/day

This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, labs, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the discharge of smoke and dust that is fine, (Smokeless) during the loadings.

It should have the ability to reduce the quantity of wastes from 98%.

It should be able to hold emission in the next burn with gas residence of less than two seconds.

The incineration should be completely free of visible smoke as well as offensive odours.

The lower volt electricity (L.C.P) of the waste will be 3,500 kcal/kg

The Temperatures of combustionMinimum will be 850oC and maximum 1400oC

Post combustion: 1100oC.

The Inner diameter of the Chimney: Ø 400 and its elevation: 8 m

The Volume of the combustion chamber: 1.200 L

The Dimension of this doorway for loading cm: 70×70.

Burner operation should be Automatic On/Off

Gas: diesel

The provider must supply necessary information for the top of  this installment

This incinerator with”PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Totally tight doorway for the manual loading of waste.  The loading should be Manual, Batch Load 

* A burner of lighting that the use is restricted to the ignition of waste.

* Frontage of loading with door seals ended up on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulation of the combustion chamber should be made up of refractory bricks, so using a high content of aluminium and insulates bricks in order to guarantee a minimum temperature on   the exterior sheet metal.

* Composition of this refractory;

Refractory concrete:

. Nature: 42 percent of Al203

Insulate in fibrous panels:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max

a complete destruction of waste from various hospital services

Medical Waste Incinerator Purpose
For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement.
-Waste from health care activities
-Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. 
-Pathological waste, human fragments, blood, fetus, all body fluids, human tissues.
-Sculpts, needles, infusion sets, blades, glass
-Pharmaceutical waste. 
-Chemical waste laboratory reagents, disinfectants
-Expired drugs. 
-Low radiation radioactive element.
Medical waste incinerator: – Ecological Requirement
– No odor
-No fume
-Definitive treatment of waste
Medical waste incinerator: – Manufacturing Standards 
-UL,CE, ASME, ISA EURO emission standard 
1.Medical waste incinerator 
Construction – CS plate shells, FB reinforcement, cast refractory linings, 
                        Insulation and 14 gage aluminum jacket. 
Type of fuel – Oil fired (Diesel)
Burning Capacity – 250kg/hr and moisture up to 80%.
Duration -8-16/Continuous  
Average fuel consumption – Very little as much as possible
Control Type – PLC based operation
Operating Temperature – Primary chamber 800oc ± 50
                                     – Secondary Chamber 1050oc ± 50
Size of incinerator – Not more than 15mx7.20m
Chimney – Ø630x25meter height  and 7mm thick CS.
Combustion efficiency- 99%
Mode of waste handling- Semi-automatic via ram loader.
Mode of ash handling – Semi-automatic via grate and ash trolley.
Pollution control equipment- Dry settlement zone
Doors- 1-waste charging door in primary chamber
            1-clinker door in primary chamber
            1-ash trolley access door in primary chamber
            1-clean out door in secondary chamber
Burner – 2- ignition burner in primary chamber
               2- after burner in secondary chamber.
            Type- package mono block-fully automatic
Type of burner operation- modulation control
Forced draught fan- 1-primary air fan
                                1-secondary air fan
             
Fuel storage tank – Capacity- 2500liter above ground
                             – Material-6mm thick mild steel
                             – 2-diesel pump, gate valve, safety valve, strainer
                                Pipe, pressure gage, check valve, control board
                                Level indicator. Etc
Refractory/insulation thickness- not less than 225mm
Ram loader capacity- 0.75m3
Electrical supply- 380v/3ph/50 Hz
Finish and painting type- powder coated 
Audio/ visual alarm system- burner lockout, overload fault 
Electrical accessories- primary and secondary chamber temperature 
                                  Controller/indicator, auto controls, electrical 
                                  Control switches, push buttons, relays, contactors
                                  Thermocouples, burner sequence controllers,
                                  Timers, emergency stop and alarms.

a complete destruction of waste from various hospital services

Medical Waste Incinerator Purpose
For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement.
-Waste from health care activities
-Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. 
-Pathological waste, human fragments, blood, fetus, all body fluids, human tissues.
-Sculpts, needles, infusion sets, blades, glass
-Pharmaceutical waste. 
-Chemical waste laboratory reagents, disinfectants
-Expired drugs. 
-Low radiation radioactive element.
Medical waste incinerator: – Ecological Requirement
– No odor
-No fume
-Definitive treatment of waste
Medical waste incinerator: – Manufacturing Standards 
-UL,CE, ASME, ISA EURO emission standard 
1.Medical waste incinerator 
Construction – CS plate shells, FB reinforcement, cast refractory linings, 
                        Insulation and 14 gage aluminum jacket. 
Type of fuel – Oil fired (Diesel)
Burning Capacity – 250kg/hr and moisture up to 80%.
Duration -8-16/Continuous  
Average fuel consumption – Very little as much as possible
Control Type – PLC based operation
Operating Temperature – Primary chamber 800oc ± 50
                                     – Secondary Chamber 1050oc ± 50
Size of incinerator – Not more than 15mx7.20m
Chimney – Ø630x25meter height  and 7mm thick CS.
Combustion efficiency- 99%
Mode of waste handling- Semi-automatic via ram loader.
Mode of ash handling – Semi-automatic via grate and ash trolley.
Pollution control equipment- Dry settlement zone
Doors- 1-waste charging door in primary chamber
            1-clinker door in primary chamber
            1-ash trolley access door in primary chamber
            1-clean out door in secondary chamber
Burner – 2- ignition burner in primary chamber
               2- after burner in secondary chamber.
            Type- package mono block-fully automatic
Type of burner operation- modulation control
Forced draught fan- 1-primary air fan
                                1-secondary air fan
             
Fuel storage tank – Capacity- 2500liter above ground
                             – Material-6mm thick mild steel
                             – 2-diesel pump, gate valve, safety valve, strainer
                                Pipe, pressure gage, check valve, control board
                                Level indicator. Etc
Refractory/insulation thickness- not less than 225mm
Ram loader capacity- 0.75m3
Electrical supply- 380v/3ph/50 Hz
Finish and painting type- powder coated 
Audio/ visual alarm system- burner lockout, overload fault 
Electrical accessories- primary and secondary chamber temperature 
                                  Controller/indicator, auto controls, electrical 
                                  Control switches, push buttons, relays, contactors
                                  Thermocouples, burner sequence controllers,
                                  Timers, emergency stop and alarms.

Incinerator Operating period Anticipated daily period 8 hours

Operating period Anticipated daily period 8 hours
Maximum operating period 12hours
Chamber
Should be refractory lined to the following standards, hearth and lower section of chamber walls.
Hot face materials
Super dusty firebricks
Limiting continuous service limit 1500°c
Thickness 100mm
Thermal conductivity 1.3W/mk
Insulation
Calcium silicate
Limiting continuous service limit 1000°c
Thickness 25mm
Thermal conductivity 0.095w/mk
Chimney/stack
Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level
Ignition burners
Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor
Maximum rating :               at least 450kw/hour
Burner:                                  arranged for on/off operation
Maximum consumption :   at least 6litres per hour
Average consumption :      at least 3litres/hour
After burner
Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor.
Maximum rating :     At least 450kw/hour
Burner:                        arranged for on/off operation
Maximum consumption:     at least 9 litres/hour
Average consumption:         at least 4.5 litres /hour
Flue gas treatment
Should have particulate remover (scrubbers)
Electrical supply
Single phase 220/240v a.c,50/60hz
Documentation
Operation manual   2 sets
Service /maintenance manual 2 sets

Incinerator Operating period Anticipated daily period 8 hours

Operating period Anticipated daily period 8 hours
Maximum operating period 12hours
Chamber
Should be refractory lined to the following standards, hearth and lower section of chamber walls.
Hot face materials
Super dusty firebricks
Limiting continuous service limit 1500°c
Thickness 100mm
Thermal conductivity 1.3W/mk
Insulation
Calcium silicate
Limiting continuous service limit 1000°c
Thickness 25mm
Thermal conductivity 0.095w/mk
Chimney/stack
Should be manufactured from refractory lined mild steel or high quality air cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level
Ignition burners
Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor
Maximum rating :               at least 450kw/hour
Burner:                                  arranged for on/off operation
Maximum consumption :   at least 6litres per hour
Average consumption :      at least 3litres/hour
After burner
Fully packed oil type complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves fan and motor.
Maximum rating :     At least 450kw/hour
Burner:                        arranged for on/off operation
Maximum consumption:     at least 9 litres/hour
Average consumption:         at least 4.5 litres /hour
Flue gas treatment
Should have particulate remover (scrubbers)
Electrical supply
Single phase 220/240v a.c,50/60hz
Documentation
Operation manual   2 sets
Service /maintenance manual 2 sets

Medical Incineraotors chamber of post combustion

1.A chamber of post combustion of gases
A burner of combustion of gases,
A device of injection of air allowing a total re-combustion of gases,
A device of air inlet of cooling of waste gases,
A sheath of evacuation of the gases burnt,
Carcass in strong sheet steel with support of connection
Composition of the refractory;
Refractory concrete:
Thickness :>150mm
Nature: 65%% of Al203
Insulate in fibrous panels:
Thickness: >85mm
Nature: Calcium
Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, 
electromagnetic sluice gate of regulation and isolating valve.
A secondary injection of air to ensure perfect oxygen content.
2.A control box ensuring the complete cycle of combustion.
3.Fan:
Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of 
the automatic cycle.
4.Controls and regulations:
Control box watertight to dust, including:
A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post-combustion.
Electric box.
5.The de-ashing must be done in the bottom of the combustion chamber or the de-ashing should be automatic or manual batch de-ashing.
6.Process filtering system: scrubber to be mentioned as optional
7.Emission standards compliance: BS 3316 or equivalent standard
8.Capacity to treat plastic: not less than 40% by weight
9.CE manufacturing compliance: BS EN 746-2-1997