hiclover

Sudan Medical waste Treatment Scheme

•    A burn rate of 25 – 30kg/hr.
•    Consists of two chambers to ensure significant reduction of emissions and be capable of temperatures in the range of 800-1000˚c.
•    Incinerator must be of a low maintenance design, be diesel fuelled and need no more than 15 amp 220-250 V power. KW consumption per hour should be stated.
(1)  What  are  main  differences  between  medical  incinerators:    YD-10C  and  TS10(PLC)?
(2)  After  combustion,  the  medical  waste  becomes  smoke?  Without  smell?  No  pollution?
(3)  What  should  we  do  to  release  the  smoke?    Prepare  a  pipe  to  direct  the  smoke  to  factory  outside?
(4)  Any  operation  guide  for  reference,  we  worry  that  it’s  difficult  to  operate?
•    The incinerator should also be able to run off a generator.
•    The incinerator should have option of tank and should use no more than 12L of diesel fuel per hour to burn 25- 30kg of waste.options for medical waste incineration for Kabul, Afghanistan
•    Design must be such to minimize risk to operators and have a simple start sequence to minimize operator training and skills
•    Solid waste reductions in the range of 90 – 97% should be routinely achieved.a central thermal treatment station in the city of Khartoum (9 million inhabitants) we started with two units of autoclave that treat up to 18 tons a day so far, and looking forward to add an incineration plant/s to serve for medical, pharmaceutical, and hazardous waste.

Planta de fabricación de quemadores

Características principales:

– – Quemador de variedad completa con incinerador Tiny Range ahorrado, incinerador Criterion a pequeña y gran escala

Incinerador general de residuos sólidos municipales, cremación de animales y mascotas,

Incinerador móvil en contenedores, Incinerador de desechos ambientales de alta eficiencia.
– Cámara de combustión simple, cámaras de combustión dobles, tres cámaras de combustión y
incineradores de residuos con cámaras de combustión múltiple.
– Soluciones de sistema para el medio ambiente de residuos médicos.
– Alta velocidad de combustión, de 5 kg a 1000 kg por hora.
– Nuevo diseño para el negocio de cremación de animales de compañía.

– HICLOVER, socio de confianza con años de experiencia.

WWW.HICLOVER.COM Incineradores de desechos Filtros de aire de rollo automático
Tecnología médica Co., Ltd. del trébol de Nanjing

Tel: +86-25-8461 0201

Móvil: + 86-13813931455 (whatsapp / wechat)
Sitio web: www.hiclover.com
Correo electrónico: [correo electrónico protegido]
Correo electrónico: [correo electrónico protegido]
Artículos / Modelo TS10 (PLC) TS20 (PLC) TS30 (PLC) TS50 (PLC) TS100 (PLC)
Tasa de quema (promedio) 10 kg / hora 20 kg / hora 30 kg / hora 50 kg / hora 100 kg / hora
Capacidad de alimentación (promedio) 20 kg 40 kg 60kg 100 kg 200 kilogramos
Modo de control SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA
Cámara de combustión 100L 210L 330L 560L 1200L
Dimensiones internas Los 50x50x40cm Los 65x65x50cm Los 75x75x60cm El 100x80x70cm El 120x100x100cm
Cámara secundaria 50L 110L 180L 280L 600L
Cámara de filtro de humo
Modo de alimentación Manual Manual Manual Manual Manual
Voltaje 220 V 220 V 220 V 220 V 220 V
Energía 0,5 Kw 0,5 Kw 0,5 Kw 0,7 kilovatios 0,7 kilovatios
Consumo de aceite (kg / hora) 5,4-12,6 7,8–16,3 10.2-20 12.1-24 14-28
Consumo de gas (m3 / hora) 6.2-11.4 8-15,7 9,8-20 9,9-26,1 10–32,2
Monitor de temperatura
Protección de temperatura
Tanque de aceite 100L 100L 100L 100L 200L
Puerta de alimentación Los 30x30cm Los 45x40cm Los 55x50cm Los 70x55cm Los 80x60cm
Chimenea 3 metros 3 metros 5 metros 5 metros 10 metros
Tipo de chimenea Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable
1er. Temperatura de la cámara 800 –1000 800 –1000 800 –1000 800 –1000 800 –1000
2do. Temperatura de la cámara 1000 -1200 1000 -1200 1000 -1200 1000 -1200 1000 -1200
Tiempo de residencia 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg.
Peso bruto 1500 kg 2200 kg 3000 kg 4500kg 6000 kg
Dimensiones externas El 140x90x120cm El 160x110x130cm El 175x120x140cm Los 230x130x155cm Los 260x150x180cm

Capacidad de combustión – – 400 kg / hora y tampoco debe ser mucho menos de 300 kg / hora. El tiempo óptimo de combustión debe ser 6 veces / día Tamaño exterior de la chimenea – – 300 a 400 mm Potencia del ventilador – – No debe exceder 1,1 kw Voltaje – – 220 Consumo de combustible – – No debe exceder los 14 kg / h Medida en ángulo de la puerta de alimentación (mm) – – No mucho menos de 500 mm Temperatura de incineración. (⁰ C) – – 800 o superior CO – – No debe exceder los 100 mg / m3SO2 – – No debe exceder los 400 mg / m3 HF – – (Fluoruro de hidrógeno) No debe exceder los 9.0 mg / m3NO2 – – No debe exceder los 500 mg / m3 Polvo de humo – – No debe superar los 100 mg / m3 Altura del quemador – – No mucho menos de 10 m sobre el nivel del suelo Garantía del fabricante – – No mucho menos de 1 año Enlace eléctrico – – Desde la caja de distribución más cercana utilizando televisión por cable eléctrico de 25 mm2, así como todos los enlaces y cableado relacionados

A MOBILE MEDICAL WASTE INCINERATORS

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)

Italy oil burner: 02 sets

Oil Tank: 150Liters

Mobile Trailer for Incinerator

















Model

YD-50C

Burning Rate (kgs/Hour)

Average 20-50 kgs/hour

Feed Capacity (kgs)

Average 80 kgs/feeding

Equipment Weight

2500 kgs(Incinerator)

Primary Chamber (Liters)

400

Secondary Chamber (Liters)

140

External Dimensions (cm)

180x160x200

Internal Dimensions (cm)

70x70x85

Oil Tank(Liters)

150

Door Opening (cm)

45×55

Chimney (M)

5

Chimney Type

Stainless Steel

Secondary Chamber

YES

Mix-Combustion Chamber

YES

Smoke Filter Chamber

YES

Combustion Fuel

Oil

Residency Time

2.0 Sec.

Temperature Monitoring

YES

1st. Chamber Temperature

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Small Scale Incinerators



Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER
Production Capacity:1000 Sets Per Year

Product Description

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Nanjing Clover Medical Technology Co., Ltd., local in Nanjing city, China. Buy pet cremation equipment, buy pet crematorium china, buy+incineration+china, buying poultry incinerators prices, c incinerators pet, calculating burn rate of an animal carcass, CLOVER is manufacturer of medical product, waste incinerator and other environmental protection equipment. The market network across over the territory of China and more than 30 countries throughout the world.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Afterburner Preheat Incinerator

PRIMARY CHAMBER

Heavy-duty steel casing

High quality refractory lining and insulation Large full size top load counterbalanced door
1 x oil/gas fired ignition burners operated on/off

SECONDARY CHAMBER

Heavy-duty steel casing

High quality refractory lining and insulation 2 second gas residence time
1 x oil/gas fired ignition burners operated on/off

CHIMNEY

Heavy-duty stainless steel casing

CONTROL PANEL

Control of primary and secondary burners Temperature Monitoring with 4 digit display Thermostat control device for burner (fuel saver) Timer control 0- 12 hours

Integral fan timer control

Technical Specifications

Fuel
Diesel

Capacity
900kg (1.35m³)

Burn Rate
150kg/h

Avg Ash Residue
3%

Avg Fuel Consumption p/hr
20ltr

Operation
Min. Operating Temperature    950°C
Max. Operating Temperature    1320°C
Residency Time in Secondary Chamber    2 Seconds
Temperature Monitoring    YES

ANCILLARIES

Operating and maintenance manuals Spares list

KEY FEATURES

•Afterburner Preheat

•Incineration temperatures in excess of 1300°C

•5mm steel casing and fully insulate

•Dense refractory concrete lining rated to 1600°C

Небольшой легкий медицинский инсинератор 1500 кг в комплекте

Incinerator Yd-20c



Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., medical incenerators in china, medical incenrators supplier, medical incerator in china, medical incerator manufacturers in china, medical incinator, 10kg/hour, suppliers, up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Company License No.,: 320105000138343 
Taxation Certificate No.: 320105571573734 
Export Business Certificate No.: 3201571573734

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree

GENERAL SPECIFICATIONS FOR INCINERATORS

Primary and secondary burners: Separate electrically spark-ignited primary burners and secondary burners with automatic control shall be used to achieve the specified temperature requirements in the primary and secondary chambers. The flames  of the primary and secondary burners shall not impinge on the incinerator walls or floor.
The primary combustion chamber must:

1.    Be accepted as the primary combustion zone.
2.    Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels.
Other combustion methods will be judged on merits.

3.    Ensure primary air supply is controlled efficiently

Ensure minimum exit temperature is not less than 850oC

Air supply: Air supply in the primary and secondary chamber should be regulated between 30%-80% and 170%- 120% of stoichiometric amount respectively. Suitable flow measurement devices shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan after accounting for the air supplied through burners.The secondary combustion chamber must:

1.    Be accepted as secondary combustion zone.
2.    Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel.

3.    Ensure secondary air supply is controlled efficiently.

4.    Ensure flame contact with all gases is achieved.

5.    Ensure residence time is not less than two (2) seconds.
6.    Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100oC.

7.    Ensure the oxygen content of the emitted gases is not less than 11%.
Ensure both primary and the combustion temperatures are maintained until all waste has been completely combusted

lnsulation: lnsulation to be used for masonry, reinforced concrete, or non-combustible material shall prevent damage to the foundation from excessive heat and shall be of a thickness to limit the outer casing to a maximum temperature of 66°C in an ambient temperature of 21°C when the incinerator is operating at full capacity.

Refractory: Refractory shall be #super duty# and heat-resistant to a minimum of 1100°C in the primary chamber and 1250°C in the secondary chamber. Refractory shall also be abrasion resistant in the prlmary chamber, constructed of plastic or castable type refractory, designed to prevent bulging and destruction due to heat stress, capable of supporting more than twice the hourly burning rate and preventing leakage of fluids, and with a minimum thickness of 11O mm for walls and hearths

Установка для сжигания медицинских отходов HICLOVER на складе (готовые и полуфабрикаты, а также новое производство)

Модель Емкость / скорость сжигания Для больничной койки № Тип топлива Кол-во Готов к отправке Новое производство Объем доставки Вес с упаковкой Адрес доставки
TS30 в среднем 30 кг в час В среднем 150 больничных коек Дизельное топливо 1 комплект 5 дней 20 комплектов / 2 недели 5 м3 3000 кг Шанхайский порт
TS50 в среднем 50 кг в час В среднем 250 больничных коек Дизельное топливо 1 комплект 7 дней 20 комплектов / 2 недели 7м3 4500 кг Шанхайский порт
TS100 в среднем 100 кг в час В среднем 500 больничных коек Дизельное топливо 1 комплект 7 дней 15 комплектов / 2 недели 10м3 6000 кг Шанхайский порт
TS150 в среднем 150 кг в час В среднем 750 больничных коек Дизельное топливо 5 комплектов 7 дней 15 комплектов / 2 недели 13м3 7500 кг Шанхайский порт
10 ярдов в среднем 10 кг в час В среднем 50 больничных коек Дизельное топливо 2 комплекта 7 дней 20 комплектов / 2 недели 3м3 1200 кг Шанхайский порт
YD20C в среднем 20 кг в час В среднем 100 больничных коек Дизельное топливо 2 комплекта 7 дней 20 комплектов / 2 недели 6м3 2000 кг Шанхайский порт
YD50C в среднем 50 кг в час В среднем 250 больничных коек Дизельное топливо 2 комплекта 7 дней 20 комплектов / 2 недели 7м3 2300 кг Шанхайский порт
30 ярдов в среднем 30 кг в час В среднем 150 больничных коек Дизельное топливо 1 комплект 5 дней 20 комплектов / 2 недели 5м3 2300 кг Шанхайский порт
YD30 Малый в среднем 30 кг в час В среднем 150 больничных коек Дизельное топливо 2 комплекта 5 дней 20 комплектов / 2 недели 3м3 1500 кг Шанхайский порт
50 ярдов в среднем 50 кг в час В среднем 250 больничных коек Дизельное топливо 2 комплекта 5 дней 20 комплектов / 2 недели 8м3 4500 кг Шанхайский порт
100 ярдов в среднем 100 кг в час В среднем 500 больничных коек Дизельное топливо 1 комплект 10 дней 15 комплектов / 2 недели 13м3 6000 кг Шанхайский порт
150 ярдов в среднем 150 кг в час В среднем 750 больничных коек Дизельное топливо 1 комплект 10 дней 15 комплектов / 2 недели 17м3 7500 кг Шанхайский порт
300 ярдов в среднем 300 кг в час В среднем 1500 больничных коек Дизельное топливо 10 комплектов / 2 недели 20м3 9000 кг Шанхайский порт
500 ярдов в среднем 500 кг в час В среднем 2500 койко-мест Дизельное топливо 5 комплектов / 2 недели 27м3 13000 кг Шанхайский порт
CA 50 Mobile в контейнерах в среднем 50 кг в час В среднем 250 больничных коек Дизельное топливо 2 комплекта 15 дней 10 комплектов / 2 недели 28м3 7000 кг Шанхайский порт
1. Информация Изменение частоты с высокой частотой, только для справки.
2. Цена как официальное предложение, технические детали и коммерческие условия.

HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-29

Incinerator YD-100 for Iraq

 There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several construction sites and all fuel type is diesel oil.

 

Items/Model YD-100
Burning Rate (kgs/Hour) 100 kgs/Hr.
Feed Capacity (kgs) 200 kgs
Equipment Weight 5300 kgs
Primary Chamber (Liters) 1200
Secondary Chamber (Liters) 500
External Dimensions (cm) 220x180x360
Internal Dimensions (cm) 130x100x90
Oil Tank(Liters) 300
Door Opening (cm) 55 x 80
Chimney (M) 10
Chimney Type Stainless Steel
Secondary Chamber  YES
Mix-Combustion Chamber YES
Smoke Filter Chamber YES
Combustion Fuel Oil/Gas
Residency Time 2.0 Sec.
Temperature Monitoring YES
1st. Chmaber Temperature 800–1000
2nd. Chmaber Temperature 1000-1200
Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.