Tag: fuel

islands incinerators

Application : four islands in Croatia

Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day
Burning temperature – over 12000C
Two chambers – minimum
Emissions – dioxin and heavy metaly – better then Kyoto protocol
Emission – monitoring system
Waste unloiding – directly from waste track to incinerator
Burn Rate(Average kgs/hr)
 25 kg
 
primary chamber
 800 degree
 
secondary chamber
 1000 degree
 
chimney
 standard
 
shredder
 separately
 
Autoclave or microwaves
 separately
 
temperature monitor
 attached outside of machine
operating
 Fuel and electric
 
–          Toxic and dangerous wastes,  
–          Medical pharmaceutical and hospitable liquids  Wastes
–          Domestic garbage  
–          Electric and electronic wastes
–          Industrial wastes
–          In General, all type of wastes and garbages
1) working now in new order for Nigeria though our company for Yd-300 x 2 units , this is a job in hand in our customer located in dubai
2) the customer also want also to buy a fuel bulk storage tank  to be for 3 days continuous operation so we hope also you can manufacture it
so please give me the best price for fuel bulk storage tank  to be for 3 days continuous operation for YD-300
3) installation must be in the site in Nigeria by your company ,as i know your price rate which you sent to be before
4) what is the best price CIF Nigeria in lagos sea port as i have only price for cif dubai
5) 150 pcs Waste Containers (820 L) fully compatible with the incinerator and clinical waste container washing system.  please send me the price and catalog for this item
6) also they need Automatic Clinical Waste Container Washing System complete in every respect and fully compatible with containers price and catalog
7) 2 units 1.5 tonne Fork Lift  ( if you know good price and quality  company in china)
8) 1 unit Clinical Waste Container Vehicles complete in every respect and fully compatible with containers.
9) Spare Parts For 2 Years Operation & Maintenance  for YD-300 and for the above machines
10) all parts , pipe work electrical work and civil work for incinerator must be provided and material must be quoted
The highest temperature that the filter bag can operate continuously is 260C.    In order to add a bag house using our filter products, 
you would need to add a water cooling tower or other method to reduce the inlet temperature at the baghouse to less than 260C.   
If you cannot lower the temperature below 260C, then we cannot utilize our membrane filter bags.  

islands incinerators

Application : four islands in Croatia

Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day
Burning temperature – over 12000C
Two chambers – minimum
Emissions – dioxin and heavy metaly – better then Kyoto protocol
Emission – monitoring system
Waste unloiding – directly from waste track to incinerator
Burn Rate(Average kgs/hr)
 25 kg
 
primary chamber
 800 degree
 
secondary chamber
 1000 degree
 
chimney
 standard
 
shredder
 separately
 
Autoclave or microwaves
 separately
 
temperature monitor
 attached outside of machine
operating
 Fuel and electric
 
–          Toxic and dangerous wastes,  
–          Medical pharmaceutical and hospitable liquids  Wastes
–          Domestic garbage  
–          Electric and electronic wastes
–          Industrial wastes
–          In General, all type of wastes and garbages
1) working now in new order for Nigeria though our company for Yd-300 x 2 units , this is a job in hand in our customer located in dubai
2) the customer also want also to buy a fuel bulk storage tank  to be for 3 days continuous operation so we hope also you can manufacture it
so please give me the best price for fuel bulk storage tank  to be for 3 days continuous operation for YD-300
3) installation must be in the site in Nigeria by your company ,as i know your price rate which you sent to be before
4) what is the best price CIF Nigeria in lagos sea port as i have only price for cif dubai
5) 150 pcs Waste Containers (820 L) fully compatible with the incinerator and clinical waste container washing system.  please send me the price and catalog for this item
6) also they need Automatic Clinical Waste Container Washing System complete in every respect and fully compatible with containers price and catalog
7) 2 units 1.5 tonne Fork Lift  ( if you know good price and quality  company in china)
8) 1 unit Clinical Waste Container Vehicles complete in every respect and fully compatible with containers.
9) Spare Parts For 2 Years Operation & Maintenance  for YD-300 and for the above machines
10) all parts , pipe work electrical work and civil work for incinerator must be provided and material must be quoted
The highest temperature that the filter bag can operate continuously is 260C.    In order to add a bag house using our filter products, 
you would need to add a water cooling tower or other method to reduce the inlet temperature at the baghouse to less than 260C.   
If you cannot lower the temperature below 260C, then we cannot utilize our membrane filter bags.  

a complete destruction of waste from various hospital services

Medical Waste Incinerator Purpose
For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement.
-Waste from health care activities
-Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. 
-Pathological waste, human fragments, blood, fetus, all body fluids, human tissues.
-Sculpts, needles, infusion sets, blades, glass
-Pharmaceutical waste. 
-Chemical waste laboratory reagents, disinfectants
-Expired drugs. 
-Low radiation radioactive element.
Medical waste incinerator: – Ecological Requirement
– No odor
-No fume
-Definitive treatment of waste
Medical waste incinerator: – Manufacturing Standards 
-UL,CE, ASME, ISA EURO emission standard 
1.Medical waste incinerator 
Construction – CS plate shells, FB reinforcement, cast refractory linings, 
                        Insulation and 14 gage aluminum jacket. 
Type of fuel – Oil fired (Diesel)
Burning Capacity – 250kg/hr and moisture up to 80%.
Duration -8-16/Continuous  
Average fuel consumption – Very little as much as possible
Control Type – PLC based operation
Operating Temperature – Primary chamber 800oc ± 50
                                     – Secondary Chamber 1050oc ± 50
Size of incinerator – Not more than 15mx7.20m
Chimney – Ø630x25meter height  and 7mm thick CS.
Combustion efficiency- 99%
Mode of waste handling- Semi-automatic via ram loader.
Mode of ash handling – Semi-automatic via grate and ash trolley.
Pollution control equipment- Dry settlement zone
Doors- 1-waste charging door in primary chamber
            1-clinker door in primary chamber
            1-ash trolley access door in primary chamber
            1-clean out door in secondary chamber
Burner – 2- ignition burner in primary chamber
               2- after burner in secondary chamber.
            Type- package mono block-fully automatic
Type of burner operation- modulation control
Forced draught fan- 1-primary air fan
                                1-secondary air fan
             
Fuel storage tank – Capacity- 2500liter above ground
                             – Material-6mm thick mild steel
                             – 2-diesel pump, gate valve, safety valve, strainer
                                Pipe, pressure gage, check valve, control board
                                Level indicator. Etc
Refractory/insulation thickness- not less than 225mm
Ram loader capacity- 0.75m3
Electrical supply- 380v/3ph/50 Hz
Finish and painting type- powder coated 
Audio/ visual alarm system- burner lockout, overload fault 
Electrical accessories- primary and secondary chamber temperature 
                                  Controller/indicator, auto controls, electrical 
                                  Control switches, push buttons, relays, contactors
                                  Thermocouples, burner sequence controllers,
                                  Timers, emergency stop and alarms.

a complete destruction of waste from various hospital services

Medical Waste Incinerator Purpose
For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement.
-Waste from health care activities
-Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. 
-Pathological waste, human fragments, blood, fetus, all body fluids, human tissues.
-Sculpts, needles, infusion sets, blades, glass
-Pharmaceutical waste. 
-Chemical waste laboratory reagents, disinfectants
-Expired drugs. 
-Low radiation radioactive element.
Medical waste incinerator: – Ecological Requirement
– No odor
-No fume
-Definitive treatment of waste
Medical waste incinerator: – Manufacturing Standards 
-UL,CE, ASME, ISA EURO emission standard 
1.Medical waste incinerator 
Construction – CS plate shells, FB reinforcement, cast refractory linings, 
                        Insulation and 14 gage aluminum jacket. 
Type of fuel – Oil fired (Diesel)
Burning Capacity – 250kg/hr and moisture up to 80%.
Duration -8-16/Continuous  
Average fuel consumption – Very little as much as possible
Control Type – PLC based operation
Operating Temperature – Primary chamber 800oc ± 50
                                     – Secondary Chamber 1050oc ± 50
Size of incinerator – Not more than 15mx7.20m
Chimney – Ø630x25meter height  and 7mm thick CS.
Combustion efficiency- 99%
Mode of waste handling- Semi-automatic via ram loader.
Mode of ash handling – Semi-automatic via grate and ash trolley.
Pollution control equipment- Dry settlement zone
Doors- 1-waste charging door in primary chamber
            1-clinker door in primary chamber
            1-ash trolley access door in primary chamber
            1-clean out door in secondary chamber
Burner – 2- ignition burner in primary chamber
               2- after burner in secondary chamber.
            Type- package mono block-fully automatic
Type of burner operation- modulation control
Forced draught fan- 1-primary air fan
                                1-secondary air fan
             
Fuel storage tank – Capacity- 2500liter above ground
                             – Material-6mm thick mild steel
                             – 2-diesel pump, gate valve, safety valve, strainer
                                Pipe, pressure gage, check valve, control board
                                Level indicator. Etc
Refractory/insulation thickness- not less than 225mm
Ram loader capacity- 0.75m3
Electrical supply- 380v/3ph/50 Hz
Finish and painting type- powder coated 
Audio/ visual alarm system- burner lockout, overload fault 
Electrical accessories- primary and secondary chamber temperature 
                                  Controller/indicator, auto controls, electrical 
                                  Control switches, push buttons, relays, contactors
                                  Thermocouples, burner sequence controllers,
                                  Timers, emergency stop and alarms.

300 kg incinerator

300 kg incinerator

300 kg incinerator is the model YD-300, oil or gas fuel. the primary chamber is 220 x 110 x 100cm, means 2400 Liters.

Model YD-300
 Burning Rate 300 kgs/hour
Feed Capacity 500 kgs
Primary Combustion Chamber 2400 Liters
Secondary Combustion Chamber 1200 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 1.48Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 26–48.1 kg/hour
Gas Consumption (Natural Gas) 16.1–48.8 m3/hour
Internal Dimensions 220 x 110 x 100cm (primary chamber)
External Dimensions 260 x 220 x 420cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 500 Liters
Door Opening 90 x 110cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 8300 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal
Items Specification
Model YD-300
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney: 10 Meter
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel): 500Liters