Tag: mobile

Poultry Incinerators

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:nanjing clover
Origin:Clover

Product Description

Our company is interested to purchase waste incinerator. Please contact us price information and shipping and shipment detail. 

Samuel  Managing director  The National Depatment of Health with 3 sets of 50Kg/Hr Medical Waste Incinerators. Since the tender closes on the 22 of November we would love to submit our bidding and would ask you to kindly supply us the best price for 3 sets of 50kg/hr Medical Waste Incinerator. All additional plc temperature controller incinerator, mobile animal incinerators, mobile batch load incinerators, mobile cremation, mobile cremation oven, specialized spec will be forwarded to you once we’ve you feedback. Your price to include ocean freight(CIF) into Port Moresby, Papua New Guinea. 

We are searching for a single sludge incinerator, to burn less than 10 KG/ hours, can you estimate for us, urgent one incinerator to perform this, additional question is whether this device is created in China? .  SOLID WASTE INCINERATOR 

1.5 MMBtu / hr waste combustion, providing 200-250 lb/hr (90-114 kg/hr) 

Processing capability for mixed waste streams with an average gross 

HHV of 5500-8500 BTU/lb 

Batch Operation: Approx. 1.9 yb3 (1.45 m3) each 4-6 hour operation cycle 

Intermittent Feed (w/optional loader):. 9 yd3/hr (. 7 m3/hr) around 8 hrs/day 

Specifications: Length overall -9′-6″ (2896 mm) batch system w/o loader 

18′-6″ (5639mm) w/optional loader system Width overall -7′-6″ (2820mm) 

Height (w/o stack) -10′-0″ (3048mm) Approx. Weight – 14, 000 lbs. (6364 kg) w/oLoader

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

mobile Verbrennungsanlage

  1. Benzin: Diesel
  1. Verbrauch: 8-10 Liter / Stunde
  1. Kapazität: zur Einäscherung (Aas und Beute) 350-400 kg / Stunde
  1. Temperatur: 900-1350 ° C.
  1. Betriebstemperatur: -30 ~ 40 ° C.
  1. Gewicht der Verbrennungsanlage: 1800-2000 kg
  1. Volumen: 0,70-0,80 m / Würfel
  1. Außenabmessung: 1,4-1,6 * 1,0-1,15 m (L * W)

Eine Verbrennungsanlage stellt eine vollständige Lösung für das Problem der Entsorgung aller Arten von Krankenhausabfällen dar. Der flüssige Kraftstoff

ist Diesel. Die Verbrennungsanlage sollte den Umweltstandards entsprechen. Erwartete technische Daten

Die Verbrennungsanlage muss vollständig in sich geschlossen sein. rostfreie Verbrennungsanlagen

Stahl mit einer Zerstörungsrate von 15 kg pro Stunde. Bactch Last von 10-15kg

Abfall und Durchschnittstemperatur von 8500 Grad c.

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max

mobile incinerator

mobile incinerator

mobile incinerator is Double Combustion Chamber Containerized Mobile Incinerator. Containerized waste incinerator is our latest design for market. This incinerator is build in ISO container before leave factory. After customer received container, install the chimney and connect with electric power and setup oil tank, that’s all. Now, the burning capacity can be 30 kgs/50kgs/100kgs per hour for ISO 20’feet container. This moveable/mobile incinerator can be move by truck to any site by local customer.

This kind of incinerator is good choice for different end-customer site, Service personnel can move to there and service at local site. It is also best service type for family pet cremation service and other emergency status.

Double Combustion Chamber

The incinerator design with primary combustion chamber, secondary combustion chamber(post combustion) and dry scrubber optional. This design will reduce black smoke, burn completely and Environmentally Friendly.

Free Installation

The incinerator mounted already in the container, complete with fuel system, electric system and the control case fixed already. Fix chimney and connect electric will be ready for operation.

Mobile Incinerator

Waste Incinerator Mounted in ISO 20′ or 40′ Container. It’s moveable with truck to anywhere or emergency requirement.