Tag: weight

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Ability of destruction in weight: 60 Kg/h.

It should be in a position to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes generated by hospitals, private clinics, labs, institutes, etc…

Design Specification: Forms A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the discharge of smoke and fine dust, (Smokeless) throughout the loadings.

It should be able to decrease the volume of wastes from 98%.

It should be in a position to hold emission in the next burn with gas residence of not less than 2 seconds.

The incineration must be completely free of visible smoke in addition to offensive odours.

The reduced volt electricity (L.C.P) of this waste will be 3,500 kcal/kg

The Temperatures of combustion: Minimum will be 850oC and maximum 1400oC

Post combustion: 1100oC.

The Internal diameter of the Chimney: Ø 400 and its elevation: 8 m

The Loudness of the combustion room: 1.200 L

The Dimension of this door for loading in cm: 70×70.

Burner operation should be Automatic On/Off

Gas: petrol

The supplier must provide  necessary information for the top of  this installment

This incinerator with”PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Totally tight door for your manual loading of waste.  The loading must be Manual, Batch Load 

* A burner of light which the usage is limited to the ignition of waste.

* Frontage of loading door seals gone on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulating material of the combustion chamber should be composed of refractory bricks, so using a high content of aluminum and insulates bricks so as to assure a minimum temperature on   the exterior sheet metal. Thickness : ≥100 mm

. Nature: 42% of Al203

Insulate in fibrous panels:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of light of waste, together with gas, regular mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

Incinerator with Ease of Jealousy in weight: 60 Kg/h.

Ability of destruction in weight: 60 Kg/h.

It should be able to work less 10 hours/day

This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, labs, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the discharge of smoke and dust that is fine, (Smokeless) during the loadings.

It should have the ability to reduce the quantity of wastes from 98%.

It should be able to hold emission in the next burn with gas residence of less than two seconds.

The incineration should be completely free of visible smoke as well as offensive odours.

The lower volt electricity (L.C.P) of the waste will be 3,500 kcal/kg

The Temperatures of combustionMinimum will be 850oC and maximum 1400oC

Post combustion: 1100oC.

The Inner diameter of the Chimney: Ø 400 and its elevation: 8 m

The Volume of the combustion chamber: 1.200 L

The Dimension of this doorway for loading cm: 70×70.

Burner operation should be Automatic On/Off

Gas: diesel

The provider must supply necessary information for the top of  this installment

This incinerator with”PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Totally tight doorway for the manual loading of waste.  The loading should be Manual, Batch Load 

* A burner of lighting that the use is restricted to the ignition of waste.

* Frontage of loading with door seals ended up on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulation of the combustion chamber should be made up of refractory bricks, so using a high content of aluminium and insulates bricks in order to guarantee a minimum temperature on   the exterior sheet metal.

* Composition of this refractory;

Refractory concrete:

. Nature: 42 percent of Al203

Insulate in fibrous panels:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Capacity of destruction in weight: 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification : Types A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.

It should be able to reduce the volume of wastes by 98%.

It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg

The Temperatures of combustion: Minimum will be 850oC and max 1400oC

Post combustion: >1100oC.

The Internal diameter of the Chimney: Ø 400 and its height: 8 m

The Volume of the combustion chamber: 1.200 L

The Dimension of the door for loading in cm: 70×70.

Burner operation should be Automatic On/Off

Fuel : diesel

The supplier must provide  necessary information for the best of  the installation

This incinerator with “PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load 

* A burner of lighting which the use is limited to the ignition of waste.

* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory;

Refractory concrete :

. Thickness : ≥100 mm

. Nature: 42% of Al203

Insulate in fibrous panels :

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Capacity of destruction in weight: 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification : Types A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.

It should be able to reduce the volume of wastes by 98%.

It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg

The Temperatures of combustion: Minimum will be 850oC and max 1400oC

Post combustion: >1100oC.

The Internal diameter of the Chimney: Ø 400 and its height: 8 m

The Volume of the combustion chamber: 1.200 L

The Dimension of the door for loading in cm: 70×70.

Burner operation should be Automatic On/Off

Fuel : diesel

The supplier must provide  necessary information for the best of  the installation

This incinerator with “PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load 

* A burner of lighting which the use is limited to the ignition of waste.

* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory;

Refractory concrete :

. Thickness : ≥100 mm

. Nature: 42% of Al203

Insulate in fibrous panels :

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

FFP2 Breathing mask machine

平面口罩机参数:

Semi-Automatic Mask Machine

Power supply: 3.3KW mono phase

Mask Size: 175mm*80-100mm (two or three layers)

Nonwoven (GMS): 10-50g

Capacity: 120 to 150pcs/min

Dimension(L*W*H):3800mm*500mm*1400mm

Net Weight: about 1000kg

 

焊接机参数:

Welding Machine

Capacity: 5 to 10pcs/min

Power supply: 8.5KW mono phase

Compressed Air connection: 0.5 to 0.7Mpa

Dimension(L*W*H): 900mm*650mm*1380mm

Net weight: approx. 50kg

 

KN95口罩机参数:

N95 Mask Machine

Capacity: 130 to 160pcs/min

Dimension(L*W*H): 1037*855*1780

Power Supply 15.3kw mono phase

Net Weight: approx.: 1500kg


Zhangjiagang Tengxiang Machinery Co., Ltd.
Mobile: 0086-13962221749(whatsapp)
Wechat: chncheumg

Face Mask Machine for Coronavirus Disease COVID-19



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-06

portable incinerator

portable incinerator

portable incinerator means a small incinerator so end user can move it to other place. we made portable incinerator and the weight under 2000 kgs, the burning rate from 5kgs per hour to 20kgs per hour. all designed with three combustion chamber and two oil or gas burner. this kind of portable incinerator is cheap cost for small waste out put.

Items/Model YD-10C YD-20C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs
Equipment Weight 2100 kgs 2100 kgs
Primary Chamber (Liters) 200 200
Secondary Chamber (Liters) 140 140
External Dimensions (cm) 170x140x160 170x140x160
Internal Dimensions (cm) 55x55x65 55x55x65
Oil Tank(Liters) 50 100
Door Opening (cm) 38 x 48 38 x 48
Chimney (M) 5 5
Chimney Type Stainless Steel Stainless Steel
Secondary Chamber YES YES
Mix-Combustion Chamber YES YES
Smoke Filter Chamber YES YES
Combustion Fuel Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃