PLC Incinerator (TS50 PLC)

Basic Info.

Model NO.:TS50 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:Clover
Packing:Full Container
Standard:50 kg per hour
Origin:China
Production Capacity:1500 Units/Year

Product Description

Items/Model TS50(PLC)
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital 
average 10kgs per hour. 
with double(2) sets burner.

Equipment Technical Specifications

Model

YD-10

Feed Capacity

Typical 20 kgs per feed

Burning Rate

Typical 10 kgs Each hour

Burning Time Each Feed

2 hours

Voltage

220V

Fuel

Diesel Petroleum

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

5.4-12.6 Kgs/Hour

External Dimensions

100 x 100 x 160cm (mainbody)

Internal Dimensions

50 x 50 x 80cm(Main Chamber)

Waste combustion chamber

200Liters

Article Combustion Chamber

100Liters

Oil Tank Capacity

50 Liters

Door Opening

35 x 35cm

Chimney

3.0M

Gross Weight

1000kgs

Chamber Material

Refractory Concrete

Max.

126,000Kcal/Hr.

Operation Technical Specifications

Chamber fever

Chamber Anti-Rate

8000C -10000C

Residency time

13500C

0.5 Sec.

Burning efficiency

>98%

Waste Lower Calorific Power

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview


This model is small-scale waste incineration equipment for small waste output. 

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate
Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people
— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital 
average 10kgs per hour. 
with double(2) sets burner.

Equipment Technical Specifications

Model

YD-10

Feed Capacity

Average 20 kgs per feed

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

5.4-12.6 Kgs/Hour

External Dimensions

100 x 100 x 160cm (mainbody)

Internal Dimensions

50 x 50 x 80cm(Primary Chamber)

Waste combustion chamber

200Liters

Post Combustion Chamber

100Liters

Oil Tank Capacity

50 Liters

Door Opening

35 x 35cm

Chimney

3.0M

Gross Weight

1000kgs

Chamber Material

Refractory Concrete

Max. Heat Value

126,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

13500C

Residency time

0.5 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-08

animal incinerators for sale

animal incinerators for sale

animal incinerators for sale, movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal.

Model A900
Function movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal.
Burning Rate Average 30 kgs/hour
Feed Capacity Average 80 kgs/feed
Primary Combustion Chamber 900 Liters
Secondary Combustion Chamber 300 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 0.7Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) Average 31 kg/hour
Gas Consumption (Natural Gas) Average 27 m3/hour
Internal Dimensions 120 x 90 x 85 cm (primary chamber)
External Dimensions 200 x 160 x 310 cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 60 x 80cm
Chimney Length 5.0 Meters
Chimney Type Stainless Steel
Combustion Chamber Material Refractory Concrete Cement(No Brick)
Equipment Gross Weight 6000 kgs
Operation Technical Specifications
Primary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal