Tag: chamber

Incinerator Medical Waste Maximum Capacity

Basic Info.

 

Model NO.:medical waste incinerator manufacturers
Export Markets:Global

Product Description

 

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China.

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed rate, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  * New Design for pet animal cremation business.  * One year guarantee on incinerator and parts in stock. 

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital 
average 10kgs per hour. 
with double(2) sets burner.

Equipment Technical Specifications

Model

YD-10

Feed Capacity

Typical 20 kgs per feed

Burning Rate

Typical 10 kgs Each hour

Burning Time Each Feed

2 hours

Voltage

220V

Fuel

Diesel Petroleum

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

5.4-12.6 Kgs/Hour

External Dimensions

100 x 100 x 160cm (mainbody)

Internal Dimensions

50 x 50 x 80cm(Main Chamber)

Waste combustion chamber

200Liters

Article Combustion Chamber

100Liters

Oil Tank Capacity

50 Liters

Door Opening

35 x 35cm

Chimney

3.0M

Gross Weight

1000kgs

Chamber Material

Refractory Concrete

Max.

126,000Kcal/Hr.

Operation Technical Specifications

Chamber fever

Chamber Anti-Rate

8000C -10000C

Residency time

13500C

0.5 Sec.

Burning efficiency

>98%

Waste Lower Calorific Power

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Incinerator Main Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial 
trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, 
eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal 
for military and civil camps and remote locations where infrastructure is scarce.
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with 
other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid 
cross-contamination risk and to keep waste treatment costs at acceptable level.

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Technology Co.,Ltd..

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day 
Control: Built-in data recording
Operating temperature: Incinerator 
/Primary Combustion Chamber
Primary Chamber: 900 – 1200 0C


Type: horizontal/vertical
Temperature:  1200- 1300 oC
Residence time of gases : >2 seconds
Ash Residue: <5% of original waste size
Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash
Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity
Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc 
Auxiliary device: Fuel cut-off device
Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      
Chimney (Stack):
Type: Vertical type
height:>7 meter’
Material: Fireproof cast, stainless steel
OUTPUT: 
GAS- SMOKELESS,ODORLESS 
ASH -Max <5% of original waste size
Reduction of Pollutant gas SO2, HCL, HF and line particulate
Emission standard:
WHO/ European
Test report for emission testing provided?
Heat exchange mode: Automatic

Type: Constant loading, Top LoadingCapacity/Burn Speed per hour: 250 -300 kg/hr Substance:External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks Using Aluminium lining, resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day 
Control: Built-in data recording
Operating temperature: Incinerator 
/Primary Combustion Chamber
Primary Chamber: 900 – 1200 0C


Type: horizontal/vertical
Temperature:  1200- 1300 oC
Residence time of gases : >2 seconds
Ash Residue: <5% of original waste size
Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash
Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity
Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc 
Auxiliary device: Fuel cut-off device
Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      
Chimney (Stack):
Type: Vertical type
height:>7 meter’
Material: Fireproof cast, stainless steel
OUTPUT: 
GAS- SMOKELESS,ODORLESS 
ASH -Max <5% of original waste size
Reduction of Pollutant gas SO2, HCL, HF and line particulate
Emission standard:
WHO/ European
Test report for emission testing provided?
Heat exchange mode: Automatic

Type: Constant loading, Top LoadingCapacity/Burn rate per hour: 250 -300 kg/hr Substance:External- 3 layers Internal Liner:  a fire proof material of pre-fired refractory bricks Using Aluminium Liner resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

Incinerator with Ease of Jealousy in weight: 60 Kg/h.

Ability of destruction in weight: 60 Kg/h.

It should be able to work less 10 hours/day

This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, labs, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the discharge of smoke and dust that is fine, (Smokeless) during the loadings.

It should have the ability to reduce the quantity of wastes from 98%.

It should be able to hold emission in the next burn with gas residence of less than two seconds.

The incineration should be completely free of visible smoke as well as offensive odours.

The lower volt electricity (L.C.P) of the waste will be 3,500 kcal/kg

The Temperatures of combustionMinimum will be 850oC and maximum 1400oC

Post combustion: 1100oC.

The Inner diameter of the Chimney: Ø 400 and its elevation: 8 m

The Volume of the combustion chamber: 1.200 L

The Dimension of this doorway for loading cm: 70×70.

Burner operation should be Automatic On/Off

Gas: diesel

The provider must supply necessary information for the top of  this installment

This incinerator with”PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Totally tight doorway for the manual loading of waste.  The loading should be Manual, Batch Load 

* A burner of lighting that the use is restricted to the ignition of waste.

* Frontage of loading with door seals ended up on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulation of the combustion chamber should be made up of refractory bricks, so using a high content of aluminium and insulates bricks in order to guarantee a minimum temperature on   the exterior sheet metal.

* Composition of this refractory;

Refractory concrete:

. Nature: 42 percent of Al203

Insulate in fibrous panels:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

One chamber incinerator

One (MAIN) chamber only, with two doors
Doors with hinges at the center
LPG combustible mainly
After burner and chimney don′t change
MAIN Chamber dimensions [LxWxH]: 2.2m x 4.5m x 2.8m, so we can put two containers within the MAIN chamber
Ok per your comment, refractory concrete and fire brick inside the chamber; feed door with refractory concrete
Burning Rate:47.5–50kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary chamber:2sec
Residue ash post 100kg:Max 3.8kg
1)      This type is suitable for medical waste, but how many kilos can be put in the incinerator in one time
2)      Q: Operation and maintenance costs, these costs are based on?? What if we use it every day??
3)      How many hertz do we need for this type of incinerator
4)      Where is the oil tank in the incinerator?
5)      Is it possible to build in not the standard accessories but the high proof accessories?
6)      What are the costs when shipment is to Surinam/South America
7)      How will the inicinerator be delivered? Partly installated or do we have to install it completly? 
And in addition, the other models with less burn rate capacity as TS100(PLC); TS50(PLC); TS30(PLC); TS20(PLC) and TS10(PLC), interests also our company.
So, would you give also Proforma Invoices of these models in CIF Prices to Port of Abidjan.
 
Furthermore, as the Incinerators have to be installed at nationwide, there are always great power cuts in our country.
So, we would like to know if you can supply each Incinerator with a diesel engine (generator) which power is adapted to the power of the Incinerator unit?

One chamber incinerator

One (MAIN) chamber only, with two doors
Doors with hinges at the center
LPG combustible mainly
After burner and chimney don′t change
MAIN Chamber dimensions [LxWxH]: 2.2m x 4.5m x 2.8m, so we can put two containers within the MAIN chamber
Ok per your comment, refractory concrete and fire brick inside the chamber; feed door with refractory concrete
Burning Rate:47.5–50kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary chamber:2sec
Residue ash post 100kg:Max 3.8kg
1)      This type is suitable for medical waste, but how many kilos can be put in the incinerator in one time
2)      Q: Operation and maintenance costs, these costs are based on?? What if we use it every day??
3)      How many hertz do we need for this type of incinerator
4)      Where is the oil tank in the incinerator?
5)      Is it possible to build in not the standard accessories but the high proof accessories?
6)      What are the costs when shipment is to Surinam/South America
7)      How will the inicinerator be delivered? Partly installated or do we have to install it completly? 
And in addition, the other models with less burn rate capacity as TS100(PLC); TS50(PLC); TS30(PLC); TS20(PLC) and TS10(PLC), interests also our company.
So, would you give also Proforma Invoices of these models in CIF Prices to Port of Abidjan.
 
Furthermore, as the Incinerators have to be installed at nationwide, there are always great power cuts in our country.
So, we would like to know if you can supply each Incinerator with a diesel engine (generator) which power is adapted to the power of the Incinerator unit?

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max