hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day 
Control: Built-in data recording
Operating temperature: Incinerator 
/Primary Combustion Chamber
Primary Chamber: 900 – 1200 0C


Type: horizontal/vertical
Temperature:  1200- 1300 oC
Residence time of gases : >2 seconds
Ash Residue: <5% of original waste size
Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash
Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity
Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc 
Auxiliary device: Fuel cut-off device
Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      
Chimney (Stack):
Type: Vertical type
height:>7 meter’
Material: Fireproof cast, stainless steel
OUTPUT: 
GAS- SMOKELESS,ODORLESS 
ASH -Max <5% of original waste size
Reduction of Pollutant gas SO2, HCL, HF and line particulate
Emission standard:
WHO/ European
Test report for emission testing provided?
Heat exchange mode: Automatic

Type: Constant loading, Top LoadingCapacity/Burn Speed per hour: 250 -300 kg/hr Substance:External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks Using Aluminium lining, resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber:

incinerador de animales china

Trituradora de residuos médicos

 Capacidad: Debe ser de 150 litros.

 Debe poder triturar hasta 100 litros de residuos tratados.

7

 La tecnología debe ser capaz de tratar los desechos hospitalarios, incluidos los objetos punzantes como agujas,

lancetas, bisturís y materiales blandos como vendajes.

 Debe hacer que los desechos sean irreconocibles.

Los siguientes documentos adjuntos deben suministrarse con el sistema de tratamiento y deben

estar disponible en el Sitio:

  1. Instrucciones de funcionamiento (incluida la descripción del proceso.
  2. Procedimientos de carga y mantenimiento.
  3. Procedimientos abreviados de operación y carga.
  4. ASTM International (ASTM):

C401 91 (2005) Clasificación estándar de refractarios moldeables de alúmina y silicato de alúmina

C612 04 Aislamiento térmico de paneles y bloques de fibra mineral

  1. Asociación Nacional de Protección contra Incendios (NFPA):

70 07 Código Eléctrico Nacional

82 04 Incineradores y sistemas y equipos de manipulación de residuos y ropa

  1. Underwriters Laboratories (UL):

50 07… Cajas para equipos eléctricos

PARTE 2 PRODUCTO

2.1 INSTALACIÓN DEL INCINERADOR

  1. El incinerador consistirá en un cambiador de carbonización de baja temperatura (cámara primaria) en el que se

Los componentes se convierten en gas por el calor que se produce a través de una combustión incompleta como resultado de una deficiencia.

de aire, y un reactor de gas (reactor térmico) en el que el gas se quema con un exceso controlado de aire.

Hazardous situation: Incinerators in K-P’s major hospitals from order

PESHAWAR:

Based on information gathered by the Environmental Protection Agency (EPA), 15 to 20 tons of hospital waste is made every day in the provincial capital alone. Nearly half of the total waste is recycled while the remainder is accumulated by the Peshawar Development Authority (PDA).

LRH

“To be truthful, we have one incinerator which is not in proper working condition and hardly disposes a quarter of the total waste generated,” said an official in Lady Reading Hospital while requesting anonymity. “But we have a new incinerator which will soon be functional.”

The officer, who didn’t know the specific figure of the waste created, said LRH has been one of the most popular hospitals across the nation. It has over 5,000 people (at least 3,000 in outpatient and 2,000 in accident and emergency departments) from across the province on a daily basis.

“The incinerator below process has some problems as some of its components are yet to be obtained,” said the official. “It also requires adequate gas–another significant issue –but we’re in touch with Sui Northern Gas Pipeline Limited (SNGPL).”

The LRH official added that the supply of gas to the hospital isn’t enough for sterilisation. He said the hospital government is connected with SNGPL authorities and the issue will soon be solved.

HMC

Hayatabad Medical Complex (HMC) Chief Executive Dr Mumtaz Marwat said the incinerator in HMC is out of sequence but it will burn some waste. “The left is gathered from the PDA and the hospital administration has approved Rs0.4million for a new incinerator, which will soon be installed”

“Together with all the solid waste created by KTH, we also recycle waste that comes from some private hospitals at University Town,” said Roghani.

The EPA has already sent a written notice to the health directorate, asking it to correctly dispose of medical waste as stated beneath Hospital Waste Management Rules 2005. These say the duty of waste management is based solely with the magician that created it.

What occurs following

Actually if the incinerators at these hospitals have been repaired, the issue of unattended dump is very likely to persist. This is largely due to the tiny personal health centers which lack the fundamental knowledge and dispose of their waste as’municipal waste’. The ever-increasing amount of such centers is directly proportional to the waste created, making it a threat for the surroundings as at times that the waste is just left in a pile or buried to groundwater.

"Inceneritore modello YD-30 per Australia Melbourne"

Inceneritore modello YD-30 per cliente Australia Melbourne. Dall’anno 2011 al 2013, forniamo 02 diversi modelli per questo cliente, uno è il modello SYC-50 (ora aggiornato al modello TS50 PLC) e un modello YD-30. Entrambi i modelli sono del tipo a gas combustibile e questi inceneritori per l’attività di cremazione di animali domestici della famiglia locale.

Il modello YD dell’inceneritore di rifiuti sanitari è il nostro prodotto classico per il mercato. Tutte le serie includevano capacità di combustione di 10 kg all’ora, 30 kg all’ora, 50 kg all’ora, 100 kg all’ora, 150 kg all’ora, 300 kg all’ora, 500 kg all’ora. Fino ad ora, tutti i modelli vengono venduti in tutto il mondo e hanno un buon feedback dal cliente finale. L’inceneritore medico modello YD ha una camera di combustione multipla e uno scrubber a secco di base (camera del filtro del fumo) con un budget di progetto ragionevole. Per la richiesta di emissioni più pulite, accettiamo scrubber a umido su misura per inceneritore e questo sarà anche il nostro prossimo lavoro concentrandoci sulle emissioni tecniche.

Modello YD-30
Velocità di combustione 30 kg / ora
Capacità di alimentazione 60 kg
Camera di combustione Paimary 360 litri
Camera di combustione secondaria 200 litri
Camera di combustione della miscela
Camera filtro fumi
Modalità di alimentazione Manuale
Voltaggio 220V
Energia 0.59Kw
Tipo di carburante Gasolio / Gas naturale / GPL
Bruciatore Italia originale
Consumo di olio (gasolio) 10,2–19,8 kg / ora
Consumo di gas (gas naturale) 9,8–20 m3 / ora
Dimensioni interne 100 x 60 x 60 cm (camera dei genitori)
Dimensioni esterne 145 x 90 x 260 cm (senza camino)
Monitoraggio della temperatura
Capacità del serbatoio dell’olio (se olio combustibile) 200 litri
Apertura porta 48 x 60 cm
Lunghezza camino 5,0 metri
Tipo di camino Acciaio inossidabile
Peso lordo dell’attrezzatura 2300 kg
Specifiche tecniche di funzionamento
Temperatura minima della camera 800 ℃ –1000 ℃
Temperatura della camera secondaria 1000 ℃ -1200 ℃
Tempo di residenza 2,0 sec.
Efficienza di combustione > 98%
Spreco di potere calorifico inferiore 3000Kcal

Incinerator with Capacity of destruction in weight: 60 Kg/h.

Ability of destruction in weight: 60 Kg/h.

It should be in a position to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes generated by hospitals, private clinics, labs, institutes, etc…

Design Specification: Forms A, B, C, D, and E of medical waste 

“PYROLYTIC” combustion, by simply controlling the gasification of waste.

The incinerator must prevent the discharge of smoke and fine dust, (Smokeless) throughout the loadings.

It should be able to decrease the volume of wastes from 98%.

It should be in a position to hold emission in the next burn with gas residence of not less than 2 seconds.

The incineration must be completely free of visible smoke in addition to offensive odours.

The reduced volt electricity (L.C.P) of this waste will be 3,500 kcal/kg

The Temperatures of combustion: Minimum will be 850oC and maximum 1400oC

Post combustion: 1100oC.

The Internal diameter of the Chimney: Ø 400 and its elevation: 8 m

The Loudness of the combustion room: 1.200 L

The Dimension of this door for loading in cm: 70×70.

Burner operation should be Automatic On/Off

Gas: petrol

The supplier must provide  necessary information for the top of  this installment

This incinerator with”PYROLYTIC” combustion must have:

A combustion chamber of waste:

* Totally tight door for your manual loading of waste.  The loading must be Manual, Batch Load 

* A burner of light which the usage is limited to the ignition of waste.

* Frontage of loading door seals gone on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.

* The insulating material of the combustion chamber should be composed of refractory bricks, so using a high content of aluminum and insulates bricks so as to assure a minimum temperature on   the exterior sheet metal. Thickness : ≥100 mm

. Nature: 42% of Al203

Insulate in fibrous panels:

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of light of waste, together with gas, regular mono-bloc casting directing stirring flame, lighting and safety of digital ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.

. Thickness: ≥75 mm

Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 

Incinerador de 3 cámaras

Cámara primaria:
Carcasa de acero dulce de alta resistencia, revestimiento y aislamiento refractario de alta calidad 01 x quemadores de encendido de gas natural (automático) 01 x puntos de sensor de temperatura con ventiladores internos completos.
Cámara secundaria:
Carcasa de acero dulce de alta resistencia, revestimiento refractario de alta calidad y aislamiento. 01 quemadores de gas natural (automáticos) con 01 ventiladores internos completos. 02 Segundos tiempos de residencia del gas.
Tercera Cámara:
Carcasa de acero dulce de alta resistencia, revestimiento y aislamiento refractario de alta calidad. 01 quemadores de encendido a gas natural (automáticos) con ventiladores internos completos. 02 seg. Tiempo de residencia del gas.
Lavadora de gas de doble gripe integrada:

Los gases resultantes pasan a través del sistema de filtración de gas dual para una máxima emisión limpia. También está equipado con filtros de cadena.
Chimenea:
Carcasa de acero inoxidable de alta resistencia de 5 mm o más Carcasa de acero dulce.
Tapa de chimeneas / supresores de chispas.
Panel de control:
a.Monitorización de temperatura con pantalla de 4 dígitos.
b.Dispositivo de control de termostato para quemador (ahorro de combustible)
c. Control de temperatura 0-12 horas.
d. Control integral del temporizador del ventilador

Incinerador de 3 cámaras

Cámara primaria:
Carcasa de acero dulce de alta resistencia, revestimiento y aislamiento refractario de alta calidad 01 x quemadores de encendido de gas natural (automático) 01 x puntos de sensor de temperatura con ventiladores internos completos.
Cámara secundaria:
Carcasa de acero dulce de alta resistencia, revestimiento refractario de alta calidad y aislamiento. 01 quemadores de gas natural (automáticos) con 01 ventiladores internos completos. 02 Segundos tiempos de residencia del gas.
Tercera Cámara:
Carcasa de acero dulce de alta resistencia, revestimiento y aislamiento refractario de alta calidad. 01 quemadores de encendido a gas natural (automáticos) con ventiladores internos completos. 02 seg. Tiempo de residencia del gas.
Lavadora de gas de doble gripe integrada:

Los gases resultantes pasan a través del sistema de filtración de gas dual para una máxima emisión limpia. También está equipado con filtros de cadena.
Chimenea:
Carcasa de acero inoxidable de alta resistencia de 5 mm o más Carcasa de acero dulce.
Tapa de chimeneas / supresores de chispas.
Panel de control:
a.Monitorización de temperatura con pantalla de 4 dígitos.
b.Dispositivo de control de termostato para quemador (ahorro de combustible)
c. Control de temperatura 0-12 horas.
d. Control integral del temporizador del ventilador

"Consegna del modello YD-100 in Iraq"

Ci sono 03 serie di modelli YD-100 consegnati in Iraq tra il 2013 e il 2014. L’uso dell’inceneritore per diversi cantieri locali e tutto il tipo di combustibile è gasolio.

L’inceneritore modello YD-100 è una macchina di incenerimento di media scala per molti usi diversi: per un letto di malato di ospedale medio inferiore a 500 unità, per tutti gli animali domestici di piccola o grande taglia (come l’Alaskan Malamute Dog), per l’incenerimento dei rifiuti solidi urbani della comunità, ecc. il volume della camera di combustione primaria è 1200Liters (1.2m3) e utilizza bruciatore a gasolio o gas naturale originale dall’Italia.

Modello YD-100
Velocità di combustione 100 kg / ora
Capacità di alimentazione 200 kg
Camera di combustione Paimary 1200 litri
Camera di combustione secondaria 500 litri
Camera di combustione della miscela
Camera filtro fumi
Modalità di alimentazione Manuale
Voltaggio 220 V / 380 V.
Energia 0.9Kw
Tipo di carburante Gasolio / Gas naturale / GPL
Bruciatore Italia originale
Consumo di olio (gasolio) 14–28 kg / ora
Consumo di gas (gas naturale) 10–32,2 m3 / ora
Dimensioni interne 130 x 100 x 90 cm (camera dei genitori)
Dimensioni esterne 220 x 180 x 360 cm (senza camino)
Monitoraggio della temperatura
Capacità del serbatoio dell’olio (se olio combustibile) 300 litri
Apertura porta 55 x 80 cm
Lunghezza camino 10.0 metri
Tipo di camino Acciaio inossidabile
Peso lordo dell’attrezzatura 4300 kg
Specifiche tecniche di funzionamento
Temperatura minima della camera 800 ℃ –1000 ℃
Temperatura della camera secondaria 1000 ℃ -1200 ℃
Tempo di residenza 2,0 sec.
Efficienza di combustione > 98%
Spreco di potere calorifico inferiore 3000Kcal

"Modello YD-150 per Casablanca, Marocco"

Questo cliente da Casablanca, Marocco, Nord Africa. abbiamo consegnato al cliente nell’anno 2014 e il cliente era soddisfatto del modello YD-150. Il contenitore di spedizione è un contenitore pieno di 1 × 20 piedi.
Tutti i nostri inceneritori utilizzano camini in acciaio inossidabile, non in acciaio.
Tutti i nostri inceneritori hanno almeno due camere di combustione, non una camera singola.
Tutti i bruciatori a combustibile dall’Italia realizzati con marchio famoso, migliore qualità.

Modello YD-150
Velocità di combustione 150 kg / ora
Capacità di alimentazione 300 kg
Camera di combustione Paimary 1500 litri
Camera di combustione secondaria 500 litri
Camera di combustione della miscela
Camera filtro fumi
Modalità di alimentazione Manuale
Voltaggio 220 V / 380 V.
Energia 1.03Kw
Tipo di carburante Gasolio / Gas naturale / GPL
Bruciatore Italia originale
Consumo di olio (gasolio) 17–36 kg / ora
Consumo di gas (gas naturale) 11–36,7 m3 / ora
Dimensioni interne 150 x 100 x 96 cm (camera dei genitori)
Dimensioni esterne 240 x 170 x 380 cm (senza camino)
Monitoraggio della temperatura
Capacità del serbatoio dell’olio (se olio combustibile) 300 litri
Apertura porta 59 x 81 cm
Lunghezza camino 10.0 metri
Tipo di camino Acciaio inossidabile
Peso lordo dell’attrezzatura 7000 kg
Specifiche tecniche di funzionamento
Temperatura minima della camera 800 ℃ –1000 ℃
Temperatura della camera secondaria 1000 ℃ -1200 ℃
Tempo di residenza 2,0 sec.
Efficienza di combustione > 98%
Spreco di potere calorifico inferiore 3000Kcal

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day 
Control: Built-in data recording
Operating temperature: Incinerator 
/Primary Combustion Chamber
Primary Chamber: 900 – 1200 0C


Type: horizontal/vertical
Temperature:  1200- 1300 oC
Residence time of gases : >2 seconds
Ash Residue: <5% of original waste size
Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash
Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity
Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc 
Auxiliary device: Fuel cut-off device
Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      
Chimney (Stack):
Type: Vertical type
height:>7 meter’
Material: Fireproof cast, stainless steel
OUTPUT: 
GAS- SMOKELESS,ODORLESS 
ASH -Max <5% of original waste size
Reduction of Pollutant gas SO2, HCL, HF and line particulate
Emission standard:
WHO/ European
Test report for emission testing provided?
Heat exchange mode: Automatic

Type: Constant loading, Top LoadingCapacity/Burn rate per hour: 250 -300 kg/hr Substance:External- 3 layers Internal Liner:  a fire proof material of pre-fired refractory bricks Using Aluminium Liner resistant to corrosive Gas or Waste and Also to thermal shockSecondary Combustion Chamber: