Tag: incinerator

Design standard Multiple chamber incinerator

Waste type organics domestical  waste
Calorific value of waste 9,25 MJ/kg
Ash content 20.80 %
Density 291 Kg/m3
Waste quantity (kg per hr) 12,500
Total Heat input (Gcal/hr) 23.71
organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms
Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse  Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length 
Width 
Height 
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rake

Incinerator china maker



incinerator china manufacturer

HICLOVER is currently incinerator china manufacturer, developing brand for environmental protection area, and market share with most of Africa, Middle East, Southeast Asia states as part of North America, Europe land. We are trusted associate for governmental organizations, non-profit organizations, international contractors, logistics organizations, army, pet cremation business owners, etc.. We have export experience more than 40 nations, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

Design standard Multiple chamber incinerator

Waste type organics domestical  waste
Calorific value of waste 9,25 MJ/kg
Ash content 20.80 %
Density 291 Kg/m3
Waste quantity (kg per hr) 12,500
Total Heat input (Gcal/hr) 23.71
organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms
Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse  Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length 
Width 
Height 
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rake

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr
Type of Design: Double Chambered
Mode of Heating: Heating Elements 
Primary Combustion Chamber
 Waste Charging Door: Provided with refractory lining with sealing gaskets 
Ash Removed Door: Provided with refractory lining with sealing gaskets 
Outer Body MOC: Mild Steel, 5mm 
Primary Chamber: Stainless Steel 
Operating Temperature :800. ± 50◦C
 Insulation: Insulation Brick 
Heating Elements Type: Kanthal Al Grade
Power Consumption: 75 KW ( Initial Load )
 Electrical Supply :3 Phase 440 Volt 
Control Panel
 MOC: Mild Steel Power Coated
No. of Temp: Controllers : 2 Nos
 Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase.
I.D.Fan
Type: Centrifugal Type 
MOC: Mild Steel
 Capacity:2 HP/3Phase
 Make of Motor: Kirloskar /Havells/Crompton
Combustion Air Fan
Type: Centrifugal Type 
Capacity: 1HP/3Phase
 Make of Motor: Kirloskar /Havells/Crompton
Stack:
Type:  Wire Supported 
MOC:  Mild Steel of ISstd
Height :3 Meters or more
*** Primary combustion chamber & secondary combustion chamber
*** Smoke filter chamber(dry scrubber)
*** stainless steel chimney
*** PLC auto. control
*** Italy made oil or gas burner(diesel oil/natural gas/lpg)
*** temperature display and control
*** high temperature firebrick,etc

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-10

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr
Type of Design: Double Chambered
Mode of Heating: Heating Elements 
Primary Combustion Chamber
 Waste Charging Door: Provided with refractory lining with sealing gaskets 
Ash Removed Door: Provided with refractory lining with sealing gaskets 
Outer Body MOC: Mild Steel, 5mm 
Primary Chamber: Stainless Steel 
Operating Temperature :800. ± 50◦C
 Insulation: Insulation Brick 
Heating Elements Type: Kanthal Al Grade
Power Consumption: 75 KW ( Initial Load )
 Electrical Supply :3 Phase 440 Volt 
Control Panel
 MOC: Mild Steel Power Coated
No. of Temp: Controllers : 2 Nos
 Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase.
I.D.Fan
Type: Centrifugal Type 
MOC: Mild Steel
 Capacity:2 HP/3Phase
 Make of Motor: Kirloskar /Havells/Crompton
Combustion Air Fan
Type: Centrifugal Type 
Capacity: 1HP/3Phase
 Make of Motor: Kirloskar /Havells/Crompton
Stack:
Type:  Wire Supported 
MOC:  Mild Steel of ISstd
Height :3 Meters or more

a complete destruction of waste from various hospital services

Medical Waste Incinerator Purpose
For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement.
-Waste from health care activities
-Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. 
-Pathological waste, human fragments, blood, fetus, all body fluids, human tissues.
-Sculpts, needles, infusion sets, blades, glass
-Pharmaceutical waste. 
-Chemical waste laboratory reagents, disinfectants
-Expired drugs. 
-Low radiation radioactive element.
Medical waste incinerator: – Ecological Requirement
– No odor
-No fume
-Definitive treatment of waste
Medical waste incinerator: – Manufacturing Standards 
-UL,CE, ASME, ISA EURO emission standard 
1.Medical waste incinerator 
Construction – CS plate shells, FB reinforcement, cast refractory linings, 
                        Insulation and 14 gage aluminum jacket. 
Type of fuel – Oil fired (Diesel)
Burning Capacity – 250kg/hr and moisture up to 80%.
Duration -8-16/Continuous  
Average fuel consumption – Very little as much as possible
Control Type – PLC based operation
Operating Temperature – Primary chamber 800oc ± 50
                                     – Secondary Chamber 1050oc ± 50
Size of incinerator – Not more than 15mx7.20m
Chimney – Ø630x25meter height  and 7mm thick CS.
Combustion efficiency- 99%
Mode of waste handling- Semi-automatic via ram loader.
Mode of ash handling – Semi-automatic via grate and ash trolley.
Pollution control equipment- Dry settlement zone
Doors- 1-waste charging door in primary chamber
            1-clinker door in primary chamber
            1-ash trolley access door in primary chamber
            1-clean out door in secondary chamber
Burner – 2- ignition burner in primary chamber
               2- after burner in secondary chamber.
            Type- package mono block-fully automatic
Type of burner operation- modulation control
Forced draught fan- 1-primary air fan
                                1-secondary air fan
             
Fuel storage tank – Capacity- 2500liter above ground
                             – Material-6mm thick mild steel
                             – 2-diesel pump, gate valve, safety valve, strainer
                                Pipe, pressure gage, check valve, control board
                                Level indicator. Etc
Refractory/insulation thickness- not less than 225mm
Ram loader capacity- 0.75m3
Electrical supply- 380v/3ph/50 Hz
Finish and painting type- powder coated 
Audio/ visual alarm system- burner lockout, overload fault 
Electrical accessories- primary and secondary chamber temperature 
                                  Controller/indicator, auto controls, electrical 
                                  Control switches, push buttons, relays, contactors
                                  Thermocouples, burner sequence controllers,
                                  Timers, emergency stop and alarms.

a complete destruction of waste from various hospital services

Medical Waste Incinerator Purpose
For a complete destruction of waste from various hospital services by heat treatment of high temperature in accordance with EU standard on emission requirement.
-Waste from health care activities
-Infections waste, laboratory cultures, waste form operation room isolations material in contact with infected patients, waste potentially being infected by pathogenic agents. 
-Pathological waste, human fragments, blood, fetus, all body fluids, human tissues.
-Sculpts, needles, infusion sets, blades, glass
-Pharmaceutical waste. 
-Chemical waste laboratory reagents, disinfectants
-Expired drugs. 
-Low radiation radioactive element.
Medical waste incinerator: – Ecological Requirement
– No odor
-No fume
-Definitive treatment of waste
Medical waste incinerator: – Manufacturing Standards 
-UL,CE, ASME, ISA EURO emission standard 
1.Medical waste incinerator 
Construction – CS plate shells, FB reinforcement, cast refractory linings, 
                        Insulation and 14 gage aluminum jacket. 
Type of fuel – Oil fired (Diesel)
Burning Capacity – 250kg/hr and moisture up to 80%.
Duration -8-16/Continuous  
Average fuel consumption – Very little as much as possible
Control Type – PLC based operation
Operating Temperature – Primary chamber 800oc ± 50
                                     – Secondary Chamber 1050oc ± 50
Size of incinerator – Not more than 15mx7.20m
Chimney – Ø630x25meter height  and 7mm thick CS.
Combustion efficiency- 99%
Mode of waste handling- Semi-automatic via ram loader.
Mode of ash handling – Semi-automatic via grate and ash trolley.
Pollution control equipment- Dry settlement zone
Doors- 1-waste charging door in primary chamber
            1-clinker door in primary chamber
            1-ash trolley access door in primary chamber
            1-clean out door in secondary chamber
Burner – 2- ignition burner in primary chamber
               2- after burner in secondary chamber.
            Type- package mono block-fully automatic
Type of burner operation- modulation control
Forced draught fan- 1-primary air fan
                                1-secondary air fan
             
Fuel storage tank – Capacity- 2500liter above ground
                             – Material-6mm thick mild steel
                             – 2-diesel pump, gate valve, safety valve, strainer
                                Pipe, pressure gage, check valve, control board
                                Level indicator. Etc
Refractory/insulation thickness- not less than 225mm
Ram loader capacity- 0.75m3
Electrical supply- 380v/3ph/50 Hz
Finish and painting type- powder coated 
Audio/ visual alarm system- burner lockout, overload fault 
Electrical accessories- primary and secondary chamber temperature 
                                  Controller/indicator, auto controls, electrical 
                                  Control switches, push buttons, relays, contactors
                                  Thermocouples, burner sequence controllers,
                                  Timers, emergency stop and alarms.

we supply incinerator installation demo for customer. Incinerator Installation and Commissioning Services: Generally, we proposal customer send engineers come to Clover to learn incinerator information, and the Training  cost is free. Technicians from CLOVER are available to supervise customer’s skilled staff for installation, commissioning, train customer’s technical and production staff and help the staff to produce qualified end product.

Zhangjiagang Tengxiang Machinery Co., Ltd.
Mobile: 0086-13962221749(whatsapp)
Wechat: chncheumg
Face Mask Machine for Coronavirus Disease COVID-19

平面口罩机参数:

Semi-Automatic Mask Machine

Power supply: 3.3KW mono phase

Mask Size: 175mm*80-100mm (two or three layers)

Nonwoven (GMS): 10-50g

Capacity: 120 to 150pcs/min

Dimension(L*W*H):3800mm*500mm*1400mm

Net Weight: about 1000kg

 

焊接机参数:

Welding Machine

Capacity: 5 to 10pcs/min

Power supply: 8.5KW mono phase

Compressed Air connection: 0.5 to 0.7Mpa

Dimension(L*W*H): 900mm*650mm*1380mm

Net weight: approx. 50kg

 

KN95口罩机参数:

N95 Mask Machine

Capacity: 130 to 160pcs/min

Dimension(L*W*H): 1037*855*1780

Power Supply 15.3kw mono phase

Net Weight: approx.: 1500kg



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-06