Tag: waste

wea are chinese incinerator manufacturers.  Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator manufacturer in China. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all models sale to all over the world and have good feedback from end-customer. The YD Model medical incinerator have multi-combustion chamber and basic dry scrubber (smoke filter chamber) with reasonable project budget. For the cleaner emission require, we accept custom made wet scrubber for incinerator and this will be also our next working by focusing on emission technical.

Double Combustion Chamber: All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly

Containerized Mobile Incinerator: The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck.

Family Pet Dog&Cat Cremation: Special design with movable platform, combustion chamber material and custom made for pets crematory business.

Installation and Commissioning: Clover’s engineers instal,train for most of the region and free-cost train in our factory.

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-21

Incinerator Primary Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial 
trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, 
eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal 
for military and civil camps and remote locations where infrastructure is scarce.
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with 
other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid 
cross-contamination risk and to keep waste treatment costs at acceptable level.

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

Incinerator Primary Combustion Chamber

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial 
trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, 
eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal 
for military and civil camps and remote locations where infrastructure is scarce.
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with 
other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid 
cross-contamination risk and to keep waste treatment costs at acceptable level.

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  

England’s Garbage Producing Danish heat

“They save on having to bury the waste and we save on the consumption of natural gas,” he explained.

READ MORE: Denmark pays for electricity

Environmental protection agency Miljøstyrelsen explained that last year up to 200,000 tonnes of non-hazardous waste from England was incinerated in Denmark — almost six percentage of the total volume of combustible material used.

by: http://cphpost.dk/news/englands-trash-generating-danish-heat.11398.html

Incinerators in Aalborg and Hjørring are also burning British trash.

“The heating we produce using the waste is cheaper than that which we could create with gas,” explained AVØ mind Tore Vedelsdal. “And the British are curious since they lack incinerators and pay heavy taxes on landfills.”

Good for the environment

Power in Denmark is increasingly being produced in plants burning waste imported from England. The custom is being called an economic and ecological blessing on either side of the equation.

The AVØ incinerator in Frederikshavn creates heating and electricity to the area by burning trash from England.

“It’s mainly construction waste like bits of wood, cardboard and plastic in Manchester,” AVØ operations manager Orla Frederiksen told DR Nyheder. “I guess we have 600 tonnes here which provide a fantastic combustible mixture we could then become district heating and electricity.”

Good for your bottom line

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview


This model is small-scale waste incineration equipment for small waste output. 

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate
Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people
— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital 
average 10kgs per hour. 
with double(2) sets burner.

Equipment Technical Specifications

Model

YD-10

Feed Capacity

Average 20 kgs per feed

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

5.4-12.6 Kgs/Hour

External Dimensions

100 x 100 x 160cm (mainbody)

Internal Dimensions

50 x 50 x 80cm(Primary Chamber)

Waste combustion chamber

200Liters

Post Combustion Chamber

100Liters

Oil Tank Capacity

50 Liters

Door Opening

35 x 35cm

Chimney

3.0M

Gross Weight

1000kgs

Chamber Material

Refractory Concrete

Max. Heat Value

126,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

13500C

Residency time

0.5 Sec.

Burning efficiency

98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-08

HICLOVER Top Feeding Door Waste Incinerators

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke



parts of an incinerator
physical method of disposing hazardous chemical waste
portable incinerators types
proper ways of waste disposal in the community
questionnaire to ask about incinerators for collection of data

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

< /font>

 

2020-08-07

Items/Model

TS1000

Picture

 

Principle

Waste Incineration Treatment

Burn Rate

Average 1000 kg/hour

Feed Capacity

Average 3000kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

4800Liter

Internal Dimensions

400*120*100 cm

Secondary Chamber

1000Liter

Feed Mode

Manual/Forklift

Voltage

220V/380V

Power

5.0Kw

Oil Consumption (kg/hour)

Average 67(DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

800Liter

Feed Door

300x120cm(Electric Opening)

Chimney

6Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

18000kg

External Dimensions

700x220x320cm(without chimney)


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-11-04

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-07-21