Tag: primary

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview


This model is small-scale waste incineration equipment for small waste output. 

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate
Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people
— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

300 kg incinerator

300 kg incinerator

300 kg incinerator is the model YD-300, oil or gas fuel. the primary chamber is 220 x 110 x 100cm, means 2400 Liters.

Model YD-300
 Burning Rate 300 kgs/hour
Feed Capacity 500 kgs
Primary Combustion Chamber 2400 Liters
Secondary Combustion Chamber 1200 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 1.48Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 26–48.1 kg/hour
Gas Consumption (Natural Gas) 16.1–48.8 m3/hour
Internal Dimensions 220 x 110 x 100cm (primary chamber)
External Dimensions 260 x 220 x 420cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 500 Liters
Door Opening 90 x 110cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 8300 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal
Items Specification
Model YD-300
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney: 10 Meter
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel): 500Liters

animal incinerators for sale

animal incinerators for sale

animal incinerators for sale, movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal.

Model A900
Function movable feeding door, Flame Checking hole, waste oil collect, balance combustion for pet animal.
Burning Rate Average 30 kgs/hour
Feed Capacity Average 80 kgs/feed
Primary Combustion Chamber 900 Liters
Secondary Combustion Chamber 300 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 0.7Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) Average 31 kg/hour
Gas Consumption (Natural Gas) Average 27 m3/hour
Internal Dimensions 120 x 90 x 85 cm (primary chamber)
External Dimensions 200 x 160 x 310 cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 60 x 80cm
Chimney Length 5.0 Meters
Chimney Type Stainless Steel
Combustion Chamber Material Refractory Concrete Cement(No Brick)
Equipment Gross Weight 6000 kgs
Operation Technical Specifications
Primary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

double chamber incinerator

double chamber incinerator

double chamber incinerator designed for completed combustion for waste, the first(primary) combustion chamber burn the waste directly by oil or gas burner. the secondary combustion chamber burn the smoke from the first(primary) combustion chamber. high temperature combustion will completed destroy waste and made the smoke cleaner.

double chamber incinerator fit with two burner in each chamber, but for some large incinerator, we made two or three burner for the first(primary) combustion chamber, this will made the waste burn more completed and also made high burning rate.

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃