MUNICIPAL SOLID WASTE INCINERATORS

a specific type to use at a crematorium. Something that allows specifically for ash collection etc.cremation option to the deceased’s family. Is this product suitable, are ashes easily collected etc. a cremator, for pet clinic, could you introduce and all detail of sales, tax, environtment.-Plastic. 500Kg/hr and to be used maximum 6 times, is this means it will provide only 3 tons per day? Noting that project documents requires 10 tons/day
Plastic bottle-
-Rags & oiled
Glass bottles and aluminum-
-Oils
Fat-
Filter, tires, belts
-Chemicals, paint
Household waste-
Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories, complying with 01015 par. 5.16.1
LOT
2.0

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks, control panels and all accessories , complying with 01015 par. 5.16.2
MUNICIPAL SOLID WASTE INCINERATORS

Municipal waste incinerator quantities and capacities shall be designed for 24-hour 7-day-a-week continuous operation.

Incinerators shall be capable of processing both wet and dry material and operating on either diesel fuel, JP-8 fuel,

or waste oil; see Plumbing for fuel storage system requirements. The following shall be provided as a minimum:

Reinforced concrete mounting foundations, feed or charging hoppers (or loaders), primary combustion chambers

with ash cleanout doors, secondary combustion chambers with ash cleanout doors, cyclone air filters (or separators),

and forced air exhaust stacks (or chimneys).

The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic

charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system using either

air or water shall be provided.

Primary combustion chamber shall be either the rotary- or stationary fixed-hearth (or kiln) type incinerator. Burner

and combustion air controls shall be fully automatic comprising of, as a minimum, electronic ignition and all

necessary interlocks and safety devices to provide safe operation. The chamber and burner shall be designed to

maintain a minimum combustion temperature of at least 700 to 870 C (1300 to 1600 F), but shall not to exceed 980

C (1800 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

pit where cooled by water and removed by conveyor.

Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to

oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be fully automatic

comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe

operation. The chamber and burner shall be designed to maintain a minimum combustion temperature of at least

930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as

a minimum, the direct manual removal into a dry

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

particles.

5.16.2 MEDICAL WASTE INCINERATORS

Medical waste incinerators shall be specifically designed by the manufacturer to dispose of all medical wastes. All units shall be designed for 8 hours

per day of continuous operation and be rated in quantity per hour (i.e. kg/hr or lbs/hr).

Incinerator loading or charging of medical waste shall be batched-fed manually.

Primary combustion chamber shall be the stationary fixed-hearth (or kiln), multiple-chamber, retort type or larger

capacity rotary-hearth (or kiln) type. Burner and combustion air controls shall be fully automatic comprising of, as a

minimum, electronic ignition and all necessary interlocks and safety devices to provide safe operation. The

chamber and burner shall be designed to maintain a minimum combustion temperature of at least 760 to 870 C

(1400 to 1600 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench

pit where cooled by water and removed by conveyor.

Secondary combustion chamber shall be a solid-walled and -floored, horizontal, refractory-lined cylinder type

incinerator designed to oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be

fully automatic comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to

provide safe operation. The chamber and burner shall be designed to maintain a minimum combustion temperature

of at least 930 to 1200 C (1700 to 2200 F) with a minimum gas residence (or dwell) time of 2.0 seconds. The ashremoval

system shall consist of, as a minimum, the direct manual removal into a dry collection hopper.

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

particles.

5.16.3 INCINERATOR STACKS (OR CHIMNEYS)

Stack size shall be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air type and

completely self-supporting and unattached to nearby structures. As a minimum, stack heights shall minimize

downwash of stack emissions due to aerodynamic influences from nearby structures and be calculated in accordance

with DoD 4715.05-G, Overseas Environmental Baseline Guidance Document. Stacks shall be provided with

corrosion-resistant steel weather caps.”

Diesel/LPG/LNG burning vital burning chamber/primary combustion burner


Key burning
Diesel/LPG/LNG burning vital burning chamber/primary burning area
Second burning
Residence time in the second chamber not less than 2 secs
Both essential along with the second temperature levels maintained up until all the waste has in fact been entirely stired up
Chimney
Chimney with a very little height of 4 meters over ground level
Minimum leave velocity of the discharges very little less than 10 metres/second
Temperature level Cautions
Visible and/or distinctive alarm to warn the vehicle driver when the second temperature level drops to listed below the needed temperature level
General
Control box that can be separated as well as mounted on different stand a minimum of 1.5 meters from burner at around 1.6 meter

heightItem 1
Burner style A

Melt Rate 65kg/h minimum

Weight (kg), please show:

Secondary Chamber

Gas Retention Time – – – – 2 Secs

– Fuel – Diesel/LPG/LNG, please show

Power Supply for Control Box – 220V-240V 50Hz solitary phase

Minimum running temperature level 850 ° C, please recommend

One year Spare Components Prepare for total maintainability

10m Tube Pipe, recommend size

I000 Litre Gas Tank + Pipeline System, show quantity

Added smokeshaft expansion, show elevation

Solution guarantee, suggest no of years

Thing 2
Incinerator version C.
Burn Rate 250kg/h minimum

Weight (kg) please showProgram.
2nd Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V 50Hz solitary stage
. Minimum running temperature level 920 ° C, please recommend.
One year Spare Elements Bundle for full maintainability.
10m Hose pipe Pipe, indicate size.
I000 Litre Gas Tank + Pipe System, indicate quantity.
Bonus smokeshaft expansion, suggest elevation.
Guarantee, indicate no of years

Warmth Waste Incinerator

Capability at least (4000) kg/day (( Day= 16 Working Humans Resources))

Capability at the very least (4000) kg/day (( Day= 24 Working Hrs))

With the following qualities:

* Automatic feeder as initial part of the unit.

* Automatic ash/ leftovers removal as preliminary part of the device.

* Water Injection System to manage the temperature > >

* Flue gas filtering system abiding by EU.
HTW Incinerator design D.
Burn Rate – – – – 150kg/hour minimum. Weight( kg), please indicate:.
Secondary Chamber.
Gas Retention Time 2 Seconds.
Gas Diesel/LPG/LNG, please program.
Power Supply for Control Box 220V-240V, solitary stage 50-60Hz.
Minimum running temperature level 1200 ° C, please program

One year Spare Components Prepare for full maintainability

10m Tube Pipe, show size.
1000 Litre Gas Storage Tank + Pipeline System, suggest quantity.
Bonus chimney extension, suggest height.
Mobile Burner

Item 5.
Mobile Heater version E

Melt Cost 50kg/h minimum

Weight (kg), please program:

Second Chamber

Gas Retention Time – – – – 2 Seconds –

– Gas – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum running temperature degree 850 ° C, please suggest

One year Spare Elements Package for complete maintainability.
Mobile Incinerator

Point 6.
Mobile Incinerator variation F

Melt Rate 100kg/h minimum

Weight (kg), please indicate:

Second Chamber

Gas Retention Time – – – – 2 Secs

– Fuel – Diesel/LPG/LNG, please suggest

Power Supply for – Control Box – 220V-240V 50Hz solitary phase

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Bundle for full maintainability

10m Pipeline Pipe, suggest size

1000 Litre Gas Container + Pipe System, show amount

Additional smokeshaft expansion, show elevation

Service warranty, indicate no of years.
Warmth Waste Mobile Incinerator.
Product 7.
HTW Mobile Heater version G.
Burn Cost 100kg/h minimum.
Weight (kg), please suggest:.
Second Chamber.
Gas Retention Time – – – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – – – – 220V-240V 50Hz solitary stage

Minimum running temperature level 1200 ° C, please suggest.
Key burning.
Diesel/LPG/LNG burning primary burning chamber/primary combustion area.
2nd burning.
Residence time in the second chamber not much less than 2 seconds.
Both primary and the additional temperature levels protected up until all the waste has been totally ignited.
Smokeshaft.
Smokeshaft with a marginal altitude of 4 meters over ground level.
Minimum leave rate of the emissions not less than 10 metres/second.
Temperature level Cautions.
Audible and/or noticeable alarm to encourage the driver when the additional temperature goes down to listed below the called for temperature level.
General.
Control box that can be separated as well as mounted on separate stand at least 1.5 meters from burner at about 1.6 meter

altitude.
Assurance, show no of years

Weight (kg) please show:.
Service warranty, indicate no of years

Warmth Waste Burner

Ability at the very least (4000) kg/day (( Day= 16 Functioning Hrs))

Ability at the very least (4000) kg/day (( Day= 24 Working Hrs))

With the complying with qualities:

* Automatic feeder as original component of the device.

* Automatic ash/ leftovers elimination as preliminary element of the system.

* Water Injection System to control the temperature level > >

* Flue gas filtering system following by EU.

* Consistent discharge monitoring and also recording system.

elevation.
Guarantee, show no of years


Контейнерная мобильная горелка в сборе, контейнерного типа

Версия

CA100

Фото

Отходы терапии

Терапия сжиганием медицинских отходов

Возможность кормления

Обычные 100-200 кг на корм

Скорость горения

Обычно 100-120 кг в час

Время горения на корм

Стандарт 1-2 часа

Настройка управления

ПЛК (Инсинератор с программируемым логическим контроллером)

Напряжение

220В

Мощность

1.0 кВт

Топливо

Дизельное топливо

Горелка

Обогреватель Италии

Режим подачи

Справочник

Монитор температуры

Цифровой дисплей

Потребление топлива (масло)

Обычно 20,4 кг / час

Внутренние измерения

100x80x70 см (основная камера сгорания)

Внешние размеры

230 x 130 x 155 см (основной корпус)

Камера сжигания отходов

560литров

Запись в блоге Burning Chamber

280 литров

Емкость масляного бака

200 литров

Открытие двери

70 х 50 см

Камин

5,0 млн

Вес брутто

4500кг

Камерный продукт

Огнеупорный кирпич, огнеупорный бетон

Максимум. Теплая ценность

166000 Ккал / час.

Технические характеристики процедуры

Температура твердой камеры

8000C -10000 C

Температура в концентрационном лагере

10000 ° C -12000 ° C

Камера Anti-Rate

17500C

Время проживания

2.0 сек.

Горящая эффективность

> 98%

Отходы с более низкой теплотворной способностью

3000 ккал

HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-20

Incinerators

burn between 5000-10000 kg per hour.Mostly waste from crude oil tanks. construction, installation and 6 months maintenance cost including specifications.CMSD for Double Chamber Rotary Klin Type Incinerator (1st Chamber temperatur not less than 850 degree centrigrade & 2nd Chamber Temperature  not less than 1200 c with exhaust pipe 100 meter long with emission gas filtering mechanism ),  Hydroclave (Medical) with anciliary equipments operating parameters : Temperature 250-275 degree feren , Pressure 15-35PSI , Sterilization time 30 minus , Batch capacity -463 kg . two Incinerators for a hospital in VN. The anticipated capacity is approximately 1,000 kg per day.

fabricante de incineradores de animales

Lista de repuestos quemador de encendido

Descripción del artículo No de requerido

Motor 2

Caja de control 2

Acoplamientos de bomba 4

Fotocélulas 2

Establece ht. lleva 2

Juegos de electrodos 4

Válvula de aceite 1

Boquilla 2

Cumplimiento de parámetros

Tipo de Residuos Para el tratamiento de residuos médicos, categorías A, B, C, D, E

Tipo de incinerador pirolítico

Tasa nominal de combustión 50 t0 60 kg / ha 3500Kcal / Kg

Carga manual, carga por lotes

De Ashing Eliminación de cenizas automática o manual por lotes

El incinerador debe evitar la liberación de humo negro y polvo fino durante la carga.

Capacidad de la cámara primaria 2-3 m³

El aislamiento de la cámara de combustión debe estar compuesto por ladrillos refractarios, que tengan un mayor contenido de

aluminio y aislantes,

La placa de combustión en carborundo evitando la fijación de vidrios y escorias

Horas de funcionamiento / Día> 10 hrs

Temperaturas máximas de funcionamiento 1400 ° C

Temperaturas de funcionamiento normales (primarias)> 850 ° C

Temperatura de funcionamiento (secundaria)> 1100 ° C

Debe tener regulador de temperatura digital (regulador de temperatura en reloj digital)

Contenido de carbono de las cenizas <2%

La instalación debe estar completamente libre de humo visible y olores desagradables.

Tiempo de residencia en la segunda cámara 2 segundos mínimo

El diámetro interno de la chimenea: Ø 400

Altura de la pila> 8 m

Funcionamiento del quemador Encendido / Apagado automático

Combustible Diesel

Consumo de combustible a una capacidad raed> 7 kg de residuos / l

Consumo de electricidad <2kW a capacidad nominal

Voltaje de funcionamiento 220 – 240 V CA 50 Hz

Suministro de repuestos por 1 año cotizado como opción

Suministro de consumibles por 1 año de funcionamiento a mencionar como opción

Piezas de garantía y asistencia técnica: mínimo 1 año después de la puesta en servicio

Soporte de servicio <72 horas

Estándar de emisión Cumplimiento BS3316 o estándar equivalente

El sistema de filtrado de procesos Scruber se mencionará como opción.

Cumplimiento de fabricación CE BS EN 746-2-1997

Especificación de diseño Tipo A, B, C, D y E de desechos médicos

Instalación y puesta en servicio Incluido en condición de suministro

Capacitación en mantenimiento preventivo y curativo y uso del incinerador Capacitación del operador incluida en oferta

Capacidad para tratar plástico No menos del 40% en peso

Incenerator System

 

Incenerator
Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG and including all accessories with chimney in accordance with the technical specifications and public health regulations Item 2
Incinerators room for 3 incinerators as item 3-1-1, and waste store for keeping wastes for 7 days, including all constructions by reinforced concrete with Incenerator and store equipment, all wiring, lighting, water supply and drainage Item 1
Provide Incinerators room & waste store with fire fighting system, including sprinklers, approval of water source at site, fire alarm system contains sensors for heat & smoke, to be linked with the hospital fire alarm systems Item 1
Supply, installation & testing of ventilation system of Incenerator room & store by ROOF TOP EXHAUST FANS with HEPA FILTER, rate of change of air 5 times per hour, with ducts and air grills Item 1
Supply, installation & testing DUCTED SPLIT UNITS at waste store with sufficient capacity to maintain the internal temperature at 14 degrees Celsius in summers and winters Item 1

Needs for Twin Chamber Heater


BURNER DESCRIPTION
The Version is for as much as 300kgs capability per batch bunches in addition to will absolutely lose at around 55kgs per hour.
The system has leading packing style and has a strong refractory concrete lining for optimal heat retention. Gadget have huge leading cover for extremely easy loading, along with especially made front ash door, for ash elimination.
This system performs at over 1100 ° C in the vital chamber to guarantee total combustion. This design likewise benefits
from a strong second chamber as well as burner that makes particular a complete re-burn of any smoke along with exhausts along with a 0.5 second gas retention time.
Thaw rate 150kg/h minimum
Second Chamber Yes.
Gas Retention Time 2 secs.
Gas Diesel/LPG/LNG.
Power Supply for Control Box 220V-240V 50Hz singular phase.
Minimum Operating Temperature Level 920 ˚C

PRIMARY CHAMBER.
Resilient steel case.
Outstanding quality refractory lining as well as insulation.
Substantial full dimension leading lots door and also fluid retention sill.
1 x diesel oil terminated ignition heating systems operated on/off.
EXTRA CHAMBER.
Sturdy steel housing.
High quality refractory lining along with insulation.
1 x diesel oil fired ignition heating units ran on/off.
Requirements for Dual Chamber Incinerator:.
Key Burning.
The primary burning chamber will be approved as the crucial burning area.
The minimum burning temperature of the vital chamber shall not be much less than 800 degrees c.
Additional Burning.
The house time in the second chamber will certainly not be a lot less than 2 secs.
The gas temperature degree as gauged versus the within wall surface in the additional chamber, not in the fire zone will certainly not be less than as suggested in Lot 1-7.
Both the additionally additional as well as primary temperature levels will be maintained till all the waste has actually been completely ignited.
Chimney.
The chimney shall have a very little height of 4 metres over ground level.
The minimal departure rate of the discharges will not be less than 10metres/second.
Temperature Cautions.
When the second temperature level drops to listed below the required temperature level, a distinct and/or recognizable alarm to alert the operator.
General.
Control box can be divided and also installed on different stand of atleast 1.5 metres from the burner at about 1.6 metre altitude.
CE certified or equal for burners of this measurement and additionally design.
Drawings along with images for the provided whole lots.
1 year extra parts, gas containers as well as 10metre pipe ahead typical with every heater.
Specs for Mobile Heater Units.
Trailer mounted mobile burner tools excellent for the following applications.
Clinical waste.
Residential waste.
Industrial waste.
Pet cadavers.
SMOKESHAFT.
Resilient stainless-steel situation.
1.5 m dimension.
0.6 m refractory lined stack.
CONTROL PANEL.
Control of 1 heating unit.
Timer control 0- 12 hrs.
Vital fan timer control.
Temperature level Monitoring.
Thermostatic Control.
Automatic Control.
Cycle time developed.
ANCILLARIES.
Running along with maintenance handbooks.
Saves listing.
CONTAINERISATION.
incinerator absolutely mounted within 10 ft ISO accredited container.
3,5 kwA electrical power generator, 1000 litres fuel storage tank.
Burner placed on the silenblock padding.


Пиролитический двухкамерный инсинератор, малый размер : Цена сжигания : 30-45 кг / час ; Оптимальная грузоподъемность : 400 кг

Предметы / Модель

TS50 (ПЛК)

Картина

Принцип

Сжигание сильных отходов

Цена записи

30-45 кг / час

Режим управления

ПЛК (программируемый контроллер логики записи)

Горящая камера

560 л

Внутренние измерения

100x80x70 см

Вторичная камера

280L

Камера дымового фильтра

да

Настройка подачи

Руководство по эксплуатации

Напряжение

220В

Потребление масла (кг / час)

Типичный 13,3

Расход газа (м3 / час)

***

Дисплей температуры

Цифровое шоу

Температурный уровень защиты

да

Резервуар для хранения масла

800 л

Дверца подачи

70×55см

Камин

5 метров

Вид дымохода

Нержавеющая сталь

1-й. Уровень температуры камеры

800 ℃ – -1000 ℃

второй. Уровень температуры камеры

1000 ℃ -1200 ℃

Время проживания

2.0 сек.

Вес брутто

4500кг

Внешние размеры

230x130x155 см

HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-21

burning hazardous waste and chimicals incinerators

3 types of incinerators, which are 10Kgs, 20Kgs and 30Kgs for our Tawfiq Hospital use in Malindi, Kenya. we are an

environmental consulting firm as I’ve mentioned previously, we have already contracted with a French company specialized in

the sale of solid waste incinerators (ATI) and we bought a crematorium for the disposal of solid waste, including $ 180

thousand dollars, and now we want to get into the business of selling waste incinerators animal, and since it does not have an

agent in Saudi Arabia.  The three models you have indicated are based on 24 hour operation. Could you please make suitable

recommendations for 8-10 hour shift each day (including cooling time)? I assume we will need bigger capacity incinerators for

each of the three requirements.I am interested to know more detailed specifications and prices for your SYC-20 incinerator. I

am in the market for a small and easy-to-operate incinerator, however have little to no experience with such items.

installation and construction of SOLID WASTE
MANAGEMENT COMPLEX , for that purpose we need Sixteen (16) ton/day (7,538 kg/day) Capacity Incinerator System.1.5 ton garbage

per day,

required number of units -10 to 25 numbers

Installing different type of waste Management systems preferably Incineration and others for the state Jammu & Kashmir India

manufacturer and exporter of various Incinerator and other products.

Please be noted that we are a leading Bangladeshi business house dealing in various Medical, Surgical, Dental, Hospital

products, Plant and Machinery and so on

Most important is transformer, 220v motor, Temperature thermocouple, Blower of Primary Burner.

base on this portable incinerator,
1. the type of waste it can be use for (treatment).Hospital waste incinerators with reduced or carbon dioxide  CIF khartom –

Sudan

medical waste incinerators models for hospitals of 100-300 bed and 100-1000bed,kindly send price quote of all the YD models

and mode of transaction /delivery to nigeria

incinerator is for use in the hospital for burning hazardous waste and chimicals, minimum Capacity 300 per hour.

The hospital incinerator for use in the clinical waste as required by international environmental management. Minimum 300 Kg

capacity/hr, Fuel fired, refractory lined, chimney and sampling prot. Minimum temperature of 1100 degree Celsius kindly quote

me best price for resale.The best price for resale for the between $7000 to $12000 Usd I already have quotations just need the

best price please. price should be CIF Johannesburg or Durban