Archive: December 23, 2024

Incinerator Medical Waste Maximum Capacity



Basic Info.

 

Model NO.:medical waste incinerator manufacturers
Export Markets:Global

Product Description

 

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply clover incinerater, clover medical China medical west incinerator, cloverinvinerator, clovermed, incinerator for a hotel, incinerator for animal waste, different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Medical Waste Incinerators

Incinerator but the size of chamber > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr.
Fueled by Heavy OIL Burner.waste disposal incinerator, capable of handling both wet and dry garbage.. Which include house hold wastes and dry leaves.
The chamber of the incinerator should be able to hold about 200 – 250 kilogram of waste at a given time. edical Waste Incinerators.
The mobile unit is our priority then the fixed units. Medical Waste Incinerators. The mobile unit is our priority then the fixed units.
a;  Batch Capacity for each model, how much load can we put in one time. I need tio under stand in term of batch load one time I can ut in Kgs.
b:  Burning capacity per hour, to know how much time it will take to burn one batch and what is cooling timem for each one.
c: How many batch can we put in each day basis per 24 hours.
d: Most of systems will be run on Gas, so I need to know the required pressure of gas in psi to run the system without any problem.
e; I do wish to know an average life of system and after how many years we need the repair of linning etc.

2. What is your minimum capacity and maximum capacity incinerator.

3. You do provide secodn hand incinerator in good working condition.
4. We need only double chamber double burner incinerator.
5. Please send us DEFRA and DADR approval reports by attachment, copy of ISO and summary of gas emmission report from incinerators.

Incineradores de desechos peligrosos

Información básica.

Modelo NO .: horno para incineración de desechos animales
Mercados de exportación: Global

Descripción del producto

Características secretas :.
* Todos los modelos con doble cámara de combustión.
* Chimenea / chimenea de acero inoxidable, larga vida útil. * según pedido.
* Alta temperatura, larga vida útil del quemador.
* Configuración mínima o gratuita en el sitio.
* Alto índice de derretimiento, desde 10kgs hasta 500kgs por hora, fabricantes de crematorios, crematorio owen china, crematorio.
* Plano de control PLC. * según pedido.
* Nuevo diseño para el negocio familiar de cremación de animales domésticos.
* Garantía de un año en el quemador y también piezas en suministro.

Rango de aplicación:.
1. Instalaciones médicas y clínicas: Residuos ástricos, Residuos infecciosos, Apósitos, Residuos biológicos, Medicamentos …
2. Matadero && Hospital y granja de animales: Mascota muerta, Residuos biológicos …
3. Barrio y puerto marítimo y estación: Residuos urbanos fuertes, etc.
4. Laboratorios, ubicaciones remotas, fabricantes, crematorio de animales a medida, incinerador de torbellino, quemadores ciclónicos, equipos de eliminación de animales muertos, hasta 6 toneladas por día. Flujo de trabajo de alivio de calamidades, cremación de mascotas

Artículos / Modelo TS10 (PLC) TS20 (PLC) TS30 (PLC) TS50 (PLC) TS100 (PLC)
Velocidad de combustión 10 kg / hora 20 kg / hora 30 kg / hora 50 kg / hora 100 kg / hora
Capacidad de alimentación 20 kg 40 kg 60kg 100 kg 200 kilogramos
Modo de control SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA
Cámara de combustión 100L 210L 330L 560L 1200L
Dimensiones internas Los 50x50x40cm Los 65x65x50cm Los 75x75x60cm El 100x80x70cm El 120x100x100cm
Cámara secundaria 50L 110L 180L 280L 600L
Cámara de filtro de humo
Modo de alimentación Manual Manual Manual Manual Manual
Voltaje 220 V 220 V 220 V 220 V 220 V
Energía 0,5 Kw 0,5 Kw 0,5 Kw 0,7 kilovatios 0,7 kilovatios
Consumo de aceite (kg / hora) 5,4-12,6 7,8–16,3 10.2-20 12.1-24 14-28
Consumo de gas (m3 / hora) 6.2-11.4 8-15,7 9,8-20 9,9-26,1 10–32,2
Monitor de temperatura
Protección de temperatura
Tanque de aceite 100L 100L 100L 100L 200L
Puerta de alimentación Los 30x30cm Los 45x40cm Los 55x50cm Los 70x55cm Los 80x60cm
Chimenea 3 metros 3 metros 5 metros 5 metros 10 metros
Tipo de chimenea Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable
Tiempo de residencia 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg.
Peso bruto 1500 kg 2200 kg 3000 kg 4500kg 6000 kg
Dimensiones externas El 140x90x120cm El 160x110x130cm El 175x120x140cm Los 230x130x155cm Los 260x150x180cm
Contáctenos ahora Tel: + 86-25-8461 0201 <

Gasified incineration for melting medical wastes burner


Gasified incineration for shedding medical wastes.

Gas kind: Gas
Developed to melt disposables that can as well as should certainly be destroyed on-site. Theses wastes include also contaminated and infectious “red bag.” Surgical dressings, plastic assessment tools as well as different other wastes.
Quick, total, efficient garbage disposal.
Twin chamber combustion, Chambers insulated and also lined with high temperature refractory. Programmable digital temperature controls, temperature level indications and also cost recorder. Modulating control for gas along with air lowers gas consumption.
Minimum installation as well as also launch time.
Aluminized steel coat lined with refractory and firebrick. Screens recorders as well as likewise various other accessory equipment should be available.
Payment system:.
– – Upright price door on crucial chamber.
– – Pneumatically-driven or hydraulic ram charging system.
– – Car folded of the door after billing.
– – Main as well as additional chamber temperature offered and videotaped (optional).
Charging cost:.
– – As long as 100kgs per hour of waste or red bag waste rated at 2200 BTU’s per kg.
Gas:- Gas.
Capacity (Cubic Mtr): 1.65 M3 and even a lot more.
Ave Capability: 100kg per hr.
Added Chamber Capability (CubicMtr):3.88 or even more.
Size (mm): 1880 or much better.
Width (mm): 1280 or better.
Height Incl. Flue (mm): 7700 or much better.
Ash Door Opening (mm): 475×× × × 900 or much better.
Minutes. Running temperature level: 90 level centigrade.
Max, Operating Temperature: 1350 level centigrade.
Residency time in Secondly Chamber: 2 sec.
Temperature Tracking: Both for additional and main chambers.
Filling SystemManual/semi-automatic.
Waste devastation effectiveness: > > 90% by weight.
Filter: Different or ceramic other equivalent filters in order to decrease the induction of unsafe air pollutants, particulates, carbon monoxide gas, dioxin/furane right into the setting.
De ashing system: Manual/semi-automatic.
– Civil features. – Waste collection Trolleys.
Re-burning machine: Power max 0,2 kW Voltage: 220V/ 380V.
Weight: max 5000 kg

Burner size: max 2000x1200x3200 mm
Burning room volume:
–– Gasification space max 0.7 m3,
–– Additional burning area max 0.5 m3 ,

Dimension of the filling up entry: max 650×× 850 mm Air blower: max 0,5 kW Combustion-support burning devices: – Power max 0,2 kW INCINERATOR (WASTE BURNER).
Created to burn disposables that can as well as ought to be ruined on-site. Theses wastes consist of transmittable and also infected “red bag.” Surgical dressings, plastic examination tools as well as various other wastes.
Rapid, total, efficient garbage disposal.
Twin chamber combustion, Chambers insulated and also lined with high temperature refractory. Programmable digital temperature controls, temperature signs and also cost recorder. Modulating control for gas as well as air decreases gas consumption.
Minimum installment and also launch time.
Aluminized steel jacket lined with refractory and firebrick. Screens recorders and also other accessory equipment must be available.
Billing system:.
– Vertical cost door on key chamber.
– Pneumatic or hydraulic ram charging system.
– Auto closed down of the door after billing.
– Main as well as secondary chamber temperature presented and recorded (optional).
Charging price:.
– As much as 100kgs per hour of waste or red bag waste ranked at 2200 BTU’s per kg.
Fuel:- Natural Gas.
Capacity (Cubic Mtr): 1.65 M3 or even more.
Ave Ability: 100kg per hr.
Additional Chamber Capacity (CubicMtr):3.88 or more.
Size (mm): 1880 or far better.
Width (mm): 1280 or better.
Height Incl. Flue (mm): 7700 or far better.
Ash Door Opening (mm): 475×× 900 or much better.
Min. Running temperature level: 90 degree centigrade.
Max, Operating Temperature: 1350 level centigrade.
Residency time in Second Chamber: 2 sec.
Temperature Monitoring: Both for main and secondary chambers.
Filling SystemManual/semi-automatic.
Waste destruction efficiency:> > 90% by weight.
Filter: Ceramic or various other equal filters in order to lower the induction of unsafe air contaminants, particulates, carbon monoxide, dioxin/furane into the environment.
De ashing system: Manual/semi-automatic.
The System needs to be priced estimate total with:-.
– Pipes.
– Electric panels.
– Civil functions.
– Waste collection Trolleys.
Re-burning machine: Power max 0,2 kW Voltage: 220V/ 380V.
Weight: max 5000 kg


Горелки двойного нагрева, а также двухкамерные горелки Горючесть до 30 кг в час с мокрым скруббером

Горелки с двойным нагревом и двухкамерный мусоросжигатель Производительность до 30 кг в час
Список основных продуктов
Первичная камера сгорания (основной корпус из нержавеющей стали)
Вторичная камера сгорания (основной корпус из нержавеющей стали)
Камера смешанного сгорания
Мокрый скруббер (моечная башня) (основной корпус из нержавеющей стали)
Контроллер инсинератора
Дымоход: нержавеющая сталь 5.0 метров
Газовая горелка Италия: 02 комплекта
Масляный бак (для жидкого топлива): 100 литров

Модель

YD-30C

Возможность кормления

Обычные 50 кг на кормление

Горящая цена

Обычно 30 кг в час

Время горения на корм

2 часа

Напряжение

380В

Мощность

6 кВт

Топливо

Натуральный газ

Нагреватель

Обогреватель Италии

Настройка подачи

Справочник

Использование газа (нефть)

10,2-20,0 кг / час

Использование газа (газ)

12,2-24,0 м3 / час

Внешние измерения

170 х 140 х 190 см (текст)

Внутренние измерения

55 x 55 x 85 см (основная камера)

Камера сгорания для отходов

250 литров

Статья Камера сгорания

140 литров

Емкость масляного бака

100 литров

Открытие двери

38 х 48 см

Камин

5,0 млн

Вес брутто

3300кг

Материал камеры

Огнеупорный бетон

Максимум. Ценность тепла

200000 Ккал / час.

Технические характеристики эксплуатации

Температура твердой камеры

8000C -10000 C

Уровень температуры в концентрационном лагере

10000 ° C -12000 ° C

Камера Anti-Rate

13500C

Время проживания

2.0 сек.

Эффективность горения

> 98%

Отходы с более низкой теплотворной способностью

3000 ккал

Циклонный воздухоочиститель с водяным душем, менее окрашенный лист из стали марки 304 для камеры водоочистки
HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-02-26

incinerator plant specification

1)  Electricity Supply:
(a) Mains Supply:
(i)  Single Phase supply; 220 – 240V, 50Hz
(ii) Three Phase supply; 380 – 415V, 50Hz
(iii) The power supply outlet (sockets) for single phase supply system in the hospital is three pins and conforms to BS1363.

(b) Fluctuation:
(i)  Mains fluctuation is a common problem, the performance should be affected by this problem a tolerance of ±15% or more in both the nominal voltage should be allowed.
(ii) Mains Cut-off (black out) is a common problem. Where necessary, Uninterrupted Power Supply (UPS) Unit should be included to prevent damage of equipment as a result of sudden disruption in power supply.
(iii)        There are spikes not necessarily from the mains supply but results when certain plants or equipment started.
(iv)        Suppliers should therefore verify to ensure that their power supply units will not be affected by the above conditions.

2)  Water Supply
a)  Quality: the mains supply is hard water. The supplier should check/modify their equipment with filters or descalers where necessary.
b)  Pressure: this is variable and associated with frequent cut off. Where necessary, the supplier should include boosters or pumps to overcome this problem.
c)  Where necessary, suppliers should include water distillers

2-83    Section VI. Requirements

3)  Temperature:  ambient temperature ranges between 21 – 450  C or more in poorly ventilated rooms. The hottest month of the year is March. Environmental temperature can be such that inferior rubber and plastic materials can easily melt or deformed. Bidders must ensure all materials will be able to withstand such temperatures

4)  Humidity: humidity is usually high about 65 – 90%. Electronic units must be protected to prevent the effect of condensation.

5)  Dust: this is a major problem especially during the dry season. Dust get into equipment and clogs up filters. Additional protection must be provided where necessary and where applicable spare filters supplied to last not less than five years continuous use.

6)  Vermin: these are also available and occasionally enter into equipment to chew cables and urinate on boards to cause short circuit. This can be prevented by providing vermin guard where necessary to prevent entry of such destructive animals.
7)  The proposed equipment must conform to the current relevant international standard such as ISO; CE; IEC, ANSI and/or BS

8)  Language:
a)  All labels and markings on the equipment must be in English language. b)  All software programmes in the proposed equipment must be in English
language
c)  All manuals must be in English language.

9)  Each of the equipment supplied must be provided with user and technical manuals. Instructions on their usage, storage and service must be clearly indicated in the manuals and where necessary, on the equipment.

10)Where applicable the following shall apply:
a)  Electrical Safety
i)    The unit should be provided with a line (power) cord of acceptable durability, quality, length, and ampacity and should be secured with adequate strain reliefs.
ii)  The unit should include, or the bidder or supplier should offer, power plugs that are sufficient for the maximum voltage and current of the unit.
iii) The chassis should be grounded and grounding resistance should not exceed 0.15 ohm.
iv) If the unit is double insulated, it should be so labeled.
v)  Electrical leakage current from the chassis of the unit should not exceed
500µA per IEC 601-1 b)  Effects of Fluids

Section VI. Requirements    2-84

i)    Patient and operator safety and system performance should not be adversely affected by fluid spills.
ii)  If the unit is affected, it should fail safely.

c)  Overcurrent Protection
i)    Loss of power to other equipment on the same branch circuit due to internal equipment faults should be prevented by using fuses or circuit breakers that are clearly labeled and easy to replace or reset.
ii)  If fuses are used, a spare fuse should be provided in a labeled holder located next to the main fuse holder. Permanent markings near each fuse holder should indicate fuse ratings.

d)  Line Voltage Variation
i)    The unit should operate satisfactorily at line voltages from -12.5% to +8%
of the nominal line voltage of 220Volts.
ii)  The unit should not be damaged by voltages from -21% to +12.5% of the nominal line voltage of 220Volts.

e)  Electromagnetic Interference (EMI)
i)    The unit’s performance should not be affected by EMI radiated or conducted through the power lines from another device.
ii)  If the unit is affected, it should fail safely.

f)    Alarms
i)    The unit should have visual or audible alarms to warn operators of any system fault that may cause unsafe or erroneous results.
ii)  Audible and/or visual indicators should activate when the display reading reaches and remains at the alarm limit.
iii) All alarms should be fully explained in the operator’s manual.

g)  Audible Alarms
i)    Audible alarms should be distinct and easily identified.
ii)  Audible alarms should be enabled when the unit is turned on (i.e., the default volume should not be set to OFF) and should be clearly audible at any volume setting.
iii) If the alarm volume is adjustable, it should not be possible to turn the volume down so low that it is not likely to be heard.
iv) Although an audible-alarm silence is acceptable, the alarm must recur automatically if the condition is not corrected.
v)  If an alarm is silenced, a visual display should clearly indicate which alarm is disabled.

h)  Visual Alarms
i)    Visual alarms should be easy to identify.

2-85    Section VI. Requirements

ii)  The visual alarm must be specific to the problem and remain on until the alarm condition is corrected; it should not be possible to turn off the visual alarm.

i)    Construction Quality
i)    The unit should have no sharp edges.
ii)  All external components should be securely mounted.
iii) The unit should be secure and provide adequate protection against moving and electrically energized parts.
iv) The unit should be well constructed with durable materials to withstand typical abuse and cleaning.
v)  Switches, knobs, and other controls should be designed for conditions of heavy use.
vi) Wiring and tubing should be neatly arranged and bundled, if appropriate. vii) Mechanical, electric, and pneumatic terminators, connectors, sockets, and
solder joints should be designed to prevent fluid penetration, incorrect connections, and mismating of fitting and couplings.
viii)Connections should be secure to resist accidental disconnection and should maintain sterility, when appropriate.

j)    Controls
i)    The controls (i.e., switches, knobs, etc.) should be visible and clearly identified, and their functions should be self-evident.
ii)  Device design should prevent misinterpretation of displays and control settings.
iii) Switches and controls should be protected against accidental setting changes (e.g., due to someone brushing against the panel).
iv) Controls should be sealed against penetration of liquids.

k)  Labeling
i)    Labels and markings should be clear and legible.
ii)  Labels and markings should be durable enough to withstand routine cleaning and normal wear.
iii) Appropriate warning legends should be provided on the unit.

l)    Ease of Use and maintenance
i)    The unit should be simple to learn to use, operate, and maintain.
ii)  The unit should have abbreviated operating instructions included on or with the unit (e.g., on a laminated card attached to the unit).
iii) The unit should be easy to clean, disinfect, and/or sterilize, as appropriate. iv) The unit should be designed for easy access to serviceable parts.

m) Special maintenance tools, spare-parts and consummables
i)    Where necessary or required, the supplier must include any special tools required for the maintenance of the proposed equipment
ii)  Each equipment must be supplied with the recommended spare-parts

Section VI. Requirements    2-86

required for preventive maintenance for five years and where necessary include stock of recommended spare-parts for corrective maintenance.
n)  Training
i)    The supplier is required to provide adequate training on each equipment on the proper use and operation of the equipment.
ii)  Similarly, suppliers are required to provide adequate manufacturer’s training on the installation and maintenance(both preventive and corrective)
o)  Packaging and Storage Conditions of Equipment
i)    The equipment and components should withstand temperature and humidity extremes likely to be encountered during storage and transport.
ii)  The manufacturer should recommend procedures for storage of the equipment.

Containerized diesel fueled burners


Heater Kind: Containerized, gasoline
Burning Price:100–– – – 120kg/hour. Minimum Operating Temperature:850 o C( key combustion).
Optimum Operating Temperature:1450 oC( Afterburner chamber).
Extra Burning Ability: Compulsory.
Density Insulation:20 mm High.
Refractory Dispersing: Minimum 65mm.
Strong refracting lining to hold up against:1500 oC.
Common stress out time: optimum:3 personnels.
Fuel kind: Diesel.
Gas Intake in L/hr:7.5 to 9.
Residence time in secondary chamber:2 sec.
Residue ash pot 100kg: Max 3.8 kg.
Heater kind: Pet waste burner.
Lots Capacity minimum: 1500 kg.
Heating unit gas kind: Diesel.
Heater fuel price max.: 20-25 Litre diesel/ per hr.
Heaters minimum: 3.
Burning rate minimum: 200-300kg/ per hr.
Heating system bar place minimum: 2 м3.
Gas container capacity minimum: 300L.
Key chamber melting temperature level min. 1100 0C.
Afterburner chamber burning temperature minutes. 1300 0C.
Power supply 220V.
Burner products and also electrical tools should be weather condition proof as well as also moisture immune within the collection of 30-90 %.
Burner requires to be certified to the ecological monitoring policies in accordance to national legislation.
Maximum dimensions– – Dimension – 5m, size – 3.5 m, altitude – 5m


medical was incinerators Department of Health

hospital waste management team at a tertiary care hospital ,1250 beeded hsopital .

our daily waste generated from all sources is 0.55kg/bed/day =685kg/day

we need an incinerator of 150kg/hour loading capacity.

plz reply with , buying,installation, running and maintenance cost.incinerators, specifically, medical was incinerators
Department of Health has floated a tender for Incinerator X 1 Unit and the closing date is on 16th June 2011. The specification of the Incinerator is as below:

Specification of Incinerator

1.    Should have preparation, Incineration, Scrubber steps to burn waste completely and waste gas should be non-polluted

2.    Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial vane, suitable drum (S/S, thick) for the incinerator must be provided.

3.    Approx. 20 to 25 Kg per batch and the time required for 1 batch not more than 1 hour on average.

4.    Ash should be only 5% of the waste material

5.    Weight of Incinerator – 50-60 Kg

6.    220V AC

7.    Surgical , medical & laboratory waste

8.    B X L X H = 4 feet X 8 feet X 6 feet

9.    1 year warranty

10. ISO Certified

11. Mobile Incinerator

12.  Electric

запасные части горелки для отходов икловера

Мы являемся производителем, подрядчиком и экспортером мусоросжигательных установок в Китае. Производитель устанавливает разумную цену для потребителя инсинератора, поставляет медицинский инсинератор, больничный инсинератор, инсинератор для животных, инсинератор для свиней, оборудование для кремации домашних животных, небольшой инсинератор, инсинератор для домашних животных, инсинератор для животных, переносной инсинератор, инсинератор для мелких животных, установку для пиролиза инфекционных отходов, лабораторный инсинератор. HICLOVER помогает клиенту сократить бюджет покупки, индивидуальный функционал, качественные продукты и дружелюбное обслуживание.
Огнеупорный цемент, трансформатор розжига – вторичная горелка, трансформатор розжига – первичная горелка, аварийная кнопка, пара термоса температуры с контргайкой – 1600oC, пара термоса температуры с контргайкой – 1300oC, контроллер отображения температуры – вторичная камера, контроллер отображения температуры – первичная камера (параметр – Цифровой прибор регулировки), датчик освещения горелки (фотоэлемент) PBT / PC
Печатная плата (LM44.255C2BT) Вторичный каскад высокого уровня, Печатная плата (LOA24.171B2BT) Первичный
Противопожарная фланцевая прокладка, Противопожарная фланцевая прокладка
CA50-600, EB14HPM, 26-48-3371T JT04, K1600, k1300, XMT – 3000, XMT – 2000 QRB1, LM44.255C2BT, LOA24.171B2BT, SN834457 8023020001, SN834451, 3713798, AS47B, FO03
Электрод розжига с выводами (для горелки BTL20 / SPARK35), Соленоид (для горелки BTL20 / SPARK35), Топливный насос горелки (для горелки BTL20 / SPARK35), Топливный фильтр (для горелки BTL20 / SPARK35)
Горелка – Baltur, Горелка – Baltur, Соленоид, Топливный насос горелки
Кабель зажигания, выключатель зажигания – (блок управления), фотоэлемент
HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-06

incineradores de residuos médicos

Todas las etiquetas con texto estarán en inglés.

Calentadores anticondensación

El Panel estará provisto de un calentador anticondensación controlado por termostato de 240 V, 50 Hz.

Sistema de puesta a tierra

Todas las partes metálicas normales que no transportan corriente del panel y los componentes asociados deben estar unidas a un cobre común.

barra de tierra que recorre toda su longitud en el interior del cuadro.

La barra de tierra debe estar ubicada en la parte inferior del marco y provista de dos puntos de terminación para

Conexión a la red de puesta a tierra principal.

2.5 Suministro de aceite de encendido

INTALIACIÓN DEL INCINERADOR DE RESIDUOS MÉDICOS

Diseño, suministro, instalación, prueba y puesta en servicio de residuos médicos.

Incinerador según especificación adjunta. El precio será

incluye todos los accesorios incluida la obra civil y recambio

lista para completar el sistema.

capacidad de combustión del incinerador-250 kg / h NO 1

Hospital de referencia de la Universidad de Jimma

Incinerador

Incinerador de desechos médicos

Propósito

Para una completa destrucción de residuos de diversos servicios hospitalarios mediante tratamiento térmico de alta temperatura de acuerdo

con el estándar de la UE sobre requisitos de emisión

 Residuos de actividades de atención médica

 Desechos de infecciones, cultivos de laboratorio, desechos del material de aislamiento de la sala de operaciones en contacto con

pacientes, residuos potencialmente infectados por agentes patógenos.

 Desechos patológicos, fragmentos humanos, negrita, feto, todos los fluidos corporales, tejidos humanos.

 Esculpir, agujas, equipos de infusión, cuchillas, vidrio

 Residuos farmacéuticos.

Reactivos de laboratorio de desechos químicos, desinfectantes

 Medicamentos vencidos.

 Elemento radiactivo de baja radiación.

Incinerador de desechos médicos: – Requisito ecológico

-Sin olor

-Sin humos

-Tratamiento definitivo de residuos

Incinerador de desechos médicos: – Normas de fabricación

-Estándar de emisión UL, CE, ASME, ISA EURO

1.Incinerador de desechos médicos

Construcción: carcasas de placas CS, refuerzo FB, revestimientos refractarios de casta,

Aislamiento y chaqueta de aluminio de calibre 14.

Tipo de combustible: gasoil (diésel)

Capacidad de combustión: 250 kg / h y humedad hasta 80%

Duración-8-16 / Continuo

Consumo medio de combustible: muy poco tanto como sea posible

Tipo de control: operación basada en PLC

Temperatura de funcionamiento: cámara primaria 800c ± 50

– Cámara secundaria 1050c ± 50

Tamaño del incinerador: no más de 15 mx 7,20 m

Chimenea – Q630x25 metros de altura y 7 mm de espesor CS.

Eficiencia de combustión: 99%

Modo de manejo de residuos – Semiautomático mediante cargador de ariete.

Modo de manejo de cenizas – Semiautomático mediante parrilla y carro de cenizas.

Equipo de control de la contaminación – Zona de asentamiento seco

Puertas – 1 puerta de carga de residuos en la cámara principal

1 puerta de clínker en cámara primaria

1 puerta de acceso al carro de cenizas en la cámara principal

1-Limpiar la puerta en la cámara secundaria

Quemador -2- quemador de encendido en cámara primaria

Quemador de 2 postes en cámara secundaria.

Tipo- paquete monobloque-completamente automático

Tipo de funcionamiento del quemador: control de modulación

Ventilador de tiro forzado – 1 ventilador de aire primario

1 ventilador de aire secundario

Tanque de almacenamiento de combustible – Capacidad-2500 litros por encima del suelo

– Material: acero dulce de 6 mm de espesor.

-2-bomba diesel, válvula de compuerta, válvula de seguridad, filtro

tubería, manómetro, válvula de retención, tablero de control

Indicador de nivel. Etc.

Espesor refractario / de aislamiento: no menos de 225 mm

Capacidad del cargador ram: 0,75 m3

Suministro eléctrico -380v / 3ph / 50 Hz

Tipo de acabado y pintura: recubrimiento en polvo

Sistema de alarma audio / visual: bloqueo del quemador, falla de sobrecarga

Accesorios eléctricos: temperatura de la cámara primaria y secundaria

Controlador / indicador, controles automáticos, eléctricos

Interruptores de control, pulsadores, relés contactores

Termopares, controladores de secuencia de quemadores,

Temporizadores, parada de emergencia y alarmas.