Archive: January 13, 2023

small scale incinerator

Incinerators Biological waste disposal system (incinerator)

Incinerator must meet the following specifications:

–       Combustion capacity (kW) = 581 +/-10%

–       Combustion capacity (kcal/h) = 500,000 +/-10%

–       Max. l/h (at approx.. 50% water content) = 100 +/-10%

Further specifications will be provided with the inquiry.

The incinerator shall be fully self contained.

The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance.

Capacity of destruction in weight shall be 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…

Design Specification : Types A, B, C, D, and E of medical waste

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator must avoid the release of black smoke and fine dust, during the loadings.

It shall be able to reduce the volume of wastes by 98%.

It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a complete layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its height: 8 m

The Volume of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm at least: 70×70.

Burner operation should be Automatic On/Off
Fuel?: diesel

Manufacturer to provide  necessary information for the best of  the installation

The control panel shall have all appropriate audible and visual alarms to ensure safe operation.

This incinerator with “PYROLYTIC” combustion must have:
1.A combustion chamber of waste:
oPerfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
oA burner of lighting which the use is limited to the ignition of waste.
oFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
oThe insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
o Composition of the refractory;

?Refractory concrete :
. Thickness    : ≥100 mm
. Nature: 42% of Al203
?Insulate in fibrous panels :
Thickness: ≥75 mm
Nature: Calcium silicate.
?Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
Plate of combustion in Carborundum, avoiding the fixing of glass and slags

A chamber of post combustion of gases
oA burner of combustion of gases,
oA device of injection of air allowing a total recombustion of gases,
oA device of air inlet of cooling of waste gases,
oA sheath of evacuation of the gases burnt.
oCarcass in strong sheet steel with support of connection.
oComposition of the refractory;
?Refractory concrete :
?Thickness    : ≥150 mm
?Nature: 65% of Al203
?Insulate in fibrous panel :
?Thickness: ≥85 mm
? Nature: Calcium
oBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
oA secondary injection of air to ensure perfect oxygen content.

A control box ensuring the complete cycle of combustion.

Fan:
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
Controls and regulations:
Control box watertight to dust, including:

A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post combustion.
Electric box

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional

About Hiclover Medical Enviromental


HICLOVER is growing brand for environmental protection field, and market share with the majority of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We a re trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc.. We have export experience more than 40 countries, including war zone such as Iraq, Afghanistan, Somalia, South Sudan.


Manufacturer make reasonable price for incinerator client, provide medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, mobile incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer decrease buy budget, custom made function, quality products and friendly service.


The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all around the world.
The incinerator burn waste in main combustion chamber and burn the smoke from main combustion chamber again to ensure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria disease.


We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.

Контейнерный мобильный мусоросжигательный завод

Контейнерные мобильные инсинераторы Основная особенность: – Двойная камера сгорания – Двойная горелка Италия – Скорость горения: 10-100 кг в час – Камера сгорания: 0,1 м3-1,2 м3 – Мобильная инсинератор, стандартные контейнеры для транспортировки, простая в перемещении / транспортная система – Бесплатная установка, Предварительно установленная печь для сжигания, идеально подходит для лагерей – Стерилизация ультрафиолетовой лампой внутри Дополнительные функции / Детали / Материал / Скорость горения: – Дымоход из нержавеющей стали – Камера сухого дымового фильтра – Высота дымохода на заказ – Повышение / снижение скорости горения

Incinération des déchets HICLOVER Modèle TS75

Incinération des déchets HICLOVER Modèle TS75

Articles / modèle

TS75 (API)

Photo

Principe

Incinération des déchets

Prix de gravure

75 kg / heure en moyenne

Capacité d’alimentation

Typique 150kg

Réglage de contrôle

PLC (Incinérateur de contrôleur de raisonnement programmable)

Chambre brûlante

770 L

Mesures intérieures

100x81x95cm

Deuxième chambre

385 L

Chambre de filtre à fumée

Oui

Mode d’alimentation

Manuel

Tension

220V

Pouvoir

0,7 Kw

Consommation d’huile (kg / heure)

Typique 16,9

Consommation de gaz (m3 / heure)

***

Moniteur de niveau de température

Affichage numérique

Sécurité du niveau de température

Oui

Réservoir de stockage d’huile

100 L

Porte d’alimentation

99 x 91 cm

Smokeshaft

3 mètres

Type d’arbre de fumée

Acier inoxydable

1er. Niveau de température de la chambre

800 ℃ –– -1000 ℃

2ème. Température de la chambre

1000 ℃ -1200 ℃

Temps de résidence

2,0 sec.

Poids brut

4500 kg

Mesures externes

2,30 mètres x 1,30 mètres x 2,55 mètres

Incinérateur de déchets cliniques de 15kg-20kg conduit par LPG pour brûler des matières hautement infectieuses
100 kg par heure * un incinérateur médical * est nécessaire dans la taille d’un * conteneur de 20 pieds. *
Taux de combustion de 100 kg / heure avec
avec capacité de combustion secondaire
Je suis intéressé par votre produit Longue durée de vie Pet Crematory (YD-15), je veux savoir plus de détails sur:
Veuillez me proposer une liste de prix précis.
Ce serait formidable si vous pouvez me faire parvenir plus de détails sur ce produit.
Crémateur humain pour machine de crémation de crématorium
Incinérateur automatique de déchets médicaux avec systèmes de chargement automatique.
La capacité de travail de 150 KG CHAQUE LOT
incinérateur à utiliser pour l’incinération des déchets médicaux / cliniques

Required Specifications for Mobile Incinerator

Operational Capabilities

  • PROCESS MINIMUM 1 TON PER DAY
  • OPERATED WITH LIMITED TRAINING
  • REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING
  • COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
  • ABILITY TO BURN WASTE LUBRICANTS (POL)
  • HANDLE ORGANIC SOLIDS (TO INCLUDE RMW)
  • DEPLOYABLE
  • MOBILE
  • 24 HRS OF CONTINUOUS USE
  • AUTOMATIC LOADING SYSTEM
  • AUTOMATED ASH REMOVAL SYSTEM
  • GAS SCRUBBING SYSTEM
  • 95% REDUCTION OF SOLID WASTE
  • OPERATE OFF DIESEL OR FUEL OIL
  • CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
  • ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD
  • NO PRE-TREATMENT OF WASTE REQUIRED
  • FIVE (5) YEAR COMPONENT WARRANTY

 

 

 

Technical Specifications

  • OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR
  • SET UP AND INSTALLATION INSTRUCTION MANUALS
  • BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS
  • INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION
  • OPERATED AND TRANSPORTED IN 20’ INCINERATORS (CONTAINERS)
  • FULL FRONT AND OPTIONAL REAR ACCESS
  • PRIMARY / SECONDARY TEMPERATURE CONTROLS

Medical Incinerator

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like medical waste heat value, medical waste incenerator, medical waste incinerater, medical waste incineration china, medical waste incinerator (yd-300), 
Medical waste incinerator manufacturers u. S. A, hospital, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Product List
Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Scientific waste burner 100kgs Style TS100


incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator

Items/Model

TS100

Shed Cost

Common 100 kg/hour

Feed Capacity

Standard 200 kg/feed

Control Mode

PLC

Combustion Chamber

1200L

Interior Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7 Kw

Oil Intake (kg/hour)

14– – 28

Gas Consumption (m3/hour)

10– – 32.2

Temperature Level Monitor

Yes

Temperature Level Degree Protection

Yes

Oil Container

200L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st.

Gross Weight

6000kg

Outside Measurements

260x150x180cm

2020-04-06

External Measurements

260x150x180cm



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-06


Farm Incinerator

Basic Info.

Model NO.:farm animal equipment cremation creamatotium incin
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *based on order  * High temperature, long lifetime of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock. 

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Incinerator is a incineration gear, direct fire thermal oxidiser china, thermal oxidizer china, thermal oxidizer, toxic gas waste disposal incinerator, toxic wast supplier in china, trailer mounted animal carcass incinerator, waste by gasoline fuel or oi gas. As different circumscription, incinerator could be named many words as under: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators 

Incinerator gas: Gas incinerator, petroleum incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

incinérateur de déchets médicaux

Conception brûlante australienne exclusive 5 25kg / heure
incinérateur à double chambre (GPL) ou équivalent accepté. incinérateur
le boîtier doit être en acier doux avec un revêtement réfractaire de 125 mm composé de
clé et deuxième chambre, section de tirage isolée ci-dessus
chambre secondaire, brûleurs groupés, contrôle numérique de la température
systèmes, râteau à cendres et poke, 2ème porte dans la chambre principale,
goulotte de chargement pratique, compteur semi-automatisé bien équilibré
porte d’emballage avec plateau d’emballage complet avec conduit de fumée en acier inoxydable
composants de rechange recommandés.

ความรู้ที่เกี่ยวข้องของตัวกรองม้วนอัตโนมัติ (ตัวกรองหน้าจอลูกกลิ้ง): การแนะนำผ้าฝ้ายกรองพิเศษสำหรับม้วนตัวกรอง

16 พฤษภาคม 2019 Industry News 204 views

ต่อไปนี้คือคำแนะนำสั้นๆ เกี่ยวกับจุดความรู้ต่างๆ เกี่ยวกับวัสดุกรองแบบม้วน เพื่อให้ลูกค้าใช้อ้างอิงเมื่อซื้อวัสดุสิ้นเปลืองเป็นครั้งที่สอง

1. ทำจากใยแก้วยาวในโครงสร้างไม่ทอและค่อยๆหนาแน่น เส้นใยมีความแข็งแรงและยืดหยุ่นได้ดี และไม่บีบอัดวัสดุกรองเนื่องจากความต้านทานลม ซึ่งส่งผลต่อความสามารถในการกักเก็บฝุ่น และจะไม่ทำให้เสียรูปหรือทำให้เส้นใยบินภายใต้การสั่นสะเทือนและม้วนตัว

2. ตาข่ายรองรับกริดที่แข็งแรงติดอยู่ที่ด้านหลังเพื่อป้องกันประสิทธิภาพการกรองของวัสดุกรองภายใต้การทำงานด้วยความเร็วลมสูงบนหน้าตัด

3. หน้าจอตัวกรองที่ปนเปื้อนถูกห่อหุ้มไว้ด้านในและพันไว้รอบๆ ตำแหน่งของกลไกวัสดุกรองด้านล่าง ซึ่งไม่เพียงเปลี่ยนได้ง่ายเท่านั้น แต่ยังสะอาดและถูกสุขอนามัยอีกด้วย

4. หน้าจอตัวกรองมีอายุการใช้งานยาวนาน และสามารถเปลี่ยนหน้าจอตัวกรองได้โดยอัตโนมัติเมื่อถึงความแตกต่างของแรงดัน ซึ่งจะช่วยลดต้นทุนแรงงานในการเปลี่ยน

5. มีแกนกระดาษด้านใน ซึ่งสะดวกและรวดเร็วในการเปลี่ยน และสามารถใช้ร่วมกับผลิตภัณฑ์ตัวกรองชัตเตอร์ลูกกลิ้งของผู้ผลิตรายอื่น

จะเห็นได้ว่าวัสดุกรองเป็นส่วนหลักของตัวกรองม้วนอัตโนมัติ เมื่อเราซื้อวัสดุกรองทดแทน อันดับแรก เราต้องพิจารณาเลือกประสิทธิภาพของตัวกรองที่เหมาะสม และประการที่สอง พิจารณาว่าบรรลุผลตามที่ต้องการหรือไม่ นอกจากนี้ เราต้องพิจารณาถึงประโยชน์เชิงเศรษฐกิจของการทดลองด้วย

URL เนื้อหาเพิ่มเติม: www.ecolead.cn โทร: 025-57138032