Archive: January 1, 2023

Crematorium Equipment

Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

CLOVER supply medical equipment, medical waste incinerators, pet animal cremator, other solid waste treatment equipment, clean room equipment, fan filter units, purchase incinerator, pyrolytic incinerator, ram feed hospital incinerators manufacturers, air filter, etc. We supply technology service, installation service and customer made. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator for hospital waste management

Incinerator for hospital waste management with the following features:

• In high temperatures (pyrolytic incinerator two chambers with temperatures ranging from 950 º C to 1320 º C;

• Ability to destruction of 400 to 600kg per hour;

• Capable of destroying microorganisms;

• Drain ash;

• Drain needle and glass crusher;

• Porch with tap water for hand washing and decontamination;

• Observe the issue of environmental quality standards, emissions fluent and regulation on the issue of waste;install large incinerator to one of the biggest veterinary hospital in KSA so if you will support us with one unit (large incinerator) and environmental with onsite training , the capacity for the unit is 2000 Kg for cattle , horses and farm animals also suitable to all animal waste types , we need it diesel fired . OES-Industrial MultiWaste Incinerator System (Solid/Liquid)

Scope of the Work:
Design, installation and commissioning of multi industrial waste incinerator.
Capacity: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with dual chamber system)
1st chamber-870 Deg.C – 900 Deg.C
2nd chamber-1000 deg.C – 1200 Deg.C

Sources Of The Wastes
The following types of wastes can be treated by using incinerator.
a). bio medical waste/pharmaceutical waste
b). solid chemical waste/textile industries waste
c). liquid chemical waste
d). dyes and intermediate waste
e). organic chemical waste
f). liquid ink waste/acidic residue
g). insecticides/herbicides/pesticides
h). fungicide waste
i). ethanolamine
j). amino ethanol
k). mono ethanolamine
l). ETA,MEA waste
m). wastes after treatment of chemicals in etp plant.
n). mixed liquor waste water
o). alcoholic waste.
p). agricultural liquid chemical waste.
q). sludge mix liquid
r). slurry/adhesive/grease/powder coating wastes.
s). semi solid liquid chemical waste
t). bulk dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass beads
w). used tires.
x). used cotton rags
y). contaminated plastics/resin wastes.
Scope of Work:
Incinerate all types of liquid/solid hazardous/chemical/non hazardous wastes avaliable in the industries with proper scrubbing system with standard emission rates.
The dual stage incinerator helps to burn the waste in two stages , first at a medium temperature of 870- 900 Deg C and the second stage at 1200 deg C
Producing ash and Gaseous fumes which are treated with cyclone type wet scrubber and caustic scrubber to produce air with pollutants in the permitted range and Non hazardous ash mainly inorganic salts.

Incinerator utilities
Incinerator should have following criteria:
Metallic seal structure with ceramic insulation to avoid heat  radiation and control radiant temperature
Advanced gas treatment system to avoid emission of toxic gases (scrubbing system).
Low consumption high efficiency compact automatic burning system.
Low running and maintenance costs
Fully automatic and simple to operate control panel
Afterburner Preheat
Dense refractory concrete lining rated at 1600 C
Solid Hearth to allow maximum Burnout
Large Top opening lid for easy loading
Wide door for ash removal
Optional Stainless Steel Casing
Heat recovery option

Incinérateurs mobiles conteneurisés

Conteneurisé Mobile Incinérateur (modèle CA)

HICLOVER fournit actuellement une gamme complète de systèmes d’incinération conteneurisés, nous positionnant à l’avant-garde des tendances de transport et commerciales les plus actuelles.

La conteneurisation est l’option la plus pratique et la plus viable par rapport à la construction d’installations sur site et également de cadres immobiliers, en éliminant le pouvoir des haubans et les coûts occasionnés.

Caractéristique principale:

– Chambre de combustion double

– Double Italie Brûleur

– Taux de combustion: 10-100kgs par heure

-Chambre de combustion: 0,1M3 -1,2M3

– Incinérateur mobile, conteneurs d’expédition standard, système facile à déplacer / transport

– Installation gratuite, incinérateur pré-installé, idéal pour les camps

– Stérilisation par lampe ultraviolette à l’intérieur

※ Fonction optionnelle / Pièces / Matériau / Taux de combustion:

– Cheminée en acier inoxydable

– Chambre de filtre à fumée sèche

– Hauteur de la cheminée sur mesure

– Taux de gravure de mise à niveau / rétrogradation

The Expense of a small incinerator


Medical Waste Incinerator Capacity: average 50-100 kgs per hour

Items/Model

TS50(PLC)

Picture

 

Principle

Medical Waste Incineration 

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 100kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Consumption (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

800℃–1000℃

2nd.

Gross Weight

4500kg

External Dimensions

230x130x155cm

Optional Part: Stainless Steel Wet scrubber


HICLOVER Incinerator/Parts Range


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Main Feature

Nanjing Clover Medical Technology Co.,Ltd.

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For additional animal incineration

Items/Model

TS100(PLC)


TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm



Sudan Kassala state and we are working on installing an incinerator for Girba hospital in Girba locality.
 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

2020-10-28

 

2020-10-28

500kg/day thaw ability heater


in acinerator with 300 kg/ hr by twin filter wet along with dry.Pet Cadaver Incinerator upto 80 kg, gas run resembles. pet waste heating unit with capacity pertaining to 40Kgs. We will utilize this thing to thaw the animal continues to be alike technique (not ill aninal). Can you please in advance me quote for heating unit that appropriates for solution Neighborhood with a people of 200,000 individuals including various other standard neighborhood waste to lose. Technical demands information sheet
List as well as likewise quantities of consumables called for month-to-month
Listing in addition to also cost of all the spares called for annually
Checklist in addition to prices of all the spares required in 5 years
List as well as additionally costs of all the spares required in one years

2 burners one with 500kg/day shed capacity an additional one with 1000kg/day thaw capacity

1 x Electrode

1 x Gas Filter

1 x Photocell

1 x Versatile pipeline

1 x Nozzle

1 x Control Box


Mobile Cremation Equipment

Model

CA-200

Picture

Burning Rate

Average 100 kgs/hour

Primary Combustion Chamber

2000 Liters

Secondary Combustion Chimney

Yes

Feed Mode

Manual

Voltage

220V

Power

3.0 Kw

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 53 kg/hour

Internal Dimensions

230 x 100 x 90cm (primary chamber)

External Dimensions

290 x 200 x 170cm (primary chamber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

90 x 90cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

9000 kgs(with container)

Operation Technical Specifications

Paimary Chamber Temperature

800–1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal


Mobile crematorium 
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22

Medical Waste Incinerator

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

 
 
********************************************************************************************************

HICLOVER Solution for Fighting COVID-19, with CE Certification Pass.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room
 


2020-10-28
 
 

Medical Environmental Waste Incinerators Auto Roll Air Filters
 
Medical Waste Incinerator |Mobile Incinerator|
Pet Animal Incinerator|Municipal Solid Waste  Incinerator

 
Online Contact Form/Subscribe to Newsletter: http://www.hiclover.com/contact/
 

Power
kW
Mcal/h 178 – 356
153 – 306
Fuel consumption rate L/h 15 – 30
Fuel Domestic fuel oil
Internal calorific value kWh/kg
Mcal 11.8
10.2 (10,200 kcal/Kg)
Density kg/dm3 0.82 C 0.85
Viscosity at 20°C mm2/s max 6
Operation Intermittent (1 min stop in 24 h)
One speed (on or off)
Sprinkler Number 1
Standard use Water, steam, diathermic oil boiler
Ambient temperature °C 0 C 40
Combustion Air Temperature °C max 60
Combustion temperature  °C 900 to 1100
Destructive capacity Kg/h (l/h) 120 (1600)
Power supply V
Hz 230 +/- 10%
50 single-phase
Electric motor rpm
W
V
A 2800
0.25
230
2.1
Motor capacitor µF/V 8/450
Ignition transformer V1 – V2
I1 – I2 230V – 8kV
1.8A – 30mA
flow 12 bans
Pump – pressure range
temperature
kg/h
bar
°C max 65
10 C 18
60
Degree of protection IP 40
Power consumption w max 0.43
Chimney height  m 6 to 8
Chimney diameter  mm Approximately 500
Tank volume  l 1000 to 1200
Number of ovens  2 to 3
Dimensions of the loading door cm About L80 x B60  
Combustion chamber: One-piece casing made of 3- and 10-mm thick sheet steel. Loading front with sealed door mounted on hinges, screw-type closing wheel, flexible seal, and refractory insulating lining.
Chamber materials made of refractory concrete with an alumina content of 42%AL2O3 and a wall thickness of 115 mm. Equipped with thermal insulation in fibrous panels made of calcium silicate with a thickness of 75 mm. It must also be equipped with a waste ignition burner.
Post-combustion chamber A post-combustion chamber for gases meeting the emission standards for certain gases (CO, HCl, SO2, NOx, etc.). 
Filter  Allowing combustion control and regulation of the treatment process;
A filter for reducing air pollution from incineration
Metal scraper  A metal scraper and an ash pan with handling handle.
Paint: light blue