Incinerator Version CA100, Overview
100Kg/Hour Burning rate with Secondary burning Capacity
This design is small medical waste incineration devices. Building and construction is dual/double
combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed
chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke
filter chamber with firebrick and refractory concrete chamber. Batch load on the bottom of
chamber. Incinerator panel control suit for local operation.
Version
CA100
Waste Therapy
Medical Waste Incineration Therapy
Feed Capacity
Typical 100-200 kgs per feed
Burning Price
Average 100-120 kgs per hr
Burning Time per Feed
Average 1-2 hr
Control Mode
PLC( Programmable Logic Controller Incinerator)
Voltage
220V
Power
1.0 Kw
Fuel
Diesel oil
Burner
Italy Heater
Feed Setting
Manual
Temperature Screen
Digital Display
Fuel intake (Oil)
Average 20.4 Kgs/Hour
Inner Dimensions
100x80x70cm (Key Combustion Chamber)
External Capacities
230 x 130 x 155cm (main body)
Waste burning chamber
560Liters
Blog Post Combustion Chamber
280Liters
Oil Container Ability
200 Liters
Door Opening
70 x 50cm
Smokeshaft
5.0 M
Gross Weight
4500kgs
Chamber Material
Firebrick, Refractory Concrete
Max. Heat Worth
166,000 Kcal/Hr.
Operation Technical Specifications
Solid Chamber temperature
8000C -10000 C
Concentration camp temperature level
10000C -12000 C
Chamber Anti-Rate
17500C
Residency time
2.0 Sec.
Burning performance
> 98%
Waste Lower Calorific Power
3000Kcal
Pre-assembled, containerized type,do not included chimney installation.Burning rate: 100 – 120kg / hour.
Minimum operating temperature 800-1000 degree.Maximum operating temperature:1000-1200 degree.
Secondary Burning capacity.Density insulation.Refractory casting.Heavy duty refracting lining to
withstand 1750 degree.Fuel type: fuel oil (diesel).
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator
Tel: +86-25-8461 0201
Nanjing Clover Medical Technology Co.,Ltd.