We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour.
the incinerators are now ready for shipping.
Contact with us for quick respond: +86-13813931455
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).
Items/Model
TS50( PLC)
Image
Concept
Waste Incineration Therapy
Burn Price
Standard 50-100 kg/hour
Feed Capacity
Ordinary 200-300 kg/feeding
Control Mode
PLC( Programmable Logic Controller Incinerator)
Optional Upgrade Containerized Mobile Kind Incinerator
Waste is thermally decayed in the main chamber at temperature levels of 800 ° C +. The resulting aeriform items are entirely oxidized in the second chamber at higher temperature levels with adequate resident time. Other specifications are as follows. A burning chamber of waste:
* Perfectly limited door for the manual loading of waste. The loading ought to be Manual, Set Load
* A burner of lights which the use is restricted to the ignition of waste.
* Frontage of loading with door seals risen on hinges, wheel of screw plug, flexible joint, as well as packing protecting out of refractory.
* The insulation of the burning chamber need to be made up of refractory bricks, having a high web content of aluminum and shields bricks in order to assure a minimum temperature on the outside sheet steel.
* Composition of the refractory
Burning Ability
Max. 200kgs/h
Supporting Gas
Diesel
Kind of Heater
Monoblock automatic heaters
Temperatures
Primary Chamber: 800 ° C ± 50 ° C. Additional Chamber: 1300 ° C ±
and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.
Main Product List per 01 collection
Primary Burning Chamber
Additional Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Instance
Smokeshaft:10.0 Meters
*( upgrade to Stainless-steel, complimentary expense)
Italy oil/gas heater: 02 units
Oil Tank (if oil fuel): 300Liters
Items/Model
TS200( PLC)
Picture
Principle
Strong Waste Incineration Therapy
Burn Rate
Average 250 kg/hour
Feed Capability
Standard 350kg/feeding
Control Setting
PLC( Programmable Logic Controller Burner)
Combustion Chamber
1800L
Internal Measurements
150x110x110cm
Second Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Handbook
Voltage
220V
Power
0.9 Kw
Oil Intake (kg/hour)
Ordinary 28
Gas Usage (m3/hour)
Typical 33.6
Temperature Level Screen
Digital Present
Temperature Level Security
Yes
Oil Tank
300L
Feed Door
80x60cm
Smokeshaft
10Meter
Smokeshaft Kind
Stainless-steel
1st. Chamber Temperature
800 ℃–– -1000 ℃
2nd. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
Exterior Dimensions
300x160x190cm
Heater procedure ought to be Automatic On/Off
Gas : diesel
The vendor must supply required information for the best of the installment
This incinerator with “PYROLYTIC” combustion have to have:
;
・ Refractory concrete:
§. Density: ≥ 100 mm
§. Nature: 42% of Al203
・ Shield in coarse panels:
§. Thickness: ≥ 75 mm
・ Nature: Calcium silicate.
* Burner of illumination of waste, with gas, common mono-bloc casting directing diving flame, lights and also safety of electronic ignition, irreversible air flow, electro-magnetic sluice entrance of regulation as well as isolating valve.
* Plate of burning in Carborundum, avoiding the dealing with of glass as well as slags.
A chamber of article burning of gases
* A heater of burning of gases,
* A device of shot of air enabling a complete recombustion of gases,
* A tool of air inlet of air conditioning of waste gases,
* A sheath of emptying of the gases charred.
* Carcass in solid sheet steel with support of link.
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc.