Tag: waste

 

Incineration is the most environmentally acceptable method of laboratory waste disposal.  Combustion of organic materials with excess oxygen at high temperatures for sufficient time results in degradation to elemental constituents or by-products that are easier to handle in an environmentally acceptable manner.  In addition to heat, the principle products of incineration are carbon dioxide, water, and oxides of sulfur and nitrogen; depending on what is burned, other volatile materials may also be formed.  Nonvolatile products include fly ash and solid residues.

Safe laboratory waste destruction is an ongoing challenge. With such a wide range of pollutants and particulates it is essential laboratory incinerators reach high temperatures to ensure total destruction of hazardous waste streams.Due to the secondary chamber with its 2 second retention period, the laboratory incinerator range is well suited to process all types of clinical & pathological waste such as: Solids (powder, pastes, pills, resins, sludge’s),Packaged wastes (boxes, drums, IBC’s, tubs),Confidential materials, Clinical waste, Controlled drugs, Laboratory chemicals, Reactive wastes,etc.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

1/ 200kgs/Hr medical waste incinerator.
2/ (CIF Term) Cost of shipping from factory to PAPUA NEW GUINEA seaport of LAE, Morobe province
3/ Cost of 2 Clover engineers to Supervise, Installation, Training our engineers and commissioning the medical; waste incinerator.
Electrically controlled incinerator.
Two-compartment incinerator with a capacity of 20 kg / hour.
Incinerator with low maintenance and operating costs; Equipped with an automatic control panel and easy to use with electromagnetic locking of the door.
A main waste reduction chamber of 900 ° C. A post secondary combustion chamber of gases generated in the primary chamber at least 1100 ° C.
Carbon residues in ash less than 5% by weight in accordance with European Directive 2000/76 / EC.
With refractory lining in materials of higher quality
waste incinerator that is bigger than YD.30c incinerator that have a 100kg loading capacity preferably in another hospital in Bayelsa State.Burn Rate-150Kg/hour minimum
Weight(Kg)-4000kg
Secondary Chamber(double chamber with post-burning)
Gas Retention Time 2 second
Fuel Diesel
Power Supply for control box 220V-240, single phase 50-60Hz
Minimum operating temperature 1200 oC
One year spare parts package for complete maintainability
10m hose pipe.
1100 litre fuel Tank +pipe system
Containerised (the container will serve as housing)
Additional chimney extension 1 metre high

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 5300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 300
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

Texas Ebola waste Won’t Be disposed in Louisiana

On Friday Attorney General Buddy Caldwell declared the State of Louisiana reached an arrangement with Texas incinerator Veolia Environmental Services and Louisiana toxic waste landfill Chemical Waste Management to ensure that incinerator ash associated with the recent Dallas Ebola virus occurrence won’t be transported or disposed of in Louisiana,.

On Oct. 13 the Louisiana Attorney General’s office got a restraining order in the 19th Judicial District Court to temporarily stop the transfer of incinerated Ebola ash into Louisiana. The temporary retraining order was extended on Oct. 21 at the request of all parties, until finally arriving at today’s arrangement.

Attorney General Caldwell stated,”I’m pleased today’s arrangement ends this chapter in the controversy of the transportation and disposal of Ebola waste”

Industrial Type Wastage Incinerator
Industrial Type Incinerator General Specification
i.System Capacity: 100KG/h
ii.Type of Waste: Municipal Waste (Paper, Plastic, Wood etc.)
iii.Waste Feeding: Manual
iv.Fuel: Natural Gas
v.Incinerator Type: Double Chamber
vi.Expernal Cladding: MS Sheet of suitable Gauge, Painted with corrosion resistant paint
vii.Flue Gas Emission Discharged to the Atmosphere should meet Pakistan National Environment Quality Standards (NEQS)
viii.User Friendly operation should be ensured by proper automation
ix.Adequate Safety Features should be incorporated to protect the premises and operators against mishaps and accidents 
Primary Chamber 
i.Auto ON/OFF Burner
ii.Auto Temperature Control
iii.Excess Air Blower Fan
iv.Chamber constructed of two layer refractory linging
v.Compressing: Thermal insulator linging and refractory masonry linging sufficient enough to maintain normal temperature at outside 
Secondary Chamber 
Primary Chamber
i.Auto ON/OFF Burner
ii.Auto Temperature Control 
iii.Excess Air Blower Fan
iv.The Chamber constructed of two layer refractory linging, comprising 
v.Thermal insulator linging and refractory masonry linging sufficient enough to maintain normal temperature at outside 
Control Panel 
Standard PLC Control Panel 
Note: All instruments/controller must be of high quality, preferably European/Japanese Origin
Chimnery/Stack
Made of MS Sheet, Sufficiently insulated and Lined with Refractory bricks (where required) to maintain normal temperature at outer surface 
Painted with High Quality 
Customer will be responsible for provision of electric supply and natural gas upto incinerator 
Heat and Corrosion Resistant Paint 
NOTE: 
Motors of all blowers/fans/pumps must be of high quality, preferably European/Japanese Origin 

waste incinerator means incineration the waste by incineration. we supply waste incinerator for medical hospital waste, pet cremation and animal incineration and other solid waste treatment. the waste incinerators have 2 combustion chamber, the first burner burn the waste in the primary combustion chamber and the other burner burn the smoke from primary combustion chamber. the smoke will be filtered by smoke filter chamber and then out. the waste incinerator use stainless steel chimney which is long life time and all the burner made in italy.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incinerator manufacturer china



incinerator manufacturer china

We are china incinerator manufacturer, contractor and exporter. Manufacturers create reasonable price for incinerator consumer, provide medical incinerator, hospital incinerator, creature incinerators, hog incinerators, pet cremation gear, little incinerator, pet incinerator, animal incinerator, mobile incinerator, little animal incinerator, infectious waste pyrolysis machine, lab incinerator. HICLOVER help customer decrease purchase budget, custom made function, quality products and friendly service.

low-cost medical waste incinerator is good idea for small clinic, small hospital, etc.Incineration is the only method providing complete destruction and neutralization of the medical waste ideally at the source. For developing country and regions, we support cheap cost budget customer to purchase the small scale incinerator, with basic function, burning rate 10kgs to 50kgs per hour capacity, single combustion chamber and three combustion chambers incinerator.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Laboratory  waste Management  system
01. Liqued water purification system.
02. Number of laboratories – 05
03. The estimated liquid water waste – 6000 L including
a. chemicals
b. toxins
c. Bio Hazardous materials.
Temporary allocated space for purifications system- 30×20
The following should be indicating in the biding document
1.Method of disposing treated waste water
2.Method of discarding the sludge
3.To follow ISO standard/regulations of Central Environment Authority[CEA]
4.Time frame for construction
5.Request the cost for each item of the project [Consultancy/designing/construction] as well for the whole project.
6.Warranty period and maintaincne. 
a. Pre-assembled, containerized type
b. Burning rate: 100 – 120kg / hour
c. Minimum operating temperature: 8500c (Primary combustion)
d. Maximum operating temperature: 14500c (afterburner chamber)
e. Secondary Burning capacity: Compulsory.
f. Density insulation: 20 mm high
g. Refractory casting: minimum 65mm
h. Heavy duty refracting lining to withstand 15000c
i. Average burn out time: maximum 3.0 hrs
j. Fuel type: fuel oil (diesel)
k. Fuel consumption in L/hr: 7.5 to 9
l. Residency time in secondary chamber: 2 secs.
m. Residue ash post 100kg Max 3.8 kg
n. Installation period Maximum 7days.

SPECIFICATIONS OF THE JKUAT INCINERATOR
It should  be  a three chambered incinerator 
The load capacity of 250 kg
The housing for the incinerator should be able to withstand the temperatures and other operational requirements.
The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc.
It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan.
The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion.
In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere.
A system for continuous emission Monitoring and Environmental Monitoring.
A mechanism with which to treat the waste water before discharge into the sewerage system.
Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation.
Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney).
High power electricity and emergency generator connection for automated ignition purposes.
The chimney should be tall enough and be at least one meter above the tallest building in the vicinity.
The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250.
Other Requirements
Training of all the personnel involved in health care waste (HCW) management.
The Automatic Feeding system of the Incinerator
Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber.
An Automatic bottom ashes discharge system.