Tag: waste

HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers



Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor



Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Form

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-07-27

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

General Waste Incinerator

For MSW

Mobile Incinerator(Optional)

Small-Middle scale, cellular function by

1. ) Wheel

2.) DC-Power Trolley

3.) Containerized

Wet Scrubber for Smoke Filter(Optional)

1. ) 1 Section Wet Scrubber

2.) 3 Fragrant Wet Scrubber

1 Section Wet Scrubber

S.S304 Cooling Spray tower

3 Sections Wet Scrubber

1.) S.S304 Dust Scrubber

3.) Front/Side Manual Loading

2.) Top Feeding Door(Optional)

3.) Auto. Feeding Door(Optional)

3rd Combustion Chamber(Optional)

 

Stainless Steel Main Body(Optional)

S.S201 or S.S304

Control Model

1.) Electric control box(Semi-automatic)

2.) PLC Auto.control box(Automatic)

 

Light Weight Upgrade(Optional)

 

W2E(Waste to Energy)(Optional)

Hot Water(Non-drinking water)

Fuel Burner

Italy Baltur Brand

4.) Both D.O and N.G/LPG(not 2in1 burner, swap burner kind )

Temperature Thermocouple

1.) K Type,Stainless Steel 1300(Standard)

2.) K Form,Corundum 1300(Optional)

3.)  S Form,Platinum Rhodium 1600(Optional)

Control Case Material

1.) Steel (Conventional )

2.) Stailess Steel(Optional)

 

Chimney/Stack

1.) Stailess Steel (Standard)

2.) Steel(Optional)

3.) Length(Optional)

4.) Thickness(Optional)

400x210x300cm

450x210x300cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-27



the animal waste incinerator design with 2 or 3 combustion chamber, different feeding door and combustion size for different animal size.

Items/Model A360 A600 A900 A1200
Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr.
Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs
Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs
Primary Chamber (Liters) 360 600 900 1200
Secondary Chamber (Liters) 200 200 300 500
External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360
Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90
Oil Tank(Liters) 200 200 300 300
Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80
Chimney (M) 5 5 5 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

Hazardous situation: Incinerators in K-P’s major hospitals from order

PESHAWAR:

Based on information gathered by the Environmental Protection Agency (EPA), 15 to 20 tons of hospital waste is made every day in the provincial capital alone. Nearly half of the total waste is recycled while the remainder is accumulated by the Peshawar Development Authority (PDA).

LRH

“To be truthful, we have one incinerator which is not in proper working condition and hardly disposes a quarter of the total waste generated,” said an official in Lady Reading Hospital while requesting anonymity. “But we have a new incinerator which will soon be functional.”

The officer, who didn’t know the specific figure of the waste created, said LRH has been one of the most popular hospitals across the nation. It has over 5,000 people (at least 3,000 in outpatient and 2,000 in accident and emergency departments) from across the province on a daily basis.

“The incinerator below process has some problems as some of its components are yet to be obtained,” said the official. “It also requires adequate gas–another significant issue –but we’re in touch with Sui Northern Gas Pipeline Limited (SNGPL).”

The LRH official added that the supply of gas to the hospital isn’t enough for sterilisation. He said the hospital government is connected with SNGPL authorities and the issue will soon be solved.

HMC

Hayatabad Medical Complex (HMC) Chief Executive Dr Mumtaz Marwat said the incinerator in HMC is out of sequence but it will burn some waste. “The left is gathered from the PDA and the hospital administration has approved Rs0.4million for a new incinerator, which will soon be installed”

“Together with all the solid waste created by KTH, we also recycle waste that comes from some private hospitals at University Town,” said Roghani.

The EPA has already sent a written notice to the health directorate, asking it to correctly dispose of medical waste as stated beneath Hospital Waste Management Rules 2005. These say the duty of waste management is based solely with the magician that created it.

What occurs following

Actually if the incinerators at these hospitals have been repaired, the issue of unattended dump is very likely to persist. This is largely due to the tiny personal health centers which lack the fundamental knowledge and dispose of their waste as’municipal waste’. The ever-increasing amount of such centers is directly proportional to the waste created, making it a threat for the surroundings as at times that the waste is just left in a pile or buried to groundwater.

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 Squander



Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 



the animal incinerator china made with cement or fire brick combustion chambers. one type animal incinerator china is for family pets and other type is for animal waste.

Smallest Waste Incinerator for PPE waste face mask glove Squander



Smallest Waste Incinerator for PPE waste face mask glove waste
Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney
ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications

Model

YD-10

Picture

 

Feed Capacity

Average 20 kgs per feeding

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Gas

Diesel Petroleum

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

Ave. 4.2 Kgs/Hour

External Dimensions

Dia.100 x 130cm (mainbody)

Internal Dimensions

Dia.50 x 80cm

Waste combustion chamber

200Liters

Oil Tank Capacity

100 Liters

Door Opening

35 x 35cm

Chimney

1.5M

Gross Weight

Ave.400kgs

Chamber Material

Refractory Concrete&Ceramic Fiber 

Max.

42,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

14000C

Burning efficiency

>98%

Waste Lower Calorific Power

3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 



The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world. animal incinerator cost is key point for pet cremation business owners. our pet incineration equipment made with double combustion chamber, waste oil collect function, movable feeding door.

Items/Model A360 A600 A900 A1200
Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr.
Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs
Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs
Primary Chamber (Liters) 360 600 900 1200
Secondary Chamber (Liters) 200 200 300 500
External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360
Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90
Oil Tank(Liters) 200 200 300 300
Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80
Chimney (M) 5 5 5 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower



Model

YD-150

Burning Rate

Typical 150 kgs/hour

Feed Capacity

Average 300 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Gas Form

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17–36 kg/hour

Gas Consumption (Natural Gas)

11–36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary Room )

External Dimensions

240 x 170 x 380cm (without chimney)

Infection Monitor

Yes

Oil Tank Capacity(if oil Gas )

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

before start the 2nd burner, full close all air valve on the 1st chamber. other operation keep same. 
reason: at the first 10-20 min burnning the plactic waste, deflagration combustion in the chamber. 
after 10-20 min, gradually increase air injection by air valve on the 1st chamber.
meanwhile, proposal 20-30 min burnning of the 1st chamber, stop the 1st burner(stop fire only, the fan inside the burner 
still working), let the plastic burn itself(Spontaneous combustion) to save diesel oil.
a small waste to energy project to turn municipal solid waste 

7500 kgs

Model

YD-150

Main Product List

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Smoke Filter Chamber(Dry Scrubber)

 

Incinerator Control Case(PLC Auto.Type)

 

Chimney:10.0Meters

Chimney (upgrade to Stainless Steel, free Price )

 

Italy oil/gas burner: 02 sets

 

Oil Tank (if oil fuel): 300Liters

 

Optional Part:

Stainless Steel Wet scrubber(Cooling Spray Coating )

into electricity. The project is to cater for a local council with a population of around 60,000 people and will serve as a 
pilot project. If project is successful than other such plants will be installed in other towns and villages. The villages 
will all cater for the MSW in their locality instead of a central large incineration plant to cate for the whole county.for a 7 ton per 
hour plant on turn-key basis with your best price and delivery including full technical specifications, literature, drawings 
and best export price.
Provided you can offer a good solution there is a chance of selling many more such plants for the local councils of the same 
country, so this is an excellent chance for you to join forces with our company for market penetration with your products in 
Europe.
1. TS100 model with dry scrubber system
2. YD150 with a wet scrubber system

 

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 



Incinerator burn medical and bio waste



Incinerator burn medical and bio waste

Items/Model

TS100(PLC)

Picture

 

Principle

Medical  Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V/380V

Power

0.7Kw

Oil Infection (kg/hour)

average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

10Meter

Chimney Sort

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 



we are animal waste incinerator manufacturer, the combustion chamber volume up to 5.5m3 for big animal and also make small incinerator for pets and small animals.

Items/Model A360 A600 A900 A1200
Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr.
Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs
Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs
Primary Chamber (Liters) 360 600 900 1200
Secondary Chamber (Liters) 200 200 300 500
External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360
Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90
Oil Tank(Liters) 200 200 300 300
Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80
Chimney (M) 5 5 5 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃