Tag: Waste Incinerators

Medical Waste Burner Capability Requirement 100kgs per hr


Temperature Level Show & & & & PLC Control Instance

Main Burning Chamber

Incinerator Text

Italy Oil/Gas Heating Unit

***Primary Combustion Chamber

*** 2nd Burning Chamber *** Smoke Filter Chamber

***Chimney:10.0Meters

*** Heater PLC Control Circumstances

***Italy oil/gas burner: 02 units
***Oil Tank (if oil fuel): 200Liters


Items/Model

TS100( PLC)

Principle

Waste Incineration Therapy

Melt Cost

Standard 100 kg/hour

Feed Capacity

Average 200kg/feeding

Control Mode

PLC( Programmable Thinking Controller Incinerator)

Burning Chamber

1200L

Inner Measurements

120x100x100cm

Extra Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Mode

Guidebook

Voltage

220V

Power

0.7 Kw

Oil Usage (kg/hour)

14—- 28

Gas Usage (m3/hour)

10—- 32.2

Temperature Display

Digital Program

Temperature Defense

Yes

Oil Tank

200L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃—- -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Outside Measurements

260x150x180cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-16


Containerized Mobile Incinerator Version CA50


Waste Burner

(Containerized Mobile Heater)

Ability: Normal 50 kgs per human resources


Style

CA50

Inside Dimensions

100 x 80 x 70 centimeters

Main Product Listing

Main Burning Chamber

Added Burning Chamber

Smoke Filter Chamber

Heater Control Situation

Smokeshaft:5.0 Meters

*( upgrade to Stainless-steel, cost-free rate)

Italy oil/gas heater: 02 systems

Oil Container (if oil gas): 200Liters

ISO 20′ ′ ′ ′ Container( Shipment with Burner)














Variation

CA50

Waste Treatment

Waste Incineration Treatment

Feed Capacity

Regular 100 kgs per feed

Burning Price

Regular 50 kgs per hr

Burning Time per Feed

Criterion 2 hour

Control Setting

PLC( Programmable Logic Controller Incinerator)

Voltage

220V

Power

0.7 Kw

Fuel

Diesel oil

Burner

Italy Heater

Feed Mode

Guidebook

Temperature Level Screen

Digital Present

Gas intake (Oil)

Normal 16.6 Kgs/Hour

Inner Dimensions

100x80x70cm (Key Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Blog Post Combustion Chamber

280Liters

Oil Container Capacity

200 Litres

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Item

Firebrick, Refractory Concrete

Max. Warmth Worth

166,000 Kcal/Hr.

























HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-15


Design TS30 oil ended waste tiny burner 30kgs


Model TS30 oil fired waste small incinerator 30kgs/hr.

Items/Model

TS30( PLC)

Picture

Melt Price

Typical 20-30 kg/hour

Feed Capacity

Normal 60kg per feeding

Control Establishing

PLC( Programmable Thinking Controller Incinerator)

Burning Chamber

330L

Inner Measurements

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Establishing

Manual Feeding

Voltage

220V

Power

0.5 Kw

Oil Usage (kg/hour)

Average 13.3

Gas Consumption (N.G, m3n/Hour)

Typical 16

Gas Intake (L.P.G, m3n/Hour)

Average 11.7

Temperature Level Screen

Four Digital Present

Temperature Defense

Yes

Oil Storage Tank

100L or Even More( Optional)

Feed Door

55x50cm

Smokeshaft

5Meter or More( Optional)

Chimney Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– – – -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4000kg

Outdoors Dimensions

175x120x140cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-14


50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview


This model is small-scale waste incineration equipment for small waste output. 

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate
Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people
— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Hiclover waste burner


Key Features:

— — — — Complete selection burner with Saved money Tiny Scale burner, Standard Small-Large Range heater,

General Municipal Solid Waste Heater, Family members Pet dog and likewise Pet Cremation, Containerized Mobile Burner,

High Effective Environmental Waste Burner.

— Single combustion chamber, double combustion chambers, three combustion chambers and 

multi-combustion chambers waste incinerators.

— System solutions for medical waste environmental.

— High burn rate, from 5kgs to 1000kgs per hour.

— New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental 

protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We provide singular combustion chamber, double burning chambers, 3 melting chambers and also

multi-combustion chambers waste heaters for laboratory, facility, health center, clinical facility, wellness

scientific waste destruction with clinical non reusable, organic waste, clinical plastic waste, contaminated materials,

red bag waste, needle disposal, gauze and also plasters, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, and so forth.

Our range of incinerators offer small to huge array pet dog cremation connected organizations, such as chicken cattle ranches,

ranches, lamb ranches, pig farms, stables, kennels, testing laboratory, catteries, animal crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber 

again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, 

high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste 

package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet 

cremation business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no 

incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, 

Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner 

for governmental organizations, non-profit organizations, international contractors, logistics organizations, 

military, pet cremation business owners, etc. We have export experience more than 40 countries, including 

war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china heater maker, professional in addition to merchant. Maker clear up expense for

incinerator consumer, supply medical heater, clinical center heater, animal incinerators, hog burners,

household pet dog cremation gadgets, tiny heater, family pet burner, animal incinerator, portable burner, little

pet incinerator, infectious waste pyrolysis tools, lab incinerator. HICLOVER aid client

reduce purchase budget, tailor-made made function, top-notch items and also pleasant remedy.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-12


50-100-150-200 Kgs per Hr Solid Waste Incinerator for sale


Waste Incinerator Design TS150 PLC, Testimonial

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate
Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people
— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:

Items/Model


TS150( PLC)

Photo

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*( 50/100/200kgs/ hr optional)

Feed Capability

Standard 750kg/feeding

Control Establishing

PLC( Programmable Logic Controller Heater)

Text Steel

8mm thickness

Chamber Product

High Alumina Fire Block Wall, 1750 ℃ Rate

Paint for outdoors face

800 ° C Rate

Burning Chamber

1570L

Internal Dimensions

150x100x105cm

2nd Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (kg/hour)

Common 20.4-28.0( D.O)

Gas Intake (m3/hour)

***

Temperature Level Screen

Digital Program

Temperature Level Safety

Yes

Oil Container

300L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Type

Stainless-steel

1st.

Gross Weight

8500kg

Outside Dimensions

300x160x280cm( without smokeshaft)

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without smokeshaft)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


animal incinerators

The incinerator shall be equipped with a Diesel oil tank that will be supplied with DO from our DO tank located in the

power station. The tank shall be equipped with level switches and appropriate solenoid valves for automatic filling of

the tank. The tank shall also be equipped with a magnetic level indicator, level switches and appropriate drain valves,

separate overflow and vent pipes.

Oil-fired multi-stage waste incinerator of pyrolytic type shall be installed complete with interconnecting flue gas

ductwork between the incinerator and the chimney outlet.

 

The unit shall be manufactured in accordance with the latest ASME code, BS and DIN standards.

 

The waste disposal shall be environmentally acceptable and the incineration emission shall comply with the admissible

emission limits (international EC-Standards). The visibility of flue gases shall not exceed one Ringelmann. The waste

shall be completely burnt and the content of un burnt organic matter of the ash shall not exceed 3%.

 

The unit shall allow for a minimum of 2.0 seconds retention time.

 

1.2        QUALITY ASSURANCE:

 

  1. Coordinate the entire assembly of incinerator, stack, controls, fuel supply.

 

  1. Provide written certification that the entire assembly has been coordinated to achieve the required performance

and to provide the required features.

 

  1. Equipment, installation, and operation shall conform to NFPA 82. Where conflicts exist between NFPA 82 and this

specification, this specification shall govern.

 

1.3        SUBMITTALS:

 

  1. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

 

  1. Incinerator:

 

  1. Arrangement, description of construction, and outline drawings of incinerator and accessories showing

clearances and dimensions.

 

  1. Predicted performance including burn time based on waste composition specified.

 

  1. Calculation of secondary chamber retention time.

Waste Incineration Therapy Style TS75( PLC).


Average 50-100 kg/hour Burn Rate

Items/Model

TS75( PLC)

Principle

Waste Incineration Therapy

Burn Cost

Average 50-100 kg/hour

Feed Ability

Ordinary 200-300 kg/feeding

Control Mode

PLC( Programmable Reasoning Controller Burner)

Face Oil Paint

800 ℃

Combustion Chamber

768 Liters (0.768 M3)

Inner Measurements

1200x800x800mm

Added Chamber

384 Liters (0.384 M3)

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

210/240V 50Hz 1P

Power

1.3 Kw

Oil Intake (kg/hour)

Typical 20.4( D.O)

Thermal ability( kw/hour)

166-332

Gas Consumption (m3/hour)

***

Temperature Level Degree Monitor

Digital Show

Oil Tank

3000L

Feed Door

60x50cm

Smokeshaft

10Meter

Chimney Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– – – -1000 ℃

2nd. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

7500kg

Outside Dimensions

260x160x250cm( without smokeshaft)

We offer singular burning chamber, dual combustion chambers, 3 burning chambers and multi-combustion

chambers waste incinerators for lab, center, clinical facility, clinical facility, hygiene specialist waste devastation with scientific

non reusable, organic waste, clinical plastic waste, contaminated materials, red bag waste, needle disposal, gauze and additionally plasters,

secured sharp containers, pathological waste, trace-chemotherapeutic wastes, and so forth.

Our collection of incinerators provide for little to big range family pet cremation relevant business, such as fowl ranches, livestock

ranches, lamb ranches, pig ranches, stables, kennels, screening laboratory, catteries, pet dog crematoriums. Vendor clear up rate for incinerator consumer,

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to 

make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature 

sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation 

business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house 

build construction, movable by truck and ultraviolet lamp sterilization inside.

We are growing brand for environmental protection field, and market share with most of 

Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental 

organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. 

We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

supply clinical burner, medical center burner, family pet burners, hog burners, pet dog cremation tools, small incinerator,

pet dog burner, pet dog burner, mobile burner, little pet dog burner, transmittable waste pyrolysis tool, lab

heater.

burner.


250kgs per human resources capacity waste incinerator


Burner Design TS250 PLC, Review

This design is small waste incineration tools for little waste result. Construction

is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. 
Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers
and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. 

Key Product Listing per 01 collection

Key Burning Chamber

Extra Combustion Chamber

Smoke Filter Chamber

Incinerator PLC Control Circumstances

Smokeshaft:10.0 Meters

*( upgrade to Stainless-steel, complimentary cost)

Italy oil/gas heater: 02 systems

Oil Container (if oil fuel): 300Liters








Items/Model

TS200( PLC)

Image

Principle

Solid Waste Incineration Therapy

Melt Price

Average 250 kg/hour

Feed Ability

Requirement 350kg/feeding

Control Establishing

PLC( Programmable Logic Controller Burner)

Burning Chamber

1800L

Internal Measurements

150x110x110cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Power

0.9 Kw

Oil Intake (kg/hour)

Common 28

Gas Usage (m3/hour)

Typical 33.6

Temperature Level Display

Digital Existing

Temperature Level Degree Security

Yes

Oil Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– – – -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x190cm

Heater procedure should certainly be Automatic On/Off

Gas: diesel

The supplier need to supply needed details for the very best of the installment

This burner with “PYROLYTIC” burning need to have:

;

・ Refractory concrete:

§. Thickness: ≥ 100 mm

§. Nature: 42% of Al203

・ Guard in coarse panels:

§. Thickness: ≥ 75 mm

・ Nature: Calcium silicate.

* Heater of illumination of waste, with gas, typical mono-bloc casting directing diving flame, lights and additionally safety and security of digital ignition, permanent air circulation, electro-magnetic sluice entry of guideline in addition to isolating valve.

* Plate of burning in Carborundum, staying clear of the taking care of glass along with slags.

A chamber of short article burning of gases

* A heating system of burning of gases,

* A gadget of shot of air making it possible for a total recombustion of gases,

* A device of air inlet of air conditioning of waste gases,

* A sheath of clearing of the gases charred.

* Carcass in solid sheet steel with assistance of web link.

* Structure of the refractory;

・ Refractory concrete:

§ Thickness: ≥ 150 mm

§ Nature: 65% of Al203

・ Protect in rugged panel:

§ Thickness: ≥ 85 mm

Nature: Calcium




burner manufacturer 200kgs/h


Waste is thermally rotted in the main chamber at temperature degrees of 800 ° C +. The resulting aeriform products are entirely oxidized in the second chamber at higher temperature levels with ample resident time. Various other specs are as adheres to. A burning chamber of waste:

* Flawlessly limited door for the hands-on loading of waste. The filling should certainly be Handbook, Set Tons

* A heater of lights which the use is restricted to the ignition of waste.

* Frontage of packing with door seals risen on hinges, wheel of screw plug, versatile joint, in addition to packing securing out of refractory.

* The insulation of the burning chamber need to be comprised of refractory blocks, having a high internet material of light weight aluminum as well as guards blocks in order to assure a minimum temperature level on the outside sheet steel.

* Composition of the refractory

Burning Capability

Max. 200kgs/h

Supporting Gas

Diesel

Kind of Heating Unit

Monoblock automatic heating units

Temperatures

Key Chamber: 800 ° C ± 50 ° C. Extra Chamber: 1300 ° C ±

50 ° C. Kind.

240 W.

Pump pressure.

* Make-up of the refractory

Burning Capacity

Max. 200kgs/h

Sustaining Gas

Diesel

Kind of Heating System

Monoblock automated heating systems

Temperatures

Main Chamber: 800 ° C ± 50 ° C. Extra Chamber: 1300 ° C ±

50 ° C. Kind.

Refractory thickness.

240 W.

Pump stress.

Refractory thickness.

115 mm thick.

Product.

Refractory blocks.

Insulation density.

50 mm thick.

Type.

Centrifugal.

Inflection.

Manual damper control.

Product of Construction.

Mild Steel.

Sort of temperature controller.

Digital.

End up & & paint kind.

Dual coat.

Material of construction & & capacity

. Mild Steel/ Plastic, appropriate capacity.

Other Standard Accessories.

Diesel oil degree sign, piping with shutoffs & & Non-return shutoff.

Aesthetic Monitoring of Gas.

Offered.

No. of Burners.

2 one in primary and also in second chamber).

Type & & Design

. Monoblock automated oil fired.

Make.

Riello.

Fuel.

Diesel.

Fuel shipment.

10 C 20 kg/h.

Discharging phase.

1.

Thermal power.

118 C 236 kW.

Motor power.

240 W.

Pump pressure.

10 C 12 bar (basic calibration), Max. pressure 15 bar.

Electrical supply.

Single phase 220V, 50Hz.

Material of building and construction.

Burned bricks.

Height.

9 meters from ground degree.