Tag: waste-incinerator

incinerate biohazard waste

It is not meant to use any fuel, such as gas or oil, to promote the burning of the waste, since the waste products need to be incinerated with a free burning process. Hot air however from a downstream process will be available to increase the incinerator temperature and burning rate as required. Very high temperatures in the incinerator are not necessary and are not required.

The burning of these waste products is expected to produce toxic emissions that will be cleaned via other existing downstream processes and a Post Combustion process in the incinerator is therefore not required.

The incinerator should be capable of accommodating an automatic waste feed process.We are looking for incinerator to incinerate biohazard waste of our microbiology laboratory. Our daily waste production is upto 20 Kg maximum and incinerator will be required on weekly basis that is 1 or 2 times a week so you are therefore requested to kindly suggest the right incinerator for our laboratory which shall be cost effective for us regarding buying and maintenance cost.

The incinerator should be capable of accommodating an automatic waste feed process.We are looking for incinerator to incinerate biohazard waste of our microbiology lab. Our daily waste production is upto 20 Kg maximum and incinerator will be required on weekly basis that is 1 or 2 times a week so you are therefore requested to kindly suggest the appropriate incinerator for our lab which shall be cost effective for us regarding purchasing and maintenance cost.

Hiclover bio waste incineration

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste
Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*:
heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of 
non-combustible fines below 20%; moisture content below 30% by weight
Combustion performance: The medica waste incinerator shall be capable of reducing waste to ash not exceeding 10% of the total combustible 
charges.
Outdoor installation. The medical waste incinerator will be installed outdoors. All incinerator components shall be suitable for but not 
limited to outdoor shaded installation, including electric motors, be resistent to corrosion, moisture and related weather elements.

※Main Feature:— Dual Combustion Chamber— Dual Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3— Mobile Incinerator, Standard shipping containers, Easy to move/transport system— Free Installation, Pre-installed incinerator, Ideal for Decks — Ultraviolet lamp sterilization inside

Materials of construction: The incinerator shall Have No asbestos, asbestos-containing substances, mercury thermometers, and mercury switches. 


WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Kinds of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator

Nanjing Clover Medical Technology Co.,Ltd..

an industrial sized incinerator for tobacco and tobacco waste

Brand = Any

Model = Any

400v/50hz

·        Forms of waste – woods, tree branches, tree leaves, wood powder and card boards

·        Daily Hours of operation  7 hours

·        daily create waste capacity = 10000kg
ELECTRIC UNIT SHOULD BE DELIVERD WITH SERVIC MANUAL IN ENGLISH FOR EACH ONE
In the Event of ORDER I NEED
2what is the capacity of burner in 1 hour?
For creatures to 90 kg. Size dogs until 80 kg )1. Technical specification is for burner only
Oil Tank 100Liters, 1 place

inciner8ter model TS50 OR TS100 With  delevery in Europe stare Croatia.Please can you send me the offer for pet crematory equipment.details of Chemical waste incinerator.
COMMERCAL INVOICE( LEGALIZED FRO CHAMPER OF COMMERCE)
should BE SEND  SOME ONE FOR FIXE AND  TRANING    FOR 5 PERSON IN EACH LOCATION
Thermal Gasket, 10 Meters
DELIVER TIME ASB
TWO ORGINAL  BILL OF LADIN
AWITING YOUR  GOOD REPLY

A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE

SPECIFICATIONS OF A PYROLYTIC MEDICAL WASTE INCINERATOR FOR LARGE SCALE

23.     The provider must give batches of spare pieces of first urgency and consumable of the incinerator.
•    Insulate in fibrous panels :

▪    . Thickness: ≥75 mm
*    The insulation of the combustion chamber should be composed of refractory bricks, using a high content of aluminum and insulates bricks so as to assure a minimum temperature on
2.    
17.    
•    Post combustion: >1100oC.
*    Electric box.

21.     The de- ashing must be completed in the base of the combustion chamber or the deashing should be Automatic or manual batch de ashing.
*    A timer with flexible temporization for the regulation of each burner.
*    Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
13.     The Dimension of the door for loading in cm: 120×120.
*    A device of injection of air allowing a Whole recombustion of gases,
Load
Control box watertight to dust, such as:

*    A switch circuit breaker for each engine (ventilators and burners).
25. The technical training of operators will have to be provided and given by a technician from the mill; it will include curative and preventive maintenance, and the use of machine, etc

NB.: Civil works and any other relevant services for the installation and training of operators have to be included in the incinerator’s price.

21.     Fan:
*    Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch
*    Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

factory installed Diesel Fired Incinerator

Estimados, agradecería una cotización por los hornos crematorios para mascotas modelo YD-30 / YD-50.Mobile Diesel Fired  Incinerator model
supplied with the following specifications:
complete with constant ventilation fans for extraction,
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model plan to build a incinerator plant with 3 units of incinerators at the capacity of 500kg per hour each.
Together with other facilities like operation office, store, space to clean waste containers and 3-4 worker living quarters.
Necesito saber
1.ficha tecnida
2.guía mecanica
3.elevaciones
4. Los quemadores son Ecologicos.??  5.’caracteristicas generales
Del YD 50  and. YD 100  Long Life pet crematory
in Diesel ….Me interesa este producto  Long Life Pet Crematory (YD-50), y quiero conocer más detalles sobre:
Dame la lista de precios exactos por favor.
Me gustaría pedir algunas muestras. ¿Podría  enviarme la lista de precios de muestras?Raw Medical Waste Incinerators. Can you please provide an official cost quote for purchase of (2) incinerators, whichever model has a comparable Capacity = 30 kg/hr.

Incinerator capacity of destruction of 350 kg/hour

– Incinerator capacity of destruction of 350 kg/hour, calorific value of waste will be 13-25 MJ/kg

[3,500 kcal/kg] and maximum heat capacity 1,225,000 kcal/hr.

– Incinerator destruction capacity will be 8.4 tons/day and performance time will be 24 hr. /day.

– Waste will be through automatic feeding system into the incinerator.

-The temperature will modulated in varying flow and percent in oxygen, combustion gas is re-burned

from the re-combustion[secondary] chamber at a temperature of minimum 1,100 C during 2 minutes.

– Control panel will be fitted with a practical synoptic view showing the working situation of the whole

incinerator and controlled by DCS/PLC system.

– Gas treatment system will honor the EE standard [Directive 2000/76/EC-4/12/2000.

– TOC of slag and bottom ashes will be 3% of the dry weight.

– Installation will be totally free from visible smoke.

– Incinerator will be designed as a Packaged unit, having electrical connection pre-wired and closing pipes

set up.

– Incinerator will have automatic de-ashing system with upward direction.

– Incinerator will have flue gas treatment system inclusive [emergency by-pass stack, gas heating system,

two reactors and particulates filtering system] and guarantee of emissions out of incinerator.

– Training of AKU staffs at website.

– Site may be inspected and examine existing ATI machine, capacity 150 kg/hr. in 24 hour operation.

– Present infrastructure space is available in cellar, 100′ Length  x 30′ wide x 20′ Height for 2nd Incinerator.

– Present chimney length is 12 meter, and width is 24″dia.

– Existing chimney length is 12 meter, and width is 24”dia.