Tag: waste-incinerator

Small scale incinerator of burning capability

Poultry Incinerator – 400 kgs feed per day.a small scale incinerator of burning capacity 30kg/hr=1No. Note that it should be portable as this is meant for oil fields work on tented camps. Also it has to be diesel operated as our location is remote. 150!kg per hour LPG smokeless incinerator to be used at the international airport. This is a requirement bu the bio security that all international flights need all rubbish burnt within a set time.Required load capacity is 150Kg
Chamber – Primar 900 liters Secondary: 300Litres
Chimney 8M
Burning Rate: 50kgs/hr    Yes
Feed Capacity: 150kgs    Yes
Primary Combustion Chamber: 900 litres    Yes
Secondary Combustion Chamber: 300 litres    Yes
Mix Combustion Chamber: Yes    Yes
Smoke Filter Chamber: Yes    Yes
Feed Mode: Manual    Yes
Power: 0.7Kw    Yes
Fuel Type: Diesel Oil/ Natural Gas/LPG    Yes. Different Price if oil or gas fuel.
Internal Dimensions: 120 x 90 x 85cm (primary chamber)    Yes
External Dimensions: 200 x 160 x 310cm (without chimney)    Yes
Burning Efficiency: >98%    Yes

ecologically friendly incinerator

50 bed hospital and would love to have your recommendation for incinerator that can effectively deal with the load of 50 bed hospital.Incinerator for burnable garbage (paper & organic) medium capacity (100/150 lts).  Bio Medical Waste Incinerators,

Capacity: 50kgs per hour Medical Waste Incinerator  Model  TS50 ( PLC ) with both choice on Fuel ( Natural Gas and / or Diesel2 Burners
2 Temperature Thermocouple
5 meters for thermal gasket

500kg/day burn capacity incinerator

in acinerator with 300 kg/ hour by dual filter wet and dry.Pet Dead Body Incinerator upto 80 kg,gas operated is prefered.  animal waste incinerator with capacity about 40Kgs. We will use this product to burn the animal corpses in normal way (not ill aninal).Could you please forward me quote for incinerator that is suitable for service Town with a population of 200,000 people including other general city waste to burn.  Technical specifications data sheet
List and quantities of consumables required per month
List and prices of all the spares required in 5 yrs
List and prices of all the spares required in 10 yrs

2 incinerators one with 500kg/day burn capacity another one with 1000kg/day burn capacity

1 x Electrode

1 x Fuel Filter

1 x Photocell

1 x Flexible pipe

1 x Nozzle

1 x controller Box

Incinerators that could handle Bio-Medical waste red bag

incinerators that could manage Bio-Medical waste (red bag) from research labs with level 2 and 3, animal research, and hospitals.  There are also a small quantity of Pharmaceutical waste to be destroyed.  I’d like your recommendations on what incinerators would manage these requirement based on the next monthly kilograms of substance.

 

Website 1 — 4,650Kgs a month (I’ve recommend I put in two incinerators at this place since it is a medical research facility and the use is very large )

 

Website 2 — 1000Kgs per month (this facility deals more with animal research but also has red bag waste from their research side, they now have a large animal carouse incinerator)

 

Website 3 — 1000Kgs per month (this facility is a local hospital with bio-waste from treating patients)

About Medical Waste

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses.


HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.

Average 20%-25% of the total waste generated by Health Care establishments is regarded as Poisonous and may create a variety of health and environmental risks if not Handled and destroyed in an appropriate manner. 

Our products ensure effective, clean and hassle-free disposal of medical waste is possible.  The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies, Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.

○Middle-Small Capacity(TS Model)※Main Features:— Dual Combustion Chamber— Dual Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Upgrade/Downgrade Burning Rate
○Large-Middle Capacity(YD Model)
※Main Feature:
–Three Combustion Chambers
— Double Italy Burner
–Burning Rate: 30-600kgs per hour
–Combustion Chamber: 0.36M3-5.5M3
※Optional Function/Parts/Material/Burning Rate: 
— Stainless Steel Chimney 
— Dry Smoke Filter Chamber
— Chimney Height Custom Made
— Semi-Automatic Waste Feeding
— 3-Section Wet Scrubber System
— Movable Platform Feeding Door
— Additional Burner
— Upgrade/Downgrade Burning Rate

● Service before and after Installation — Factory training for installation, operational and maintenance with free cost. — Online service support for setup, operational and maintenance with free cost. — Onsite installation, operational and maintenance training— Onsite service support after installation

● Spare parts supportHICLOVER offers spare parts such as:— Burners (diesel oil, LPG or natural gas)—   Element for burners— Fire ropes— Incinerator chamber maintenance stuff — Air Fan — Temperature element—   Smoke filter brick—  Control box—  Other parts 

Nanjing Clover Medical Technology Co.,Ltd..

Tel:  +86-25-8461 0201    Fax: +86-25-8461 0406

Hazardous Waste Incinerators

Basic Info.

Model NO.:furnace for incineration of animal waste
Export Markets:Global

Product Description

Key Features: 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Burners that can deal with Bio-Medical waste red tote

burners that can manage Bio-Medical waste (red bag) from research laboratories with level 2 as well as 3, pet research, and wellness centers. There are additionally a small amount of Pharmaceutical waste to be ruined. I would certainly enjoy your referrals on what burners would certainly deal with the these requirement based upon the adhering to regular monthly kgs of substance.

Site 1– 4,650 Kgs monthly (I have suggest that I set up two incinerators at this place given that it is a medical study centre and the use is very high)

Site 2– 1000Kgs each month (this facility deals more with animal research however also has red bag waste from their research study side, they presently have a Massive creature carouse burner)

Website 3– 1000Kgs per month (this centre is a neighborhood healthcare facility with bio-waste from treating individuals )

500kg/day melt capacity burner

in acinerator with 300 kg/ hour by double filter wet in addition to dry.Pet Cadaver Incinerator upto 80 kg, gas operated is prefered. We’ll use this thing to melt down the pet corpses in typical method (not ill aninal). Could you please forward me quote for burner that appropriates for service Town with a people of 200,000 individuals consisting of other general community waste to lose. Technical requirements information sheet
List along with expenses of all the spares required in 5 yrs
Checklist and also expenses of all the spares known for in Ten Years

two incinerators one with 500kg/day burn capacity another one with 1000kg/day melt capacity

1 x Electrode

1 x Fuel Filter

1 x Photocell

1 x Versatile pipeline

1 x Nozzle

1 x controller Box