50 to 60kg/hr and 100 to 120kg/hr diesel powered incinerator
50 to 60kg/hr and 100 into 120kg/hr diesel powered incinerator.1. 2. Required Incinerating Capacity:
Approximately 4,500 tons per year. The incinerator must capable of incinerating type of waste mentioned or any combinations thereof at a rate of 3 mph. The machine shall be designed to operate for at least five consecutive times nonstop if required.
3. Incinerator Design Requirements:
The system should be simple in design and operation, with minimal electronic components.
3.1 Specific Data that must be offered with the Design
3.1.1 Incinerator Data:
a.Batch Load Capacity;
b.Primary chamber design (thickness, diameter, length, insulation, lining, volume hearth area, weight); c. Secondary chamber design (thickness, diameter, length, insulation, lining, quantity hearth area, weight);
c.Exhaust stack layout (thickness, diameter, lining variety of segments, complete stack length, height above base, weight);
d.Type and amount of auxiliary fuel burners;
e.Fuel requirements — type, amounts;
f.Electrical power use;
g.Electrical services required;
h.Water requirements — amounts;
i.Any other input requirements and consumables;
j.Temperatures to be achieved to guarantee suitable destruction of waste and comply with required air pollution control standards (EU Waste Incineration Directive 2000/76);
k.Residence time to ensure suitable destruction of waste and comply with required air pollution control standards;
l.Potential weight loss (percent ) of waste;
m.Options to automatically and continuously monitor and record information such as dates, time of day, batch sequential number;
n.A temperature or visual indicator to display heat status of gear; and
o.Details on picture displays and / or computer recording apparatus.
3.1.2 Air Pollution Control System Data
a.The type of air pollution control equipment selected will comply with EU WID Waste Incineration
b.Directive 2000/76;
c.Details about the gas cleaning systems to improve the removal of fine particles, acid fumes and heavy
d.metals;
e.Details on components, such as:
quencher;
condenser / absorber;
venturi scrubber;
entrainment separator and
emissions pile (s).
Electrical power use;
f.Any other input demands and consumables (e.g. lime);
g.Details on graphic screens and / or computer recording apparatus;
h.Environmental requirements – The system will have the capacity / capability to comply with relevant air quality criteria; i.e.EU Waste Incineration Directive 2000/76. (or similar standards and criteria acceptable to the Australian Commonwealth Government Department of the Environment);
i.Specify air pollution parameters that are monitored.
3.1.3 Site Requirements for the Incinerator
a.Total land area dimentions;
b.Infrastructure required ( water supply, power supply drainage); and
c.Any specific ecological or climatic/meteorological aspects that needs consideration.
3.1.4 Housing Requirements and Design
a.Details on demands for a safe enclosure to the incinerator and associated air pollution control system. The enclosure will be designed to achieve occupational health and safety requirements such as: a. Free space can be found on either side and heat radiation is kept at a minimum giving the operators an:
b.easy viable environment and ventilation;
c.There are protected storage facilities for waste;
d.There are measures to avoid vermin and insects;
e.The materials are of sufficient structural depth for safety and to withstand sea corrosion.
4. Training, Maintenance And Instruction Manuals
4.1 Maintenance Manuals
Provide details on maintenance requirements, such as:
a.General cleaning and maintenance — frequency, skills / specialized experience required;
b.Expected life span of parts and the system as a whole;
c.Expected frequency of the requirement for replacement of parts;
d.Availability of parts and location of providers;
e.Frequency of need for major overhauls; and
f.Estimated down time needed for general maintenance and major overhauls.an incinerator for our deceased animals in the farm particularly chicken.
incinerator manufacturer 200kgs/h
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident moment. A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of light which the use is limited to the ignition of waste.
* Frontage of loading door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating from refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks to be able to assure a minimum temperature on the exterior sheet metal.
Burning Capacity
Max. 200kgs/h
Auxiliary Fuel
Put in a diesel fired incinerator
incinerate mainly pharmaceuticals ( all types of dosage forms … syrups, tablets, injectables ) medical consummabables, and also biological fluids …
1.3FIELD TRAINING
Test the incinerator under actual firing conditions. Verify with analyzing that all controls function within the minimum and maximum limits for temperature or time. Simulate actual unsafe conditions such as high temperatures and flame failure by decreasing the settings for the activation of limit and safety controls.
Run the incinerator under normal load conditions for not less than 6 hours. After 6 hours, temperature readings of the outer shell, taken at not less than 5 random places, shall not exceed the temperature limitation of paragraph furnace structure.
Preheat the incinerator for 4 hours to reach the firing temperature of 982degrees C [1800] degrees F. Weigh and record the complete charge weight. Charge the incinerator at the rated burning capacity in kg pounds per hour for a period of [4] hours and operate in compliance with the manufacturer’s written instructions. Include in operation testing the performance of the mechanical charging facilities, the incinerator, the air pollution control equipment, the ash
– capacity: 300-400 kg/hour
The pharmaceuticals squander like Alu, PVC,PVDC etc.Installation for burning of animal waste cost, existence, repayment terms where it is possible to buy in Russia? I am looking to for capacity between 200 -400kg
– Fuel syetem: Dual fuel( both gas and oil )
•Control
Test the incinerator under actual firing conditions. Verify with testing that all controls function within the maximum and minimum limits for temperature or timing. Simulate actual unsafe conditions such as high temperatures and flame failure by reducing the settings for the activation of limit and safety controls.
•Shell Temperature
Operate the incinerator under normal load conditions for not less than 6 hours. After 6 hours, temperature readings of the outer shell, taken at not less than 5 random locations, shall not exceed the temperature limitation of paragraph furnace construction.
– capacity: 300-400 kg/hour
– Fuel syetem: Dual fuel( both oil and gas)
Containerized Mobile Type Medium Unit Waste Incinerator
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).
Items/Model
TS50(PLC)
Picture
![]()
![]()
Principle
Waste Incineration Treatment
Burn Rate
Average 50-100 kg/hour
Feed Capacity
Average 200-300 kg/feeding
Control Mode
PLC(Programmable Logic Controller Incinerator)
Optional Upgrade Containerized Mobile Sort Incinerator
ISO 20′ Full Container
Combustion Chamber
560L
Internal Dimensions
1000x800x700mm
Secondary Chamber
280L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
210/240V 50Hz 1P
Power
1.3Kw
Oil Consumption (kg/hour)
Average 20.4(D.O)
Thermal capacity(kw/hour)
166-332
Gas Consumption (m3/hour)
***
Temperature Monitor
Digital Screen
Oil Tank
1000L
Feed Door
60x50cm
Chimney
10Meter
Chimney Type
Stainless Steel
1st.
800℃–-1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
7500kg
External Dimensions
Double Chamber Incinerator on sale 50-200kgs per hour(in stock)
|
|
Main Product List per 01 Collection |
|
Main Combustion Chamber |
|
|
Secondary Combustion Chamber |
|
|
Smoke Filter Chamber |
|
|
Incinerator PLC Control Case Chimney:10.0Meters |
|
|
*(upgrade to Stainless Steel, free cost) |
|
|
Italy oil/gas burner: 02 units |
![]()
Oil Tank (if Petroleum fuel): 300Liters
Items/Model
TS150(PLC)
Principle
Waste Incineration Treatment
Burn Rate
Average 50/100/150/200 kg/hour
Feed Capacity
Average 750kg/feeding
Control Mode
PLC(Programmable Logic Controller Incinerator)
Combustion Chamber
1570L
Internal Dimensions
150x100x105cm
Secondary Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
210/230V 50/60Hz
Power
0.9Kw
Oil Consumption (kg/hour)
Typical 20.4(D.O)
Thermal capacity(kw/hour)
166-332
Gas Consumption (m3/hour)
***
Temperature Monitor
Digital Screen
Temperature Protection
Yes
Oil Tank
300L
Feed Door
80x60cm
Chimney
10Meter
Chimney Type
Stainless Steel
1st.
800℃–-1000℃
2nd. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
External Dimensions
BIOHAZARD DISPOSAL INCINERATOR CONTAINERISED IN A 20 FT CONTAINER
TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE FUEL CONSUMPTION 13 KG PER HOUR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMP. MONITORING, AVERAGE ASH RESIDUE: 3%, THERMOSTATIC DEVICE: YES,
2. 50 kg/hr
TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE FUEL CONSUMPTION 13 KG PER HOUR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMP. MONITORING , AVERAGE ASH RESIDUE: 3%, THERMOSTATIC DEVICE: YES,
DIMENSIONS: EXTERNAL LENGTH (mm): 1520MM, EXTERNAL WIDTH (mm): 920MM, EXTERNAL HEIGHT (mm): 4020 MM
1. Incinerator for Bio-Medical Waste incineration needed
2. 50 kg/hr
3. 2 chambers must be there
4. temperature of primary chamber should be 850 degrees Celsius
temperature of secondary chamber should be 1200 degrees Celsius
How you can discover reasonable incinerators for your neighborhood site?
Hiclover provide medical waste incinerators with capacity 10kgs per hour to 500kgs per hour.
The incinerator with dual/double combustion chamber and dry filter room, two fuel burner from
Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour
and 50kgs per hour.
We are famous small scale incinerator manufacturer and brand, dispatch incinerator productsand best services with lower price for customer all around the world.How you can discover reasonable incinerator for your neighborhood site?
Incinerator isn’t a cheap equipment, generally the small scale version’s cost around $5,000usd per unit
and large scale version’s cost more than $50,000usd per unit. So, before purchase one unit incinerator,
you need to make clear following things:
A, burn what? Incinerator is a incineration equipment, function is flame waste. So what sort of
waste you want to treatment?
B, large or small? This according to the waste output daily or the waste volume per
feed time, like animal size.
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke
cleaner than oil fuel model. But some local site do not have gas distribution system.
Along with other technology items, like electricity (220v, 380v), waste feed door kind, incinerator structure, etc..
Nanjing Clover Medical Technology Co.,Ltd.Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]![]()
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
an animal cremator
2
Oil Tank Capacity
200~~ 300 Litre
11
Dual Combustion Chamber with Built in Smoke Filter ( Dry Scrubber )
6
Non Corrosive / Corrosion Resistant Preferably Stainless for longer Life (Height 5-7 Meter)
7
Fire Brick, Refractoy Brick, Concrete
10
Feed Mode
Fuel
an animal cremator for our company in malaysia.currently we are doing individual private cremation and mass cremation for pets in addition to medical waste.an incinerator that’s capable of burning between 3 to 5 tonnes per day of mixed waste products, plastics, rubber, flammable putrescible waste, medical waste, rubber tyres, paper and cardboard, fabrics, green timber waste etc.. As some of the waste products will include non-flammable solids, the incinerator should be capable of extracting those substances probably via a rotary kiln procedure.
It is not intended to use any fuel, such as oil or diesel, to promote the burning of the waste, since the waste products are required to be incinerated using a free burning procedure. Hot air however from a downstream process will be available to raise the incinerator temperature and burning rate as required. Very high temperatures in the incinerator are not necessary and are not required.
The burning of these waste products is expected to produce toxic emissions which will be cleaned via other existing downstream procedures and a Post Combustion procedure from the incinerator is therefore not required.
The incinerator should be capable of accommodating an automatic waste feed process.Incinerator Specification
S. No.
Standard PLC Control Panel
9
Burning Chamber
Burning Capacity
Feeding Capacity
Control Panel
7
Burners
High Quality European CE Certified Oil Burner
8
Control Panel
Standard PLC Control Panel
9
Power Supply
220/380 Volt Ac 50 Hz.
10
Oil Tank Capacity
200~~ 300 Litre
11
Burning Chamber
Fire Brick, Refractoy Brick, Concrete
Waste incinerators spare parts
HICLOVER offers spare parts Such as:
— Burners (diesel oil, LPG or natural gas)
— Element for burners
— Fire ropes
— Incinerator chamber maintenance Stuff
— Air Fan
ISO 20′ Full Container