Tag: waste-incinerator

incinerator for medical waste

incinerator for medical waste.Controlled air medical waste incinerator intended for incineration of bio-medical waste generated in a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, fabrics, papers, packs, etc.). a  diesel  fired  medical  waste  incinerator  with  a  capacity  of  300Kg/hr.  To  be  set up in a  waste  disposal  site  away  from  populated  areas.

Standards
4) Protections against over-voltage and over-current line conditions.
Require Quantity – 1 complete Unit / Set
2) Respecting international emission standards

Medical Waste Incinerator Capacity Average 100kgs per hour

Temperature Display & PLC Control Case

Main Combustion Chamber

Incinerator Main Body

***Primary Combustion Chamber

Italy Oil/Gas Burner

***Chimney:10.0Meters

***Secondary Combustion Chamber***Smoke Filter Chamber

***Italy oil/gas burner: 02 units
***Oil Tank (if oil fuel): 200Liters

***Incinerator PLC Control Case


Items/Model

TS100(PLC)

Principle

Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Feed Capacity

Average 200kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Consumption (kg/hour)

14–28

Gas Consumption (m3/hour)

10–32.2

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

HICLOVER – Medical Environmental 

260x150x180cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Containerized Mobile Incinerator Model CA50

Waste Incinerator

(Containerized Mobile Incinerator)


Capacity: Typical 50 kgs per hour

Model

CA50

Internal Dimensions

100 x 80 x 70 cm

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters

*(upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 02 units

Oil Tank (if Petroleum fuel): 200Liters

ISO 20′ Container(Delivery with Incinerator)














Model

CA50

Waste Treatment

Waste Incineration Treatment

Feed Capacity

Typical 100 kgs per feed

Burning Rate

Average 50 kgs per hour

Burning Time per Feed

Average 2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

0.7Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Screen

Fuel consumption (Oil)

Typical 16.6 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Article Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick,Refractory Concrete

Max.

166,000Kcal/Hr.

























HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Model TS30 oil fired waste Little incinerator 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr.

Items/Model

TS30(PLC)

Picture

 

Burn Rate

Typical 20-30 kg/hour

Feed Capacity

Typical 60kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Typical 13.3

Gas Consumption (N.G, m3n/Hour)

Typical 16

Gas Consumption (L.P.G, m3n/Hour)

Typical 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

100L or More(Optional)

Feed Door

55x50cm

Chimney

5Meter or More(Optional)

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4000kg

External Dimensions

HICLOVER – Medical Environmental 

175x120x140cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medical waste incineration system

Medical waste incineration system of 300 kg/hr burn rate with dual fuel (Gasoline and diesel) type, daily 8-16 hrs operation and a stack height of 15 meter.Primary combustion

20.     Fan:
•    Post combustion: 1100oC.
The residence time in the secondary chamber shall not be less than two seconds;
Nature: 65% of Al203
14.    
.
15.     Fuel : diesel
* Carcass in strong sheet steel with assistance of link.
23. Capacity to treat Plastic: Not less than 40% by weight
8.     It should be able to hold emission in the next burn with gasoline residence of not less than two seconds.
The gas temperature as measured against the inside wall in the secondary chamber, not in the flame zone, will not be less than as indicated in Lots 1-7;
Control box watertight to dust, including:

* A switch circuit breaker for each engine (ventilators and burners).
* Burner with fuel, mono-bloc casting guiding type with flat flame, lighting and safety of     electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
This incinerator with”PYROLYTIC” combustion must have:
* A device of injection of air allowing a Whole recombustion of gases,
Nature: Calcium
22. Process Filtering system: Scruber to be mentionned as discretionary
* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

18.     A chamber of post combustion of gases
•    The Temperatures of combustion: Minimum will be 850oC and maximum 1400oC
21.     Controls and regulations:
2.    
* Composition of the refractory;
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
6.     The incinerator must prevent the discharge of black smoke and dust that is fine, (Smokeless) during the loadings.
13.    
5.     “PYROLYTIC” combustion, by controlling the gasification of waste.
22.     The provider must give batches of spare parts of first urgency and consumable of the incinerator.
•    Nature: Calcium silicate.
The minimum exit velocity of the emissions will not be less than 10 metres/second;1.     Capacity of destruction in weight: 60 Kg/h.
3.     This incinerator has to have the ability to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
* A sheath of evacuation of the gases burnt.
12.     The Amount of the combustion chamber: 1.200 L
16.     The provider must provide  necessary information for the best of  the installation
23.     The installed incinerator must bear a 1 year guarantee.
Both the primary and the secondary temperatures shall be maintained until all the waste has been completely combusted;

Chimney
7.     It should be able to reduce the quantity of wastes by 98%.
* A regulator with electronic viewing for the temperature of combustion.
23. Emission Standards Compliance: BS 3316 or équivalent standard
The chimney will have a minimum height of 4 meters above ground level;
9.     The incineration should be completely free from visible smoke in addition to offensive odours.
* A timer with adjustable temporization for the regulation of each burner.
10.     The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg

24. CE Manufacturing Compliance: BS EN 746-2-1997
. Nature: 42 percent of Al203
* Electric box.

21. The de- ashing has to be completed in the bottom of the combustion chamber or the deashing should be Automatic or manual batch p ashing.
. Thickness: ≥75 mm
* A regulator with electronic viewing for the temperature of postcombustion.
* Burner of light of waste, with gas, regular mono-bloc casting directing stirring flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
4.    
17.     A combustion chamber of waste:
From the mill; it will consist of curative and preventative maintenance, and the use of machine, etc

Hiclover waste incinerator

Key Features:

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, 

General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, 

High Efficient Environmental Waste Incinerator.

— Single combustion chamber, double combustion chambers, three combustion chambers and 

multi-combustion chambers waste incinerators.

— System solutions for medical waste environmental.

— High burn rate, from 5kgs to 1000kgs per hour.

— New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental 

protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We supply single combustion chamber, double combustion chambers, three combustion chambers and 

multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene 

clinical waste destruction with medical disposable, biological waste, medical plastic waste, toxic waste, 

red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc..

      

Our assortment of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, 

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber 

again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, 

high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste 

package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet 

cremation business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no 

incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, 

Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner 

for governmental organizations, non-profit organizations, international contractors, logistics organizations, 

military, pet cremation business owners, etc. We have export experience more than 40 countries, including 

war zone like Iraq, Afghanistan, Somalia, South Sudan.

cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for 

incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, 

pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, little

animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer 

reduce purchase budget, custom made function, quality products and friendly service.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Various Types of Incinerators

Volume 6 — Mobile Incinerator
10m Hose Pipe, indicate length
One year Spare Parts Package for complete maintainability
Burn Rate 100kg/h minimum
General
Warranty, indicate no of years

Volume 4 — High Temperature Waste Incinerator
Minimum working temperature 850 °C, please indicate
Gas Retention Time – 2 Seconds
I000 Litre Fuel Tank + Pipe System, indicate volume
Burn Rate 100kg/h minimum
Burn Rate – 150kg/hour minimum
1000 Litre Fuel Tank + Pipe System, indicate volume
Chimney
Fuel – Diesel/LPG/LNG, please indicate
Minimum working temperature 1200°C, please indicate
Warranty, indicate no of years

Incinerator model C
Additional chimney expansion, indicate height
Minimum working temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
Minimum working temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
Minimum exit velocity of the emissions less than 10 metres/second
One year Spare Parts Package for complete maintainability
1000 Litre Fuel Tank + Pipe System, indicate volume
Burn Rate 250kg/h minimum
Secondary Chamber
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Weight (kg) please indicate:
One year Spare Parts Package for complete maintainability
One year Spare Parts Package for complete maintainability
Secondary Chamber
Warranty, indicate no of years

Volume 7 — High Temperature Waste Mobile Incinerator
Weight (kg), please indicate:
Burn Rate 50kg/h minimum
Mobile Incinerator model F

hazardous waste high temperature incinerators for treating hazardous wastes. The waste will be mixed, including medical, oily wastes, forests and laboratory wastes. Primary combustion
Diesel/LPG/LNG burning main combustion chamber/primary combustion zone
Weight (kg), please indicate:
Secondary Chamber
Additional chimney expansion, indicate height
Weight (kg), please indicate:
10m Hose Pipe, indicate length
Fuel – Diesel/LPG/LNG, please indicate
1000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney expansion, indicate height
Gas Retention Time 2 Seconds
Secondary Chamber
Secondary Chamber
Power Supply for Control Box – 220V-240V 50Hz single phase
Power Supply for Control Box 220V-240V, single phase 50-60Hz
Warranty, indicate no of years

Volume 5 — Mobile Incinerator
Diesel/LPG/LNG, please indicate
Gas Retention Time – 2 Seconds
10m Hose Pipe, indicate length
Burn Rate 65kg/h minimum
Weight (kg), please indicate:
Both main and the secondary temperatures maintained until all the waste was completely combusted
Minimum working temperature 1200 °C, please indicate
Secondary combustion
Additional chimney expansion, indicate height
Weight (kg), please indicate:
Control box that can be detached and mounted on different stand at least 1.5 meters from incinerator at approximately 1.6 meter height

Incinerator model A
Mobile Incinerator model E
Fuel – Diesel/LPG/LNG, please indicate
Secondary Chamber
Weight (kg), please indicate:
Minimum working temperature 850 °C, please indicate
Temperature Warnings
Gas Retention Time 2 Seconds
Additional chimney expansion, indicate height
One year Spare Parts Package for complete maintainability
Additional chimney expansion, indicate height
Residence time in the secondary room less than 2 seconds
Power Supply for Control Box – 220V-240V 50Hz single phase
HTW Incinerator model D
Minimum working temperature 920 °C, please indicate
10m Hose Pipe, indicate length
Additional chimney expansion, indicate height

Incinerator model B
Gas Retention Time – 2 Seconds

Incinerator for Animal Crematory Pig Farm Model A1200

Incinerator for Animal Crematory Pig Farm Model A1200

*** 3 sets Burners
*** Good for animals or big pets
*** Double Combustion chamber
*** stainless steel chimney
*** Italy made oil burners
*** 1200Liters(1.2m3) big chamber

Model

A1200

Picture

Burning Rate

Typical 50 kgs/hour

Feed Capacity

Average 100 kgs/feeding

Main Combustion Chamber

1200 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V/380V

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 34.4 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

130x100x90cm (primary chamber)

External Dimensions

220x180x360cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

55 x 80cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7500 kgs

Operation Technical Specifications

Main Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power

3000Kcal

Model

A1200

Internal Dimensions

130x100x90 cm

Suit for Animal

Cat – yes

Dog – yes

Pig – little

Cow – no

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber(Dry Scrubber)

Incinerator Control Case

Chimney:10.0Meters *(update to Stainless Steel, free price )

Italy oil burner: 03 sets

HICLOVER – Medical Environmental 

Oil Tank: 500Liters


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.