Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business

Design for Pets Cremation Business

Movable platform & Auto. Door

Independent Position for Small Pet

Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business

Model

A1500

Picture

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 350 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 53.0 kg/hour

Gas Consumption (Natural Gas)

Average 63.6 m3n/hour

Internal Dimensions

150 x 100 x 100cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

8000 kgs


HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-26

Smallest Incinerator 30kgs

Average 30kgs per hour

***Primary chamber(200Liters)

*** Secondary chamber

*** Mix combustion chamber

*** Stainless steel chimney(1meter)

*** Italy made oil burner(2sets)

*** Dry Scrubber

*** Weight 1.7T(can reduce to 1.0Ton)

Main Spare Parts(Standard for incinerator, and price include already):

*** 2 sets Italy Oil Burner

*** 2sets Temperature Probe

*** 1 set Control Case

*** 1 set Air Fan

*** 1 set Diesel Oil Tank

*** 1 set Maintain Material



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-24

incinerator manufacturers

1. SCOPE OF WORK The work specified in the contract will include.
1. Supply, install and commission an incinerator as provided in the technical specifications
2. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during execution of the works covered in this tender.
3. Assessment and preparation and construction of a standard incinerator shed with one waste storage room ( see the design )

4. Provision of operation and maintenance manuals and drawings complete with maintenance schedule and instructions.

5. Fuel oil storage tank- Mild steel1500 liters capacity

6. Onsite training for operation and maintenance staff.

IMPORTANT
incinerator manufacturers To enable the Employer undertake conclusive evaluation of the tender, tenderers are requested to submit with their offers the detailed specifications, drawings and catalogues with commissioning and maintenance instructions for the Incinerator they intend to supply, install and commission. Tenderers who fail to comply with this requirement fully shall have their tenders rejected. 2. TECHNICAL SPECIFICATIONS OF THE REQUIRED INCINERATOR

2.1 General Description

The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to:
1. Overall plant layout
2. Feed chamber/charging
3. Primary combustion chamber
4. Particulate scrubbers
5. Acid gas scrubbers.
6. The stack/chimney.
7. Minimum capacity of primary chamber = 0.18 cubic metres
8. Burn rate (rate of waste incineration) = a least 20 kg per hour
9. Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash.
Supply, Installation and Commissioning of An Incinerator in Eastern Hydros [ Page 28

2.2 Feeding and Charging
Controlled hygienic mechanical feeding that does not negatively influence the air temperature in the primary and secondary chambers of the incinerator shall be used.
2.3 Primary Combustion Chamber.

a) This chamber should be equipped with burners that use low sulphur fuel.
b) The chamber should ensure a minimum exit temperature of 850 degrees centigrade.

2.4 Secondary Combustion Chamber (After burner)

a) Should be fitted with burners that use low sulphur fuel.
b) Ensure secondary air supply is controlled.
c) Ensure residence time is not less than two seconds.
d) Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is not less than 1100 degrees centigrade.
e) Ensure the emitted oxygen content of the emitted gases is not less than 11%
f) Ensure both primary and secondary combustion temperatures are maintained until all waste is completely combusted.

2.5 Particulate Removers

A mechanical particulate collector must be incorporated after secondary combustion chamber for removal of particulate pollutants entrained in the flue gas stream. The particulate collectors may include any of the following or a combination thereof:
a) Cyclone separator
b) Electrostatic precipitators
c) Fabric filters
2.6 Chimney/Stack

l) The chimney should have a minimum height of 10 metres above ground level and clear the highest point of the building by not less than 3 metres for all roofs. The topography and height of adjacent buildings within 50 metres radius should be taken into account.
m) The chimney should be visible to the operator from the feeding area.
n) The minimum exit velocity should be 10 metres per second and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting gases.
o) The point for measurement of emissions shall be provided.

2.7 Instrumentation

a) Instrument for determining the inside wall temperature and not burner flame temperature must be provided for both primary and secondary chambers.
b) An audible and visible alarm must be installed to warn the operator when the secondary chamber temperature drops to below the required temperature.
c) A carbon monoxide and oxygen meter/recorder should be provided

d) A smoke density meter/recorder should be provided.
e) A solid particulate meter/recorder should be provided.
f) Any other instrument that may be considered necessary.

2.9 Emission Limits

a) Combustion efficiency (C.E) shall be at least 99.00% where C.E = %Carbon dioxide x 100 / [% Carbon dioxide + carbon monoxide]
b) The temperature of the primary chamber shall be 800 +/- 50 degrees centigrade
c) The secondary chamber gas residence time shall be at least 1 second at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack gas.
d) Opacity of the smoke must not exceed 20% viewed from 50 metres with naked eyes.
e) All the emission to the air other than steam or water vapour must be odourless and free of mist, fume and droplets.
f) A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where DRE [ ( Win – Wout) /Win ] x 100 where Win = mass feed rate of the POHC in the waste stream fed to incinerator and Wout = mass emission rate of POHC in the stack prior to the release to the atmosphere.
g) The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16 hours.

– Manual technical monitoring is shipped with the hardware with all explanations of failures and resolutions
Capacity/island : 4000 kg/day ; 25000 kg/day ; 31000 kg/day ; 48000 kg/day

Burning temperature – over 12000C

Two chambers – minimum

Emissions – dioxin and heavy metaly – better then Kyoto protocol

Emission – monitoring system

Waste unloiding – directly from waste track to incinerator

Melt blown Production Line 400mm and 1600mm and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. N95 and Disposable Mask Machine

 

2. 400mm and 1600mm Melt blown Production Line

3. ES Fiber Production Line

 

 

 

N95 Face Mask Machine Production Line

Melt blown Production Line

 

A.)Optional Capacity: 1600mm

Efficiency: 95-97%

FOB Term Price: USD per set

Price Valid: 5days.

Ave.60 Days ready for shipping.

In stock Price: USD per set

 

 

B.)Optional Capacity: 400mm

Efficiency: 40-50% .

FOB Term Price: USD per set

Price Valid: 5days.

Ave.20 Days ready for shipping.

Payment: TT 70% In advance, TT 30% before leave factory

Shipping: 1*20′ container per set, Ave. 2000Kgs.

 

Main Parts: Extruder, mold, winder, oven, ultrasonic

Daily Capacity100-150Kgs/24Hours

Screw extruder100-150Kgs

Motor power: 15KW frequency conversion speed regulation
Reducer speed ratio: 1:10 or 1:16
Screw length to diameter ratio: 30: 1
Screw diameter: 50mm
Winding machine diameter:
630mm
Winding machine drive motor power: 0.55kw
Speed ratio of winder drive reducer (if any): 1:71
Air heater power: 15kw
Power of vacuum calciner: 12kw
The size of vacuum calciner: 500 × 300 × 200
Ultrasonic power: 1800, frequency 28kHZ
Ultrasonic sink size: 800 × 300 × 250

 

 



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-20

medical incinerator manufacturer

1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan accounting for the air supplied through burners. Provision shall be made in the primary chamber to measure the water column pressure.
2. Capacity : up to 4000kg      burn not less than 500 kg /hr
3. medical incinerator manufacturer The refractory lining of the chamber shall be strong enough to sustain minimum temperature of 1000dc in the primary chamber and 1200 dc in the secondary chamber. The refractory& insulation bricks shall have minimum 115mm thickness each & conform to IS:8-1983 & IS:2042-1972 respectively.
4. The incinerator shell shall be made of SS/MS plate of adequate thickness (minimum 5mm) and painted externally with heat resistant aluminium paint suitable to withstand temp.of 250 dc with proper surface preparation. Refractory lining of the hot duct shall be done with refractory castable (minimum 45mm thick)& insulation castable(minimum 80mm thick). Ceramic wool shall be used at hot duct flanges & expansion joints.
5.There shall be a separate burner each for the primary & secondary chamber. The heat input capacity of each burner shall be sufficient to raise the temp.in the primary & secondary chambers as 800+/- 50dc and 1050+/-50dc respectively within maximum of 60 minutes prior to waste charging. The burners shall have automatic switching off/on control to avoid the fluctuations of temperatures beyond the required temp.range.
6.Incinerator shall have graphic or computer recording device which shall automatically and continuously monitor and record dates, time of day, batch sequential number,Co,Co2,O2 in gaseous emission shall also be  measured daily.
7. Structural design of the chimney/stack shall be as per IS:6533-1989.The chimney/stack shall be lined from inside with minimum of 3mm thick natural hard rubber suitable for the duty conditions and shall also conform to IS:4682 part I-1968 to avoid corrosion to oxygen and acids in the flue gas.

8.The incinerator must have an emergency vent. The emergency vent shall remain closed ie. it shall not emit flue gaseous during normal operation of the incinerator.

9.Metal fuel tank from black steel (capacity not less than 2500 litres) and shall be installed at the incinerator Room. The tank shall be provided with all necessary fittings including fill, vent, drain and overflow line, level indication and access for inspection and maintenance. Level switches shall be provided for the following services.

(a) Low level alarm
(b) High level alarm
(c) Low level start of transfer pump
(d) High level stop of transfer pump

10.A ready built fabricated room shall be supplied for housing the incinerator. The room will be designed in such a way that free space is  available  on all sides and heat radiation  kept at minimum and giving the operators an easy workable environment and ventilation. The materials will be sufficient structural thickness of mild steel angles neatly coated with metal primer and epoxy paint to withstand sea corrosion
– effectiveness for the treatment of placenta? and expired or spoiled drugs, cytotoxic and cytostatic drugs prescribed: narcotics eg
– Does it allow to treat drug or waste containing glass (whatever color: transparent or colored white) without causing explosions?
– The ability of the liquid waste treatment (blood, urine stained, other body fluids contaminated, regardless what volume packaging?
– The efficiency of process chemicals (after neutralization and detoxification: solids and liquids)
– Is there  microbiological testing especially: the processing efficiency bascillus

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set

Dimension(L*W*H): 1037*855*1780

Power Supply 15.3kw mono phase

Net Weight: approx.: 1500kg

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-10

laboratory incinerator

the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a special truck

air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).

Incinerators should be provided in the fuel tank (diesel )
? The minimum capacity of the animal carcass incinerator
The destruction of 1000 kg / hour. Incinerator capacity is calculated
8MJ/kg- material and 60 % humidity.
? It must be possible to use the incinerator +40
C to – 15 0C laboratory incinerator
Temperature and 5% – 95% – of moisture conditions.
? PLC controller and a built-in temperature panelita complete
Automatic control, a control computer, which is stored
Information on the variation of temperature with respect to time and
Graphic images.
? must have fuel with automatic control and malfunction
Detection system.
?the ability to pre- warm-up , body waste burning on and off
Consistency is independent of the first and secondary chambers.
? ensuring the incinerator with electricity , it
Must be installed on the generator.
? clean the incinerator should be simple tools ,
Without using any additional equipment

Medical Incinerator Manufacturers in Stock ready for shipping

Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-10

medical incinerators

● Able to burn 25-30kg per hour
● Consist of two chambers to ensure significant reduction in emission
● Be capable of temperature in range of 800c to 1000c
● Low maintenance design
● Must be Diesel fuelled
● Need more than 15amp 220- 250V power
● kW Consumption power consumption to be stated
● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste
● Solid waste reduction in range of 90-97% ( should be routinely achieved)
·         General wastes produced on a daily basis  include paper, plastic, organic materials, boxes, plastic containers, leaves, etc;

·         Total waste produced per day: 10-12 tonnes;

·         Hours of Operation: 10 hours a day;

·         Fuel requirement: Diesel or waste oil preferred but LP gas will be considered;
Fuel options    Oil
Fuel consumption (diesel)    10 litre/hour
Average Capacity    900kg
Diamention: Length (mm)
Width (mm)
Height Excl. Flue (mm)
Door Opening (mm)    2570
1120
1340
1000×1670
Internal Chamber Dimen:
Length (mm)
Width (mm)
Height Incl Flue (mm)
2200
790
790
Operation:
Min. Operation Temprature
Max. Operation Temprature
Residence Time in Second Chamber
Temprature Monitoring
950
1320

2 sec.
YES
Key Features
-Auto ignition
-Automatic control and temprature
-Upto 250 kg per hour
-Thick refratory lining rated to 1600 deg C in main chamber retain heat, increase efficiency
-Heat resistant 5 mm steel
-Stainless steel stack
-12 cm of refractory lining- steel reinforced.
-12 month or 1000 hours waranty
-Heat recovery system
-Wide door for ash removal
-Large top opening lid for easy loading

Medical Waste ncinerators for Hospital 10-500kgs per hour

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm


Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 5300 kgs 7000 kgs
Picture

Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 300
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chmaber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
HICLOVER – Medical Environmental 
Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Picture

Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chmaber Temperature 1000-1200 1000-1200 1000-1200 1000-1200


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator