hiclover

INCINERATOR DIESEL DRIVEN

INCINERATOR, DIESEL DRIVEN
waste kind: HEALTHCARE WASTE
Waste calorific worth: 4000KCAL/KG
Wetness Content: 10-25%.
Nominal Capability: 50Kg/Hour set load.
Second Chamber: 2 Secs @ 850degrees C.
The main combustion chamber must ensure minimal leave temperature level is not less than 850 levels C.

INSULATION.
Calcium Silicate.
Restricting Continual service limit 1000 degrees C.
Density 25mm

THROUGHPUT.
50kg/hour at a small calorific worth of 4,000 kcal/kg and also an ordinary mass thickness of 120kg/MCubed for basic waste and 160kg/MCubed for health care waste.

Incinerator Equipment



Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:Nanjing Clover

Product Description

TS model PLC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like medical waste manufacturer, medical waste pyrolys, medical waste sterilization "300kg", medical waste suppliers china, medical waste treatment china, hospital, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

китайский медицинский мусоросжигательный завод

следующие мусоросжигательные заводы в контейнерах. (Кухня и жилые помещения, а также завод по удалению бытовых и черных водоемов) нам нужен мусоросжигательный завод, каждая функция отдельная, все в одном мусоросжигательном заводе, который нам необходимо проинформировать. Завод, который мы устанавливаем для нашей жилой баржи, используемой в проекте морского строительства. 200 человек будут размещены на борту.
РЕКОМЕНДАЦИИ ПО ИНСИНЕРАТОРАМ

китайская медицинская установка для сжигания отходов
? Сжигайте минимум 80 кг / час X 12 часов в день
? Удаление потоков как неопасных, так и опасных отходов (в соответствии с перечнем отходов)
? Мобильный блок (предпочтение устанавливается на салазках с точками подъема)
Дизайн / Технические характеристики
Мусоросжигательные заводы должны иметь вторичную камеру сгорания с минимальным диапазоном температур 900 ° C
? Потоки жидких отходов должны сжигаться с помощью соответствующей системы впрыска жидкости.
• Мусоросжигательные печи будут оснащены визуальной сигнализацией для предупреждения операций о низкой температуре во вторичной камере.
Рабочая среда и окружающие условия

Блок инсинераторов должен быть спроектирован для работы в следующих условиях:
? Среднесуточная максимальная / минимальная температура июня, 21-39 ° C
• Среднесуточная максимальная / минимальная температура января, 2–12 ° C.
Установка для сжигания медицинских отходов,
ок. 0,4 кубометра,
дизельное топливо / питание от сети,
термостатический контроль температуры,
программируемый цикл

Especificaciones requeridas para incinerador móvil

Capacidades operativas

 

  • PROCESO MÍNIMO 1 TONELADA POR DÍA
  • OPERADO CON CAPACITACIÓN LIMITADA
  • EL MANTENIMIENTO REGULAR SE PUEDE COMPLETAR CON CAPACITACIÓN LIMITADA
  • CUMPLE CON LAS NORMAS DE EMISIÓN EURO / US-EPA
  • CAPACIDAD PARA QUEMAR LUBRICANTES RESIDUALES (POL)
  • MANIPULAR SÓLIDOS ORGÁNICOS (INCLUYE RMW)
  • DESPLEGABLE
  • MÓVIL
  • 24 HORAS DE USO CONTINUO
  • SISTEMA DE CARGA AUTOMÁTICA
  • SISTEMA AUTOMATIZADO DE EXTRACCIÓN DE CENIZAS
  • SISTEMA DE FREGADO A GAS
  • REDUCCIÓN DEL 95% DE RESIDUOS SÓLIDOS
  • OPERAR SIN DIESEL O ACEITE COMBUSTIBLE
  • CAPAZ DE QUEMAR 4 UNIDADES DE RESIDUOS POR UNIDAD DE COMBUSTIBLE
  • CAPAZ DE LLEVAR TODOS LOS RESIDUOS COMBUSTIBLES QUE INCLUYEN: PAPEL, PLÁSTICO, CARTÓN, ALIMENTOS, ACEITES USADOS, LODOS, TRAPOS ACEITOSOS, MADERA
  • NO SE REQUIERE TRATAMIENTO PREVIO DE RESIDUOS
  • GARANTÍA DE COMPONENTES DE CINCO (5) AÑOS

Especificaciones técnicas

 

  • MANUAL DE FUNCIONAMIENTO Y MANUAL DE ENTRENAMIENTO PARA CADA INCINERADOR
  • MANUALES DE INSTRUCCIONES DE CONFIGURACIÓN E INSTALACIÓN
  • IMPRESIÓN EN AZUL / ESQUEMÁTICA PROPORCIONADA QUE DESCRIBE LAS DIMENSIONES FÍSICAS DE LOS INCINERADORES DE 20 ‘
  • INCINERADORES COMPUESTOS CON CONSTRUCCIÓN SOLDADA PARA TRABAJOS PESADOS
  • OPERADO Y TRANSPORTADO EN INCINERADORES DE 20 ‘(CONTENEDORES)
  • ACCESO COMPLETO DELANTERO Y TRASERO OPCIONAL
  • CONTROLES DE TEMPERATURA PRIMARIO / SECUNDARIO

Concerning Medical Waste

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses.

Standard 20% -25% of the complete waste generated by medical care facilities is related to as hazardous and may create a selection of health as well as environmental dangers if not handled and damaged in an proper way. With years worth of experience in this sector, our clinical array of burners are made to provide for the economical needs of tiny facilities to the more demanding and also specialized requirements of big medical facilities in their waste monitoring processes.
HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.

Our products make sure reliable, tidy as well as easy disposal of medical waste is possible. The incineration of clinical waste including pathological waste ( red bag waste), Biohazards & & Sharps, General Medical Waste, from Hospitals, Study Center, Drug Companies , Drug Produces, Main Treatment Trusts, Aesthetic Surgical Procedure Centers, Nursing Residences, Care Homes and other Medical Waste.

○ Middle-Small Capability( TS Model) ※ Key Qualities:— — Dual Burning Chamber— — Double Italy Heater–– Burning Rate: 10-100kgs per hour–– Burning Chamber: 0.1M3-1.2 M3 ※ Optional Function/Parts/Material/ Burning Price: — — Stainless Steel Chimney — — Dry Smoke Filter Chamber— — Chimney Elevation Customized Made— — Upgrade/Downgrade Burning Rate


○Large-Middle Capacity(YD Model)
※Main Feature:
–Three Combustion Chambers
— Double Italy Burner
–Burning Rate: 30-600kgs per hour
–Combustion Chamber: 0.36M3-5.5M3
※Optional Function/Parts/Material/Burning Rate: 
— Stainless Steel Chimney 
— Dry Smoke Filter Chamber
— Chimney Height Custom Made
— Semi-Automatic Waste Feeding
— 3-Section Wet Scrubber System
— Movable Platform Feeding Door
— Additional Burner
— Upgrade/Downgrade Burning Rate

● Service before and also after Setup — — Manufacturing facility training for installment, operational and also upkeep with totally free expense.— — Online solution support for installment, operational as well as maintenance with complimentary cost.— — Onsite installation , operational and maintenance training — Onsite solution assistance after setup

● Spare components supportHICLOVER currently uses extra parts including: — Burners( diesel oil, LPG or gas) — Element for burners — Fire ropes — Burner chamber upkeep materials — Air Fan — Temperature level aspect — Smoke filter block — Control box — Other components

Nanjing Clover Medical Technology Co., Ltd.

Tel: +86 -25 -8461 0201 Fax: +86 -25 -8461 0406

Web site : www.hiclover.com Email— : [email   safeguarded] Email: [email   protected]

производитель мусоросжигательного завода Китай

производитель мусоросжигателей Китай, Камера для отходов
Вместимость камеры 300 кг
Объем камеры .54м3
Размер камеры (снаружи) Ширина: 91 см, высота: 86 см, длина: 152 см
Дверной проем 66 х 76 см
Высота до двери 84 см
Высота до верха штабеля 5,4 м
Рекомендуемый размер плиты (Д x Ш x Толщина) 1,8 м x 2,4 м x 10 см
Скорость сжигания: примерно 45 кг / час.
Куча:
2′-14 ″ ”диаметром. (36 см), 14 калибра (1,90 мм) из алюминизированной стали, футерованная огнеупором
8′-12 ″ ”диам. (30,5 см), размер 16 (1,52 дюйма)
«Горелки Дизель
Ручной таймер
Стандартное электрическое обслуживание – 115 В, 60 Гц, 20 А
Общее описание:
Первичная камера: прочный стальной корпус
Высококачественная огнеупорная футеровка и изоляция
Большая полноразмерная дверца с верхней загрузкой и удерживающая жидкость подоконник
1 x дизельные запальные горелки, работающие вкл / выкл
Дверца для удаления золы
Дымоход: Прочный корпус из нержавеющей стали
Длина 1,5 м
Стопка с огнеупорной футеровкой 0,6 м
Панель управления: Управление 1 горелкой
Таймер управления 0-12 часов
Встроенное управление таймером вентилятора
Контроль температуры
Автоматическое управление
Настройка времени цикла
Вспомогательное оборудование: руководства по эксплуатации и техническому обслуживанию
Список запчастей
Пепельные грабли
Контейнеризация: 20-футовый транспортный контейнер с установленной инсинератором
500 литровый топливный бак

Hiclover biography waste incineration

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.

※ Main Attribute:— — Double Burning Chamber— — Double Italy Burner–– Burning Price: 10-100kgs per hour–– Burning Chamber: 0.1M3-1.2 M3— — Mobile Incinerator, Standard delivery containers, Easy to move/transport system— — Free Installation, Pre-installed burner, Suitable for camps— — Ultraviolet light sterilization inside

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste
Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*:
heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of 
non-combustible fines below 20%; moisture content below 30% by weight
Combustion performance: The medica waste incinerator shall be capable of reducing waste to ash not exceeding 10% of the total combustible 
charges.
Outdoor installation. The medical waste incinerator will be installed outdoors. All incinerator components shall be suitable for but not 
limited to outdoor shaded installation, including electric motors, be resistent to corrosion, moisture and related weather elements.

Products of building and construction: The incinerator will not have any asbestos, asbestos-containing materials, mercury thermostats, as well as mercury switches. Refractory materials will be able to meet appropriate standards under ISO TC33 and also CEN/TC 187.

Kinds of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator


WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Modern Technology Co., Ltd.

Tel: +86 -25 -8461 0201 Site: www.hiclover.com Email: [e-mail   safeguarded] Email: [e-mail   secured]

incineradores de pequeña capacidad

Capacidad destructiva de 55 Kg / h jour de déchets hospitaliers avec un p? .C. i jusqu’à 3.200 Kcal / Kg

1) Tipo de déchet

hospitalario

2) Pouvoir calorifique inférieur 3.200 kcal / kg

3) Humedad 20%

4) Teneur en cendres et / ou inertes 8%

5) Capacidad destructiva nominal 55 kg / h

6) Volumen cámara de combustión 1,65 m3

7) Volumen de la cámara postcombustión 2,1 m3

8) Temps transit des fumées en postcombustion / sec. <2

9) Temperatura mínima en postcombustión 1.100 ° C

10) Teneur d’oxygène libre en postcombustión 6%

11) Rechazo de atribución confectionné en sachets HDPE

12) ¿Dispositivo de carga ?: hydraulique ?; capacidad de carga 0,5 m3

13) Gasoil prévu combustible

14) Br? Leur en chambre de combustion nbr ?: 1

15) Br? Leur en chambre de postcombusttion nbr ?: 2

CONSTITTUCIÓN DE L’APPAREIL.

1.CARGA

Système de chargement hydraulique afin de pouvoir charger le four en toute sécurité même durant son fonctionnement et

aussi assurer la puissance destructive globale de 450 kg / j?

Le système comprend ?:

1-1Trémie de chargement de forme parallélépipédique de 0,5 m3 de volume, réalisée en t? Le d’acier, bridés sur la paroi

frontale de la chambre de combustion et munie d’un couvercle à charnières actionné par vérin hydraulique ?.

¿Dimensiones?:

oLongueur 1200 mm

oHauteur 700 mm

oLargeur 600

1-2Un poussoir hydraulique assurera le chargement de la chambre de combustion

1-3 Une porte de chargement de la chambre de combustion constituée d’une guillotine à vérin hydraulique revêtue

de réfractaire

1-4Un central hydraulique pour piloter tous les vérins de commande, comprenant ?: réservoir, pompe, électrovannes et

tuyauteries

2.CHAMBRE DE COMBUSTION PRIMAIRE

2-1- Le bati est une structure métallique cylindrique revêtue intérieurement d’une couche d’isolant et d’une

couche de réfractaire.

2-2-volumen intérieur ?: 1,65 m3

2-3-Aménagement

? portillon de décharge des cendres ?: frontal ?; monté sur double charnière et revêtu de réfractaire avec hublot

d’inspection

? La connexion à la chambre de chargement est revêtue de réfractaire

? La connexion de la chambre de combustion et de la chambre de postcombustion est revêtue de réfractaire

? Installation des bruleurs

? Installation du système de distribution de l’air comburant

? Installation des sondes de mesure de la température

? Le bac de récolte des cendres est en acier au carbone sur roulettes, équipé de racloir métallique permettant

l’évacuation manuelle des cendres

  1. BRULEUR DE LA CHAMBRE DE COMBUSQTION

Un bruleur de type à une flamme à l’air soufflé, alimenté par gasoil, équipé des dispositifs de sécurité Puissance

thermique installée 165 KW.

  1. AIRE COMBURANTE

Le système de distribution et dose de l’air primaire en chambre de combustion comprend ?:

Centrifugadora Ventilateur

? Canalizaciones de distribución de aire

? Systéme de distribution d’air à 2 canaux

? Soupape de régulation de l’air motorisé selon les phase of cycle de fonctionnement et de la température

дешевые инсинераторы

ПЕРЕРАБОТКА ПЛАСТИКОВЫХ ОТХОДОВ (НЕ ПВХ) 218 693
КАРТОН 85 046
ДОКУМЕНТ 4 956
ПВХ 15 115
ОПАСНЫЕ ОТХОДЫ МЕДИЦИНСКИЕ ОТХОДЫ 1084
ТВЕРДЫЕ ОТХОДЫ, ЗАГРЯЗНЕННЫЕ УГЛЕВОДОРОДами 300 680
ФИЛЬТРЫ МОТОРНОГО МАСЛА Б / У 85,423
ЗАГРЯЗНЕННЫЕ УГЛЕВОДОРОДОМ ПОЧВЫ 88 680
ОБЫЧНЫЕ ОТХОДЫ ВОЛОКНА 14 078
ИСПОЛЬЗУЕМЫЕ ВОЗДУШНЫЕ ФИЛЬТРЫ (АВТОМОБИЛЬНЫЕ И АНАЛОГИЧНЫЕ) 23149
СРЕДСТВА ИНДИВИДУАЛЬНОЙ ЗАЩИТЫ (СИЗ), ВКЛЮЧАЯ ЗАГРЯЗНЕННУЮ ОДЕЖДУ И АНАЛОГИЧНЫЙ МУСОР 130 861
Трупы свиней / бродячих собак и более крупные туши животных дешевые мусоросжигательные печи –
Грузоподъемность в диапазоне до 300 кг / сжигание ок. 50 кг в час

Горелка с регулируемой температурой. Мусоросжигательные заводы должны быть спроектированы в соответствии с нормами контроля загрязнения. Технология: Прочный корпус, чтобы быть качественным, прочным, надежным, экономичным мусоросжигательным заводом с соответствующим управлением, простым в эксплуатации и автономным. Устройства должны быть предварительно собраны, смонтированы, смонтированы и протестированы перед транспортировкой / экспортом.

Примечание: аналогичные технологии и / или предложения участников тендера приветствуются.

В рамках консультаций по экологическому оборудованию и технологиям и совместных закупок это Закупочное / Нотариальное бюро приглашает претендентов на предварительный квалификационный отбор с целью первичного отбора способных компаний для участия в вышеуказанном тендере.
Поставка будет включать в себя специальное оборудование для эффективного управления отходами, как упомянуто выше, для новой частной компании по управлению экологическими контрактами с запланированными операциями в 2013 году в Индонезии и Таиланде и в 2015 году в Западной и Восточной Малайзии для оказания этих профессиональных услуг в соответствии с правительственные требования по безопасному удалению отходов животноводства в регионе и соблюдение более высоких технических стандартов в этой конкретной области для защиты населения и сдерживания контагиозных и инфекционных вирусов и болезней, вызываемых животными. Распространение новой болезни свиней, также «вирусной болезни Нипах», впервые проявившейся в 1998 году в Юго-Восточной Азии, которая вызывает болезни и смерть как людей, так и свиней, снова растет; а также внезапная гибель свиноматок и хряков была зафиксирована на свинофермах Малайзии и других районах Юго-Восточной Азии.

Efficient stove technology eases N. Kenya’s medical waste problem



WAMBA, Kenya, June 30 (Thomson Reuters Foundation) – Poor weather, security threats and bad roads have made disposing of the Wamba district hospital’s medical waste a challenge.

The nearest incinerator is about 200 kilometres (125 miles) away and “travelling was not possible during heavy rains because connecting roads were cut off by floods,” said Stephen Lesrumat, a medic at the hospital.

But now the north-central Kenyan hospital has a solution to its problems, and a way of cutting climate changing emissions and deforestation: A high-efficiency medical waste incinerator that uses just a fifth the fuel of a traditional incinerator.

The wood burner, which takes advantage of powerful winds in the region to drive the flames, borrows technology from fuel-efficient stoves. It can safely eliminate waste produced by the Wamba hospital and by 22 other health centres in Samburu County, said Lesrumat and Ibrahim Lokomoi, the facility’s engineer.

“It has reduced the burden of travelling outside the county to get rid of medical waste,” Lesrumat said, sparing hospitals a potentially dangerous build-up of medical waste during periods when roads are impassible.

During previous flood periods, when hospital waste could not be transported, “I was worried because the waste is toxic,” Lesrumat said. “It could cause health and environment damage if it accidentally spilled into the community.”

Run-ins with al Shabaab militants can also be a hazard for some medical workers in Kenya driving long distances in their jobs, medics said.

“Northern Kenya is very expansive and has so many challenges that the government struggles to deliver services,” said Onyango Okoth the assistant commissioner of Samburu County.

Now the Wamba incinerator handles between 5 and 20 kilograms of medical waste a day.

As the burner operates, a young worker clad in protective clothing flips open the lid of the chamber to monitor the process of incineration.

Seeing the last batch of waste is almost eliminated, he reaches for a barrel containing an assortment of used rubber gloves, syringes and polythene waste, pours in some of the waste, mixes it with a forked rod and then replaces the lid to allow the incineration to continue.

The Centers for Diseases Control in Kenya estimates that every patient admitted in a hospital generates at least 0.5 kilograms of medical waste. The National Environment Management Authority requires every health facility to dispose of medical waste through incineration.

SOLAR INCINERATION?

The next step, Kenyan clean energy experts say, may be to begin incinerating waste using even more sustainable sources of energy, such as solar power.

“Kenya is investing heavily in alternative energy sources,” said Johnson Kimani of the Kenya Climate Change Working Group. “Solar and biogas should be factored into medical waste incineration if the government is committed to its pledge of achieving a green economy.”

James Lebasha, of the International Medical Corps, which helped construct the Wamba incinerator, said the burner may be just the first for the region.

“We hope to build more units in morthern Kenya to enable communities access this service,” he said. (Reporting by Kagondu Njagi; editing by Laurie Goering :; Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers humanitarian news, climate change, women’s rights, trafficking and corruption. Visit www.trust.org/climate)

from: http://www.reuters.com/article/2015/06/30/kenya-medical-energy-idUSL8N0ZG1M220150630