Sudan Medical waste Therapy Strategy


•    A burn rate of 25 – 30kg/hr.
•    Consists of two chambers to ensure significant reduction of emissions and be capable of temperatures in the range of 800-1000˚c.
•    Incinerator must be of a low maintenance design, be diesel fuelled and need no more than 15 amp 220-250 V power. KW consumption per hour should be stated.
(1)  What  are  main  differences  between  medical  incinerators:    YD-10C  and  TS10(PLC)?
(2)  After  combustion,  the  medical  waste  becomes  smoke?  Without  smell?  No  pollution?
(3)  What  should  we  do  to  release  the  smoke?    Prepare  a  pipe  to  direct  the  smoke  to  factory  outside?
(4)  Any  operation  guide  for  reference,  we  worry  that  it’s  difficult  to  operate?
•    The incinerator should also be able to run off a generator.
•    The incinerator should have option of tank and should use no more than 12L of diesel fuel per hour to burn 25- 30kg of waste.options for medical waste incineration for Kabul, Afghanistan
•    Design must be such to minimize risk to operators and have a simple start sequence to minimize operator training and skills
•    Solid waste reductions in the range of 90 – 97% should be routinely achieved.a central thermal treatment station in the city of Khartoum (9 million inhabitants) we started with two units of autoclave that treat up to 18 tons a day so far, and looking forward to add an incineration plant/s to serve for medical, pharmaceutical, and hazardous waste.


manufacturer of ha zardous waste incinerator in china

Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system
Imputing door Mouth Width (mm): 760*760 (approx.)
Chimney External Diameter (mm): 300 ± 10
Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max)
Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h
Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz

Per your advertisement for 300 kg.hr. Model – We need to know the price via return.

How many Kg. of Fuel would be required for running this Model 10 hrs. everyday.

We have our own Freight Forwarding Agent.

We had a Contract for Garbage Management before their Civil War for 120 Tons/Day for one Municipality in North Africa
Medical Waste Incinerator

Dual Chamber (Primary & Secondary) with insulation slabs (fully insulated internal refractory lining) along with

controlled air blower for each chamber

Insulation / Refractory Thickness: ≥ 100mm

Chamber plate thickness: ≥ 6mm

Fuel Type: Natural gas based on burning fuel in combustion chambers

Waste Capacity: ≈ 150 Kg/Day

Incineration capacity: ≈ 25 Kg/Day (Separate waste charging and waste removal doors)

Burners: At least with (02) burners of automated start and stop functions

Combustion efficiency: > 97%

Temperature: programmable temperature with temp monitoring system

Residence time: 2 second in secondary chamber

Heating value: 4000 Kcal

Temperature Range: ≈ min 800ºC to max 1200ºC

Electrical supply: 220V with single phase

Chimney Plate Thickness: ≥ 5mm

Water scrubber: Scrubbing using reagent like lime & should made of SS 10 gauge of non-corrosion properties and painted

exteriorly by equipment grade heat resistive enamel

Chimney Height: between 15-25 feet

китайские поставщики горелок

В простой конструкции с металлическим стальным барабаном электрический. в том числе:
Клетка для приема биомедицинских отходов;
Камера сгорания с камином с фильтром для улавливания золы;
Прикрытие;
Подача воздуха;
Турбина, позволяющая подавать воздух.
Температура горения: 1800 ° С. Соответствие европейским стандартам.
Поставляется со всеми необходимыми аксессуарами
Поставка инсинератора модели ПДР-18 в составе:

· Производительность 100 кг / час отходов с влажностью до 85%

? Две камеры сгорания

· Две полностью автоматические жидкотопливные струйные горелки

· Пульт управления

· Дизельный бак емкостью 250 л. с 2-мя дизельными трубопроводами, фильтром и клапаном.
Тип: для отходов животноводства
Производительность: 30 кг в час при максимальной нагрузке 120 кг.
GLP газ
Напряжение: 110-120 В
Панель полуавтоматического управления
Дымоход из нержавеющей стали на высоте 3,5 метра над мусоросжигательной печью.
Высокотемпературная окраска всего мусоросжигательного завода.
Входная дверь для погрузки и разгрузки.
Топливо Дизельное топливо 8 / керосин
Объем (м3) 0,57
Производительность 50 кг в час
Среднее время выгорания 5 часов
Внешние размеры
Длина 2000мм
Ширина 1100мм
Высота с дымоходом 3500 мм
Открытие двери
Внутренние размеры
(первичная камера)
Длина 1200мм
Ширина 620мм
Высота 660 мм
Операция
Мин. рабочая температура 9500C
Максимум. рабочая температура 13200С
Время пребывания во второй камере 2,0 секунды.
Вес 1850кг
Вспомогательные
Руководства по эксплуатации и техническому обслуживанию
Рекомендуемый список запасных частей
300 литровый топливный бак
Скорость горения установки – 100 кг / час.

Топливо – Дизельное топливо – 35 сек Редвуд

Габаритные размеры следующие:

Ширина 2261мм

Длина 3264мм

Диаметр дымохода – 390 мм

Высота дымохода – 8000 мм
Китайские производители мусоросжигательных печей, Мы перерабатываем 8-10 тонн отходов туш овец и их побочных продуктов в день. Ищем оборудование: горелки внутреннего сгорания (комбинированная подача топлива: природный газ и дизельное топливо), панель управления и систему фильтров. Диаметр инсинератора 20 см. Низкая теплотворная способность отходов составляет 4 кВт / кг. Мощность нагрева 4000кВт

China incinerator

Incinerator Of Burning Capacity 30 kg/hr = 1 No

The Incineration System comprises of:

I. Main Incinerator with

A. Refractory lined Primary and Secondary Chamber.
B. Refractory lined main charging door and ash cleaning door.

II i. 1 No. fully automatic oil burner for primary chamber.
ii. 1 No. fully automatic oil burner for secondary chamber.

III.Centrifugal forced draft combustion air fan with motor.

IV. Flow measurement device on the Pri mary & Secondary air ducting.

V. Auto-loading in the form of Double FDV mechanism with outer gate
manual and inner motorized.

VI. Emergency stack / vent.

VII. High pressure Venturi scrubber of SS316 L

VIII. Cyclonic type droplet separator cum recirculation tank in Mild steel
rubber lined ( MSRL) construction.

IX. I.D. Fan with MSRL casing & SS 316 L impeller with motor.

X. Recirculation Pump (SS 316) with Motor along with piping & valves in
SS 316.

XI. Overhead HDPE Water tank for scrubber along with water piping
between tank and scrubber.

XII. Interconnecting ducting within the battery limits.

XIII. Instruments, valves, dampers and fittings within battery limits.

XIV. PLC based Control Panel with necessary instruments.

XV. Data recording device in the form of Printer.

XVI. Oil tank of 500 ltr capacity along with oil piping, valves & strainers
between tank & burner.

XVII. Operati ng tools & tackles like rake, hoe, shovel, two teeth scrapper.

XVIII. Caustic dosing system comprising of Tank- Agitator and pump

XIV. FUEL LDO DIESEL.

China cremación de animales

El panel comprenderá un compartimento para la conexión de cables de potencia y control. Pasaje para cables de alimentación y

Los cables de control estarán hechos por la parte inferior del cuadro de distribución.

El cajón se bloqueará en la posición de aislamiento mediante candados.

Se requiere la instalación de dos sistemas en el sur del Reino de Arabia Saudita. Los dos sistemas serán utilizados por

autoridad aduanera para quemar diferentes tipos de drogas. Se debe proporcionar todo el equipo necesario.

2. Garantía: los sistemas de cabina deben contar con una garantía de 3 años a partir de la fecha de aceptación. Todo lo necesario de repuesto

Las piezas, el mantenimiento preventivo, la reparación y el mantenimiento correctivo deben incluirse en el costo y proporcionarse al

cliente.

3. Se deben proporcionar todas las conexiones eléctricas y de agua necesarias.

4. Ambos sistemas deben ser de alta calidad y respetuosos con el medio ambiente.

5. La capacidad de cada sistema debe ser de hasta 100 kg / h.

6. El sistema debe tener alimentación automática.

7.Cada sistema debe constar de dos salas de combustión, una sala principal para quemar la droga y otra sala para quemar

los gases que se emiten como resultado de la combustión primaria.

8. El horno debe ser de acero resistente a la oxidación y con un espesor no inferior a 6 mm.

9.Cada sistema debe ser de alta eficiencia para quemar diferentes tipos de drogas, y debe tener una eficiencia del 99,9% para

quema de materiales orgánicos.

10. Los productos de desecho no deben exceder el 5%.

11. El sistema debe tener un sistema de encendido automático.

12. El sistema debe utilizar diesel (HSD) como combustible y no debe consumir más de 8 a 10 lt / h.

13. Cada sistema debe estar provisto de un tanque de combustible del tamaño adecuado para operar el sistema durante un día completo.

14.La temperatura en la sala principal debe ser de 850 C ± 50 C. El sistema también debe ser capaz de funcionar hasta 1050 C

C ± 50 C. el sistema debe ser capaz de funcionar de manera continua y debe estar provisto de un aislante de capa de cemento con

espesor adecuado.

15. El horno debe estar provisto de un aislante térmico para permitir una fácil operación.

16. El gas debe permanecer en la sala secundaria durante no más de 1,5 segundos.

17. La sala de combustión primaria debe tener al menos 2 quemadores.

18. La sala de combustión secundaria debe tener un quemador.

  1. Cada sistema debe tener puertas para cenizas, salida de aire a la chimenea y ventanas para permitir mirar hacia adentro y hacia

mantenimiento.

20. Cada sistema debe tener un sistema de filtrado para el procesamiento de gas con 2 tanques que utilicen agua corriente. Cada tanque de agua

debe tener una capacidad de 1000 lt y debe estar fijada al sistema y provista de indicador de nivel de agua.

21. Cada sistema debe tener una tecnología especial para separar los productos de la cintura y la humedad después del procesamiento del gas.

22. Cada sistema debe tener capacidad de enfriamiento después de la operación.

23.Cada sistema m debería estar provisto de un tubo de escape de 250 mm de diámetro y 10 m de altura. La base del escape

El sistema debe ser de 1000 mm. El tubo de escape debe ser de 6 mm y debe estar provisto de aislante térmico. El escape

El sistema debe estar provisto de un indicador de presión. También debe proporcionar escalera y pararrayos.

24. Potencia eléctrica: debe ser de 220 voltios, trifásica, 60 Hz y el motor no debe ser inferior a 15 HP.

25.Cada sistema debería estar provisto de un panel de control e indicadores y el equipo de seguridad y los sistemas de alarma necesarios. La

El panel de control debe mostrar al menos la temperatura en las habitaciones primarias y secundarias y en los inyectores de los filtros y

carga.

26.Cada sistema debería estar provisto de un sistema de alarma para cualquier avería o defecto de cualquier componente del sistema.

27.Se deben proporcionar las siguientes herramientas de protección personal:

a. Prendas resistentes al calor para 20 personas.

Afterburner Preheat Heater


PRIMARY CHAMBER

Durable steel casing

Top-notch refractory cellular lining and also insulation Large complete measurement leading loads counteracted door
1 x oil/gas terminated ignition burners ran on/off

SECONDARY CHAMBER

Tough steel casing

Premium refractory lining as well as also insulation 2 second gas residence time
1 x oil/gas discharged ignition burners ran on/off

SMOKESHAFT

Heavy-duty stainless steel casing

CONTROL BOARD

Control of primary along with 2nd burners Temperature degree Talking to 4 figure display screen Thermostat control tool for heating system (gas saver) Timer control 0- 12 hrs

Important follower timer control

Technical Specs

Gas
Diesel

Ability
900kg (1.35 m ³)

Burn Rate
150kg/h

Avg Ash Residue
3%

Avg Fuel Consumption p/hr
20ltr

Operation
Minutes. Operating Temperature 950 ° C. Max. Running Temperature Level 1320 ° C. Residency Time in Second Chamber 2 Secs.
Temperature level Tracking YES

ANCILLARIES

Operating and maintenance guidebooks Conserves list

TRICK FEATURES

– – Afterburner Preheat

– – Incineration temperature degrees over of 1300 ° C

– – 5mm steel covering as well as totally shield

– – Dense refractory concrete lining rated to 1600 ° C


установка для сжигания клинических отходов китай

Установка для сжигания медицинских отходов, Китай, Проектирование, поставка и производство на заводе одной установки для сжигания медицинских / общих отходов Surefire Manual Load TS50 / 1, как указано ниже: –

· Тип отходов: смешанные типы отходов o, 1, 2, 3 и 4, опасные для больниц / клинических учреждений.

· Плотность отходов: от 125 до 350 кг / м3

· CV отходов: 4000 ккал / кг

· Содержание влаги: 10-25%

· Расчетный остаток золы: 5-10%

· Номинальная производительность: загрузка партии 30 кг / час.

· Вторичная камера: 0,5 секунды при 850oC
· Компактный лабораторный стиль

· Две камеры сгорания

· Экологически чистый

· До 50 кг отходов / час

· Для животных

BURNING AND INCINERATION OF SOLID WASTE

Biomedical Waste                    Any solid or liquid waste which may present a threat of infection to humans including non-liquid tissue, body parts, blood or blood products and body fluids, laboratory and veterinary waste which contains human disease- causing agents, and discarded sharps (i.e. syringes, needles, scalpel blades).

 

Bottom Ash                                 The course non-combustible and unburned material which remains at the burn site after burning is complete. This includes materials remaining in the burn chamber, exhaust piping and pollution control devices where such devices are used.

 

Burn Box                                      A large metal box used to burn solid waste. Combustion air is usually supplied passively through vents or holes cut above the bottom of the box. An exhaust pipe or stack may or may not be attached.

 

 

 

 

Commercial Camp                   A temporary, seasonal or multi-year facility with a capacity greater than 15 people and which has been established for research, commercial or industrial purposes. A commercial camp does not include a traditional camp or field camp.

 

Commissioner’s Land             Lands that have been transferred by Order-in-Council to the Government of Nunavut. This includes roadways and land subject to block land transfers. Most Commissioner’s Land is located within municipalities.

 

Contaminant                             Any noise, heat, vibration or substance and includes such other substance as the Minister may prescribe that, where discharged into the environment,

  • endangers the health, safety or welfare of persons,
  • interferes or is likely to interfere with the normal enjoyment of life or property,
  • endangers the health of animal life, or
  • causes or is likely to cause damage to plant life or to propert

 

Determined Effort                    The ongoing review of opportunities for reductions and the implementation of changes or emission control upgrades that are technically and economically feasible and which result in on-going reductions in emissions. Determined efforts include the development and implementation of waste management planning which is focussed on pollution prevention.

 

De Novo Synthesis                   The creation of complex molecules from simple molecules.

 

Environment                              The components of the Earth and includes

  • air, land and water,
  • all layers of the atmosphere,
  • all organic and inorganic matter and living organisms, and
  • the interacting natural systems that include components referred to in paragraphs (a) to (c) above.

 

Field Camp                                  A temporary, seasonal or multi-year facility consisting of tents or other similar temporary structures with a capacity of 15 people or less and which has been established for research, commercial or industrial purposes.  A field camp does not include a traditional camp or commercial camp.

 

Fly Ash                                          Unburned material that is emitted into the air in the form of smoke or fine particulate matter during the burning process.

 

Hazardous Waste    A contaminant that is a dangerous good and is no longer wanted or is unusable for its original intended purpose and is intended for storage, recycling, treatment or disposal.

 

Incineration                                A treatment technology involving the destruction of waste by controlled burning at high temperatures.

 

 

 

 

Incinerator                                  A device or structure intended primarily to incinerate waste for the purpose of reducing its volume, destroying a hazardous substance in the waste or destroying an infectious substance in the waste. An incinerator has means to control the burning and ventilation processes.

 

Inspector                                     A person appointed under subsection 3(2) of the Environmental Protection Act and includes the Chief Environmental Protection Officer.

 

Modified Burn Barrel              A metal drum used to burn waste that has been affixed with devices or features which provide limited increased heat generation, heat retention and holding time.

 

Open Burning                            Burning of waste with limited or no control of the burn process. For clarity, open burning includes burning on the open ground or using a burn box or unmodified or modified burn barrel.

 

Qualified Person                       A person who has an appropriate level of knowledge and experience in all relevant aspects of waste management.

 

Responsible Party                    The owner or person in charge, management or control of the waste.

 

Smoke                                  The gases, particulate matter and all other products of combustion emitted into the atmosphere when a substance or material is burned including dust, sparks, ash, soot, cinders and fumes.

 

Solid Waste                                 Unwanted solid materials discarded from a household (i.e. single or multiple residential dwellings, other similar permanent or temporary dwellings), institutional (i.e. schools, government facilities, hospitals and health centres), commercial (i.e. stores, restaurants) or industrial (i.e. mineral, oil and gas exploration and development) facility.  For clarity, solid waste does not include biomedical waste, hazardous waste or sewage sludge.

 

Traditional Camp                      A temporary or seasonal camp used primarily for camping, hunting, fishing or other traditional or cultural activities. A traditional camp does not include a field camp or commercial camp.

 

Unmodified Burn Barrel         A metal drum used to burn waste that has not been affixed with devices or features which provide for enhanced heat generation, heat retention and holding time.

 

Untreated Wood                      Wood that has not been chemically impregnated, painted or similarly modified to improve resistance to insects or weathering.

 

Waste Audit                                An inventory or study of the amount and type of waste that is produced at a location.

 

 

MEDICAL WASTE INCINERATOR (50 C 60kg/hr)



Medical Waste Incinerator, 50 to 60 Kg/hr
Support Health Sector Support Project
Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals
1.    General Description
Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.
Main unit
Application For incineration, general and pathological
Capacity   50 C 60 kg/h burn rate
Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit
Operating time                Minimum 8 hours daily
Operating temperature     From 850 0C to 1200 0C, Automatic controlled
Residual Ash                    5 to 10%
    3.2     Primary Chamber
Construction Constructed from heavy duty mild or aluminized  steel Or
equal and approved equivalent
Insulation material            Refractory material lining similar or equal to calcium 
Silicate and hot face combination of heavy duty brickwork
Internal Construction        Fixed hearth type complete with gratings, concave bottom
and charging door, lined with refractory material
Charging Door                   Suitable for manual loading of wastes and with smooth 
Dear seal equivalent of Ceramic seals with hinges.
Door Lock                          Automatic, Electric type
Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber
Gratings   Provided
Loading Manual loading of waste
Primary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                    
Blower Provided. For supplying excess combustion air through the distribution system with speed control system
Temperature Minimum exit 850 0C
Observation port To be provided with protective glass type
Construction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalent
Insulation Refractory material lining
Combustion Temperatures        Above 850 0C, controlled electronically
Gas residue or retention Time       > 2 second at minimum 850 0C
Secondary Burner                    Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system,                                                                  Flame detector, Air fan, Complete with safe
ty features, flame failure Diesel fired fuel injector type.                                                                  Flange mounted
Ejector Provided, Venturi type, for cooling the flue gases
Combustion Air Fan Provided for supplying combustion and creating a negative drift and turbulences
Temperature Maximum  1600 0C


Incinerator to cut black bag landfill waste

30 August 2013 Last updated at 21:18 BST

Five councils in south east Wales have formed a partnership to deal with black bag waste in a bid to cut down on rubbish going to landfill.

The authorities aim to incinerate waste which cannot be recycled and convert it into power in a new project which is receiving a £4m annual grant from the Welsh government.

Environment correspondent Iolo ap Dafydd reports.

Article quoted from the networkQQ图片20160218145327