Controlled air medical waste incinerator designed for incineration of bio-medical waste



Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION



Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Самая крошечная горелка 30 кг

Стандартные 30 кг в час

*** Камера для ключей (200 литров)

*** Вторая камера

*** Смесительная камера сгорания

*** Дымовой вал из нержавеющей стали (1 метр)

*** Масляная горелка итальянского производства (2 комплекта)

*** Сухой скруббер

*** Вес 1,7 т (можно уменьшить до 1,0 пучка)

Основные запасные части (стандартные для мусоросжигательного завода, и в настоящее время цена состоит из):

*** 2 коллекции Italy Oil Heater

*** 2 комплекта датчика уровня температуры

*** 1 установленный экземпляр управления

*** 1 установленный последователь воздуха

*** 1 комплект дизельного масляного бака

*** 1 комплект для обслуживания продукта



HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-06-24

hog incinerator

(B) Features and Specifications  of the Steam Boiler: Features of the Boiler:

  • It must be an Electrical boiler
  • Splash proof electric enclosure and switches
  • Door Isolator to main electric enclosure
  • Alarm lights and Safety/protection against excel pressure
  • Level control on feedback water tank

 

Technical Specification of the Boiler:

  • Output: between: 90-110 kg/h (F&A 100 deg C)
  • Working pressure : between 7-10 bar
  • Boiler water content : between 80-100 litre
  • Feed water take content : between 60-80 litre
  • Power consumption : between 60-75Kw
  • Number of Heating Elements: 3-4 nos.
  • Electrical requirements: 400Vac, 50 Hz, 3 ph

 

(C) Technical Specifications of Tab washer Features:

  • Fully automatic and manual modes.
  • Metal construction, SA 240/304
  • Sensors to maximize both machine efficiency and operator safety.
  • Must use Re-circulating cold wash water to minimize water consumption and operating costs
  • Disinfects all bin surfaces
  • Uses Powerful blow dryer to remove excess surface water
  • Must be compliant with all North American and EU regulations

 

Specification:

  • Tub washer able to wash bins of a suitable size, the norm being 38 g
  • Must have an water reservoir of capacity minimum: 225 litre
  • Perfectly suited for hospitals and clinics by processing up to min. 300 bins per hour.
  • Time to wash and dry one bin after loading approximately 30 secs.
  • Bins loading on wash station at a time — approximately 12 nos.
  • Overall length : approx 30.0 feet
  • Overall height : approx 8.0 feet
  • Overall width: between 3.0-3.5 feet
  • Height to Conveyer from ground: approx 3 feet.

 

Drive of the Tub washer:

  • Motor driven
  • Moto: Horsepower: approx 4.0 HP
  • Power: 220 vac, 1ph or 400 VAC, 3 ph or the suit customer needs

 

Bins to be included:

  • 200 nos with different color (based on the requirement of the hospital)

Pet crematorium up to 200KG/day

Animal Crematory Incinerator

Capacity: Average 80kgs per feeding



Item

Specification

Model

A900

Internal Dimensions

120 x 90 x 85 CM

Suit for Animal

Cat – yes

Dog – yes

Pig – small

Cow – no

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters

*(upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 03 sets

Oil Tank (if oil fuel): 500Liters

















Model

A900

Picture

Burning Rate

Average 30 kgs/hour

Feed Capacity

Average 80 kgs/feeding

Primary Combustion Chamber

900 Liters

Secondary Combustion Chamber

300 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.5 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 34 kg/hour

Gas Consumption (Natural Gas)

Average 41 m3/hour

Internal Dimensions

120 x 90 x 85 cm (primary chamber)

External Dimensions

200 x 160 x 310 cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

60 x 80cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Combustion Chamber Material

Refractory Concrete Cement(No Brick)

Equipment Gross Weight

6000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal



 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

MEDICAL WASTE INCINERATORS

MEDICAL WASTE INCINERATORS for furnishing, installing, adjusting, and testing automatically controlled air medical waste incinerators having a capacity to burn 75 Kg/hour waste materials of biological and pathological nature.

The process of incineration provides the advantage of volume reduction as well as the ability to dispose of recognizable waste and sharps. On site incinerators provide a quick and easy way of disposing medical waste. This is the most widely accepted and feasible method of managing highly infectious waste.
The incinerator will be of the controlled air type, designed for (6-8) hour-day operations and rated at 75 kg per hour. The incinerator plant will include the following:
3Continuous loading using hydraulic ram feeder o Burners and fuel system
o Fans
o Pumps
o Controls and Instrumentation o Chimney and flue connections
o Incinerator loader for loading hoppers or carts o Ash handling equipment
41 year spare parts
5Waste weighing equipment
6Wheeled 2.0m3 waste storage hoppers (number to be decided by hospital managers)
7Incinerator loader
8Incinerator building, including fire safety equipment
9Platform and portholes designed to USEPA standards to facilitate stack testing.

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL (AMCA) AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)
AMERICAN WELDING SOCIETY (AWS)
ASME INTERNATIONAL (ASME) Sheet, Cold-Rolled, Carbon, Structural,
High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardened
SECTION 11 82 21 Page 6
ASTM A53/A53M (2010) Standard Specification for Pipe,
Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless ASTM A653/A653M (2010) Standard Specification for Steel

Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Gal annealed) by Hot-Dip Process FM GLOBAL (FM)
ISA – INTERNATIONAL SOCIETY OF AUTOMATION (ISA)
MANUFACTURERS STANDARDIZATION SOCIETY OF THE VALVE AND FITTINGS INDUSTRY (MSS)
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
U.S. DEPARTMENT OF DEFENSE (DOD)
U.S. GENERAL SERVICES ADMINISTRATION (GSA) UNDERWRITERS LABORATORIES (UL)

Горелка с подвижной платформой и автомобилем. Дверь, а также стиль для организации кремации домашних животных

Стиль для кремационного бизнеса домашних животных

Подвижная система и автомобиль. Дверь

Самостоятельное размещение маленького питомца

Инсинератор с подвижной платформой и авто. Дверь и дизайн для домашних животных Бизнес по кремации человека

Модель

A1500

Изображение

Скорость горения

В среднем 150 кг / час

Емкость подачи

Стандарт 350 кг / кормление

Первичная камера сгорания

1500 литров

Вторичная камера сгорания

500 литров

Камера сгорания смеси

да

Камера дымового фильтра

да

Настройка подачи

Руководство по эксплуатации

Напряжение

220В / 380В

Тип газа

Дизельное топливо / полностью природный газ / сжиженный нефтяной газ

Горелка

Италия Оригинал

Расход масла (дизельное топливо)

В среднем 53,0 кг / час

Забор газа (газ)

В среднем 63,6 м3 / час

Внутренние измерения

150 x 100 x 100 см (основная камера)

Внешние размеры

240 x 170 x 380 см (без дымохода)

Отображение уровня температуры

да

Возможность масляного контейнера (если нефть газ)

300 литров

Открытие двери

59 х 81 см

Длина дымохода

10.0 метров

Тип дымового вала

Нержавеющая сталь

Вес брутто устройств

8000 кг


HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-06-26

Especificaciones ambientales de emisiones al aire CA

Las necesidades de escape de aire desarrollan restricciones sobre la cantidad de contaminantes que pueden lanzarse al ambiente.

Tabla 1. Demandas de emisiones al aire para incineradores de desechos sólidos

Requisitos Criterio numérico Descripción

Dioxinas y Furanos
80 pg I-TEQ / metro cúbico
El dispositivo de procedimiento es picogramos de toxicidad internacional.
Coincidencias por metro cúbico de aire

Mercurio
20 µg / metro Rcúbico
El sistema de tratamiento es de microgramos por metro cúbico de referencia (la cantidad de gas adaptada a 25oC y adicionalmente 101,3 kilopascales)

La opacidad es el nivel al que los gases de escape disminuyen la transmisión de luz y cubren la vista de cualquier tipo de elemento del fondo. Se expresa como una porción que representa el grado de cobertura de las cosas observadas con los gases. No es un requisito de descarga, la opacidad ofrece una indicación de la eficacia general del quemador durante el funcionamiento normal2. El requisito de opacidad en la chimenea del quemador no debe exceder el 5%. Si bien no está previsto que los niveles de opacidad superen el 1% al 2% con el procedimiento normal, valores superiores al 5% recomiendan que el quemador no esté funcionando correctamente y se requiere un examen de funcionamiento incluido además de la alteración.

Figura 6 – – – – Instancias de puntuaciones de opacidad de humo
Las clasificaciones de opacidad son cotizaciones de precios y se atienden solo a objetivos ilustrativos.
Centro y también las mejores fotos gracias a la División de Medio Ambiente y Recursos Naturales de GNWT

healthcare facility burner


Supply, arrangement and also screening of medical waste burner with an ability of 75 kg/ human resources gas (LPG) total amount with all devices and also as a result with the chimney based on the technical specs along with problems of public wellness
make a room for the burner that fit 3 burners as in thing 3.1.1 as well as affixed to the heater space waste store that match waste for a duration of 7 days as well as all the structures of boosted concrete with preparingg heater structure as well as also store with all the job of wiring, electric as well as illumination systems, water as well as likewise sanitation
supply incinerator structure in addition to the waste storeroom with a fire snuff out sprinkler system counts on the resource of the water from network of teh basic website, in addition to a fire alarm system consists of noticing systems for cozy, smoke as well as this system is related to the medical facility emergency situation alarm system systems
Supply, arrangement along with testing of the air circulation system of the burner room and additionally the stockroom with fans ROOF COVERING LEADING EXHAUET FANS supplying them with filters with high efficiency (HEPA FILTER trip to draw followers with taking the air modification price of 5 times per human resources with streams and additionally air needed grilles
Supply, arrangement, checking various conditioning system for waste database DUCTED SPLIT UNITES and capability sufficient to maintain the interior temperature level at 14 levels Celsius in summer season as well as winter season
Supply, setup, testing of the air conditioning store of shielded premade wall surfaces inside the waste space with an ability of 35 cubic meters to save the clinical waste at a temperature of no Celsius till losing consisting of the cooling device and also all accessories
RISKY wood.
play hardwood.
petroleum residual waste.
hydraulic hose system.
calcium hydroxide bags.
bags or wood boxes including cyanide.
medical waste.
filters.
pharmaceuticals.
NO HAZARDOUS sawdust.
plastic.
plastic as well as likewise textil awnings.
wood.
plastic bathtubs.
rubber.
hygienic waste.
EPPs.
plastic bags.
structure and also building and construction reoccuring.
infected dustcloths or towels.
plastic or packaging of food.
polyestirene recipes, glasses, spoon, fork, etc.Capacity burner medical waste to high burning temperature degree.
With an electric gizmo to shield the setting as well as with 2 combustion chambers furnished with burner or oil.
– – heater to lose big volume things of 70 centimeters.
discrepancy: Automatic Control System.
– – harmful ability from 20 to 30 kgs.
First-room/ Temperature level = 900 ° C combustion.
2nd space/ Temperature degree = 1200 ° c afterburner


Burning capacity 50kg/hr with wet scrubber with dual fired burner

This model is small-scale waste incineration equipment for small waste output. 
Construction is dual/double combustion chamber with 02 units oil/gas burner. 
Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary 
combustion chambers and included mix-combustion chamber. Waste load on the 
bottom of chamber. Incinerator panel control suit for local operation.

Model

YD-50 with wet scrubber

Picture

Burning Rate

Average 50 kgs/hour

Feed Capacity

Average 100 kgs

Primary Combustion Chamber

900 Liters

Secondary Combustion Chamber

200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Wet Scrubber(Washing Tower)

Feed Mode

Manual

Voltage

220V

Power

7 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

16.9 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

120x90x85cm (primary chamber)

External Dimensions

400x200x230cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

62 x 68cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

6000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal



 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.