Archive: March 15, 2023

Animal Cremation Equipment Prices

Basic Info.

Model NO.:animal cremation equipments china
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator incenrator capacity 100kg, incenrator with burner manufacture, incenratory, incenteraters, incentives for development of incinerator, incerator. Net, incin Italy, with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 
Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 
Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

incinérateur pour animaux de compagnie

L’usine d’incinération doit intégrer un tableau de contrôle pour sa procédure. Sur le panneau de contrôle, nous aurons un visuel

écran des niveaux de température de la chambre. Cet affichage esthétique doit gérer et garder un œil sur le brûleur ainsi que sur ses performances.

La capacité de destruction en poids sera de 60 Kg / h.

Il doit pouvoir fonctionner pas beaucoup moins de 10 heures / jour

Cet incinérateur doit avoir la capacité de détruire tous les déchets combustibles produits par les établissements de santé, les centres privés, les laboratoires de recherche,

instituts, etc.

Spécification de style: types A, B, C, D et E de déchets cliniques

Fournir, installer et tester des UNITÉS SPLIT À CONDUIT au magasin de déchets avec une capacité suffisante pour maintenir le

température à 14 niveaux Celsius en été ainsi qu’en hiver

Incinerateur

Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover
Origin:China
Production Capacity:1000 Sets Per Year

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimum installation on site.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Nanjing Clover Medical Technology Co., Ltd. is a leading incinerator manufacturer in China. We’re local manufacturer and one of the largest exporter of China. Burner chamber manufacturer, burner combustion, burner gas, burner gas combustion efficiency, burner for medical, burner incinerator LPG, burner untuk incinerator, burners for clinical waste, Now, you can find our incinerator product in the former Soviet Union area, Africa countries, Asia countries and Middle East area. Follow market conditions, we supply different model series and design details according to each order. Clover Medical believe that the best cooperation is trust. The relationship between customer and clover medical isn’t only buyer and seller, we expect to make success together.

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

professional waste heater


medical waste incinerator: medical waste and general waste
Capacity to burn waste: 400 — 500 kg/hr
Fuel: Diesel
Fuel Consumption: 10 litres/hr maximum
Incineration temperature: 950 – 1300 °c
Casing: thick (min 5 mm) Stainless steel casing and fully
insulated to withstand sea humidity
Voltage: 220/240 V or 380/415V
Frequency: 50 Hz
Feeding: automatic
Ash 1 leftovers removal: Automatic
Fuel gas filtration system: Yes
Warranty: 12 months
Staff training: Operator & Maintenance staff
Operation and service manuals: 3 sets each
Especifica??es Gerais     6 mm plate steel sheel construction
11cm 1400°C refractory Liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000°C
400°C silicone Based finish paint
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1.36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service     220/50
System weight    5,700kg
Dimension “D”    152cm
Doad port height e    60x60cm
Ash port height e    36x36cm
General Specifications    6mm plate steel sheel construction
11cm 1400 ° C refractory liner
temperature controlled Burners
secondary combustion burners
interlock switch on load doors
separete ash door
one secondary residence @ 1000 ° C
400 ° C silicone based paint finish
alloy temperature sensor
factory wired and tested
Capacity    20kg/hr
primary Chamber    1607 L
Hearth area    1:36 aq.m
Secondary Chamber    694L
Primary burner (oil)    420.00btu
Secondary burner (oil)    900,000 btu
Secondary combustion    1/6 hp
Exhaust stack    46cm x 6m
Electrical service    220/50
System weight    5.700 kg
Dimension “D”    152cm
Doad port height and    60x60cm
Ash port height and    36x36cm
medical, hospital, veterinary and industrial wastes by medical waste incinerator Process.
So, we’re interested with your Incinerator plants, and we’d like to get quotation and key features description of different capacities of your Incinerator plants, concerning: small models (5 – 25 kg/hr); medium models (25-50 kg/hr) and big models (50-100 kg/hr) and plus.


Vertical Solid Rubbish Incinerator

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

The TS PLC model incinerator come instead of SYC model now. SYC model incinerator included model SYC-10/20/30/50/100 and now these model stop supply for market. We provide updated TS PLC versions, more work, PLC controller, stainless steel chimney and reasonable price. TS PLC model incinerator, included TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC).

Крошечный нагреватель 30 кг

Стандартные 30 кг в час

*** Секретная камера (200 литров)

*** 2-я камера

*** Смесительная камера сгорания

*** Дымовой вал из нержавеющей стали (1 метр)

*** Масляный обогреватель итальянского производства (2 комплекта)

*** Сухой скруббер

*** Вес 1,7 т (может уменьшиться до 1,0 лота)

Компоненты Trick Spare (Стандарт для инсинератора, а также цена указана на данный момент):

*** 2 коллекции Италия Oil Heating system

*** 2 комплекта датчика уровня температуры

*** 1 разработанный экземпляр управления

*** 1 разработан Air Follower

*** 1 установленный дизельный масляный бак

*** 1 установленный элемент обслуживания



HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-06-24

fournisseur de brûleur

Brûlage «PYROLYTIQUE», en contrôlant la gazéification des déchets

Le producteur de l’incinérateur doit se tenir à l’écart du lancement de fumée noire ainsi que de grandes poussières, pendant les chargements.

Il pourra réduire la quantité de déchets de 98%.

Il doit avoir la capacité de retenir la décharge dans le deuxième hangar avec une résidence de gaz d’au moins 2 secondes.

L’incinération doit être complètement sans fumée visible ni odeurs désagréables.

1.0 Le brûleur d’allumage principal doit fournir l’allumage des déchets à 850 ° C et doit s’éteindre pour économiser le carburant.

La chambre de combustion des clés doit être construite à partir d’une plaque d’acier robuste et le système est également doublé à l’intérieur d’un

couche complète d’isolation réfractaire et haute performance.

Le diamètre intérieur du Smokeshaft un minimum de:? 400 et aussi son dénivelé: 8 m

Medical Waste Treatment

Basic Info.

Model NO.:medical waste incinerators
Type:Incinerator
Export Markets:Global

Product Description

Key Attributes:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long lifetime of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.  * PLC Control Plane. *according to order  New Design for pet animal cremation business.  * One year guarantee on incinerator and parts in stock.  Application Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be termed many words as under: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 

Waste substance: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator fuel: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), garbage destructor, garbage destructors, tube incinerator for paint and crematory, turbulance in incineration, two room incinerator, two chambered incinerator, Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Small Hospital Incinerators

Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover
Origin:Nanjing Clover

Product Description

Nanjing Clover Medical Technology Co., Ltd..

The TS PLC model incinerator come rather than SYC model now. SYC model incinerator included model SYC-10/20/30/50/100 and these model stop supply for market. We provide updated TS PLC versions, more function, PLC control, stainless steel chimney and fair cost. TS PLC model incinerator, included TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC).

hog insinerators

Finish

All equipment shall be painted with a coat of zinc rich primer and two coats of high temperature heat resistant

polyurethane type paint. All painted surfaces shall be prepared by either steel shot cleaning or sand blasting.

 

Identification and Name Plates

Identification and name plates containing the manufacturer’s name, model number, serial number, and other pertinent

information shall be securely fastened to the unit in readily visible locations.

 

Fuel Type and Tank

All burners shall be fuel oil (diesel) fired. For all incinerators fitted with fuel oil (diesel) type burners, the

bidder shall supply and install 1000 litres steel tank and all the necessary piping and fittings and initial supply of

1000 litres fuel oil. Where existing fuel is found to be still in good condition from site inspection, contractors must

use existing tanks and therefore must clearly specify in their bids of such usage. The tank shall be positioned at

least 2 meters above ground on steel frame next to the incinerator shed. Fuel delivery to incinerator burners shall be

by gravity feed. The tank should be fitted with a drain plug as standard.

  1. Post – combustion chamber:

Medical waste incinerator

Standard requirement:

The medical incinerator should meet the European standards 2000/76/EC.

Basic requirements:

1-Capacity 100kg/hr.

2-Work for 24 hours.

3-Unit should have enough combustion room consists of two combustion chambers (mounted vertically)

4- Unit should supply with control methods for air entry to the primary and secondary chambers and hence incineration

of the waste is accomplished.

5-The unit charging is done automatically and have an option to be done manually.

6-The ash removal is done automatically and have an option to be done manually

7-The unit should have a dry filtering unit.

8-The unit should be controlled from the control panel.

control panel :

Should show different tasks of operation using (PLC)

-Temperature in combustion chamber

-time of operation and combustion.

-different pressures.

-amount of air in combustion.

-efficiency indicator.

-emergency system in case of increasing pressure or temperature.

f- Time for gas passing:

Minimum time required for passing to combustion chamber for oxidizing 0.5 seconds at 800 degree Celsius .

1- design details:

A-primary combustion chamber:

Oxidize all waste to combustion residuals and temperature not less than 800 degree Celsius.

b- Secondary chamber:

Continue combusting combustion gas residuals and hanging particles using additional burner temperature not less than

1100 degree Celsius and this conditions is reached by harmonizing between temperature and time of passage to ensure

adequate oxidizing supplying enough air to ensure turbulence of gas all the time this is controlled from control panel.