Model YD-100 delivery to Iraq”

There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several construction sites and all fuel type is diesel oil.

Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

 

Model YD-100
Burning Rate 100 kgs/hour
Feed Capacity 200 kgs
Paimary Combustion Chamber 1200 Liters
Secondary Combustion Chamber 500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 0.9Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 14–28 kg/hour
Gas Consumption (Natural Gas) 10–32.2 m3/hour
Internal Dimensions 130 x 100 x 90cm (paimary chamber)
External Dimensions 220 x 180 x 360cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 55 x 80cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 4300 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

Small Scale Medical Waste Coronovirus (Covid 19) Incinerator 30 kgs per hour Model TS30 PLC Auto Control

Items/Model

TS30(PLC)

Picture

 

Burn Rate

Average 30 kg/hour

Feed Capacity

Average 60kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Car Control and Display

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Consumption (N.G, m3n/Hour)

Average 16

Gas Consumption (L.P.G, m3n/Hour)

Average 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

55x50cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

3000kgs/4000kgs

External Dimensions


HICLOVER – Medical Environmental 

175x120x140cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Diesel/LPG/LNG burning key burning chamber/primary combustion incinerator

Main burning
Diesel/LPG/LNG burning key combustion chamber/primary combustion zone
Second burning
Home time in the second chamber not less than 2 secs
Both key as well as the secondary temperatures preserved up until all the waste has actually been completely ignited
Chimney
Chimney with a minimal height of 4 meters above ground level
Minimum leave velocity of the discharges not much less than 10 metres/second
Temperature level Cautions
Distinct and/or visible alarm to warn the driver when the second temperature drops to below the required temperature
General
Control box that can be separated as well as installed on different stand a minimum of 1.5 meters from burner at around 1.6 meter

heightItem 1
Burner design A

Melt Rate 65kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – – 2 Secs

– Fuel – Diesel/LPG/LNG, please show

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Plan for complete maintainability

10m Tube Pipe, suggest size

I000 Litre Gas Tank + Pipeline System, show volume

Additional smokeshaft expansion, indicate elevation

Service warranty, suggest no of years

Item 2
Incinerator design B

Melt Rate 150kg/h minimum

Weight (kg), please suggest:

Additional Chamber

Gas Retention Time – – 2 Seconds

Diesel/LPG/LNG, please show

Power Supply for Control Box- 220V-240V 50Hz solitary stage
Minimum operating temperature level 920 ° C, please indicate
One year Spare Parts Bundle for total maintainability
10m Hose Pipe, indicate size
I000 Litre Gas Storage Tank + Pipeline System, suggest volume
Added smokeshaft expansion, suggest elevation
Warranty, show no of years

Product 3
Incinerator version C.
Burn Rate 250kg/h minimum

Weight (kg) please show:.
Second Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V 50Hz single stage.
Minimum running temperature 920 ° C, please suggest.
One year Spare Components Bundle for full maintainability.
10m Hose pipe Pipe, indicate size.
I000 Litre Gas Tank + Pipeline System, indicate quantity.
Extra chimney expansion, indicate height.
Warranty, indicate no of years

Heat Waste Incinerator

Capacity at least (4000) kg/day (( Day= 16 Working Hrs))

Ability at least (4000) kg/day (( Day= 24 Working Hrs))

With the following attributes:

* Automatic feeder as original part of the unit.

* Automatic ash/ leftovers elimination as initial component of the unit.

* Water Injection System to control the temperature> >

* Flue gas filtering system abiding by EU.

* Continual discharge tracking and recording system.

* It should include setup, testing, and also personnel training.

* 6 nos. of sturdy filling containers.

Item 4.
HTW Incinerator design D.
Burn Price – – 150kg/hour minimum.
Weight (kg), please indicate:.
Secondary Chamber.
Gas Retention Time 2 Seconds.
Gas Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V, solitary phase 50-60Hz.
Minimum running temperature 1200 ° C, please show

One year Spare Parts Plan for complete maintainability

10m Tube Pipe, show size.
1000 Litre Fuel Tank + Pipeline System, indicate quantity.
Extra chimney extension, suggest height.
Mobile Burner

Item 5.
Mobile Burner version E

Melt Price 50kg/h minimum

Weight (kg), please show:

Secondary Chamber

Gas Retention Time – – 2 Seconds

– Gas – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Bundle for full maintainability.
Mobile Incinerator

Thing 6.
Mobile Incinerator version F

Melt Rate 100kg/h minimum

Weight (kg), please indicate:

Second Chamber

Gas Retention Time – – 2 Seconds

– Fuel – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum operating temperature level 850 ° C, please indicate

One year Spare Parts Bundle for full maintainability

10m Pipe Pipe, suggest size

1000 Litre Gas Container + Pipeline System, show quantity

Additional smokeshaft extension, indicate height

Warranty, indicate no of years.
Heat Waste Mobile Incinerator.
Product 7.
HTW Mobile Burner version G.
Burn Price 100kg/h minimum.
Weight (kg), please suggest:.
Second Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – – 220V-240V 50Hz solitary stage

Minimum operating temperature 1200 ° C, please suggest.
Main burning.
Diesel/LPG/LNG burning main burning chamber/primary combustion zone.
Second burning.
House time in the second chamber not less than 2 seconds.
Both main and the secondary temperatures preserved up until all the waste has been entirely ignited.
Smokeshaft.
Chimney with a minimal elevation of 4 meters above ground level.
Minimum exit velocity of the emissions not less than 10 metres/second.
Temperature Warnings.
Audible and/or noticeable alarm system to advise the driver when the additional temperature goes down to below the called for temperature level.
General.
Control box that can be separated as well as mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter

elevation.
Guarantee, show no of years

incinérateur de déchets médicaux de Chine

Incinérer: déchets médicaux et déchets généraux

Capacité à brûler les déchets: 400-500 kg / h

Carburant: Diesel

Consommation de carburant: 10 litres / h maximum

Température d’incinération: 950 – 1300 ° C

Boîtier: épais (min 5 mm) Boîtier en acier inoxydable et entièrement

isolé pour résister à l’humidité de la mer

Tension: 220/240 V ou 380 / 415V

Fréquence: 50 Hz

Alimentation: automatique

Élimination des restes de cendre 1: Automatique

Système de filtration du gaz combustible: Oui

Garantie: 12 mois

Formation du personnel: personnel opérateur et de maintenance

Manuels d’utilisation et d’entretien: 3 ensembles chacun

  • Avec châssis à monter dans un camion / camion
  • Peut avoir une chambre de combustion primaire et secondaire
  • Doit avoir une chambre de dilution
  • Capacité: 100 Kgs par heure
  • Source d’énergie: diesel ou gaz naturel ou gaz naturel liquéfié
  • Les déchets généraux produits quotidiennement comprennent le papier, le plastique, les matières organiques, les boîtes, le plastique

contenants, feuilles, etc.

L’incinérateur à double chambre doit de préférence être conçu. L’alimentation en air dans la chambre primaire et secondaire doit être

réglementé entre 30% -80% et 170% -120% de la quantité stoechiométrique respectivement. Débitmètre / mesure de débit appropriée

dispositif doit être installé sur les conduits d’air primaire et secondaire. L’air de combustion doit être fourni par un

ventilateur à tirage forcé séparé tenant compte de l’air fourni par les brûleurs. Des dispositions doivent être prises dans le

chambre pour mesurer la pression de la colonne d’eau.

  1. Capacité: jusqu’à 4000 kg brûler pas moins de 500 kg / h
  2. Le revêtement réfractaire de la chambre doit être suffisamment solide pour supporter une température minimale de 1000dc dans le primaire.

chambre et 1200 cc dans la chambre secondaire. Les briques réfractaires et isolantes doivent avoir une épaisseur minimale de 115 mm chacune

& conforme à IS: 8-1983 et IS: 2042-1972 respectivement.

  1. La coque de l’incinérateur doit être faite d’une plaque SS / MS d’épaisseur adéquate (minimum 5 mm) et peinte à l’extérieur avec

peinture aluminium résistante à la chaleur adaptée pour résister à une température de 250 cc avec une préparation de surface appropriée. Doublure réfractaire

du conduit chaud doit être réalisé avec un moulage réfractaire (minimum 45 mm d’épaisseur) et un isolant moulable (minimum 80 mm d’épaisseur).

La laine de céramique doit être utilisée aux brides de conduit chaud et aux joints de dilatation.

5.Il doit y avoir un brûleur séparé pour la chambre primaire et secondaire. La capacité calorifique de chaque brûleur

doit être suffisante pour augmenter la température dans les chambres primaire et secondaire à 800 +/- 50dc et 1050 +/- 50dc respectivement

dans un délai maximum de 60 minutes avant le chargement des déchets. Les brûleurs doivent avoir une commande automatique de mise en marche / arrêt pour

éviter les fluctuations de température au-delà de la plage de température requise.

6.L’incinérateur doit avoir un dispositif d’enregistrement graphique ou informatique qui doit automatiquement et continuellement surveiller et

les dates d’enregistrement, l’heure du jour, le numéro séquentiel du lot, le Co, le Co2, l’O2 dans les émissions gazeuses doivent également être mesurés quotidiennement.

Construction en tôle d’acier de 6 mm

11cm 1400 o C L iner réfractaire

Brûleurs à température contrôlée

Brûleurs à combustion secondaire

Interrupteur de verrouillage sur les portes de chargement

Porte à cendres séparée

Une deuxième résidence secondaire à 1000 o C

Peinture à base de silicone 400 ° C.

Capteur de température en alliage

Câblé et testé en usine

Capacité-20 kg / h

Chambre primaire-1607 L

Foyer-1: 36 mètres carrés

Chambre secondaire-694 L

Brûleur primaire (huile) -420 000 btu

Brûleur secondaire (huile) -900,000 btu

Combustion secondaire-1/6 hp

Pile d’échappement – 46 cm x 6 m

Service électrique-220/50

Système de poids-5.700 kg

Dimension «D» -152 cm

Hauteur du port de chargement – 60x 60 cm

Hauteur du port de cendres -36 x 36 cm

  1. La conception structurelle de la cheminée / cheminée doit être conforme à la norme IS: 6533-1989 La cheminée / cheminée doit être revêtue de l’intérieur

avec au moins 3 mm d’épaisseur de caoutchouc naturel dur adapté aux conditions de service et doit également être conforme à la norme IS: 4682 partie

I-1968 pour éviter la corrosion de l’oxygène et des acides dans les gaz de combustion.

INCINERATEUR DE DECHETS HOSPITALIER

Requirements for Dual Chamber Burner

INCINERATOR DESCRIPTION
The Model is for up to 300kgs ability per batch tons as well as will certainly shed at around 55kgs per hour.
The unit has leading packing style and has a strong refractory concrete lining for optimum heat retention. Device have large leading cover for very easy loading, as well as specifically designed front ash door, for ash removal.
This unit runs at over 1100 ° C in the key chamber to guarantee complete combustion. This model also benefits
from a heavy duty secondary chamber as well as burner which makes certain a full re-burn of any smoke as well as exhausts as well as a 0.5 2nd gas retention time.
Melt rate 150kg/h minimum
Secondary Chamber Yes.
Gas Retention Time 2 seconds.
Gas Diesel/LPG/LNG.
Power Supply for Control Box 220V-240V 50Hz solitary stage.
Minimum Operating Temperature Level 920 ˚C

PRIMARY CHAMBER.
Durable steel case.
Excellent quality refractory lining and insulation.
Huge full dimension leading load door and liquid retention sill.
1 x diesel oil terminated ignition heaters operated on/off.
ADDITIONAL CHAMBER.
Heavy-duty steel housing.
Top quality refractory lining as well as insulation.
1 x diesel oil fired ignition heaters operated on/off.
Requirements for Double Chamber Incinerator:.
Primary Burning.
The main combustion chamber shall be approved as the key burning area.
The minimum combustion temperature of the key chamber shall not be less than 800 degrees c.
Secondary Combustion.
The house time in the second chamber will not be much less than 2 secs.
The gas temperature level as measured versus the inside wall surface in the secondary chamber, not in the fire zone will not be less than as suggested in Whole lot 1-7.
Both the main and also secondary temperatures shall be preserved till all the waste has been entirely combusted.
Chimney.
The chimney shall have a minimal height of 4 metres above ground level.
The minimal exit speed of the emissions will not be less than 10metres/second.
Temperature Warnings.
A distinct and/or noticeable alarm to alert the operator when the second temperature level drops to listed below the needed temperature.
General.
Control box can be separated and also installed on different stand of atleast 1.5 metres from the burner at approximately 1.6 metre elevation.
CE certified or equivalent for incinerators of this dimension and also design.
Drawings as well as images for the provided whole lots.
1 year spare parts, fuel tanks as well as 10metre pipe to come common with every burner.
Specs for Mobile Burner Units.
Trailer mounted mobile incinerator devices ideal for the following applications.
Medical waste.
Residential waste.
Industrial waste.
Animal cadavers.
SMOKESHAFT.
Durable stainless steel case.
1.5 m size.
0.6 m refractory lined stack.
CONTROL PANEL.
Control of 1 heater.
Timer control 0- 12 hrs.
Essential fan timer control.
Temperature Tracking.
Thermostatic Control.
Automatic Control.
Cycle time established.
ANCILLARIES.
Operating as well as maintenance handbooks.
Saves listing.
CONTAINERISATION.
incinerator totally installed within 10 ft ISO accredited container.
3,5 kwA electrical power generator, 1000 litres fuel storage tank.
Incinerator mounted on the silenblock padding.

CONTAINERIZED INCINERATOR FOR INCINERATING HAZARDOUS AND NON HAZARDOUS WASTES

Ø  FUEL DIESEL/NATURAL GAS; NUMBER OF PRIMARY BURNERS & RATING: 2 @ 250kw

Ø  NUMBER OF SECONDARY BURNERS & RATING: 2 @ 400kw; ELECTRICAL SUPPLY 230V 60Hz

Ø  BIN TIPPER, MONITORING SYSTEM, CLEANING SYSTEM

Ø  GAS CLEANING AND GAS MONITORING.MSW1000 General Medical Waste Incinerators burn rate up to 100kg/hr
The following should be signaling in the biding document
02. Number of laboratories    – 05

Ø  RAM LOADER CAPACITY 0.75M³; OPERATIONAL CYCLES PER DAY 8-16 Hrs.

Ø  FUEL DIESEL/NATURAL GAS; NUMBER OF PRIMARY BURNERS & RATING: 2 @ 250kw

Ø  NUMBER OF SECONDARY BURNERS & RATING: 2 @ 400kw; ELECTRICAL SUPPLY 230V 60Hz

Ø  BIN TIPPER, MONITORING SYSTEM, CLEANING SYSTEM

Ø  GAS CLEANING AND GAS MONITORING.MSW1000 General Medical Waste Incinerators burn rate up to 100kg/hr
A2400 Animal / poultry Waste Incinerators burn rate up to 200kg/hr.Laboratory  waste Management  system
01. Liqued water purification system.
02. Number of laboratories    – 05
03. The estimated liquid water waste    – 6000 L including
a. chemicals
b. toxins
c. Bio Hazardous materials.
Temporary allocated space for purifications system- 30×20
The following should be indicating in the biding document
1.Method of disposing treated waste water
2.Method of discarding the sludge
3.To follow ISO standard/regulations of Central Environment Authority[CEA]
4.Time frame for construction
5.Request the cost for each item of the project [Consultancy/designing/construction] as well for the whole project.
6.Warranty period and maintaincne.

Incinerator Temperature

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, incinerator capacity calculations, incinerator catalouge in pdf format, incinerator chamber, incinerator chambers, incinerator china clove, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

中國電子科技集團公司第十四研究所風淋室,傳遞窗以及隔牆改造

2019年05月22日 業績與案例 418 views

中國電子科技集團公司第十四研究所風淋室,傳遞窗以及隔牆改造

項目名稱:十四所風淋室,傳遞窗以及隔牆改造

項目簡介:十四所廠區潔凈室風淋室,傳遞窗以及隔牆改造

承接時間:2016.7





中國電子科技集團公司第十四研究所坐落於鍾靈毓秀的南京市,新所區佔地近2000畝,是中國雷達工業的發源地,國家諸多新型、高端雷達裝備的始創者,以及具有國際競爭能力的綜合型電子信息工程研究所。其前身為創建於1946年的“中華民國國防部特種電訊器材修理所”;1949年4月起義后被中國人民解放軍接管,先後直屬於第二機械工業部、國防部十院、第四機械工業部十院、國防科委第十研究院、電子工業部、信息產業部等,2002年起歸屬中國電子科技集團公司。

  十四所作為國家國防電子信息行業的骨幹研究所,牢記黨和國家賦予的神聖使命,發揮高科技優勢,服務國家安全,在電子信息裝備的研發、設計、製造、服務的一體化業務中具有領先的核心能力和國際競爭能力,先後在“兩彈一星”、“載人航天”、三峽工程、奧運安保等多項國家重點工程中承擔關鍵任務,受到黨中央、國務院、中央軍委的表彰和嘉獎。先後榮獲全國精神文明建設先進單位、全國五一勞動獎狀、江蘇省文明單位標兵等多項榮譽稱號。十四所在為國防建設做出積極貢獻的同時,按照“軍民結合、寓軍於民”的要求,堅持走軍民複合式發展、國際化發展的道路,積極投身於國民經濟建設。依託軍工科研優勢,十四所在現代物流、城軌交通、無線通信、民用雷達、軟件與集成電路等民用領域取得了快速發展,現已成為覆蓋國內、國際兩大市場的集團化研究所。

  在60年的自主創新發展中,形成了一支“特別能吃苦、特別能戰鬥、特別能奉獻”、富有創新精神的人才隊伍,現有5000餘名在職職工中,科研人員3000餘人,中國工程院院士3名,國家、省部級有突出貢獻中青年專家、享受政府特殊津貼專家130餘名。建所以來形成的自立自強、敢為人先的科技創新作風,以及擁有的國家重點實驗室、博士后科研工作站等一流的創新條件,使十四所取得了國家級成果獎60餘項,部、省級成果獎340餘項,一批項目獲“全國十大科技成就”、國家科技進步特等獎、國家科技進步一等獎等獎項。

更多內容 網址: www.ecolead.cn 電話: 025-57138032

Model YD-50 oil fuel incinerator for Moldova”

In the year 2010, we delivery 05 sets model YD-50 oil fuel incinerator for Moldova, near to Black Sea and Ukraine. The container shipped to Ilyichevsk port.

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.

Model YD-50
Burning Rate 50 kgs/hour
Feed Capacity 150 kgs
Paimary Combustion Chamber 900 Liters
Secondary Combustion Chamber 300 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 0.7Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 12.1–23.9 kg/hour
Gas Consumption (Natural Gas) 9.9–26.1 m3/hour
Internal Dimensions 120 x 90 x 85cm (paimary chamber)
External Dimensions 200 x 160 x 310cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 62 x 80cm
Chimney Length 5.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 4000 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

 

 

Medical Incinerator Yd-50

Product Description

Incinerator is a incineration gear, direct fire squander by gasoline fuel or oi fuel. As different circumscription, incinerator can be termed many words as under: 

Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant. 

Waste substance: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator fuel: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree