Archive: October 25, 2022

Temperature Control Incinerator

Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, extended life. *based on order  * High fever, long life of incinerator.  * Free or minimum installation onsite.  * High speed, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and components in stock.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Containerized Mobile Kind Tool Unit Waste Burner

Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).

Items/Model

TS50( PLC)

Image

Concept

Waste Incineration Therapy

Burn Price

Standard 50-100 kg/hour

Feed Capacity

Ordinary 200-300 kg/feeding

Control Mode

PLC( Programmable Logic Controller Incinerator)

Optional Upgrade Containerized Mobile Kind Incinerator

ISO 20′ ′ Complete Container

Burning Chamber

560L

Interior Measurements

1000x800x700mm

Second Chamber

280L

Smoke Filter Chamber

Yes

Feed Setting

Handbook

Voltage

210/240V 50Hz 1P

Power

1.3 Kw

Oil Consumption (kg/hour)

Ordinary 20.4( D.O)

Thermal ability( kw/hour)

166-332

Gas Consumption (m3/hour)

***

Temperature Level Monitor

Digital Display

Oil Tank

1000L

Feed Door

60x50cm

Chimney

10Meter

Chimney Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

7500kg

Outside Dimensions

260x160x250cm( without smokeshaft)


Model TS30 oil fired waste Little incinerator 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr.

Items/Model

TS30(PLC)

Picture

 

Burn Rate

Typical 20-30 kg/hour

Feed Capacity

Typical 60kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Typical 13.3

Gas Consumption (N.G, m3n/Hour)

Typical 16

Gas Consumption (L.P.G, m3n/Hour)

Typical 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

100L or More(Optional)

Feed Door

55x50cm

Chimney

5Meter or More(Optional)

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4000kg

External Dimensions

HICLOVER – Medical Environmental 

175x120x140cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Animal Crematorium Incinerators Rated for 60 Pounds Per Hour

Product Description

Waste Incinerator International Market Analytics 
Date. Jun. 10, 2012 
Download: Word format / PDF format 

Key Word: 
Small incinerators 
Medical waste incinerator 
Pet animal cremation incinerator 
Incinerator manufacturers 

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 
Incinerator fuel: Gas incinerator, oil incinerator 
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. "Dioxins" refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc. 

So, why we still use incinerator? 
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control. 
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two reason but not only above, we still use incinerators. 

How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, syc-10 incinerator, thermal oxidiser manufacturer, two chamber medical waste incinerator, waste incineration china, waste incineration furnace, waste incineration in china, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don't have gas supply system. 
And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc. 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products. 

Wrote by Nicky

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

incinérateurs médicaux en Chine

Les opérations de l’usine seraient-elles opérationnelles 24 heures sur 24, 7 jours sur 7, toute l’année, sauf

des périodes de maintenance régulière et préventive?

  1. Combien d’heures par an votre processus pourrait-il être opérationnel?
  1. Quelle serait votre approche pour des projets plus importants visant à valoriser 1 000 tonnes par jour?
  1. Quelle quantité d’électricité pourrait être produite en utilisant votre technologie basée sur une installation de 1000 tonnes par jour pour

valoriser les déchets urbains ayant un facteur d’humidité de l’ordre de 50% et un pouvoir calorifique de l’ordre de 2,5 MW / tonne de déchets à

l’entrée de la station de valorisation énergétique des déchets (c’est-à-dire avant le prétraitement des déchets)? Quel volume et caractéristiques de

les cendres seraient-elles produites à partir de cette valorisation des déchets solides?

  1. Quel serait le coût en capital nécessaire pour répondre à l’exigence de valorisation de 1000 tonnes par jour

déchets?

  1. Quel serait le prix de vente de l’électricité par kWh pour atteindre la rentabilité cible?
  1. Pourriez-vous valoriser les volumes de boues provenant des stations d’épuration et si oui à quelle humidité maximale

à quel facteur pourriez-vous exploiter la station?

  1. Étant donné que votre processus est un processus d’incinération, de l’oxygène sera nécessaire, il y aura donc

certaines émissions atmosphériques du procédé, comment contrôler les émissions atmosphériques pour respecter les normes environnementales?

  1. Quelle serait votre implication dans tout projet: prépareriez-vous l’ingénierie des procédés, la production d’électricité

ingénierie, ingénierie pour travaux de chantier, bâtiments, raccordement électrique au réseau électrique existant? As-tu

capacités de construction complètes ou auriez-vous besoin d’un partenaire local pour effectuer quelle partie de la construction

travail? Souhaitez-vous également exploiter la station ou utiliser un partenaire local pour exploiter la station?

  1. Avez-vous également la capacité de financement pour la conception, la construction et l’exploitation de tout projet? En Algérie,

un financement ne serait probablement pas nécessaire, mais cela pourrait être le cas dans d’autres pays où Gestech International

est actuellement impliqué dans.

incinerator producer 200kgs/h

Waste is thermally decayed in the main chamber at temperature levels of 800 ° C +. The resulting aeriform items are entirely oxidized in the second chamber at higher temperature levels with adequate resident time. Other specifications are as follows. A burning chamber of waste:

* Perfectly limited door for the manual loading of waste. The loading ought to be Manual, Set Load

* A burner of lights which the use is restricted to the ignition of waste.

* Frontage of loading with door seals risen on hinges, wheel of screw plug, flexible joint, as well as packing protecting out of refractory.

* The insulation of the burning chamber need to be made up of refractory bricks, having a high web content of aluminum and shields bricks in order to assure a minimum temperature on the outside sheet steel.

* Composition of the refractory

Burning Ability

Max. 200kgs/h

Supporting Gas

Diesel

Kind of Heater

Monoblock automatic heaters

Temperatures

Primary Chamber: 800 ° C ± 50 ° C. Additional Chamber: 1300 ° C ±

50 ° C. Kind. Static strong fireplace.

Product of Building and construction.

Mild Steel.

Refractory thickness.

115 mm thick.

Product.

Refractory blocks.

Insulation density.

50 mm thick.

Waste Charging.

Manual.

Ash Elimination.

Handbook.

Kind.

Static solid fireplace.

Material of Construction.

Mild Steel.

Refractory thickness.

115 mm thick.

Product.

Refractory blocks.

Insulation density.

50 mm thick.

Type.

Centrifugal.

Inflection.

Manual damper control.

Product of Construction.

Mild Steel.

Sort of temperature controller.

Digital.

End up & & paint kind.

Dual coat.

Material of construction & & capacity

. Mild Steel/ Plastic, appropriate capacity.

Other Standard Accessories.

Diesel oil degree sign, piping with shutoffs & & Non-return shutoff.

Aesthetic Monitoring of Gas.

Offered.

No. of Burners.

2 one in primary and also in second chamber).

Type & & Design

. Monoblock automated oil fired.

Make.

Riello.

Fuel.

Diesel.

Fuel shipment.

10 C 20 kg/h.

Discharging phase.

1.

Thermal power.

118 C 236 kW.

Motor power.

240 W.

Pump pressure.

10 C 12 bar (basic calibration), Max. pressure 15 bar.

Electrical supply.

Single phase 220V, 50Hz.

Material of building and construction.

Burned bricks.

Height.

9 meters from ground degree.

Medical waste incineration system

Medical waste incineration system of 300 kg/hr burn rate with dual fuel (Gasoline and diesel) type, daily 8-16 hrs operation and a stack height of 15 meter.Primary combustion

20.     Fan:
•    Post combustion: 1100oC.
The residence time in the secondary chamber shall not be less than two seconds;
Nature: 65% of Al203
14.    
.
15.     Fuel : diesel
* Carcass in strong sheet steel with assistance of link.
23. Capacity to treat Plastic: Not less than 40% by weight
8.     It should be able to hold emission in the next burn with gasoline residence of not less than two seconds.
The gas temperature as measured against the inside wall in the secondary chamber, not in the flame zone, will not be less than as indicated in Lots 1-7;
Control box watertight to dust, including:

* A switch circuit breaker for each engine (ventilators and burners).
* Burner with fuel, mono-bloc casting guiding type with flat flame, lighting and safety of     electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
This incinerator with”PYROLYTIC” combustion must have:
* A device of injection of air allowing a Whole recombustion of gases,
Nature: Calcium
22. Process Filtering system: Scruber to be mentionned as discretionary
* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

18.     A chamber of post combustion of gases
•    The Temperatures of combustion: Minimum will be 850oC and maximum 1400oC
21.     Controls and regulations:
2.    
* Composition of the refractory;
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
6.     The incinerator must prevent the discharge of black smoke and dust that is fine, (Smokeless) during the loadings.
13.    
5.     “PYROLYTIC” combustion, by controlling the gasification of waste.
22.     The provider must give batches of spare parts of first urgency and consumable of the incinerator.
•    Nature: Calcium silicate.
The minimum exit velocity of the emissions will not be less than 10 metres/second;1.     Capacity of destruction in weight: 60 Kg/h.
3.     This incinerator has to have the ability to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
* A sheath of evacuation of the gases burnt.
12.     The Amount of the combustion chamber: 1.200 L
16.     The provider must provide  necessary information for the best of  the installation
23.     The installed incinerator must bear a 1 year guarantee.
Both the primary and the secondary temperatures shall be maintained until all the waste has been completely combusted;

Chimney
7.     It should be able to reduce the quantity of wastes by 98%.
* A regulator with electronic viewing for the temperature of combustion.
23. Emission Standards Compliance: BS 3316 or équivalent standard
The chimney will have a minimum height of 4 meters above ground level;
9.     The incineration should be completely free from visible smoke in addition to offensive odours.
* A timer with adjustable temporization for the regulation of each burner.
10.     The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg

24. CE Manufacturing Compliance: BS EN 746-2-1997
. Nature: 42 percent of Al203
* Electric box.

21. The de- ashing has to be completed in the bottom of the combustion chamber or the deashing should be Automatic or manual batch p ashing.
. Thickness: ≥75 mm
* A regulator with electronic viewing for the temperature of postcombustion.
* Burner of light of waste, with gas, regular mono-bloc casting directing stirring flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
4.    
17.     A combustion chamber of waste:
From the mill; it will consist of curative and preventative maintenance, and the use of machine, etc

Small Size Waste Incinerator

Product Description

Application Scope 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

So, why we still use incinerator? 
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control. 
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two reason but not only above, we still use incinerators. 

How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model’s price around $5, 000usd per unit and large scale model’s price more than $50, 000usd per unit. So, before purchase one unit incinerator, you have to make clear following items: 
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is light oil burner incinerator design, liquid incinerators, livestock cremation equipment manufacturer, livestock crematory equipment, livestock crematory system, cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system. 
And other technology items, like power(220v, 380v), waste feed door type, incinerator structure, etc.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

250kgs per hr ability waste incinerator

Burner Model TS250 PLC, Review

This design is small-scale waste incineration tools for small waste outcome. Construction

is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. 
Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers
and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. 

Main Product List per 01 collection

Primary Burning Chamber

Additional Combustion Chamber

Smoke Filter Chamber

Incinerator PLC Control Instance

Smokeshaft:10.0 Meters

*( upgrade to Stainless-steel, complimentary expense)

Italy oil/gas heater: 02 units

Oil Tank (if oil fuel): 300Liters








Items/Model

TS200( PLC)

Picture

Principle

Strong Waste Incineration Therapy

Burn Rate

Average 250 kg/hour

Feed Capability

Standard 350kg/feeding

Control Setting

PLC( Programmable Logic Controller Burner)

Combustion Chamber

1800L

Internal Measurements

150x110x110cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Power

0.9 Kw

Oil Intake (kg/hour)

Ordinary 28

Gas Usage (m3/hour)

Typical 33.6

Temperature Level Screen

Digital Present

Temperature Level Security

Yes

Oil Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x190cm

Heater procedure ought to be Automatic On/Off

Gas : diesel

The vendor must supply required information for the best of the installment

This incinerator with “PYROLYTIC” combustion have to have:

;

・ Refractory concrete:

§. Density: ≥ 100 mm

§. Nature: 42% of Al203

・ Shield in coarse panels:

§. Thickness: ≥ 75 mm

・ Nature: Calcium silicate.

* Burner of illumination of waste, with gas, common mono-bloc casting directing diving flame, lights and also safety of electronic ignition, irreversible air flow, electro-magnetic sluice entrance of regulation as well as isolating valve.

* Plate of burning in Carborundum, avoiding the dealing with of glass as well as slags.

A chamber of article burning of gases

* A heater of burning of gases,

* A device of shot of air enabling a complete recombustion of gases,

* A tool of air inlet of air conditioning of waste gases,

* A sheath of emptying of the gases charred.

* Carcass in solid sheet steel with support of link.

* Structure of the refractory;

・ Refractory concrete:

§ Thickness: ≥ 150 mm

§ Nature: 65% of Al203

・ Protect in coarse panel:

§ Thickness: ≥ 85 mm

Nature: Calcium



廣州新譜電子

2019年05月22日 業績與案例 361 views

新譜電子

潔凈棚,電加熱

項目名稱:New Optics潔凈棚,電加熱

項目簡介:潔凈棚,電加熱設計生產安裝






  新譜(廣州)電子有限公司是由韓國NEW OPTICS LTD 總部於2007年投資成立,公司位於廣州市高新技術產業開發區——科學城,公司註冊資金為1200萬美元,總投資額為6000萬美元。主要生產LCD組成部件中的“背光源”,並直接配套供給LG集團(樂金顯示(廣州)有限公司)

更多內容 網址: www.ecolead.cn 電話: 025-57138032