Archive: October 9, 2022

Pyrolytic Dual Chamber Incinerator Small Size : Burning Price : 30-45 kg/hr ; Optimum Load Capability : 400 kg

Items/Model

TS50( PLC)

Picture

Principle

Strong Waste Incineration

Burn Price

30-45 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

560L

Inner Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V

Oil Intake (kg/hour)

Typical 13.3

Gas Consumption (m3/hour)

***

Temperature Display

Digital Show

Temperature Level Defense

Yes

Oil Storage Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature Level

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Exterior Measurements

230x130x155cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Tool Dimension : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Incinerator

Items/Model

TS100( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

60-80 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1200L

Interior Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Setting

Manual

Voltage

220V

Oil Consumption (kg/hour)

Typical 20.4

Gas Intake (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Level Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Pet crematorium Around 200KG/day

Animal Crematory Incinerator



Capacity: Average 80kgs per feeding

Thing

Specification

Model

A900

Internal Dimensions

120 x 90 x 85 CM

Suit for Animal

Cat – yes

Dog – yes

Pig – small

Cow – no

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters

*(Update to Stainless Steel, free cost)

Italy oil/gas burner: 03 sets

Oil Tank (if Petroleum fuel): 500Liters

















Model

A900

Picture

Burning Rate

Average 30 kgs/hour

Feed Capacity

Average 80 kgs/feeding

Primary Combustion Chamber

900 Liters

Secondary Combustion Chamber

300 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.5 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 34 kg/hour

Gas Consumption (Natural Gas)

Average 41 m3/hour

Internal Dimensions

120 x 90 x 85 cm (primary chamber)

External Dimensions

200 x 160 x 310 cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if Petroleum fuel)

500 Liters

Door Opening

60 x 80cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Combustion Chamber Material

Refractory Concrete Cement(No Brick)

Equipment Gross Weight

6000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98 percent

Waste Lower Calorific Power

3000Kcal



 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

fabricants de brûleurs

1. CHAMP D’APPLICATION Les travaux spécifiés dans l’accord comprendront certainement.
1. Fournir, placer et attribuer un appareil de chauffage comme indiqué dans les spécifications technologiques
2. Spécification d’adhésion à l’OSHA ainsi que d’autres exigences légales liées à la santé et au bien-être des membres du personnel tout au long de l’exécution des travaux couverts par cet appel d’offres.
3. Analyse et travaux de préparation ainsi que construction et construction d’un hangar à brûleur standard avec une salle de stockage des déchets (voir la conception)

4. Stipulation du traitement et aussi des guides d’entretien ainsi que des illustrations avec un calendrier et des directives d’entretien.

5. Réservoir de stockage de gazole – capacité en acier léger de 1500 litres

6. Formation sur site pour l’exploitation en plus de l’équipe de maintenance.

CRUCIAL
Les soumissionnaires qui ne se conforment pas totalement à ce besoin verront leur offre rejetée. BESOINS TECHNOLOGIQUES DU BRÛLEUR NÉCESSAIRE

2.1 Récapitulatif général

L’usine doit avoir 4 zones uniques qui montrent 3 principes de turbulence, de temps à la maison et également de rétention du niveau de température.
1. Plan d’ensemble de l’usine
2. Chambre d’alimentation / chargement
3. Chambre de combustion des clés
4. Épurateurs de particules
5. Épurateurs de gaz acides.
6. La cheminée / cheminée.
7. Capacité minimale de la chambre cruciale = 0,18 mètre cube
8. Prix en baisse (prix de l’incinération des déchets) = a au moins 20 kg par ressource humaine
9. Nécessité d’avoir une porte de remplissage à contrepoids pleine dimension permettant un accès très simple à la chambre principale pour le remplissage et l’élimination des cendres.
Fourniture, installation et désignation d’un brûleur dans les Hydros de l’Est [page Web 28

2.2 Alimentation et facturation supplémentaire
Une alimentation mécanique sanitaire contrôlée qui n’influence pas négativement le degré de température de l’air dans le tour ainsi que les deuxièmes chambres de l’appareil de chauffage doivent être utilisées.
2.3 Chambre de combustion des clés.

a) Cette chambre doit être équipée de brûleurs utilisant un gaz à faible teneur en soufre.
b) La chambre doit garantir un degré de température de sortie marginal de 850 degrés centigrades.

2.4 Chambre de combustion secondaire (après le brûleur)

a) Doit être équipé de systèmes de chauffage utilisant un gaz à faible teneur en soufre.
b) Assurance que la 2e alimentation en air est contrôlée.
c) Voir à lui le temps de séjour n’est pas beaucoup moins de deux secondes.
d) Garantir que le niveau de température du gaz mesuré par rapport à la paroi intérieure dans la chambre supplémentaire et également pas dans l’emplacement du feu n’est pas beaucoup moins de 1100 niveaux centigrades.
e) Assurez-vous que le matériau de la nappe d’oxygène déchargé des gaz émis n’est pas beaucoup moins de 11%.
f) L’assurance que les niveaux de température de combustion primaire et secondaire sont préservés jusqu’à ce que tous les déchets soient totalement enflammés.

2.5 Éliminateurs de particules

Un amant de fragments mécaniques doit être incorporé après la 2ème chambre de combustion pour éliminer les particules de substances toxiques entraînées dans le flux de gaz de combustion. Les agences de collecte de particules peuvent comprendre l’un quelconque des éléments conformes ou un mélange de ceux-ci:.
a) Séparateur cyclone.
b) précipitateurs électrostatiques.
c) Filtres en tissu.
2.6 Cheminée / pile

l) L’arbre de fumée doit avoir une altitude marginale de 10 mètres au-dessus du degré du sol en plus de dégager le sommet de la charpente d’au moins 3 mètres pour tous les toits. La topographie ainsi que l’élévation des structures voisines dans un rayon de 50 mètres doivent être prises en compte.
m) L’arbre de fumée doit certainement se présenter à l’automobiliste depuis la zone d’alimentation.
n) Le prix minimum de congé doit être de 10 mètres par seconde en plus d’au moins deux fois la vitesse du vent limite (vitesse d’efflux = vitesse du vent x 2) selon la valeur la plus élevée pour éviter le nettoyage des gaz sortants.
o) Le point de mesure des rejets sera certainement proposé.

2.7 Instrumentation

a) L’outil permettant de connaître la température intérieure du mur ainsi que le niveau de température du feu non chauffant doit être adressé à la fois aux chambres secondaires et aux chambres clés.
b) Une exigence supplémentaire de système d’alarme notable et distincte doit être montée pour signaler à l’opérateur lorsque le degré de température de la deuxième chambre chute pour indiquer ici la température demandée.
c) Un gaz monoxyde de carbone ainsi qu’un compteur / enregistreur d’oxygène supplémentaire doivent être fournis

d) Un densimètre / enregistreur de fumée doit être fourni.
e) Un appareil de mesure / enregistreur de particules puissant doit certainement être fourni.
f) Toute sorte de divers autres outils qui peuvent être considérés comme essentiels.

2.9 Province d’échappement

a) L’efficacité de combustion (CE) doit aller au minimum 99,00% où CE =% Co2 x 100 / [% DIOXYDE DE CARBONE + monoxyde de carbone] b) Le degré de température de la chambre principale sera certainement de 800 +/- 50 degrés centigrades. c) Le temps supplémentaire de la chambre à gaz dans la chambre doit être d’au moins 1 seconde à 1050 +/- 50 degrés centigrades avec 3% d’oxygène dans le gaz de pile.
d) L’opacité de la demande de fumée ne doit pas dépasser 20% vue à 50 mètres à l’œil nu.
e) Tous les rejets dans l’air en dehors de la vapeur ou de la vapeur d’eau doivent être sans odeur et sans brouillard, fumée et aussi grains.
f) Une efficacité de dévastation et d’élimination (DRE) de 99,99% pour chaque élément dangereux naturel primaire (POHC) dans l’alimentation des déchets où DRE [(Success – – – – Wout) / Win] x 100 où Success = prix de masse de l’alimentation du POHC dans le flux de déchets alimenté au brûleur ainsi que Wout = prix d’échappement massique du POHC dans la pile avant le lancement dans l’atmosphère.
g) La concentration typique de dioxine et de furane dans les gaz d’échappement ne doit pas dépasser 80 mg / m3 de dioxines et furanes globaux si elle est mesurée sur une durée de 6 à 16 heures.

– – – – Un guide de veille technologique est livré avec les appareils avec toutes les descriptions des pannes en plus des résolutions.
Capacité / île: 4000 kg / jour; 25000 kg / jour; 31000 kg / jour; 48000 kg / jour

Température de combustion – – plus de 12000C

Deux chambres – – minime

S’use – – la dioxine ainsi que d’autres métaux importants – – beaucoup mieux après cette procédure de Kyoto

Décharge – – système de suivi

Élimination des déchets – – directement du chemin des déchets à l’incinérateur

Waste Incinerators From Chinawaste, Incinerators

Product Description

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 
Incinerator fuel: Gas incinerator, oil incinerator 
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. "Dioxins" refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. China ecological incinerator manufacturers, China horse cremation incinerators, China incenarators for sale, China incinerators company, China incinertor rotary model yd 500, Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc. 

So, why we still use incinerator? 
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control. 
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two reason but not only above, we still use incinerators. 

How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don't have gas supply system. 
And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc. 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

歌爾聲學潔凈棚

2019年05月20日 業績與案例 348 views

項目簡介:歌爾聲學地處齊魯大地,是中國電聲行業領導企業,也是全球微電聲領域的專業廠商。

作為一家從事聲電器件,光電器件等精密類產品的生產研發的企業,歌爾股份的車間對於車間通風性能,潔凈性能等方面有極為嚴苛的需求。此次選購的鋁型材潔凈棚,在鋁材厚度、隔斷材質、透光度、抗靜電性能等方面都按照最高等級配置。

更多內容 網址: www.ecolead.cn 電話: 025-57138032

Plus Size Burning Price : 150-200 kg/hr Solid Waste Devices Primary and Second Combustion Chamber Burner

Items/Model

TS500( PLC)

Picture

Concept

Waste Incineration Treatment

Burn Price

150-200 kg/hour

Control Setting

PLC( Programmable Logic Controller Burner)

Combustion Chamber

2700L

Interior Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Oil Intake (kg/hour)

Ordinary 28

Gas Usage (m3/hour)

***

Temperature Display

Digital Display

Temperature Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

15000kg

Outside Measurements

400x210x300cm( without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Medical Waste Incinerators

Medical Waste Incinerator

Manual load twin room incinerator for medical waste to burn 50kg/hr on constant operation, with Main temperature in the region of 800degC minimum and 1200degC or longer at the Secondary room, complete with charging door, Ash door, Air and see ports, auxiliary air system with adjustable dampers, burners and burner control system and ignition device, the entire to meet NEMA requirements and other international standards.

 

MEDICAL WASTE INCINERATORS

Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Gal annealed) by Hot-Dip Process FM GLOBAL (FM)
SECTION 11 82 21 Page 6
High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardened
The incinerator will be of the controlled atmosphere kind, designed for (6-8) hour-day surgeries and rated at 75 mph.

MEDICAL WASTE INCINERATORS for furnishing, installing, adjusting, and testing automatically controlled air medical waste incinerators having a capability to burn 75 Kg/hour waste substances of biological and pathological nature.

The process of incineration provides the advantage of volume reduction as well as the ability to dispose of familiar waste and sharps. On site incinerators provide a quick and effortless way of disposing medical waste. This is the most commonly accepted and feasible way of managing highly infectious waste.
9Platform and portholes created to USEPA standards to ease stack testing.

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN WELDING SOCIETY (AWS)
3Continuous loading with hydraulic ram feeder o Burners and fuel system
MANUFACTURERS STANDARDIZATION SOCIETY OF THE VALVE AND FITTINGS INDUSTRY (MSS)
8Incinerator building, including fire safety equipment
ASTM A53/A53M (2010) Standard Specification for Pipe,
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
U.S. GENERAL SERVICES ADMINISTRATION (GSA) UNDERWRITERS LABORATORIES (UL)

Установка для сжигания бытовых отходов

Базовая информация.

Номер модели: установки для сжигания медицинских отходов и крематорий для животных
Экспортные рынки: глобальный

описание продукта

1. Clover Medical Limited сохраняет все права на исправление / обновление информации о продукте на веб-сайте. Технические характеристики могут быть изменены без предварительного уведомления.

2. Мы принимаем коммерческие условия: условия FOB / C и F / CIF, морским путем / поездом, в полном контейнере или навалочные грузы. 1. FOB (Free on Board), цена покинуть порт Китая. 2. C&F (Стоимость и фрахт), цена FOB и стоимость фрахта. 3. CIF (Стоимость, страхование и фрахт), цена FOB, страховой сбор и стоимость фрахта.

3. Срок оплаты:
По морю: 50% депозит T / T (банковский перевод) заранее и 50% баланс T / T до дня доставки.
Поездом: 100% T / T заранее.

4. Транспортный документ и упаковка: Как правило, мы поставляем (1) транспортную накладную (накладную), какой образец… (2) коммерческий счет-фактуру, (3) ТОЛЬКО упаковочный лист.
Если какие-либо дополнительные документы / сертификаты и печать / слова на этикетке на упаковочном материале или документах, запрашиваемых импортером или местной таможней, что бы ни происходило в Китае или за границей, должны проинформировать продавца заранее и взимать плату как фактическую стоимость. Например, сертификат фумигации, посольский сертификат, осмотр BV / SGS…, сертификат оригинала (C / O), форма A и т. Д. Покупатель должен проинформировать продавца заранее и оплатить эти расходы. Продавец сохраняет за собой все права отложить / отменить отправку установки для сжигания отходов в Китай, двухкамерной установки для сжигания отходов, установки для сжигания отходов производства Clover, производителя установки для сжигания отходов, производителей установок для сжигания отходов, установки для сжигания сточных вод, а также запросить потерю стоимости, вызвавшую этот инцидент. Если местная таможня импортера арестует / потребует штраф или другая ситуация вызвана ошибкой покупателя, Clover Medical сохраняет за собой право потребовать компенсацию / судебный процесс. Спасибо за сотрудничество.

5. Срок изготовления обычно составляет 3-6 недель, в зависимости от продуктов и количества.

7. Гарантия: Один год на оборудование. Мы поставляем запасные части для технического обслуживания бесплатно в течение первого года, а стоимость доставки ложится на покупателя.

8. Страхование: нести все риски потери или повреждения товаров с момента их пересечения с поручнями судна в названном порту отгрузки. Предлагаем применять страхование всех рисков по каждому договору. Когда покупатель забирает товар на местном сайте, необходимо внимательно осмотреть. Если в рамках страхового полиса произошел какой-либо ущерб, покупатель должен немедленно сообщить об этом страховой компании и Clover Medical Limited. Окажем необходимую помощь.

Предметы / Модель TS10 (ПЛК) TS20 (ПЛК) TS30 (ПЛК) TS50 (ПЛК) TS100 (ПЛК)
Скорость сжигания 10 кг / час 20 кг / час 30 кг / час 50 кг / час 100 кг / час
Емкость подачи 20кг 40кг 60кг 100кг 200 кг
Режим управления ПЛК ПЛК ПЛК ПЛК ПЛК
Камера сгорания 100л 210л 330 л 560 л 1200L
Внутренние размеры 50x50x40 см 65x65x50 см 75x75x60 см 100x80x70 см 120x100x100 см
Вторичная камера 50 л 110л 180л 280L 600 л
Камера дымового фильтра да да да да да
Режим подачи Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации
Напряжение 220В 220В 220В 220В 220В
Мощность 0,5 кВт 0,5 кВт 0,5 кВт 0,7 кВт 0,7 кВт
Расход масла (кг / час) 5,4–12,6 7,8–16,3 10,2–20 12.1–24 14–28
Расход газа (м3 / час) 6,2–11,4 8–15,7 9,8–20 9,9–26,1 10–32,2
Монитор температуры да да да да да
Температурная защита да да да да да
Масляный бак 100л 100л 100л 100л 200л
Дверца подачи 30×30 см 45×40см 55×50см 70×55см 80×60 см
Камин 3 метра 3 метра 5 метров 5 метров 10 метров
Тип дымохода Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь
Время проживания 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек.
Вес брутто 1500 кг 2200кг 3000кг 4500кг 6000кг
Внешние размеры 140x90x120 см 160x110x130 см 175x120x140 см 230x130x155 см 260x150x180 см