Pre-assembled containerized kind Burner

Pre-assembled, containerized type Incinerator

Design

CA100

Picture

Waste Treatment

Medical Waste Incineration Treatment

Feed Capacity

Average 100-200 kgs per feed

Burning Price

Ordinary 100-120 kgs per hr

Burning Time per Feed

Standard 1-2 hr

Control Mode

PLC( Programmable Reasoning Controller Burner)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Heater

Feed Setting

Handbook

Temperature Level Screen

Digital Display

Gas usage (Oil)

Typical 20.4 Kgs/Hour

Inner Measurements

100x80x70cm (Primary Burning Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste burning chamber

560Liters

Blog Post Burning Chamber

280Liters

Oil Storage Tank Capability

200 Litres

Door Opening

70 x 50cm

Chimney

5.0 M

Gross Weight

4500kgs

Chamber Material

Firebrick, Refractory Concrete

Max. Warm Value

166,000 Kcal/Hr.

Procedure Technical Specifications

Solid Chamber temperature

8000C -10000 C

Gas Chamber temperature level

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning performance

> 98%

Waste Lower Calorific Power

3000Kcal

Pre-assembled, containerized type do not included chimney installation,containerized  mobile type.
 Burning rate: 100 – 120kg / hour
 Minimum operating temperature: 800-1000 degree
  (Primary combustion)
Maximum operating temperature: 1000-1200 degree  (afterburner chamber)
Secondary Burning capacity: Compulsory.
Density insulation: 50mm high
Refractory casting: minimum 114mm
Heavy duty refracting lining to withstand 1750 degree
Average burn out time: maximum 1-2 hours
Fuel type: fuel oil (diesel)
Fuel consumption in L/hr: average 20.4 liter/Hr.
Residency time in secondary chamber: 2 secs.
Residue ash post 100kg Max 3.8 kg
Installation period Maximum 7days.
State: Anambra Sites:
General Hospital Onitsha
General Hospital Enugwu Ukwu
General Hospital Ekwulobia
Orumba General Hospital
II. State: Benue Sites:
North East Senatorial zonal waste collection site (zone A): EPI Office Katsina-Ala LGA
North West Senatorial zonal waste collection site (zone B): EPI Office Gboko LGA
Benue South zonal waste collection site (zone C): EPI Office Otukpo LGA
Benue State Capital: Central Medical Store, Makurdi
III. State: Kogi Sites:
University Teaching Hospital, Anyigba, Dekina LGA
General Hospital Obangede, Okehi LGA
General Hospital Mopa-Muro LGA
IV. State: Ebonyi Sites:
General Hospital Ezzango, Ebonyi North Zone
 General Hospital Onueke, Ebonyi Central Zone
External L= 3235, W=1150, 1950/3825,Internal L=1600, W=675, H=700;Chamber volume(m3)=0.76;Weight(appox tonne)=3.6,max load capacity (kg) 300, Nominal burn rate uk(kg/hr.)=<50,Thermal capacity(kw) =390, power supply 50/60Hz =220-250v,Door Apertune = 67×550; Hot earth principle = double pass, Fuel type Diesel; Control Panel = Al, Insulation board 25 mm super wool, insulation fire brick =grade E23, Fire brick(Alumina) =42.5%
incinerator capable of a load of upto 50kg/hr.
Twin chamber and should be diesel fuel fired complete with automatic temperature controller upto 900` Celsius.
incinerator (2 equipment) 500kg/hr for face mask disposables.
Automatic smoke free incinerator of capacity 150-200kg/hr for industry. The waste cab be comprises of following types:-
         i.            Wet waste.
       ii.            Plastic wrappers,
      iii.            Solid waste(wood, papers, cartoon box and others).
V. State: Imo Sites:
 Nwabosi Health Center, Nwabosi settlement Isiekenesi ward 2, Ideato South LGA
 Comprehensive Health center, Umuezeala Owerre ward, Ehime Mbano LGA
 Nnenasa Health Center, Umugba settlement, Umueze ward Njaba LGA
General Hospital Owerri Umuguma settlement, New Owerri ward 1
VI. State: Oyo Sites:
State cold store Jericho, South-West LGA, Ibadan
Oyo East Local Government Secretariat, Oyo East LGA
Adebayo Alata Primary Health Care Center (PHC), Ogbomosho South LGA
Itesiwaju NPI Office, Out Itesiwaju LGA
Saki West NPI Office, Saki West LGA
Ibarapa Central NPI Office, Ibarapa Central LGA
VII. State: Kwara Sites:
Ifelodun LGA
Ilorin West LGA
VIII. State: Enugu Sites:
Nsukka District Hospital, Nsukka Town, Nsukka LGA
Agbani District Hospital, Agbani Town, Nkanu West LGA
Udi District Hospital, Udi Town, Udi LGA
IX. State: Enugu MSites:
Odukpani LGA
Obubra LGA
Boki LGA

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-30

自動卷繞式過濾器的濾料多長時間更換?

2019年05月22日 行業動態 456 views

南京伊希歐的自動卷繞式過濾器的濾料多長時間更換?

 自動卷繞式過濾器的濾料多長時間更換?

1、因地區的不同而不同。北方污染較南方嚴重,因為北方植被綠化較少,污染嚴重則濾料更換的速度就會快一些。如石家莊冬季,一周左右濾料就會卷繞一次,3米高的捲簾器15米長的濾棉,一個多月就要換整卷;而廣州,1個月方才卷繞一次,整卷能用大半年。差別很大。

 2、因季節不同而不同。冬季比夏季污染嚴重,夏季因為降水較多,且空氣中水汽含量較冬季多,大量的灰塵被送回到地面,空氣質量好些。而且,夏季不像冬季那樣多寒冷乾燥的季風,揚塵較少。所以,夏季濾料能用的更久一點。

 3、局部地區的環境狀況也會影響。如當地有大型的煤炭冶金企業,或長期的土建項目,都會造成PM2.5值偏大,空氣中的主要污染物——灰塵增多。這樣,相鄰兩地,濾棉所用時間自然會有差異。

 4、另外,濾料更換的時間與壓差開關設定的數值也有關係。我司出廠設定值為100~150Pa,100Pa的濾棉用的時間比150Pa的短些,這點要根據業主的需求調整。

總是所述,業務人員經常遇到的捲簾空氣過濾器濾料多久換一次的問題,因客戶而異、因地區而異、因使用環境而已,不能一概而論,如需要了解詳細自動捲簾過濾器濾料相關知識,請聯繫南京伊希歐的銷售人員。

更多內容 網址: www.ecolead.cn 電話: 025-57138032

Pet Crematory with Movable system & & Automobile. Door & Independent Position

Incinerator Model A1500, Introduction

This version is big-scale pet cremation tools for enormous creatures.

Construction is dual/double combustion chamber with 03 units oil/gas burner, 
batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). 
Primary & Secondary combustion chambers and included mix-combustion chamber, 
smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load on 
the bottom of chamber. Incinerator panel control suit for local operation.

Model

A1500

Burning Rate

Regular 50 kgs/hour

Feed Ability

Ordinary 150 kgs

Main Combustion Chamber

1500 Liters

Added Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Guide

Voltage

220V/380V

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Burner

Italy Original

Oil Intake (Diesel Oil)

Typical 34 kg/hour

Gas Intake (Gas)

Regular 41 m3n/hour

Inner Measurements

150 x 100 x 96cm (primary chamber)

Outside Measurements

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Container Ability( if oil gas)

300 Litres

Door Opening

59 x 81cm

Smokeshaft Length

10.0 Meters

Smokeshaft Type

Stainless-steel

Tools Gross Weight

7500 kgs

Operation Technical Specifications

Main Chamber Temperature

800 ℃–– -1000 ℃

Secondary Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98 percent

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Small Mobile Veterinary Incinerator 20 Kg Hour Burn Rate

Basic Info.

Model NO.:waste incinerator china suppliers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can use in this equipment? 
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard 
A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity 
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. Mobile incinerator, small animal incinerator, small scale incinerators, , chinese incinerator manufacturers, clover incinerater, hospital waste incinerator, When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. 
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing 
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. 

Q: Combustion Temperature 
A: The first combustion chamber: 800-1000 centi degree. 
The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode 
A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items Specification
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Infectious Waste Incinerator

Product Description

Principle of This Incinerator Gear is incineration/combustion/burn.

The principal body is 1 combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is outside gas or oil burner. The burner can be running until waste burnout but for many waste like vinyl, paper (sometime, combine coal with waste before feeding)they can combustion itself following Ignition. During combustion, burner includes a fan little incinerator cost, little incinerator laboratory, small incinerator manufacturer, incinerator medical waste, little incinerator price in china, little incinerator primary chamber secondary, itself to get Oxygen supply and additionally shield burner avoid heat damage from combustion room. And, there a outside fan blow air into combustion chamber. The Exhaust gas blow out following combustion. 

Contemplating Environmental Protection demands and principles, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even when third combustion room. The secondary burner burn off the Exhaust gas from primary combustion chamber, this technologies make sure sufficient combustion, few black smoke and smell. 

The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous substance and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation. 

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

In some Developed countries, some fresh waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Tiny Waste Burner, 10kgs per hour capability, PLC control Model TS10( PLC).

Small Waste Incinerator, 10kgs per hour capacity, PLC control

Items/Model

TS10( PLC)

Picture

Burn Price

Average 10 kg/hour

Feed Capability

Average 20kg/feeding

Control Setting

Programmable Logic Controller( PLC) Panel

Burning Chamber

100L

Internal Dimensions

50x50x40cm

Second Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Guidebook

Voltage

220V

Power

0.5 Kw

Oil Intake (kg/hour)

standard 8.4 kg/hour

Gas Usage (m3/hour)

standard 10.1 m3/hour

Temperature Monitor

Yes

Temperature Protection

Yes

Oil Container

100L

Feed Door

30x30cm

Smokeshaft

5 Meter

Chimney Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– 1000 ℃

second. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

1500kg

External Measurements

140x90x120cm


Small Incinerator for Erbil Iraq

HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-07-05

incinérateur pour petits animaux

  1. Emplacements et tailles de raccordement de tuyauterie et de cheminée.
  1. Données techniques, y compris la température nominale et la disposition du réfractaire et de l’isolation.
  1. Poids de l’unité et diagramme de chargement de la fondation. Preuve que l’entrepreneur a coordonné le soutien

exigences avec la conception des fondations.

  1. Ancrage recommandé à la fondation. Les exigences sismiques s’appliquent. Soumettez les calculs par un ingénieur professionnel.
  1. Températures de surface externes prévues.
  2. Rapport de test certifié sur les performances de types de déchets de combustion unitaires similaires dont la composition est similaire à

Article, CONDITIONS DU PROJET, cette spécification:

  1. Durée de combustion globale et réduction de poids.
  2. Quantité et composition des déchets par lot.
  3. Émissions dans toutes les catégories spécifiées dans la PARTIE 2.
  4. Utilisation de carburant auxiliaire.
  1. Données de catalogue sur les brûleurs, les atténuateurs de bruit, les trains de carburant, les moteurs.
  1. Besoins en carburant: débit, pression à l’entrée du train de carburant.
  1. Puissance à pleine charge, efficacité et facteur de puissance de tous les moteurs supérieurs à un cheval-vapeur.
  1. Exigences de service électrique pour tous les moteurs et commandes.
  1. Niveau sonore prévu de tous les systèmes.
  1. Diagrammes schématiques des systèmes de contrôle. Coupes de catalogue sur les composants des systèmes de contrôle et d’instruments.

Description du fonctionnement du système de contrôle.

  1. Disposition et emplacement des panneaux de commande.
  1. Système de pile:
  1. Dessins montrant la disposition et les dimensions du système.
  1. Poids des sous-ensembles.
  1. Conception, construction, limitations de pression et de température de l’ensemble du système, y compris les joints de dilatation et

amortisseurs.

Regular 10kgs per hr burner for small Health Care facility

This equipment quality structural for kinds of site, like hospital, environmental department, 
animal cremation agencies, etc. 
HICLOVER Incinerator supply updated models with dual combustion chamber, 
mix-combustion chamber and smoke filter 
chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Devices Technical Specifications

Model

YD-10C

Photo

Feed Capacity

Average 40 kgs per feed

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

3.0 -5.0 hrs

Voltage

220V

Power

0.50 Kw

Gas

Natural Gas or Diesel oil

Heater

Italy Heater

Feed Mode

Guidebook

Gas Use (Oil)

4.4-9.4 Kgs/Hour

Fuel intake (Gas)

5.3-11.2 m3/Hour

External Dimensions

170 x 140 x 160cm (mainbody)

Interior Measurements

55 x 55 x 65cm( Key Chamber)

Waste burning chamber

200Liters

Article Combustion Chamber

140Liters

Oil Container Capacity

50 Litres

Door Opening

38 x 48cm

Chimney

5.0 M

Gross Weight

1800kgs

Chamber Product

Refractory Concrete

Max.

94,000 Kcal/Hr.

Operation Technical Specs

Solid Chamber temperature level

8000C -10000 C

Gas Chamber temperature

Chamber Anti-Rate

10000C -12000 C

Residency time

13500C

2.0 Sec.

Burning efficiency

> 98 percent

Waste Lower Calorific Power

3000Kcal


































 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Large Scale Municipal Waste Incinerator

Basic Info.

Type:Incinerator
Export Markets:Global

Product Description

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from biology waste 2b waste burner, biomedical incinerator for sale, biomedical waste china, biomedical waste incinerator manufacturers in china, brainwaves systems middle east, 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 
Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

30 kgs clinical waste incinerators for covid19 waste

Q: what is kind of waste can use in this devices?

A: This equipment for clinical waste, pet dog animal, Municipal waste, real-time waste. Ban any kind of explosive and radiation product, fluid waste as well as gas waste.

Items/Model

TS30( PLC)

Shed Rate

Average 30 kg/hour

Feed Ability

Average 60kg per feeding

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

330L

Interior Measurements

75x75x60cm

Second Chamber

180L

Smoke Filter Chamber

Yes

Feed Setting

Handbook Feeding

Voltage

220V

Power

0.5 Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Usage (N.G, m3n/Hour)

Typical 16

Gas Usage (L.P.G, m3n/Hour)

Ordinary 11.7

Temperature Screen

Four Digital Present

Temperature Protection

Yes

Oil Storage Tank

200L

Feed Door

55x50cm

Smokeshaft

5Meter

Smokeshaft Type

Stainless Steel

1st. Chamber Temperature Level

800 ℃–– 1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

3000kg

Exterior Dimensions

175x120x140cm


HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



 

2020-07-06