Tag: wasteincinerators

small scale medical incinerator

The burners shall comply with the requirements of BS 799 or DIN Standards. Each shall be the packed type and

incorporate automatic stop/start programmed timer control, flame failure equipment and ignition failure equipment to

close off the fuel supply in the event of malfunction.

 

  1. Each burner shall be designed and mounted for ease of access and so that they may be fully maintained from

outside the combustion chamber. The burners shall be mounted so that waste cannot block the flame ports.

SL No   Description   Fill up the bidder

Lot-A Specification

1     Hydroclave for Medical waste Treatment Plant

 

General Requirements

  • The processor must be approved to sterilize & treat the following types of medical waste:

—   Liquids: Blood, body fluids etc.

—   Blood bags & tubing, gloves, Gowns, drapes, etc.

—   Contaminated packaging: bandage etc

—   Sharps & Sharp containers

—   Disposable instruments

—   Glass products

— Human and animal tissue (surgical and pathologic)- Based upon MWM regulations.

— Cultures, stocks and glassware

 

*  The processor must comply with a documented efficacy level of 6 log10 reduction in spore survival (99,9999%) of the

Bacillus Stearothermophilus

* The processor should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of

the waste

* The processor must have ZERO harmful emission level and meet or exceed all standards required by the EU.

 

The whole waste treatment system should be offered as a complete unit consisting of following equipment and

ancillaries-

(A) The sterilization processing unit

(B) Steam Boiler

(C) Tub washer

(D) Heavy duty external shredder

(E) Conveyer belt — based on Manufacturer’s Recommendations

(F) Bin Lift/Tipper

(G) Spore tester

 

 

(A) Features and Specifications of the Sterilization Processor unit:

Technical specification of the processor.

*  Steam autoclave in combination with a heavy duty Fragmenting System inside the vessel/ chamber

*  The vessel must be of Double Chamber

* Capacity (kg/load): minimum 2001cg/batch/cycle

*  Volume of 140-190 liters of bulk per cycle

*  Average Cycle time: 60 minutes

*  Operating temperature : 121°C to 135°C

*  Operating pressure: 1.1 Bar to 2.4 Bar

* Sterilization time : approx. 30 minutes at 121°C/1.1 Bar or approx 15 minutes at 132°C/2.5 Bar to achieve 6log10

sterility

* Fragmentation inside the chamber: Heavy duty with maximum size of final product <20 cm.

*  Volume reduction of the waste after processing : by 60-80% through complete waste dehydration including liquid

content of the waste

*  All actions after loading for sterilization, fragmentation of product is to be occurred in the same chamber/vessel

*  Pre or Post-air evacuation should not be necessary or used

*  Exhaust air quality: Does not require any venting for odor control

* Operating System: Fully automated with manual over-ride. (On board PLC capable of generating written report with

cycle time, cumulated time at > 121°C

* The option should be there for Internet connectivity by phone, cable or

* Boiler: should not require pre-heated water

* Electrical requirements: 220Vac, 1ph or 400vac 3ph to suit customer needs

* Noise level at full operation: < 80 dB

Working Principle of the processor:

*  The processor should utilize steam technology in conjunction With a mechanical fragmentor (grinder) to sterilize

medical waste, thereby  making the  residual waste safe for disposal in landfills.

*  The sterilization vessel MUST be a double walled (jacketed) cylindrical vessel

* Pre-shredding of infectious waste must not be accepted, the fragmentation must occur safety inside the scaled vessel

continuously.

* The sterilization vessel/chamber must be fitted with a motor driven shaft to which a heavy duty grinder(fragmenting

arm)  is attached inside the vessel to produce all unrecognizable size of the waste product.

* The Fragmenting are must rotate to agitate waste continuously throughout the heating and sterilization cycle to

ensure that the fragmented q agitated wastes (including sharps and liquids) are exposed evenly to sterilization

temperature and pressure.

* Steam heat should be applied to the jacket only, while the agitated waste absorbs the heat from the jacket and makes

its own steam from its moisture content.

* Should not need for special autoclave bags — simple bag or box should be workable

* MUST not need for hi c-treatment of the waste.

* Liquids and gases MUST remain locked inside the vessel until sterilization is complete – nothing should be vacuumed

or pumped out in its infected state.

* Jacket steals heat to dehydrate the waste completely regardless of its original water content.

* All the hot condensate from the jacket is recycled, making the processor very economical to operate

100-150kgs Burning cost with Second burning to be usage in the health center


Oil tank with 2000Liters capacity

Items/Model

TS150( PLC)

Image

Principle

Waste Incineration Therapy

Burn Rate

Requirement 100-150 kg/hour

Feed Ability

Standard 750kg/feeding

Control Setting

PLC( Programmable Thinking Controller Burner)

Text Steel

8mm thickness

Chamber Product

High Alumina Fire Brick Wall Surface, 1750 ℃ Rate

Paint for outside face

800 ° C Rate

Combustion Chamber

1570L

Interior Measurements

150x100x105cm

Added Chamber

750L

Smoke Filter Chamber

Yes

Feed Establishing

Guidebook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Intake (Liter/hour)

Normal 14( D.O)

Gas Consumption (m3/hour)

***

Temperature Level Show

Digital Present

Temperature Protection

Yes

Oil Storage Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Degree

800 ℃–– – – -1000 ℃

second. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Outside Measurements

300x160x280cm( without smokeshaft)


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


pet incinerator

The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual

display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance.

Capacity of destruction in weight shall be 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories,

institutes, etc…

Design Specification : Types A, B, C, D, and E of medical waste

Supply, installation & testing DUCTED SPLIT UNITS at waste store with sufficient capacity to maintain the internal

temperature at 14 degrees Celsius in summers and winters

Containerized Mobile Heater CA100


Incinerator Variation CA100, Summary

100Kg/Hour Burning price with Secondary burning Capability

This design is tiny medical waste incineration gadgets. Building and building is dual/double

combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed 
chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke 
filter chamber with firebrick and  refractory concrete chamber. Batch load on the bottom of 
chamber. Incinerator panel control suit for local operation.

Version

CA100

Waste Treatment

Medical Waste Incineration Treatment

Feed Ability

Normal 100-200 kgs per feed

Burning Cost

Typical 100-120 kgs per human resources

Burning Time per Feed

Standard 1-2 hr

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Gas

Diesel oil

Burner

Italy Heating System

Feed Setup

Manual

Temperature Screen

Digital Display

Fuel consumption (Oil)

Ordinary 20.4 Kgs/Hour

Inner Dimensions

100x80x70cm (Secret Burning Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste melting chamber

560Liters

Post Combustion Chamber

280Liters

Oil Container Capability

200 Liters

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max. Heat Worth

166,000 Kcal/Hr.

Procedure Technical Specifications

Solid Chamber temperature level

8000C -10000 C

Concentration camp temperature degree

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

> 98%

Waste Lower Calorific Power

3000Kcal

Pre-assembled, containerized type,do not included chimney installation.Burning rate: 100 – 120kg / hour.
Minimum operating temperature 800-1000 degree.Maximum operating temperature:1000-1200 degree.
Secondary Burning capacity.Density insulation.Refractory casting.Heavy duty refracting lining to 
withstand 1750 degree.Fuel type: fuel oil (diesel).


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


50 KG/HR BIOMEDICAL BURNER


Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour

 Oil tank

smoke filter chamber

Items/Model

TS100( PLC)

Image

Principle

Waste Incineration Therapy

Burn Price

Average 50-100 kg/hour

Feed Capability

Average 200kg/feeding

Control Establishing

PLC( Programmable Thinking Controller Incinerator)

Burning Chamber

1000L

Internal Measurements

120x100x90cm

2nd Chamber

540L

Smoke Filter Chamber

Optional

Feed Setting

Handbook

Voltage

220V

Power

3.0 Kw

Oil Usage (kg/hour)

Typical 20.4

Gas Usage (m3/hour)

***

Temperature Level Display

Digital Existing

Temperature Protection

Yes

Oil Storage Space Tank

1800L

Feed Door

80x60cm

Smokeshaft

6Meter

Chimney Kind

Stainless-steel

1st.

Gross Weight

7000kg

External Measurements

260x150x180cm( Key Body)

Gross Weight

7000kg

External Measurements

260x150x180cm( Main Body)


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


incinerator smoke filter

All particles of the waste should achieve a high level of sterilization and not just “disinfection” due to the

continuous agitations

Description of the Treatment Cycle of the processor

  1. i) Loading

* The waste has to be loaded by dropping bagged and or boxed waste into the open loading door on the vessel.

* The loading door should be mounted at an angle on time top side, of the vessel with suitably sized to accommodate the

infectious wastes for which it is intended

* Over-loading or loading too tightly should not be an issue with this process, and hence no need of the special

operator skill.

 

  1. ii) Heat-up and fragmentation

* After loading, the vessel door is to be closed, and the outer jacket of the vessel is to be automatically filled with

high temperature steam, which should act as the main heating medium for heating the waste.

* During this heating cycle, the shall and mixing arms should rotate continuously, causing the waste to be fragmented

and continuously tumbled against the hot vessel walls.

* At this point, the waste is broken up into small fragments, and all material heats up rapidly, being evenly and

thoroughly exposed to the hot inner surfaces. The moisture content of the Waste will turn in to steam, and the vessel

will start to pressurize.

* Initially, no steam will be injected into the waste. If there is not enough moisture in the waste to pressurize

the vessel, a small amount of steam is to be automatically added until the desired pressure is reached.

* At the end of this period, the correct sterilization temperature and pressure should be reached, and the

sterilization period should start.

 

iii) Sterilization period

* The amount of steam fed to the outer jacket is to be regulated to maintain the desired temperature & pressure of the

inner vessel,

* The mixing arms (grinder) MUST continue to rotate throughout this cycle to ensure even sterilization pressure and

temperature for all wastes.

* The treatment time should be either15 minutes at 132° C OR 30 minutes at 121° C to achieve level 6log10

sterilization.

* The intense subjugation of the waste to high temperature and pressure moisture in a dynamic environment should also

cause the waste to hydrolyze that is a rapid decomposition of organic material.

 

  1. iv) De-pressurization:

* After the treatment time, the steam to the jacket should remain on, and the internal vessel is to be vented through a

condenser, and de-pressurized. Thus, the waste loses its water content through a combination of heat input from the

jacket and flashing of water due to depressurization.

 

  1. v) Dc-hydration

* Further dehydration is to be achieved by maintaining heat input and mixing – almost total dryness should be achieved.

 

  1. vi) Unloading

* Finally, steam to the jacket should shut off, the unloading door is to be opened

* Then the shaft and mixing arms are reversed to act as unloading mechanism and should scoop the waste fragments out of

the unloading door, onto a conveyor belt or directly into a waste container.

* The vessel should now be ready for another treatment cycle, having retained most of its heat for the treatment of the

next batch.

Waste Incineration Therapy Incinerators Avg. 100kgs per hour


HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc.

Items/Model

TS100( PLC)

Image

Principle

Waste Incineration Therapy

Burn Cost

Criterion 100 kg/hour

Feed Ability

Criterion 200kg/feeding

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

1200L

Inside Measurements

120x100x100cm

Extra Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Establishing

Handbook

Voltage

220V

Power

0.7 Kw

Oil Consumption (kg/hour)

normal 20.4

Gas Use (m3/hour)

average 24.5

Temperature Level Monitor

Digital Program

Temperature Level Defense

Yes

Oil Storage Space Container

200L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Kind

Stainless-steel

1st.

Gross Weight

6000kg

Outside Dimensions

260x150x180cm

Gross Weight

6000kg

External Measurements

260x150x180cm



 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


Tool Range Solid Waste Burner


Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…

Items/Model

TS150( PLC)

Principle

Waste Incineration Treatment

Shed Rate

Average 150 kg/hour

*( 50/100/200kgs/ human resources optional)

Feed Capacity

Ordinary 750kg/feeding

Control Setting

PLC( Programmable Logic Controller Burner)

Main Body Steel

8mm density

Chamber Item

High Alumina Fire Block Wall Surface, 1750 ℃ Price

Paint for outdoors face

800 ° C Price

Burning Chamber

1570L

Inside Capacities

150x100x105cm

Extra Chamber

750L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Intake (kg/hour)

Regular 20.4-28.0( D.O)

Gas Intake (m3/hour)

***

Temperature Display

Digital Show

Temperature Level Defense

Yes

Oil Container

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st.

Gross Weight

8500kg

Outside Dimensions

300x160x280cm( without smokeshaft)

Gross Weight

8500kg

Outside Measurements

300x160x280cm( without chimney)


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


Containerized Burner Design CA30 from HICLOVER


Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc.

Items/Model

CA30

Image

Shed Rate

Common 10 kg/hour

Feed Capability

Average 30kg per feeding

Control Establishing

PLC( Programmable Reasoning Controller Burner)

Combustion Chamber

330L

Internal Measurements

75x75x60cm

Additional Chamber

180L

Smoke Filter Chamber

Yes

Feed Establishing

Manual Feeding

Voltage

220V

Power

0.5 Kw

Oil Intake (kg/hour)

Ordinary 13.3

Gas Use (N.G, m3n/Hour)

Typical 16

Gas Usage (L.P.G, m3n/Hour)

Average 11.7

Temperature Level Monitor

Four Digital Program

Temperature Level Defense

Yes

Oil Container

100L or Even Much More( Optional)

Feed Door

55x50cm

Smokeshaft

5Meter or Also A Lot More( Optional)

Smokeshaft Kind

Stainless-steel

1st.

Gross Weight

4000kg( without container)

Exterior Dimensions

175x120x140cm

Gross Weight

4000kg( without container)

External Measurements

175x120x140cm



 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


animal incinerator china

Medical Waste Shredder

 

 Capacity: Should be 150 liters.

 Should be capable to shred up to 100 liters of the treated waste.

7

 The technology should be capable to treat hospital waste including sharps like needles,

lancets, scalpels and soft materials like bandages.

 Must render the waste to be unrecognizable.

Following accompanying documents must be supplied with the treatment system and shall

be available at the Site:

  1. Operation instructions (including process description.
  2. Loading and maintenance procedures.
  3. Short-form of operation and loading procedures.
  4. ASTM International (ASTM):

 

C401 91 (2005) Standard Classification of Alumina and Alumina-Silicate Castable Refractories

 

C612 04       Mineral Fiber Block and Board Thermal Insulation

 

  1. National Fire Protection Association (NFPA):

 

70 07     National Electrical Code

82 04     Incinerators and Waste and Linen Handling Systems and Equipment

 

  1. Underwriters Laboratories (UL):

 

50 07…  Enclosures for Electrical Equipment

 

 

PART 2 PRODUCT

 

2.1  INCINERATOR INSTALLATION

 

  1. The incinerator shall consist of a low temperature carbonizing changer (primary chamber) in which the waste

components are converted into gas by heat which is produced through incomplete combustion as the result of a deficiency

of air, and a gas reactor (thermal reactor) in which the gas is burned with a controlled excess of air.