hiclover waste burner extra parts

Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-03-06

2020-03-06
|
Version |
CA100 |
|
Photo |
|
|
Waste Therapy |
Medical Waste Incineration Therapy |
|
Feed Ability |
Ordinary 100-200 kgs per feed |
|
Burning Rate |
Typical 100-120 kgs per hr |
|
Burning Time per Feed |
Standard 1-2 hr |
|
Control Setting |
PLC( Programmable Logic Controller Incinerator) |
|
Voltage |
220V |
|
Power |
1.0 Kw |
|
Fuel |
Diesel oil |
|
Burner |
Italy Heater |
|
Feed Mode |
Handbook |
|
Temperature Monitor |
Digital Display |
|
Fuel intake (Oil) |
Typical 20.4 Kgs/Hour |
|
Interior Measurements |
100x80x70cm (Main Combustion Chamber) |
|
External Dimensions |
230 x 130 x 155cm (main body) |
|
Waste burning chamber |
560Liters |
|
Blog Post Burning Chamber |
280Liters |
|
Oil Tank Capacity |
200 Litres |
|
Door Opening |
70 x 50cm |
|
Chimney |
5.0 M |
|
Gross Weight |
4500kgs |
|
Chamber Product |
Firebrick, Refractory Concrete |
|
Max. Warm Worth |
166,000 Kcal/Hr. |
|
Procedure Technical Specs |
|
|
Solid Chamber temperature |
8000C -10000 C |
|
Concentration camp temperature |
10000C -12000 C |
|
Chamber Anti-Rate |
17500C |
|
Residency time |
2.0 Sec. |
|
Burning effectiveness |
> 98% |
|
Waste Lower Calorific Power |
3000Kcal |
2020-03-20
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, medical waste incinerators manufactures and suppliers, medical waste incinerators vs animal crematory, medical waste incinrators in china, medical waste italy, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
| Items/Model | A1500 | A2400 | A4000 | A5500 |
| Burning Rate *animal | 90 kgs/Hr. | 150 kgs/Hr. | 200 kgs/Hr. | 400 kgs/Hr. |
| Feed Capacity *animal | 120 kgs | 200 kgs | 300 kgs | 500 kgs |
| Equipment Weight | 7000 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
| Primary Chamber (Liters) | 1500 | 2400 | 4000 | 5500 |
| Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
| External Dimensions (cm) | 240x170x380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
| Internal Dimensions (cm) | 150x100x96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
| Oil Tank(Liters) | 500 | 500 | 500 | 500 |
| Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
| Chimney (M) | 10 | 10 | 14 | 14 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
| 1st. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| 2nd. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Items/Model
TS50( PLC)
Picture
Principle
Strong Waste Incineration
Burn Price
30-45 kg/hour
Control Mode
PLC( Programmable Reasoning Controller Burner)
Burning Chamber
560L
Inner Measurements
100x80x70cm
Secondary Chamber
280L
Smoke Filter Chamber
Yes
Feed Setting
Manual
Voltage
220V
Oil Intake (kg/hour)
Typical 13.3
Gas Consumption (m3/hour)
***
Temperature Display
Digital Show
Temperature Level Defense
Yes
Oil Storage Tank
800L
Feed Door
70x55cm
Chimney
5Meter
Chimney Kind
Stainless Steel
1st. Chamber Temperature Level
800 ℃– -1000 ℃
second. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
4500kg
Exterior Measurements
230x130x155cm
HICLOVER – Medical EnvironmentalWaste IncineratorsMedical Waste IncineratorPet Animal CremationSolid Waste Incinerator
Tel: +86-25-8461 0201Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.2020-03-21
Items/Model
TS100( PLC)
Photo
Concept
Waste Incineration Treatment
Burn Price
60-80 kg/hour
Control Mode
PLC( Programmable Reasoning Controller Incinerator)
Combustion Chamber
1200L
Interior Measurements
120x100x100cm
Second Chamber
600L
Smoke Filter Chamber
Yes( Dry Scrubber)
Feed Setting
Manual
Voltage
220V
Oil Consumption (kg/hour)
Typical 20.4
Gas Intake (m3/hour)
***
Temperature Monitor
Digital Present
Temperature Level Defense
Yes
Oil Container
1100L
Feed Door
80x60cm
Smokeshaft
10Meter
Chimney Kind
Stainless Steel
1st. Chamber Temperature
800 ℃– -1000 ℃
second. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
6000kg
External Dimensions
260x150x180cm
The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using dieselfuel as a supplemental fuel oil.It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapiddeployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are severalvariations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 yearsif the specified maintenance schedule is followed.The incinerators should be supplied assembled, whenever possible, and all parts and components should bepackaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130)and via sea in a 20’ ISO sea shipping containers.HICLOVER – Medical EnvironmentalWaste IncineratorsMedical Waste IncineratorPet Animal CremationSolid Waste Incinerator
Tel: +86-25-8461 0201Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.2020-03-21
Items/Model
TS500( PLC)
Picture
Concept
Waste Incineration Treatment
Burn Price
150-200 kg/hour
Control Setting
PLC( Programmable Logic Controller Burner)
Combustion Chamber
2700L
Interior Dimensions
190x120x120cm
Second Chamber
1300L
Smoke Filter Chamber
Yes
Feed Mode
Handbook
Voltage
220V
Oil Intake (kg/hour)
Ordinary 28
Gas Usage (m3/hour)
***
Temperature Display
Digital Display
Temperature Security
Yes
Oil Tank
1400L
Feed Door
90x80cm
Chimney
10Meter
Smokeshaft Kind
Stainless Steel
1st. Chamber Temperature
800 ℃– -1000 ℃
2nd. Chamber Temperature
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
15000kg
Outside Measurements
400x210x300cm( without chimney)
The air supply should be controlled efficiently;Flame contact with all the gases should be achieved;The minimum combustion temperature of the primary chamber should not be less than 850°C;The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.The following conditions should be met in the secondary combustion chamber:The air supply should be controlled efficiently;Flame contact with all the gases should be achieved;The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;HICLOVER – Medical EnvironmentalWaste IncineratorsMedical Waste IncineratorPet Animal CremationSolid Waste Incinerator
Tel: +86-25-8461 0201Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]Nanjing Clover Medical Technology Co.,Ltd.2020-03-21
Design
CA-200
Image
Burning Rate
Ordinary 100 kgs/hour
Key Burning Chamber
2000 Liters
Additional Burning Smokeshaft
Yes
Feed Mode
Guidebook
Voltage
220V
Power
3.0 Kw
Fuel Kind
Diesel Oil
Burner
Italy Original
Oil Usage (Diesel Oil)
Typical 53 kg/hour
Interior Dimensions
230 x 100 x 90cm (primary chamber)
External Measurements
290 x 200 x 170cm (key chamber)
Temperature Monitor
Yes
Oil Container Capacity( if oil fuel)
500 Liters
Door Opening
90 x 90cm
Smokeshaft Size
5.0 Meters
Chimney Type
Stainless Steel
Devices Gross Weight
9000 kgs( with container)
Procedure Technical Specifications
Paimary Chamber Temperature
800 ℃–– 1000 ℃
Second Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Burning Efficiency
> 98%
Waste Lower Calorific Power
3000Kcal
2020-03-22
Burner for healthcare facility waste monitoring with the adhering to attributes:
– In high temperatures (pyrolytic burner 2 chambers with temperatures ranging from 950 º C to 1320 º C;
– Capacity to damage of 400 to 600kg per hr;
– Efficient in destroying microbes;
– Drain ash;
– Drain needle as well as glass crusher;
– Patio with tap water for hand cleaning and decontamination;
– Observe the problem of environmental top quality criteria, discharges fluent as well as policy on the issue of waste; mount large incinerator to among the largest veterinary health center in KSA so if you will certainly support us with one system (large incinerator) and ecological with onsite training, the ability for the device is 2000 Kg for cattle, equines and also farm animals additionally suitable to all animal waste kinds, we require it diesel fired. OES-Industrial MultiWaste Incinerator System (Solid/Liquid)
Extent of the Job:
Style, setup as well as commissioning of multi hazardous waste burner.
Capability: 315 KG/HOUR SOLID WASTE/ OR 200 LITRES/HOUR LIQUID WASTE (with double chamber system).
1st chamber-870 Deg.C – – 900 Deg.C.
2nd chamber-1000 deg.C– 1200 Deg.C
Resources Of The Wastes.
The following types of wastes can be dealt with by using incinerator.
a). biography medical waste/pharmaceutical waste.
b). strong chemical waste/textile markets waste.
c). liquid chemical waste.
d). dyes as well as intermediate waste.
e). natural chemical waste.
f). liquid ink waste/acidic deposit.
g). insecticides/herbicides/pesticides.
h). fungicide waste.
i). ethanolamine.
j). amino ethanol.
k). mono ethanolamine.
l). ETA, MEA waste.
m). wastes after treatment of chemicals in etp plant.
n). blended alcohol waste water.
o). alcoholic waste.
p). farming liquid chemical waste.
q). sludge mix liquid.
r). slurry/adhesive/grease/ powder finish wastes.
s). semi strong liquid chemical waste.
t). bulk completely dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass grains.
w). utilized tires.
x). used cotton cloths.
y). contaminated plastics/resin wastes.
Range of Work:.
Incinerate all types of liquid/solid hazardous/chemical/non contaminateds materials avaliable in the industries with appropriate scrubbing up system with common emission rates.
The twin stage incinerator aids to burn the waste in 2 stages, initially at a medium temperature of 870- 900 Deg C and also the 2nd stage at 1200 deg C.
Producing ash as well as Aeriform fumes which are treated with cyclone type damp scrubber as well as caustic scrubber to generate air with contaminants in the allowed variety as well as Non dangerous ash mainly not natural salts.
Incinerator utilities.
Burner should have complying with requirements:.
Metallic seal framework with ceramic insulation to stay clear of warm radiation and also control glowing temperature level.
Advanced gas treatment system to avoid emission of hazardous gases (rubbing system).
Reduced intake high performance compact automated burning system.
Low running and upkeep prices.
Fully automatic and also easy to operate control board.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to enable maximum Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless Steel Case.
Warmth recovery option
Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description Minimum Requirements
Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rakeMaterial of construction Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation to walls 1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base 3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught
Air supply
Electric
Barometric indicator, door operated draught limiter
Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required 415 Volts Three phase.
Auxiliary fuel Electrically operated only
Emission Multiple chamber design with inbuilt emission control
Paint: Case and stack 400⁰C Heat Resistant Grey
Temperature of case 100⁰C
1 Burner 30 =KG burn/h and also it need to have a Scrubber.
2 Burner should have Electric Plastic Shredder for cutting of glass container, surange of Medication.
3 Burner need to have Electrical Car Clave or Microwave for Dis Infection independently with burner.
4 Incinerator needs to have Double Chambers initially Chamber should provided 800C temperature level as well as additional Chamber working 1200C temperature level.
5 Incinerator in out place must have a Specification to show internal temperature level of incinerator.
6 Burner has to operate in 2 systems Electric and also fuel explain in which type of fuel jobs.
Note we want it works on gasoline and also electrical also.for a small pig slaughterhouse task in Vietnam we are looking for a.
solution to ruin securely inedible and confiscated pet items.
As the slaughtered pigs are consumed by more than 90% (from hooves to.
head, blood, etc) the waste volume is fairly tiny also in.
slaughter-points with as much as 100 slaughtered pigs each day.
Although using meat and also bone meal is not banned in Vietnam the.
small quantities of waste do not seem to warrant the installment of a.
rendering system, not also of a batch stove, so incineration seems to be.
the very best option.
I wish to get even more technological details e.g. gas usage for.
blazing 100/200 kg of animal items per day as well as also the FOB.
cost of the unit.The types of waste to be treated are (after EUROPEAN WASTE BROCHURE AND CONTAMINATED MATERIALS CHECKLIST, 2002):
18 01 01 sharps (other than 18 01 03)
18 01 02 body components and organs including blood bags and also blood maintains (other than 18 01 03)
18 01 03 * wastes whose collection and also disposal undergoes special needs in order to avoid infection
18 01 04 wastes whose collection as well as disposal is not subject to unique requirements in order to protect against infection (for example dressings, cast, linen, disposable clothes, baby diapers)
18 01 06 * chemicals containing or consisting of unsafe compounds
18 01 07 chemicals besides those stated in 18 01 06
18 01 08 * cytotoxic as well as cytostatic medications
18 01 09 medications aside from those discussed in 18 01 08
18 01 10 * amalgam waste from dental treatment