50kgs/hr iraq general waste incinerator with Two combustion chambers

Items/Model

TS50M

Picture

 

Burn Rate

Typical 50 kg/hour

Feed Capacity

Typical 50-150 per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

450L

Internal Dimensions

75x75x80cm

Secondary Chamber

225L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Typical 13.3

Gas Consumption (N.G, m3n/Hour)

Typical 16

Gas Consumption (L.P.G, m3n/Hour)

Typical 11.7

Temperature Monitor

Four Digital Screen

Temperature Protection

Yes

Oil Tank

100L

Feed Door

55x50cm

Chimney

8Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

External Dimensions

medical waste incinerator for sale

Waste type: health care waste

It is carried from the floor level on a considerable steel support frame.  Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or higher strength castable.

The primary combustion chamber must ensure minimum exit temp is not less than 850? C.
Certification: NEMA (or other recognized) certificate
Quality/Environmental Standards: NEMA ACT (EMCA) 1999,   BS3316
Thermal conductivity: 1.3W/mk
Hot face material:
Hearth and lower section of chamber walls
Operating period: anticipated daily operating period 8 hours
Burner: ordered for on/off operation
Capacity to support equipment: the agent/supplier shall have adequate facilities, spare parts, consumables and capable skilled technical staff.
Maximum rating: 450kW/hr
Maximum rating: 450kW/hr
Average consumption: 4.5Ltrs/hr
Insulation:
Limiting continuous service limitation 1000? C
Horizontal good hearth, refractory lined primary combustion chamber.  Approx. Measurements 800x2100mm(DxL)
Chimney/Stack: Should be manufactured from refractory lined mild steel or higher quality air-cooled s/s.
Maximum consumption: 9Ltrs/hr
Thermal conductivity: 0.095W/mk
Manual loading door
Estimated ash residue: 5 — 10%
Super duty firebrick
Electrical supply: single phase: 220/240VAC; 50/60Hz

Documentation:
Chamber: should be refractory lined into the following standard;
Average consumption: 3Ltrs/hr
Nominal capacity: 50kg/hr batch load
Full sized bulk load/ash removal door
Afterburner:
Thickness: 25mm
Ash: The waste will be reduced by 90~95% to leave 10-5% ash
Medical waste incinerator for sale Operation manual: 2 sets
Training: the Agent shall conduct a two times incinerators training after installation and commissioning of the equipment.

The Agent shall conduct a two days operation & maintenance training to the Biomedical engineering personnel following installation & commissioning of the equipment.

Incinerator with Movable platform & Automobile.Door and Design for Pets Human Cremation Business

Design for Pets Cremation Business

Movable platform & Auto.

Independent Position for Small Pet

Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business

Model

A1500

Picture

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 350 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Fuel Type

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 53.0 kg/hour

Gas Consumption (Natural Gas)

Average 63.6 m3n/hour

Internal Dimensions

150 x 100 x 100cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if petroleum fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

8000 kgs


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Smallest Incinerator 30kgs

Average 30kgs per hour

***Main chamber(200Liters)

*** Secondary chamber

*** Mix combustion chamber

*** Stainless Steel chimney(1meter)

*** Italy made oil burner(2sets)

*** Dry Scrubber

*** Weight 1.7T(can reduce to 1.0Ton)

Main Spare Parts(Standard for incinerator, and price Comprise already):

*** 2 sets Italy Oil Burner

*** 2sets Temperature Probe

*** 1 set Control Case

*** 1 set Air Fan

*** 1 Place Diesel Oil Tank



HICLOVER – Medical Environmental 

*** 1 Place Maintain Material


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

incinerator manufacturers

d) A smoke density meter/recorder should be provided.
G) The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16 hours.

– Manual technical monitoring is shipped with the hardware together with all explanations of failures and resolutions
B) The room should guarantee a minimum exit temperature of 850 degrees centigrade.

2.4 Secondary Combustion Chamber (After burner)

a) ought to be fitted with burners using low sulphur fuel.
2.6 Chimney/Stack

l) The chimney should have a minimum height of 10 metres above ground level and clear the highest point of the building by not less than 3 metres for all roofs. The topography and height of adjacent buildings within 50 metres radius should be taken into consideration.
1. Supply, install and commission an incinerator as provided in the technical specifications
B ) The temperature of the primary chamber shall be 800 +/- 50 degrees centigrade
Controlled hygienic mechanical feeding that does not negatively influence the air temperature at the primary and secondary chambers of the incinerator shall be used.
M) The chimney should be visible to the operator in the feeding area.
1. Overall plant layout
Capacity/island: 4000 kg/day; 25000 kg/day; 31000 kg/day; 48000 kg/day

Burning temperature — more than 12000C

Two chambers — minimal

Emissions — dioxin and heavy metaly — better then Kyoto protocol

Emission — monitoring system

Waste unloiding — directly from waste track to incinerator

2.5 Particulate Removers

A mechanical particulate collector must be integrated after secondary combustion chamber for removal of particulate pollutants entrained in the flue gas flow.
3. Assessment and preparation and construction of a normal incinerator drop with one waste storage space ( see the design )

4. Provision of maintenance and operation manuals and drawings complete with maintenance schedule and directions.

5. Fuel oil storage tank- Moderate steel1500 liters capacity

6. Onsite training for maintenance and operation staff.

IMPORTANT
N) The minimum exit rate should be 10 metres per second and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting gases.
D) Make sure the gas temperature as measured against the inner wall at the secondary chamber and not in the flame zone is not less than 1100 degrees centigrade.
F) Any other instrument which may be considered necessary.

2.9 Emission Limits

a) Combustion efficiency (C.E) shall be at least 99.00% where C.E =%Carbon dioxide x 100 / [% Carbon dioxide + carbon dioxide ]
7. Minimum capacity of main chamber = 0.18 cubic metres
2. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during implementation of the functions covered in this tender.
E) Make sure the emitted oxygen content of the emitted gases is not less than 11%
5. Acid gas scrubbers.
6. The stack/chimney.
C ) Ensure residence time is not less than two seconds.
Incinerator manufacturers To allow the Employer undertake conclusive evaluation of the tender, tenderers are requested to submit with their offers the detailed specifications, drawings and catalogues with commissioning and maintenance instructions for the Incinerator they intend to provide, install and commission. Tenderers who don’t comply with this requirement fully shall have their tenders rejected. 2. TECHNICAL SPECIFICATIONS OF THE REQUIRED INCINERATOR

2.1 General Description

The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not Limited to:
2.3 Primary Combustion Chamber.

a) This room should be equipped with burners using low sulphur fuel.

1.
D) Opacity of the smoke shouldn’t exceed 20% seen from 50 metres with naked eyes.
3. Primary combustion chamber
O) The point for measurement of emissions shall be provided.

2.7 Instrumentation

a) Instrument for determining the inside wall temperature and not burner flame temperature must be given for both primary and secondary chambers.
9. Should have a full width counterbalance loading door allowing easy access to the main room for loading and removing ash.
F) A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed in which DRE [ ( Win – Wout) /Win ] x 100 where Win = mass feed rate of the POHC in the waste stream fed into incinerator and Wout = mass emission rate of POHC in the stack before the release to the atmosphere.
E) A solid particulate meter/recorder should be provided.
4. Particulate scrubbers
8. Burn rate (rate of waste incineration) = a least 20 kg per hour
B ) An audible and visible alarm must be installed to warn the operator once the secondary chamber temperature drops to below the required temperature.
C ) The secondary chamber gas residence time shall be at least 1 minute at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack gas.

Waste unloiding – directly from waste track to incinerator

Melt blown Production Line 400mm and 1600mm and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. 400mm and 1600mm Melt blown Production Line

3. ES Fiber Production Line

 

 

 

N95 Face Mask Machine Production Line

Melt blown Production Line

 

A.)Optional Ability: 1600mm

Efficiency: 95-97percent

FOB Term Cost: USD per set

Price Valid: 5days.

Ave.60 Days prepared for shipping.

In stock Price: USD per set

 

 

B.)Optional Capacity: 400mm

Efficiency: 40-50%.

FOB Term Cost: USD per set

Price Valid: 5days.

Ave.20 Days prepared for shipping.

Payment: TT 70% In advance, TT 30% before leave factory

Shipping: 1*20′ container per set, Ave. 2000Kgs.

 

Main Parts: Extruder, mould, winder, oven, ultrasonic

Daily Capacity:100-150Kgs/24Hours

Screw extruder:100-150Kgs

Motor power: 15KW frequency conversion speed regulation Reducer speed ratio: 1:10 or 1:16 Screw length to diameter ratio: 30: 1 Screw diameter: 50mm Winding machine diameter: £ 630mm Winding machine drive motor power: 0.55kw Speed ratio of winder drive reducer (if any): 1:71 Air heater power: 15kw Power of vacuum calciner: 12kw The size of vacuum calciner: 500 × 300 × 200 Ultrasonic power: 1800, frequency 28kHZ Ultrasonic sink size: 800 × 300 × 250

 

 



HICLOVER – Medical Environmental 

2020-04-20


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-20

medical incinerator manufacturer

9. Metal fuel tank from black steel (capacity not less than 2500 litres) and will be installed in the incinerator Room. The tank shall be supplied with all necessary fittings such as fill, vent, drain and overflow line, level indication and accessibility for inspection and maintenance. Level switches shall be provided for these services.
– The capability of the liquid waste treatment (blood, urine stained, other body fluids contaminated, regardless of what quantity packaging?
5. There will be a different burner each for the primary & secondary room. The heat input capacity of each burner will be sufficient to increase the temp.in the primary & secondary chambers as 800+/- 50dc and 1050+/-50dc respectively within maximum of 60 minutes prior to waste charging. The burners will have automatic shifting off/on control to prevent the fluctuations of temperatures beyond the essential temp.range.
– Is there  microbiological testing particularly: the processing efficiency bascillus

10. A ready built fabricated space shall be provided for home the incinerator. The space will be designed in such a way that free space is  available  on all sides and heat radiation  maintained at minimum and giving the operators a simple workable environment and venting. The materials will be adequate structural thickness of mild steel angles neatly coated with metal primer and epoxy paint to withstand sea corrosion

1. The double room incinerator shall preferably be designed. Air supply from the primary and secondary chamber shall be controlled between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be provided through a separate forced draft fan accounting for the air provided through burners. Provision shall be made in the principal chamber to measure the water column pressure.
6. Incinerator shall have graphic or computer recording apparatus which shall automatically and continuously monitor and record dates, time of day, batch sequential number,Co,Co2,O2 in gaseous emission will also be  measured daily.
4. The incinerator shell shall be made of SS/MS plate of adequate thickness (minimum 5mm) and painted externally with heat resistant aluminium paint suitable to withstand temp.of 250 dc with appropriate surface preparation. Refractory lining of the hot duct shall be accomplished with refractory castable (minimum 45mm thick)& insulation castable(minimum 80mm thick). Ceramic wool shall be used at hot duct flanges & expansion joints.
– The efficacy of process chemicals (after neutralization and cleansing: fluids and solids )

(a) Low level alarm
(b) High level alarm
(c) Low level start of transfer pump
(d) High level stop of transfer pump

10.A ready built fabricated room shall be supplied for housing the incinerator. The room will be designed in such a way that free space is  available  on all sides and heat radiation  kept at minimum and giving the operators an easy workable environment and ventilation. The materials will be sufficient structural thickness of mild steel angles neatly coated with metal primer and epoxy paint to withstand sea corrosion
– effectiveness for the treatment of placenta? and expired or spoiled drugs, cytotoxic and cytostatic drugs prescribed: narcotics eg
– Does it allow to treat drug or waste containing glass (whatever color: transparent or colored white) without causing explosions?
– The ability of the liquid waste treatment (blood, urine stained, other body fluids contaminated, regardless what volume packaging?
– The efficiency of process chemicals (after neutralization and detoxification: solids and liquids)
– Is there  microbiological testing especially: the processing efficiency bascillus

laboratory incinerator

the Whole carcass of animals ( Horses, Cows,

air retention for at least 2 seconds at a temperature of less than 850C, the combustion
C to – 15 0C laboratory incinerator
Temperature and 5% – 95 percent – of moisture conditions.
Which are managed remotely by the operator.
? Fully mobile – mounted on wheeled chassis
?
Potential to minimize (approximately 5% sterile ash
Fuel stoves
? The ability to pre- warm-up, body waste burning on and off
8MJ/kg- material and 60% humidity.
Products from the fuel stove.
Form).
Sheep, pigs , etc.) , as well as biologically hazardous waste
Even during the surgery.
Must be installed on the generator.
Consistency is independent of the first and secondary chambers.
In order to achieve the proper effect.
? Ensuring the incinerator with electricity, it
The destruction of 1000 kg / hour.
Information on the variation of temperature with respect to time and
? The waste products to reduce the initial volume

?
? Designed to work in long mode and quick
Without using any additional equipment

Medical Incinerator Manufacturers in Stock ready for Transport

Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for Outdoor face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Typical 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st.

800℃—1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

HICLOVER – Medical Environmental 

300x160x280cm(without chimney)


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

medical incinerators

● Willing to burn 25-30kg per hour

2 sec.
1000×1670
-Stainless steel stack
Width (mm)
-Automatic control and temprature
790
● Need more than 15amp 220- 250V power
·         General wastes produced on a daily basis  include paper, plastic, organic materials, boxes, plastic containers, leaves, etc;

·         Total waste produced daily: 10-12 tonnes;

·         Hours of Operation: 10 hours a day;