Tag: waste-incinerator

Medical Waste Incinerator in Stock for Coronavirus Disease COVID-19

HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medical Waste Incinerator for Coronavirus Disease COVID-19


HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medical Waste Incinerator for Coronavirus Disease COVID-19


HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Incinerators QA

Q: what is kind of waste can use in this equipment?
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any 

explosive and radiation material, liquid waste and gas waste.

Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour), 

not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.  

Clover incinerator use time daily to 24 hours.  Between each feed/combustion time, 

there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion 
time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. 

When incinerator use in hospital, please calculate the waste output capacity around 2kgs 
per people per day. If there are 200 sickbed in the hospital, that’s mean you need one 
incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs 
per hour. According the operation time per day, waste material, budget, 
development, etc, you can use capacity from 30-50 kgs per hour incinerator.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.

Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Customer 

can send people come to our factory to learn installation and operation. Generally, 
We do not send engineer to local site if not request. The dispatch cost is extra according to order.

Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level.

Q: Incinerator Control ModeA: Default Control mode is common control case.  PLC mode according to order and model.

Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000usd annually care according model, use scenario. 

One individual can service 02 device incinerators.  The team should have basic electrician 

knowledge to operate/inspect/maintaince incinerator/burner/blower according to 
operation user guider, and know risk of medical waste to protect worker self with necessary protection element.

Q: The Residency time in secondary combustion chamber

A: 02 sec.
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incineration Furnace for burning patalogical

CO – Shouldn’t exceed 100 mg/m3

SO2 – Shouldn’t exceed 400 mg/m3

HF – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3

NO2 – Shouldn’t exceed 500 mg/m3

Smoke dust  – Shouldn’t exceed 100 mg/m3

9    Height of the Incinerator – less than 10m above ground level

10    Manufacturer’s Warranty – less than 1 year

11    Electrical Connection – From closest distribution box using 25mm2 electric cable and all related connections and wiring

incineration Furnace for burning patalogical  ( such as human tissue or blood ) as west

The weight  of this west materials is 700 kg per month and we want an  isolated furnace

Without fume and any harmful gas

. INCINERATOR SPECIFICATION

# Description Specification

1    Burning Capacity – 400 kg/time and should not be less than 300 kg/time. Maximum combustion time needs to be 6 times/day

Two Chimney external diameter  – 300 to 400 mm

3    Fan power  – Shouldn’t exceed 1.1kw

4    Voltage  – 220V

5    Oil consumption  – Shouldn’t exceed 14kg/h

6    Feeding door diagonal dimension (mm)  – less than 500mm

incinerator Model TS150

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.

Medical waste is posing a growing problem all over the world, jeopardizing the health of Patients, Staff, disposal Employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. 

WWW.HICLOVER.COM|Waste Incinerators

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Technology Co.,Ltd..

cytotoxic waste

it’s also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also the characteristics and disposal of treatment residues. Moreover, operational needs in terms of electricity and fuel consumption, as well as especially the off-gas treatment system implemented, bear significant importance, as fulfilling the requirements of Regulation 2010/75/EC is naturally necessary.

The quantity of disposal is about 100 kg per day as minimum. Bigger skills up to 500-600 kg/d will also be of great interest to us. Thus, please send us your suggestion for both aforementioned daily capacities.

The quantity of disposal is about 100 kg per day as minimum. Bigger capacities up to 500-600 kg/d are also of great interest to us. Thus, please send us your proposal for both aforementioned daily capacities.

HICLOVER INCINERATORS

Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this broad range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Health Clinics and Health center can now manage their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that may potentially spread diseases or viruses.

 

Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create an assortment of health and environmental risks if not managed and destroyed in an appropriate manner.

With years worth of expertise in this industry, our medical range of incinerators are designed to cater to the economical needs of small clinics to the demanding and technical requirements of large hospitals in their waste management processes.

 

HICLOVER is now offering a full range of medical waste incinerators, designed to offer efficient waste destruction, using best available technologies and environmentally friendly procedure. As a result of secondary chamber with its 2 minute retention interval, our medical incinerator range is ideal for process medical waste.

 

Our products guarantee efficient, clean and hassle-free disposal of medical waste is possible.

 

 

○Middle-Small Ability (TS Model)

※Main Features:

— Double Combustion Chamber

— Double Italy Burner

–Burning Rate: 10-100kgs per hour

–Combustion Chamber: 0.1M3-1.2M3

※Optional Function/Parts/Material/Burning Rate:

— Stainless Steel Chimney

— Dry Smoke Filter Chamber

— Chimney Height Custom Made

— Upgrade/Downgrade Burning Rate

 

 

○Large-Middle Ability (YD Model)

※Main Feature:

–Three Combustion Chambers

— Double Italy Burner

–Burning Rate: 30-600kgs per hour

–Combustion Chamber: 0.36M3-5.5M3

※Optional Function/Parts/Material/Burning Rate:

— Stainless Steel Chimney

— Dry Smoke Filter Chamber

— Chimney Height Custom Made

— Semi-Automatic Waste Feeding

— 3-Section Wet Scrubber System

— Movable Platform Feeding Door

— Additional Burner

— Upgrade/Downgrade Burning Rate

 

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

1.  

21. The de- ashing must be performed in the bottom of the combustion chamber or the deashing
Electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating
* A timer with flexible temporization for the regulation of every burner.
* Carcass in solid sheet steel with support of link.
* A regulator with electronic viewing for the temperature of postcombustion.
Should be Automatic or manual batch p ashing.

22. Process Filtering system: Scruber to be mentionned as optional

23. Emission Standards Compliance: BS 3316 or equal standard

23. Ability to treat Plastic: Not less than 40% by weight

24. CE Manufacturing Compliance: BS EN 746-2-1997

22. The provider must give batches of spare parts of first urgency and consumable of this
* A device of air inlet of cooling of waste gases,
Flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice
valve.
* A device of injection of air allowing a total recombustion of gases,
* A secondary shot of air to ensure perfect oxygen content.

19. A control box ensuring that the complete cycle of combustion.

20. Fan:
incinerator.

23. The installed incinerator must bear a 1 year guarantee.
16. The provider must provide necessary information for the best of this installation This incinerator
* A switch circuit breaker for each engine (ventilators and burners).
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and security of
* The insulation of the combustion chamber should be composed of refractory bricks,
10. The lower calorific power (L.C.P) of the waste will be 3,500 kcal/kg
6.  The incinerator must avoid the release of black smoke and fine dust, (Smokeless) throughout the
9.  The incineration should be wholly free from visible smoke as well as offensive odours.
>  Nature: 65% of A1203
loadings.
Stuffing insulating out of refractor. -.
>  Nature: Calcium
•    The Temperatures of combustion: Minimum will be 850°C and max 1400°C
> Nature: 42% of A1203
5. 
3.  This incinerator must be able to destruct all combustible wastes produced by hospitals,
Private practices, laboratories, institutes, etc…
15. Fuel: diesel
Mill; it will include curative and preventive maintenance, and using equipment, etc

NB.; Civil works and any other relevant services for the installation and training of operators have to be included at the incinerator’s cost.

Specification for the refuge of the incinerator:

House of the incinerator inclusive in offer (the house must have toilet and hand washing facilities and firefighting). The size of the shelter shall measure four meter by six meter and shall be provided with adequate air ventilation.

This material and equipment must include in the shed of the incinerator: base in rubble stone, isolation roofing against humudity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel frame (charpente en metal); roof in sheet B.C.A. 28 BG

25. The technical training of operators will have to be supplied and given by a technician from the
Using a high content of aluminum and insulates bricks in order to assure a minimum
Load
* A burner of light that the use is restricted to the ignition of waste.
11. The Inner diameter of the Chimney: Ø 400 and its height: 8 m
14.
With “PYROLYTIC” combustion must possess:
*  Plate of combustion in Carborundum, preventing the fixing of glass and slags.

18. A chamber of post combustion of gases
Completed by valves and following the control of the automatic cycle.

Pet Animal Crematory Incineration

Incineration is the most obvious solution for total destruction of municipal waste, avoiding 

all the direct and indirect risks associated with other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the 
same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level.

— Upgrade/Downgrade Burning Rate
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Tel:  +86-25-8461 0201