Tag: Medical Environmental

Types of waste Generated in the health facility

HICLOVER Incinerator/Parts Range


Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration



Temperature Control, Primary and Secondary
Stoking tools
Stainless Steel Spark Screen
Primary Chamber Door Locking System

HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)

2. Auto Roll Air Filter for Clean Room(Air Purification)

Nanjing Clover Medical Technology Co.,Ltd.
Tel:  +86-25-8461 0201    

Mobile: +86-138139 31455
WhatsApp: 008613813931455
WhatsApp: 008615380948599
Twitter ID: @hiclovercom
Wechat: 008613813931455 (ID: hiclovercom)
Wechat: +8615380948599 (ID: wasteincinerator)

Website1: www.hiclover.com 
Email1:     [email protected]
Email2:    [email protected]    
Email3:   [email protected]  

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Brand HICLOVER HICLOVER HICLOVER HICLOVER
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm


Prefabricated Incinerator with a concrete base and chain link fence.The incinerator should be portable, very easy to install, allow for re-location, fit in small space with a chimney length of 4m to drive smoke away to safe heights and also cause current flow of fresh air to drive moisture out of the rubbish such that the bad odour from sanitary pads is removed and the waste is dried automatically. The incinerator should be made of a non-rusting material such as stainless steel of 4mm gauge. It should not require an extra heat source, but use the heat generated from burning of the solid waste as its major energy source. This incinerator should be capable of raising temperature to its maximum within three minutes and the heat losses kept to the minimum.Average Temperature
Average Temperature; 850 degrees Cent grade (As per Ministry of Health) 
Capacity Capacity; 60 Liters, Auto combustion/nonfuel assisted 
Destruction rate 30 liters per hour, waste reduction up to 95%volume
Batch Load 5Kgs per load
Life Span Life span; minimum 10 years

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

CE and ISO Certification Pass Incinerators

 

2021-03-02

Poultry Incinerator Design for Pets Cremation Business


Model

A1500

Picture

 

Brand/Product Code

HICLOVER/N1134

Burning Rate

Average 50 kgs/hour

Feed Capacity

Average 150 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 34 kg/hour

Gas Consumption (Natural Gas)

Average 41 m3n/hour

Internal Dimensions

150 x 100 x 96cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7500 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

Pet Incinerator,Best incinerator manufacturers
HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)

2. Auto Roll Air Filter for Clean Room(Air Purification)

Nanjing Clover Medical Technology Co.,Ltd.
Tel:  +86-25-8461 0201    

Mobile: +86-138139 31455
WhatsApp: 008613813931455
WhatsApp: 008615380948599
Twitter ID: @hiclovercom
Wechat: 008613813931455 (ID: hiclovercom)
Wechat: +8615380948599 (ID: wasteincinerator)

Website1: www.hiclover.com 
Email1:     [email protected]       
Email2:    [email protected]    
Email3:  [email protected]   

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Brand HICLOVER HICLOVER HICLOVER HICLOVER
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg
Control Mode PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm
Chimney 3Meter 3Meter 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


CE and ISO Certification Pass Incinerators

 

2021-02-28

Garbage Incinerator TS150 PLC Mobile Type


Items/Model

HICLOVER TS150(PLC) (Mobile Type) N1155

Picture

 mobile incinerator

Principle

Waste Incineration Treatment,trash incinerator

Burn Rate

Average 150 kg/hour

Feed Capacity

Average 150kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Oil Consumption (kg/hour)

average 20.4

Gas Consumption (m3/hour)

average 24.5

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

260x150x180cm(Incinerator)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-28

Biomedical waste management ppt

Items/Model

TS50(PLC)

Picture

Principle

Medical Waste Incineration,dual chamber incinerator

Burn Rate

50-100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Consumption (kg/hour)

average 16.9

Gas Consumption (m3/hour)

average 20.2

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

5Meter

Chimney Type

Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

4500kg

External Dimensions

230x130x155cm

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


No

Description

Specification

 

1

Type

Dual Chamber (Primary + Secondary Type Controlled Air Pyro Lytic Biomedical Waste Incinerator with Chimney Arrangement

yes

2

Incineration Capacity

>50 Kg. per hour

Yes, 50-100kgs/hour

3

Duration of Use

As per operational conditions

Average 10years

4

Number of Chambers

02 No.s

yes

Number of Burners per Chamber

01 No.s

yes

5

Total burners per incinerator

02 No.s

yes

6

Primary Chamber Operation Temperature

Max. 900 Degree Celsius

800-1000 Degree Celsius

7

Secondary Temperature
Operation Temperature

Max. 1075 Degree Celsius

1000-1200 Degree Celsius

Design Temperature for both chambers

Max. 1500 Degree Celsius

1750 Degree Celsius

8

Incinerator Efficiency

98-99 %

yes

9

Refractory Materials

High Alumina Refractory

High Alumina Refractory and firebrick

10

Refractory Type

Castable type

yes

11

Ash Removal

Manual Removal Drawer Tray

yes

12

Material of Construction of Chamber

IS 2062

Q235, same as IS2062

13

Type of Burner Used

Fully Automated Electrically operated burner with Head with photo cell for flame supervision Nozzle and Electrode

yes

Connection hoses , Ignitor , Pump Fan & Cabling System

yes

14

Qty.

01 No.

 

15

Power

230 / 440 V as per availability at end user

220-240V

16

Electrical Cabling

Within battery limits

Standard 3Meter

17

Refractory

 

18

Type

Castable Type

yes

19

Anchor Fasteners

AISI 316

Firebrick made,none anchors. S.S fiber 446

20

Coating on Anchors

Parafin

none

21

Alumina Percentage

40-60 %

Above 60%

22

Density

2.1 g/Cubic cm

3-3.5 g/Cubic cm

23

Service Temperature Max.

1500 Deg. Celsius

1750 Deg. Celsius

 

Insulating Castable

 

24

Type

Castable

High alumina ceramic fiber Insulation

25

CCS at 110 Degree

35-45 Kg /Sq. Cm.

None parameter

26

Grain Size

5 mm

None parameter

27

Density

1.2 gm / cm3

220kg/m3

28

Service Temperature

1350 Degree C

1260 Degree C

 

Control Panel

 

29

Degree of Ingress Protection

IP 55

yes

30

Panel MOC

SS 304

yes

31

Panel

Cabinet with Observation Glass and PLC Programmer

yes

32

Chimney

 

33

MOC

IS 2062

yes

34

Height

As per requirement

5 meter

35
36

Total Space Requirement
Completed with all Civil and Electrical

Maximum 5 Mtr. X 5 Mtr. Work

yes


 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23

Medical Waste Management System

Items/Model

TS50(PLC)

Picture

Principle

Medical Waste Incineration 

Burn Rate

50-100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Gas Flue Washing System incineration of medical waste

Feed Mode

Manual

Voltage

220V

Power

4.0 Kw

Oil Consumption (kg/hour)

average 16.9

Gas Consumption (m3/hour)

average 20.2

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

15Meter

Chimney Type

S.Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

550x150x200cm


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers,biomedical waste management pdf 2020

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

ü BIO-Medical/Hospital Waste Incinerator Modular Package Type, free standing unit consisting of (Primary chamber, Secondary Chamber, stake, controller and gas flue washing system) how does a waste to energy plant work

ü Diesel Oil And GAS Fired Burners (Dual)

ü Stainless steel stack for longevity

ü Burning capacity: 50-60kgs of waste destroyed per hour. 

ü Average ash residue: 3 to 4%

ü Operating Temperature 850°C to maximum 1320°C or better:

ü Upto 1150°C in a secondary chamber

ü Residency Time in Secondary Chamber of 2 seconds 

ü Thick refractory lining & insulation more than 200mm rated to 1600°C in main chamber retains heat, increasing efficiency

ü Separate doors for loading and ash removal

ü Loading door for maximum operator protection for direct heat exposure

ü Burner with temperature activated modulating control

ü Dual HT Thermocouples: Allow independent control of Primary and secondary temperature via the control panel

ü Pressure blower with modulating air control    

ü Stainless steel cladding for maximum heat retention, cool touch and hygiene control

ü Rapid, complete and efficient medical waste disposal

ü Safe use handle

ü High quality refractory lining and insulatio,management of hazardous waste

ü PLC touch screen, dual burner control, preset burn times and blower

ü Temperature monitoring

ü Programmable digital temperature controls for complete combustion

ü Secondary burner temperature activated modulating control

ü Fast pre-heat and continual high temperature performance

ü Heavy duty lock: Designed by us to ensure tight locking chamber with no air gaps. Easy to open and close

ü Low energy consumption levels

ü 2 efficient high efficiency burners for better fuel saving to save per hour fuel burning cost.


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23

Incinerator for Waste Management Facility and Spare Parts

Items/Model

TS500(PLC)

Picture

 

Principle

Waste Incineration Treatment

Burn Rate

Average 500 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2700Liters (2.7m3)

Internal Dimensions

190x120x120cm

Secondary Chamber

1300Liters (1.3m3)

Smoke Filter Chamber

Dry Scrubber Chamber

Feed Mode

Manual

Voltage

220V

Power

3.0Kw

Oil Consumption (kg/hour)

Average 44(DO)

Gas Consumption (m3n/hour)

Average 53(NG)

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

400L

Feed Door

90x80cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

15000kg

External Dimensions

400x210x300cm(without chimney)

Phone: +86-13813931455(whatsapp/wechat)

Nanjing Clover Medical Technology Co.,Ltd.
Supply. Delivery. Insta llation, Commissioning a nd Maintenance of Industria l Standard Solid Waste lncinerator.CONTRACTOR shall be responsible to supply on-the – shelf industrial solid wast e incinerator and its accessories in the market and/or fabr icate its auxiliary related equipment for comprehensive functionalities. Capac ity 500 kg/ hour {dual chamber inc ineration) electricity from garbage
1.Primary Chamber Destruction of Mater ial (>850°C) .
2.Secondary Hazar dous carcinogenic destroyed).
Chamber Destruction of Gas (>1200°C to ensure induced gases is fully Waste type Compatibility
General Wastes/Industrial Wastes/Bur nable
Wastes/Medic al Wastes/Oily
Sludge/ Contaminated Soil/ Saw Dust.
Fuel type Dual Type (Diesel and Gas)
Secondary Chamber &
A ir Pollution Control (APCS) Capabilities
System Compa ny declaration that the equipment is capa ble to remove VOC’s. CO, No×,Dio×ins
&     Furans     (through     high    temperature f iltration), particulate matter. Heavy Metals (Pb, As, Sb, Cd, 丁I) – Result from an accredited lab.
2.Blac k smoke control technology : Dry scrubber, longer residence time in secondar y c ha mber (to ensure complete combustion, kill virus) .

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

incinerator design for schools


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


microwave irradiation of biomedical waste

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23

guidelines on waste management Incinerator Model YD-20C

Item

Specification

Model

YD-20C

Main Product List

 

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)

Italy oil burner: 02 sets

Oil Tank: 100Liters

 

Optional:

Mobile Trailer for Incinerator


Mobile Type Incinerator


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

Items/Model

YD-20C

Burning Rate (kgs/Hour)

Average 20 kgs/hour

Feed Capacity (kgs)

Average 40 kgs/feeding

Equipment Weight

2100 kgs

Primary Chamber (Liters)

200

Secondary Chamber (Liters)

140

External Dimensions (cm)

170x140x160

Internal Dimensions (cm)

55x55x65

Oil Tank(Liters)

100

Door Opening (cm)

38 x 48

Chimney (M)

5.0

Chimney Type

Stainless Steel

Secondary Chamber

YES

Mix-Combustion Chamber

YES

Smoke Filter Chamber

YES

Combustion Fuel

Oil/Gas

Residency Time

2.0 Sec.

Temperature Monitoring

YES

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23

MEDICAL WASTE INCINERATOR


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.
1. Incinerator 10kg per hr
2. Incinerator 20kg per hr
3. Incinerator 50kg per hr
4. Incinerator 100kg per hr
5. INDOOR INCINERATOR

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

medical waste disposal methods


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

PORT SUDAN


 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports.
The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour).
“The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables:
• A first aid kit, suitable for addressing the hazards presented by the unit.
• 5 full sets of personal protective clothing and equipment.
• Operating logbooks.
• Unit cleaning equipment.
• Unit routine maintenance equipment and associated spare parts.
• Lubricants as appropriate.
• 3 Fire extinguishers.
• Any other consumables considered necessary by the Supplier.

 

2021-02-23

what are the main products of incineration process

Items/Model

TS800

Picture

 

Principle

Animal Waste Incineration Treatment

Burn Rate

Average 300-450 kg/hour

Feed Capacity

Average 1200kg/feeding

Control Mode

Electric Control

Combustion Chamber

3000Liter

Internal Dimensions

300*100*100 cm

Secondary Chamber

***

Feed Mode

Manual/Forklift

Voltage

220V/380V

Power

5.0Kw

Oil Consumption (kg/hour)

***waste to energy plants cost

Gas Consumption (m3/hour)

Ave.22.8m3n/hr

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

***

Feed Door

200x100cm(Electric Opening)

Chimney

3Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

500x220x190cm(without chimney)


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

what are the main products of incineration process

Maximum load of the camera (kg)

1200

1200kgs

Overall dimensions (without burner), (mm)

2823x1970x1724

500x220x190cm(without chimney)

2823x1970x1724 chamber Volume, m3

2.5 m3

300*100*100 cm, 3.0m3

EXT.main camera size

(d)2392x (b)1140

???

Size of loading opening, (mm)

(W)1152x (l)1425

W.1000*L.2000mm

Combustion temperature (C0)

650° – 1100°

800℃–1200℃

Weight (kg)

4500

7000kg

Weight of residues after combustion (kg)

no more than 5%

no more than 5%

Opening the hatch with a winch

availability

power-driven

The method of loading

the vertical

Top Feeding Door

Burners

Gas burners

Gas burners

Fire-resistant gasket,why is medical waste a problem

Z-blok fire-resistant gasket

Fire Brick and Refractory castable

Pipe dimensions (diameter, length) (mm)

1420×3000

???

Availability of fire-resistant gaskets

Yes

yes

Temperature properties of the gasket (C0)

1650°

170C

Lining layer (fireclay brick)(mm)

114

114mm

Temperature properties of the lining (C0)

1650°

170C

burner gas (m3 / h)

9.9-17 m3 / h

22.8m3n/h max.

Burn rate (kg / h)

300-450

300-450

Electricity (volts/Hz)

220/50 Hz

220/50 Hz

Auto-ignition

Auto-ignition Yes

Auto-ignitio

Temperature sensor

availability

availability

Automatic control panel

the presence of

yes

Burn time at full load (hour)

4-8h

yes

Compliance of MPV and MPC emissions

corresponds to

China Standard

Painting

heat-resistant enamel

yes


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm



A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended.
The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content.
“The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment.
 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23

steps of waste management

Item

Specification

Model

A1500

Internal Dimensions

150 x 100 x 96cm

Suit for Animal

Cat – yes

Dog – yes

Pig – yes

Cow small

Main Product List

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Wet Scrubber( Washing Tower)

 

Incinerator Control Case

 

Chimney:10.0Meters *(upgrade to Stainless Steel, free cost)

 

Italy oil burner: 03 sets

 

Oil Tank : 500Liters


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

hospital waste management ppt 2018


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


brick incinerator design,The control system shall include an electronic performance monitoring and logging system. The system shall be capable of monitoring and logging chamber temperatures at regular intervals (not less than once per minute, with the capacity to vary the logging frequency). The system shall include the capacity to download the performance data by USB connection.
All the measuring devices attached with the incinerator should have digital display and should have provision of connecting to the recording system, which should include fuel meter and separate energy meter.
The temperature shall be determined against the inside wall of the combustion chambers. An audible and visible alarm shall be installed to warn the operator when the secondary temperature drops to below the required temperature.
The primary chamber must meet or exceed the following criteria:
“• Heavy steel construction.
• Fixed hearth geometry and starved air gasification operational mode. 
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. 
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. 
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints.
• Multiple electric ignition fuel burners designed to use automotive diesel fuel.
• Flame of the primary burner shall be oriented towards the center of the unit which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame. 
• The unit shall prevent leakage of the hot flue gas and any backfire. 
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• Digital thermometers connected to electronic dataloggers. The thermometers shall be located on the chamber walls away from the fuel burner.
• A differential air pressure gauge connected to an electronic datalogger

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-22