Biomedical Waste Incinerator, 10-15 KG 

The first is a small
20kg/per hr incinerator for a small-medium sized hospital, and the
second is a 500kg per/hr incinerator for a company planning to start a
incineration service in Lahore.Burn Rate : >200 kg per hour
Average fuel consumption : ~29 kg per hour ( Or lesser)
Gas Retention in Secondary Chamber : 2 secs
Temperature Monitoring : Yes
Average Ash Residue : 3%Medical waste management practises here are sub-standard. I have come across your small scale medical waste management units.Biomedical Waste Incinerator, 10-15 kg
Manufacturer:
Brand:
Type / Model:
Country of Origin:
Description of Function
The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste.
The Disposal of such Biomedical waste is a very important as it is a dangerous wastes for
human life, and It is only possible with a perfect incinerator.
Operational Requirements
It shall be operated by manual and automated mode.
The combustion efficiency (CE) shall be at least 99.00%.
The combustion efficiency is computed as follows:
C.E.= __%CO2______ x 100
%CO2 + %CO
Emission Standards: Lower emission rates are preferred.
Parameters                   Concentration in mg/Nm3 (12% CO2 correction
Max total dust              30mg/m3
Max Sulphur Dioxide      200mg/m3
Max Nitrogen dioxide    400mg/m3
Max Carbon                     100mg/m3
Monoxide
Minimum stack height shall be 30 metres above ground.
Volatile organic compounds in ash shall not be more than 0.01%.
System Configuration
Biomedical Waste Incinerator, complete unit.
Technical Specifications
Incinerator:
It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic.
Type of Waste: Biomedical Waste
It shall have burning capacity 10-15 kg/hr.
Fuel: Diesel
Burner: Monoblock fully automatic burners.
Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC.
Type of Waste: Biomedical waste with moisture content up to 85%.
Destruction Efficiency: 99%.
It shall have separate digital display of temperature for both chambers.
It shall have provision for measuring primary & secondary chamber temperatures using external
thermo coupler.
Secondary chamber gas residence time shall be minimum 1 second at 1050 oC.
Primary Chamber:
Type: Static Solid Hearth
Material of Construction: Mild Steel, 5mm thick
Refractory thickness: approx.115mm thick
Material: Refractory bricks confirming to international standard.
Temperature resistance: 1400 oC
Insulation thickness: approx.115mm thick
Material: Insulation bricks confirming to international standard.
Waste Charging: Manual & Automatic waste charging.
Ash Removal: Manual/automatic
Secondary Chamber:
Type : Static Solid Hearth
Material of Construction: Mild Steel, 5mm thick
Refractory thickness: approx.115mm thick
Material: Refractory bricks confirming to international standard.
Temperature resistance: 1400 oC.
Insulation thickness: approx.115mm
Material: Insulation bricks confirming to international standard.
Waste Charging: Manual & Automatic waste charging.
Emergency Stack:
Type: cylindrical, top mounted on venturi ejector.
Material of Construction: Mild Steel, 3mm thick.
Refractory: 75mm thick castable.
Insulation: 25mm thick castable.
Quencher:
Material of construction of outer body: Mild Steel refractory lined from inside.
Shall have water circulation system with centrifugal pump.
It shall have to reduce flue gas temperature before venturi scrubber.
Shall provide pump motor of suitable capacity.
Air Pollution Control Device – Venturi Scrubber
Type: High pressure jet type.
MOC: Stainless steel – 316L.
Temperature at the outlet: 78-80 oC
Scrubbing Media: Water with 5% caustic
Re- Circulation Pump for Venturi Scrubber
Type: Centrifugal
Application: PP/SS
Piping : PPR
Droplet Separator & Re-Circulation Tank (Integral)
Type: Cyclonic
Application: To separate water droplets from flue gases
Material of Construction: Mild Steel Rubber lined 3mm thick
I.D. Fan:
Type: High pressure centrifugal
Material of Construction: Stainless steel 304, impeller and mild steel rubber lined casting
Drive: Bel
Combustion Fan:
Type: Centrifugal
Modulation: Manual damper control
Material of Construction: Mild Steel
Drive: Direct drive
Burners:
No. of burners: 2 Nos. (1 No. in Primary Chamber and 1No. in Secondary Chamber)
Type: Monoblock fully automatic
Fuel: Diesel
Fuel Oil Storage Tank:
Shall provide suitable capacity of oil storage tank.
Material of Construction: Mild steel.
Facility for visual checking of fuel shall be there.
It shall have diesel consumption monitoring system.
It shall come with diesel oil level indicator, piping with valves & N.R. valve.
Control Panel:
Type: Manual & Automated PLC based control panel with printer & recording device.
Material of Construction: CRCA sheet
It shall have digital temperature controller.
Epoxy powder coated washable paint finish.
It shall have audio-visual alarm system.
Chimney of 30 meters Height:
Material of Construction: Mild Steel
It shall be self-supporting type.
Height shall be 30 meters from ground level.
Paint The chimney is painted externally with two coats of heat resistant aluminum paint
Shall provide ladder till the top.
It shall have 3mm thick rubber lining from inside for protection.
It shall come with aviation lamp, lightening arrestor, stack, drain, inspection platform, sampling
port.
Consumption certificate:
The bidder must submit diesel consumption for a daily operation of 6 hours.
Turnkey:
Prices offered shall be inclusive of all civil works, electrical requirements including cabling and
switches required for installation & commissioning of the equipment.
Bidder shall submit detail drawings, design, and layout plan of civil works.
The bidder shall submit the details of BOQ of civil and electrical works.
Accessories, spares and consumables
All standard accessories, consumables and parts required to operate the equipment, including
all standard tools and cleaning and lubrication materials, to be included in the offer. Bidders
must specify the quantity of every item included in their offer (including items not specified
above).
Operating Environment
The system offered shall be designed to store and to operate normally under the conditions of
the purchaser’s country. The conditions include Power Supply, Climate, Temperature,
Humidity, etc.
Power supply: 220-240 VAC, 50Hz single phase/400 – 420 VAC, 50Hz three phase as
appropriate fitted with appropriate plug. The power cable must be at least 3 meter in length.
Standards and Safety Requirements
It shall have approval of “Pollution Control Board” of purchaser’s country.
All mandatory approvals required for the installation and operation of incinerator shall be done
by the bidder.
Must submit ISO 9001 AND
CE or USFDA approved product certificate.
User Training
Must provide user training (including how to use and maintain the equipment).
Warranty
Comprehensive warranty for 2 years after acceptance.
Maintenance Service during Warranty Period
During the warranty period supplier must ensure preventive maintenance along with
corrective/breakdown maintenance whenever required.
Installation and Commissioning
The bidder must arrange for the equipment to be installed and commissioned by certified or
qualified personnel; any prerequisites for installation to be communicated to the purchaser in
advance, in detail.
Documentation
User (Operating) manual in English.
Service (Technical / Maintenance) manual in English
List of important spare parts and accessories with their part number and costing.
Certificate of calibration and inspection from factory.

what’s Incinerators

Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more Incinerator chamber, the first chamber for waste and some time, there are 2 even if 3 first chamber(first chamber union) for waste. the senondary chamber for the gas/smoke from first chamber and the function for enviromental protection. the part is necessary because we not only burn the waste, but also for the result we burn the waste. for large capacity Incinerator, after the 1/2/3 combustion chambers, there are some part for emission treatment, this are not burning parts, they are only for smoke treatment. the function including Desulfurization, Deacidification, Ash remove, Defogging, Heat recovery, Production hot water, Hot gas for waste pre-dry, etc. at the end, the smoke will output in to environment.  

incinerators that can handle Bio-Medical waste red bag

incinerators that can handle Bio-Medical waste (red bag) from research laboratories with level 2 and 3, animal research, and hospitals.  There are also a small amount of Pharmaceutical waste to be destroyed.  I would like your recommendations on what incinerators would handle the these requirement based on the following monthly kilograms of material.

 

Site 1 – 4,650Kgs per month (I have recommend that I install two incinerators at this location since it is a medical research facility and the usage is very high)

 

Site 2 – 1000Kgs per month (this facility deals more with animal research but also has red bag waste from their research side, they currently have a large animal carouse incinerator)

 

Site 3 – 1000Kgs per month (this facility is a local hospital with bio-waste from treating patients)

About Medical Waste

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses.

Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed and destroyed in an appropriate manner. 
With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of small clinics to the more demanding and specialized requirements of large hospitals in their waste management processes.

HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.

Our products ensure efficient, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies , Drug Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.

○Middle-Small Capacity(TS Model)
※Main Features:
— Double Combustion Chamber
— Double Italy Burner
–Burning Rate: 10-100kgs per hour
–Combustion Chamber: 0.1M3-1.2M3
※Optional Function/Parts/Material/Burning Rate: 
— Stainless Steel Chimney 
— Dry Smoke Filter Chamber
— Chimney Height Custom Made
— Upgrade/Downgrade Burning Rate


○Large-Middle Capacity(YD Model)
※Main Feature:
–Three Combustion Chambers
— Double Italy Burner
–Burning Rate: 30-600kgs per hour
–Combustion Chamber: 0.36M3-5.5M3
※Optional Function/Parts/Material/Burning Rate: 
— Stainless Steel Chimney 
— Dry Smoke Filter Chamber
— Chimney Height Custom Made
— Semi-Automatic Waste Feeding
— 3-Section Wet Scrubber System
— Movable Platform Feeding Door
— Additional Burner
— Upgrade/Downgrade Burning Rate

● Service before and after Installation 
— Factory training for installation, operational and maintenance with free cost.
— Online service support for installation, operational and maintenance with free cost.
— Onsite installation, operational and maintenance training
— Onsite service support after installation

● Spare parts support
HICLOVER now offers spare parts including:
Burners (diesel oil, LPG or natural gas)
—   Element for burners
Fire ropes
Incinerator chamber maintenance materials
Air Fan 
Temperature element
—   Smoke filter brick
—  Control box
—  Other parts 

Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201    
Fax: +86-25-8461 0406

Website: www.hiclover.com  
Email:[email protected]
Email:    [email protected]  

500kg/day burn capacity incinerator

in acinerator with 300 kg/ hour by double filter wet and dry.Pet Dead Body Incinerator upto 80 kg ,gas operated is prefered. animal waste incinerator with capacity about 40Kgs. We will use this product to burn the animal corpses in normal way (not sick aninal).Could you please forward me quotation for incinerator that is suitable for service Town with a population of 200,000 people including other general town waste to burn. Technical specifications data sheet
List and quantities of consumables required per month
List and cost of all the spares required annually
List and costs of all the spares required in 5 yrs
List and costs of all the spares required in 10 yrs

2 incinerators one with 500kg/day burn capacity another one with 1000kg/day burn capacity

1 x Electrode

1 x Fuel Filter

1 x Photocell

1 x Flexible pipe

1 x Nozzle

1 x Control Box

ecologically friendly incinerator

50 bed hospital and would like to have your recommendation for incinerator that can effectively handle the load of 50 bed hospital.Incinerator for burnable garbage (paper & organic) medium capacity (100/150 lts). Bio Medical Waste Incinerators,

Capacity: 50kgs per hour Medical Waste Incinerator  Model  TS50 ( PLC ) with both option on Fuel ( Natural Gas and / or Diesel2 Burners
2 Temperature Thermocouple
5 meters for thermal gasket
1 incinerator control case
1 Blower ecologically friendly incinerator for burning polyproplylene bags we have 10 tons weekly

small scale incinerator of burning capacity

Poultry Incinerator – 400 kgs feed per day.a small scale incinerator of burning capacity 30kg/hr=1No. Note that it should be portable as this is meant for oil fields work on tented camps. Also it has to be diesel operated as our location is remote. 150!kg per hour LPG smokeless incinerator to be used at the international airport. This is a requirement bu the bio security that all international flights need all rubbish burnt within a set time.Required load capacity is 150Kg
Chamber – Primar 900 liters Secondary: 300Litres
Chimney 8M
Burning Rate: 50kgs/hr    Yes
Feed Capacity: 150kgs    Yes
Primary Combustion Chamber: 900 litres    Yes
Secondary Combustion Chamber: 300 litres    Yes
Mix Combustion Chamber: Yes    Yes
Smoke Filter Chamber: Yes    Yes
Feed Mode: Manual    Yes
Power: 0.7Kw    Yes
Fuel Type: Diesel Oil/ Natural Gas/LPG    Yes. Different Price if oil or gas fuel.
Internal Dimensions: 120 x 90 x 85cm (primary chamber)    Yes
External Dimensions: 200 x 160 x 310cm (without chimney)    Yes
Burning Efficiency: >98%    Yes

Incinerator capacity of destruction of 350 kg/hour

average daily slaughter is about 120 pigs. The Condemned material and byproducts from the abattoir for disposal is around 1000 kgs.daily
one line incinerator for the destruction of hazardous medical waste.

– Incinerator capacity of destruction of 350 kg/hour, calorific value of waste will be 13-25 MJ/kg

[3,500 kcal/kg] and maximum heat capacity 1,225,000 kcal/hr.

– Incinerator destruction capacity will be 8.4 tons/day and operation time will be 24 hr./day.

– Waste will be through automatic feeding system into the incinerator.

-The temperature will modulated in varying flow and percentage in oxygen, combustion gas is re-burned

in the re-combustion[secondary] chamber at a temperature of minimum 1,100 C during 2 seconds.

– Control panel will be fitted with a functional synoptic view showing the operating situation of the whole

incinerator and controlled by DCS/PLC system.

– Gas treatment system will respect the EE standard [Directive 2000/76/EC-4/12/2000.

– TOC of slag and bottom ashes will be less 3% of the dry weight.

– Installation will be completely free from visible smoke.

– Incinerator will be designed as a Packaged unit, having electrical connection pre-wired and final pipes

in place.

– Incinerator will have automatic de-ashing system with upward direction.

– Incinerator will have flue gas treatment system inclusive [emergency by-pass stack, gas cooling system,

two reactors and particulates filtering system] and guarantee of emissions out of incinerator.

– Training of AKU staffs at site.

– Site may be inspected and examine existing ATI machine, capacity 150 kg/hr.in 24 hour operation.

– Existing infrastructure space is available in basement, 100’ Length  x 30’ wide x 20’ Height for 2nd Incinerator.

– Existing chimney length is 12 meter, and width is 24”dia.

factory installed Diesel Fired Incinerator

Estimados, agradecería una cotización por los hornos crematorios para mascotas modelo YD-30 / YD-50.Mobile Diesel Fired  Incinerator model
supplied with the following specifications:
complete with constant ventilation fans for extraction,
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model plan to build a incinerator plant with 3 units of incinerators at the capacity of 500kg per hour each.
Together with other facilities like operation office, store, space to clean waste containers and 3-4 worker living quarters.
Necesito saber
1.ficha tecnida
2.guía mecanica
3.elevaciones
4. Los quemadores son Ecologicos.??  5.’caracteristicas generales
Del YD 50  and. YD 100  Long Life pet crematory
in Diesel ….Me interesa este producto  Long Life Pet Crematory (YD-50), y quiero conocer más detalles sobre:
Dame la lista de precios exactos por favor.
Me gustaría pedir algunas muestras. ¿Podría  enviarme la lista de precios de muestras?Raw Medical Waste Incinerators. Can you please provide an official cost quote for purchase of (2) incinerators, whichever model has a comparable Capacity = 30 kg/hr.