Mine Spews Toxic Fumes: NWT Air Regulations Not in Place

Snap Lake Mine, 220 kilometres northeast of Yellowknife, where elevated levels of dioxins and furans were pumped into the air. | Photo Fire Prevention Services

Last July, two incinerators at De Beers’ Snap Lake Mine were belching out clouds of black smoke, one sending an average of 65 times the accepted national limit of cancer-causing toxins into the air.

The hugely elevated levels of dioxins and furans — released when plastic is burned or garbage is not fully incinerated — were recorded during a four-day “stack test.” According to the World Health Organization, “dioxins are highly toxic and can cause reproductive and developmental problems, damage the immune system, interfere with hormones and also cause cancer.” The Canada-Wide Standards recommends emission levels for dioxins and furans not exceed 80 picograms per cubic metre. The company contracted to do the testing at Snap Lake found that one of the mine’s incinerators was emitting 6.5 times the acceptable limit, while the other incinerator was emitting a whopping 65 times the acceptable limit (5,220 picograms per cubic metre on average, as

emission

 

It’s unclear how long this was going on for, though the report noted the problem was clearly visible: “Black opaque smoke was noted for all tests early in the incineration cycle.”

De Beers did not respond to EDGE’s request for an interview by the time of publication. However, according to a letter from De Beers’ Environment and Permitting Superintendent, Alexandra Hood, sent to the GNWT and Environment Canada in January, the root cause of the problem was “not following standardized work practices,” and running the incinerators, which were only installed in 2013, at too low a temperature.

Since flunking the test, De Beers has retrained staff, rewritten operating procedures and brought in new policy to shut down the incinerators if they’re not meeting the correct temperatures (if it’s safe to do so), according to Hood’s letter. An inspection of the Snap Lake incinerators by a GNWT Lands Officer in March suggests De Beers has ameliorated the problem, at least in part: “No concerns were noted during this inspection,” it states, and “the west incinerator which was burning waste at the time of inspection was emitting clear exhaust gas with no black smoke coming from the stack.”

Whether or not sufficient steps have been taken, however, won’t be known for years: the next stack test is not scheduled until 2019, according to a source close to the issue wishing to remain anonymous.

No GNWT regulation

The fact that, for an undetermined period of time around July 2014, the Snap Lake incinerators were pumping out unacceptable levels of toxic emissions is troublesome in itself. But it points to a much larger problem in the territory; the GNWT does not regulate emissions, require companies to meet the CWS, or mandate stack testing. (The Mackenzie Valley Land and Water Board, likewise, does not regulate air emissions.)

At several points in her letter, Hood notes the lack of regulation, claiming De Beers “will conform with any regulatory requirements regarding incinerator stack testing once enabling legislation is developed and approved in the NWT.”

Without legislation in place, there is nothing to force De Beers or other groups using incinerators (i.e. every single mine in the territory), to keep their emissions at a safe level or undertake stack testing on a regular basis. Each mine has an Air Quality and Emissions Management Plan as part of its environmental agreement, but these plans only dictate reporting requirements, not actual emission targets. And while Hood claims “deficiencies, as measured against the Canada Wide Standards, will be managed through adaptive management and continuous improvement by De Beers,” there’s little government oversight of this “continuous improvement” and no fines or other mechanisms to force polluting companies to remedy their ways.

This problem has been going on for years. According to a Canadian Press report from 2011, the scientific journal Integrated Environmental Assessment and Management found sediments in a lake near the Ekati Mine that had levels of dioxins and furans 10 times higher than those collected from an uncontaminated lake. The same report cited a 2007 study commissioned by Environment Canada which suggested “extensive, uncontrolled burning of wastes could result in substantial accumulations of dioxins and furans in the local ecosystem, some of which will persist for some 8½ years at levels approaching those considered to be of toxicological concern.”

“In most cases we’re below the level that health agencies would (watch) for…” the study continues, “but we’re getting there. And if you have more incinerators and more burning, you may well exceed those levels.”

The GNWT’s Department of Environment and Natural resources did not return EDGE’s request for comment on the lack of regulation.

Why no regulation?

Back in 2001, the GNWT did sign on to the Canada-Wide Standards of dioxins and furans with all other provinces and territories (except Quebec) as part of a national Accord on Environmental Harmonization.

The document says: “Parties are required to take measures to reduce total releases from anthropogenic sources of dioxins, furans… with the goal of their continuing minimization and where feasible (technically and socio-economically), ultimate elimination.” However, it adds, “each jurisdiction will determine the exact means of ensuring compliance” – basically defanging the document by letting provinces and territories renege on their commitment with no repercussions.

Other jurisdictions have taken proactive steps, bringing in legislation to regulate emissions in line with the CWS. The GNWT has not. They did bring in guidelines for managing biomedical waste in 2005, but they have been unwilling to regulate incinerators at mine sites. Their reason? The “waste incinerators operating at remote industrial sites within the NWT… are located on federal crown land and are not regulated by the Government of the Northwest Territories,” says a report from 2009.

This may have been true in 2009, but post-devolution it’s no longer the case. Since April of last year, the mines are on land managed by the GNWT, yet there have been no moves from legislators to start regulating toxic emissions from mine or other industrial incinerators. The last time the issue was discussed in the legislative assembly in 2011, Weledeh MLA Bob Bromley said a “loophole in environmental rules is allowing a growing number of unregulated waste incinerators to release extremely toxic chemicals into the land and water.” He suggested, “when we take on new powers, we must be ready to move with new law.”

Devolution has come, and incinerators are still operating in an unregulated environment. With all the talk of fracking and opening up new mining projects in the territory, it’s now time, more than ever, for the GNWT to get its act together.

 

from: https://edgeyk.com/article/mine-spews-toxic-fumes-nwt-air-regulations-not-in-place/

 

Horizontal Solid Rubbish Incinerator

Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Key Features: 
* All models with Dual combustion chamber. *according to order 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane for Intelligent operation. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown area. Presently, incinerator line products market cover former Soviet Union area, Africa countries, Asia countries and middle east area.
From year 2010, we negotiated with updated technology from Europe and America manufacturers and establish cooperation relationship in the territory of China market. Unfortunately, poultry cremation equipment, poultry incinerator china, poultry incinerator in italy, poultry incinerators, poultry incinerators manufacturers, competition in other countries market, country discrimination and worries of intellectual property rights cause failure finally. Presently, we investment more effort, funds and technology development in our own brand, we are to be one of the largest incineration equipment in the world. We have trading branch company for professional export business service.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator A2400

Basic Info.

Model NO.:A2400
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, medical waste incinerators manufactures and suppliers, medical waste incinerators vs animal crematory, medical waste incinrators in china, medical waste italy, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420< /td>

320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree

Incinerator

Basic Info.

for Animal:Incinerator
Dosage Form:Incinerator
Type:Incinerator
Function:Incinerator
Export Markets:Global

Additional Info.

Trademark:CLOVER MEDICAL

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

We are one of the largest waste incinerator manufacturer and exporter of China. Pyrolytic incinerator technical is main waste treatment method all over the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid waste. Presently, we supply small clover incineration, clover incinerator 500, clover incinerator co., ltd., clover incinerator ltd, clover incinerator manufacturers in china, clover incineratorsand large scale incinerators as local customer requirements and design updated incinerator with our leading technology. 
Nanjing Clover Medical Technology Co., Ltd. Tel: +86-25-8461 0201 Fax: +86-25-8461 0406 Add: RM. 7411, No. 58 Yunjin Rd., Nanjing, China 210019

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Diesel Oil Fired Medical Waste Incenerator 50kg/Hr

Basic Info.

Model NO.:dioxine emission control medical hospital inciner
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Building a smoke free incinerator, burn capacity incinerator for 30 person, burn medical waste in an animal crematory, burn rate incinerator, burner capacity 126000 kcal/h, Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock.

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

SWRHA chairman: Delay in payment causes medical waste back-up

Chairman of the South West Regional Health Authority (SWRHA) Dr Lackram Bodoe said a back-up of medical waste at the San Fernando General Hospital had to do with a delay in payment to a contractor and not the malfunctioning of the incinerator.

Responding to complaints about the dangers posed by the accumulated medical waste, which included amputated limbs, needles, and bloodstained items, Bodoe assured that the $9 million incinerator installed last year was functioning well.

He said it was allowed to accumulate because daily paid workers refused to work on Tuesday.

Speaking with members of the media at SWRHA’s symposium on leadership at the Southern Academy of Performing Arts on Wednesday, Bodoe said:

“I want to give the assurance that the incinerator itself is working well.

“It is a new incinerator that was installed last year and the issue had to do with a contractor who was supposed to remove the garbage and there was a delay of funding and that is what created a temporary situation yesterday.”

Asked how soon the situation will be rectified, he said: “I have just been given the assurance by the CEO that the matter is being dealt with as we speak, so I expect by the end of the day it will be sorted out.”

In addition, Bodoe said the SWRHA was also considering introducing a new type of technology, called the radio wave technology for incineration, which was much more atmosphere friendly.

However, a Public Service Association representative, who wished to remain anonymous, said the incinerator had been breaking down on a regular basis since it was installed last year and was not working at this time.

“They even had to revert to the old incinerator and that is unsafe and unhealthy to people operating that incinerator. Since last week Thursday the incinerator (new one) is down,” he added.

He said workers took the action on Tuesday because since last week they were assured that the garbage problem would have been sorted out.

from: http://www.guardian.co.tt/news/2015-06-19/swrha-chairman-delay-payment-causes-medical-waste-back

Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door

Model

A1500

Internal Dimensions

150 x 100 x 96cm

Suit for Animal

Cat – yes

Dog – yes

Pig – small

Cow – small

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 03 sets

Oil Tank (if oil fuel): 500Liters

Design for Pets Cremation Business

Movable platform & Auto. Door & Fire/Flame Checking Hole

Independent Position for Small Pet





















HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28

Biomedical Waste Incinerator

Basic Info.

Model NO.:aravali incinerator of 30 kg per hour capacity co
Power Source:Diesel
Type:Incinerator
Usage:Incinerator
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. China medical waste, china medical waste incinerator manufacturer, china medical waste incinerators, china msw incinerator, china pet chamber, china pet cremation, Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 
Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock.

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Incinerators

Basic Info.

Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, animal waste to be cremated, animal, medical and waste incineration, animal, medical and waste incinerators, animalcrematory. COM, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Animal Waste Incinerator

Basic Info.

Model NO.:animal pet incinerator for sales
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Calculating capacity for incinerator, calculation of capacity of incinerator, capacities medical waste incinerators, capacity 30 kgs, capacity 300kg hour, Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 
Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES