Tag: hospital waste management

Hazardous situation: Incinerators at K-P’s major hospitals out of order



PESHAWAR:
Even with clear rules which state hospital waste must be incinerated within 24 hours of its collection, incinerators at two major hospitals in Khyber-Pakhtunkhwa (K-P) are out of order and the waste is dumped outside the hospitals.

According to data collected by the Environmental Protection Agency (EPA), 15 to 20 tons of hospital waste is generated daily in the provincial capital alone. Almost half of the total waste is recycled while the rest is collected by the Peshawar Development Authority (PDA).

LRH

“To be honest, we have one incinerator which is not in proper working condition and hardly disposes a quarter of the total waste generated,” said an official at Lady Reading Hospital while requesting anonymity. “But we have a new incinerator which will soon be functional.”

The official, who did not know the exact figure of the waste generated, said LRH has been among the well-equipped hospitals across the country. It has over 5,000 people (at least 3,000 in outpatient and 2,000 in accident and emergency departments) from across the province on a daily basis.

“The incinerator under process has some issues as a few of its parts are yet to be obtained,” said the official. “It also needs sufficient gas—another major problem—but we are in contact with Sui Northern Gas Pipeline Limited (SNGPL).”

The LRH official added the supply of gas to the hospital is not enough for sterilisation. He said the hospital administration is in contact with SNGPL authorities and the issue will soon be resolved.

HMC

Hayatabad Medical Complex (HMC) Chief Executive Dr Mumtaz Marwat said the incinerator at HMC is out of order but it does burn some waste. “The leftover is collected by the PDA and the hospital administration has approved Rs0.4million for a new incinerator, which will soon be installed.”

Khyber Teaching Hospital (KTH) Chief Executive Dr Inayat Shah Roghani said the incinerator at KTH was working properly and recycles over 200 kilogrammes of waste per hour.

“Along with the solid waste generated by KTH, we also recycle waste that comes from a few private hospitals in University Town,” said Roghani.

The EPA has already sent a written notice to the health directorate, asking it to properly dispose of medical waste as mentioned under Hospital Waste Management Rules 2005. These say the responsibility of waste management lies solely with the institute that generated it.

What happens next

Even if the incinerators at these hospitals are repaired, the problem of unattended dump is likely to persist. This is mostly because of the small private health centres which lack the basic knowledge and dispose of their waste as ‘municipal waste’. The ever-increasing number of such centres is directly proportional to the waste generated, making it a threat for the environment as at times the waste is just left in a pile or buried to groundwater.



Newsletter – medical waste

Newsletter – medical waste

Google
medical waste
Medical Waste Incinerators 2020年6月29日
www.imcha.net
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-13813931455(WhatsApp)
Website: www.hiclover.com
Add: Gangjia Zhihui Industrial Area, Xin Gangwan Rd. Liuhe, Nanjing, China 211500
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
… SBA services/ rapid diagnostic tests (RDTS) and rehabilitation /revamping of remaining BHUs, Roll out Hospital waste management regime at DHQs …
Facebook Twitter 标记为不相关
查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Newsletter
|
RSS 以RSS Feed的形式接收此快讯
发送反馈

 

Newsletter – medical waste

Newsletter – medical waste

Google
medical waste
Medical Waste Incinerators 2020年6月26日
www.imcha.net
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-13813931455(WhatsApp)
Website: www.hiclover.com
Add: Gangjia Zhihui Industrial Area, Xin Gangwan Rd. Liuhe, Nanjing, China 211500
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Top Key Vendors of this Market are: Stericycle, Republic Services, Daniels Sharpsmart, Sharps Compliance, ATI, Veolia Environnement, Medical Waste …
Facebook Twitter 标记为不相关
Pharmaceutical Waste Disposal & Management Market Status and Prospect (2015-2027) – Major Key Players Analysis, COVID-19 After Effects Analysis …
Facebook Twitter 标记为不相关
… report, medical waste delivery, in addition to several other functions using natural voice communication, facial recognition and hospital navigation.
Facebook Twitter 标记为不相关
Impact of Covid-19 on Pharmaceutics and Novel Drug Delivery Systems Market, Future Growth 2020-2024 , Amgen, Teva, Roche, UCB (Union …
Facebook Twitter 标记为不相关
查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Newsletter
|
RSS 以RSS Feed的形式接收此快讯
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-13813931455(WhatsApp)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Add: Gangjia Zhihui Industrial Area, Xin Gangwan Rd. Liuhe, Nanjing, China 211500
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
发送反馈

 

Newsletter – medical waste

Newsletter – medical waste

Google
medical waste
Medical Waste Incinerators 2020年6月9日
www.imcha.net
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-13813931455(WhatsApp)
Website: www.hiclover.com
Add: Gangjia Zhihui Industrial Area, Xin Gangwan Rd. Liuhe, Nanjing, China 211500
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Hospital Waste Management Market research is an intelligence report with meticulous efforts undertaken to study the right and valuable information.
Facebook Twitter 标记为不相关
Legal notice served for medical waste management. FE Online Report | Published: June 09, 2020 22:31:06. Legal …
Facebook Twitter 标记为不相关
The Medical Waste Management Market, By Type of Waste (Hazardous Waste, Non-Hazardous Waste), Service Type (Collection, Transportation,…
Facebook Twitter 标记为不相关
… an autoclave for sterilizing materials and for treating biomedical waste is fast, … Autoclaves are commonly used in laboratories and medical facilities.
Facebook Twitter 标记为不相关
查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Newsletter
|
RSS 以RSS Feed的形式接收此快讯
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-13813931455(WhatsApp)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Add: Gangjia Zhihui Industrial Area, Xin Gangwan Rd. Liuhe, Nanjing, China 211500
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
发送反馈

 

Steps of waste management



Item

Specification

Model

A1500

Internal Dimensions

150 x 100 x 96cm

Suit for Animal

Cat – yes

Dog – yes

Pig – yes

Cow – Little

Main Product List

Main Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Wet Scrubber( Washing Tower)

 

Incinerator Control Case

 

Chimney:10.0Meters *(Update to Stainless Steel, free Price )

 

Italy oil burner: 03 sets

 


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Oil Tank: 500Liters

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

hospital waste management ppt 2018


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm


brick incinerator design,The control system shall include an electronic performance monitoring and logging system. The system shall be capable of monitoring and logging chamber temperatures at regular intervals (not less than once per minute, with the capacity to vary the logging frequency). The system shall include the capacity to download the performance data by USB connection.
All the measuring devices attached with the incinerator should have digital display and should have provision of connecting to the recording system, which should include fuel meter and separate energy meter.
The temperature shall be determined against the inside wall of the combustion chambers. An audible and visible alarm shall be installed to warn the operator when the secondary temperature drops to below the required temperature.
The primary chamber must meet or exceed the following criteria:
“• Heavy steel construction.
• Fixed hearth geometry and starved air gasification operational mode. 
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. 
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. 
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints.
• Multiple electric ignition fuel burners designed to use automotive diesel fuel.
• Flame of the primary burner shall be oriented towards the center of the unit which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame. 
• The unit shall prevent leakage of the hot flue gas and any backfire. 
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• Digital thermometers connected to electronic dataloggers. The thermometers shall be located on the chamber walls away from the fuel burner.
• A differential air pressure gauge connected to an electronic datalogger

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

450x210x300cm