Tag: English

Specification of Setup and Comissioning of Waste Inci

Basic Info.

Model NO.:small scale incineratorssmall scale incinerators
Export Markets:Global

Product Description

Incinerator is a incineration gear, direct fire waste by gas fuel or oi fuel. As distinct circumscription, incinerator may be termed many words as under: 

Treatment ability: Small scale incinerator, big scale incinerator and incineration pant.  All over the world, in most countries, people anti incinerator since the incinerator will create a large Dioxin from the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical cremation equipment for medical waste makers, cremator 50 kg / h, crematorium gear, crematory manufacturer, lifeless animal incineration, lifeless creature incinerator, structures and biological traits. Dioxins can be released into the environment through woods fires, backyard burning of garbage, particular industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made resources still exist from the environment. Anyhow, we must remind this, that is big scale incineration pant, generally more than 30 ton per day. This is a societal issue, to examine and suggest ways in different angles in the public, government, economic development, environmental protection, technology advancement, etc. 

So, why people still use incinerator?  Pyrolytic technology can kill the virus, pollution management.  Second, for individual body, pet creature, in most countries and regions, we want to cremation them. This is the service in the process of society development, and ceremonies to commemorate the disappearance of existence. 

As previously two rationale but not just above, we nevertheless utilize incinerators. 

the way you are able to find reasonable incinerator for your regional website?  Incinerator is not a inexpensive equipment, generally the little scale model’s cost around $5, 000USD per unit and big scale model’s cost more than $50, 000USD each unit. So, before buy one unit incinerator, you need to make clear after things: A, burn out what? Incinerator is a incineration gear, function is fire waste. So what sort of waste that you want to treatment?  B, little or big? This based on the waste output every day or the waste volume per feed time, like creature size.  Incinerator use gas or oil fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than petroleum gas version. But some neighborhood website don’t have gas supply system.  And other tech products, such as electricity (220V, 380V), waste feed doorway kind, incinerator structure, etc..

After you describe these, you can go to find a local or global manufacturers, asking prices, technical specifications and finally purchasing the ideal products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Hospital Incinerator Design

Product Description

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerators differ from the Easier methods of open burning

Incinerators differ from the easier methods of burning as the operator has a greater degree of control over the burning procedure. The consequent higher temperatures, more holding times and increased turbulence lead to more complete combustion of the waste. Although a wider variety of wastes can be destroyed using high fever single or dual-chambered incinerators, determined efforts should still be taken to reduce the amount and type of waste generated and to implement other changes which would lead to reductions in air emissions. Refer to section 3 for additional information proper waste management practices and also a listing of what waste can and cannot be incinerated.

The incinerator manufacturer’s operating instructions must be followed in any way times to guarantee equipped temperature, holding time and turbulence requirements are attained and to avoid harm to the facility. When working during winter , additional care must be taken because cold air introduced into the primary and secondary chambers may make it hard for ordinary operating temperatures to be attained. Operators must be suitably trained and qualified to operate the equipment under the normal and emergency conditions. Owners are strongly encouraged to consult manufacturers or other qualified individuals with experience before purchasing an incinerator. Additional guidance on the selection of incinerator technologies and their operational requirements can be obtained by speaking to Environment Canada’s Technical Document for Batch Waste Incineration.

The setup and operation of monitoring and control systems is critical for its proper and secure operation of any incinerator.  The design, installation, certification and operation of continuous emissions monitoring systems (CEMS) must comply with the principles explained in Environment Canada’s Protocols and Performance Specifications for Continuous Monitoring of Gaseous Emissions  from Thermal Power Generation. For incinerators working in Nunavut, key operational parameters must be monitored in any way times using online tools capable of continuously measuring the combustion process and stack emissions caliber. These tools should be equipped with audible and visible alarms and be online whenever the incinerator is in operation, including’start-up’ and’cool ‘ phases. Table 3 lists the monitoring and control system requirements.

Little Incinerator Delers in Ernakulam

Basic Info.

Model NO.:small incinerator medical waste manufacturer
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  *according to sequence * High fever, long lifetime of incinerator.  * Free or minimum installation on site.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  New Design for pet animal cremation business.  * One year guarantee on incinerator and parts in stock.

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *based on sequence * High fever, long lifetime of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 500kgs per hourto 6ton daily.  *based on order  * New Design for pet animal cremation enterprise.  * One year warranty on incinerator and components in stock. 

Items/Model TS50(PLC)
Picture  
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800degree–1000degree
2nd. Chamber Temperature 1000degree-1200degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Animal Carcass Incinerator

Basic Info.

Model NO.:animal by-products of the incineration plant sche
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * animal cremation equipments china, animal cremation incenators, animal cremation incinerator,  * High temperature, long lifetime of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton per day.  * animal cremation equipment cost, animal cremation gear sale  * PLC Control Plane. *according to order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Pet Cremation Incinerator Prices

Product Description

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime.  * High temperature, long lifetime of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 600kgs a hourto 10ton per day.  * PLC Control Plane for Intelligent operation.  * One year guarantee on incinerator and parts in stock.

Item Specification
Model TS50 PLC
Main Product List per 01 set Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost)
Italyoil/gas burner: 02 units
Oil Tank (if oil fuel): 100Liters

Small Medical Waste Incinerator

Basic Info.

Model NO.:small mobile veterinary incinerator 20 kg hour bur
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High fever, long lifetime of incinerator.  * Free or minimum installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  * New Design for pet animal cremation business.  * One year guarantee on incinerator and components in stock.  Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet biological incinerator costs, biological waste, biological aste equipements in china, biological waste incinirator, biological waste portable incinerator usa, Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Medical Waste Incineration Plant

Product Description

PLC( Programmable Logic Controller), Smart and Automated operation. Set combuston time according to different waste material and incinerator cease combustion itself.

Item Specification
Model TS50 PLC
Main Product List per 01 set Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost)
Italyoil/gas burner: 02 units
Oil Tank (if oil fuel): 100Liters

Price for Incineration for Pets Price of Running 100kg

Basic Info.

Model NO.:clover incinerator manufacturers in china
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd., local in Nanjing city, China.

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation