Medical Incinerator 10kg/Hour

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can use within this equipment?  A: This equipment for medical waste, pet creature, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste.  GB18484-2001.  The animal/pet combustion speed around 2/3 of ordinary capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is around 16 hours. The life of incinerator involving 5-10 year based on use. 

Generally, we proposition little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output capacity around 2kgs per individuals each day. If there are 200 sickbed in the clinic, that’s imply you need one incinerator capability around 400kgs per day, switch to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs each hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We supply all files and incinerators simple to installation and functionality. Customer can send individuals come to our factory to find out installation and operation. Small scale medical waste incinerator, syc-30 incinerator, waste incinerator manufacturer China, Generally, We do not send engineer to neighborhood website or even ask. The dispatch cost is extra based on order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi level.  The next combustion chamber: 1000-1200 centi level.  PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation cost based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD annually maintenance according version, use situation. 

One individual can service 02 device incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and understand threat of medical waste to protect worker self with essential protection element. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Waste Management Incinerator Technology

Basic Info.

Model NO.:incinerator manufacturers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can utilize within this gear?  A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid gas and waste waste.  GB18484-2001. 

Q: Remedy capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not indicate any waste material. The animal/pet combustion speed around 2/3 of ordinary power. 

Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to utilize. 

Generally, we proposal small lab, small clinic usage capability under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that’s imply you need one incinerator capability around 400kgs every day, switch to power per hour is approximately 30-40 kgs per hour. According the performance time every day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We supply all files and incinerators easy to installation and operation. Client can send individuals visit our factory to learn operation and installation. Generally, We do not send engineer to neighborhood website or even request. The dispatch price is additional according to order.  The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control case. PLC mode according to order and model. 

Q: Operation and maintenance costs  A: Operation price according to fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD per year maintenance according version, utilize situation. 

One individual can service 02 unit incinerators. Hospital incinerator manufacturers, incinerator burners, incinerator diesel burn, incinerator manufacturer china, incinerator medical waste maker, incinerator suppliers, The staff must have fundamental electrician comprehension to operate/inspect/maintaince incinerator/burner/blower according to surgery user guider, and know risk of medical waste to protect worker self with essential security component. 

Q: The Residency period in combustion chamber  A: 02 sec.

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinirator of Veterinary Hospital

Basic Info.

Model NO.:incinerators for hospitals from china
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can utilize within this gear?  A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any radiation and volatile substance, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001.  Incinerator price, incinerator price for 50kg/hr produced in china, incinerator manufacturers, incinerator small scale, incinerator suppliers in china, incinerator baths china, The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator utilize time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year based on utilize. 

Ordinarily, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per individuals every day. If there are 200 sickbed in the hospital, which ‘s mean you need 1 incinerator capacity around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the operation time every day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We supply all files and incinerators easy to installation and functionality. Client can send individuals visit our factory to find out operation and installation. Generally, We do not send engineer to local website if not request. The dispatch cost is extra based on order.  The next combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control instance. PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation cost based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according version, utilize situation. 

One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know threat of medical waste to protect worker self with essential protection component. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Medical Incinerator 10kg/Hour

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can utilize within this gear?  A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of ordinary power. 

Clover incinerator utilize time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is about 16 hours. The lifetime of incinerator involving 5-10 year according to utilize. 

Ordinarily, we proposal little laboratory, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, please compute the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capability around 400kgs every day, change to capability per hour is around 30-40 kgs per hour. 300 kg incinerator, animal cremation burners, animal incinerators china, china medical waste incinerator, china+incinerator, hospital incinerator manufacturer, According the performance time every day, waste material, budget, development, etc, you can use capacity from 30-50 kgs each hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We supply all documents and incinerators easy to setup and functionality. Customer can send individuals come to our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood site or even ask. The dispatch price is additional according to order. 

Q: Combustion Temperature  A: The very first combustion chamber: 800-1000 centi degree.  The next combustion chamber: 1000-1200 centi degree.  PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation price according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according version, utilize situation. 

One person can service 02 unit incinerators. The staff should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know threat of medical waste to safeguard worker self with essential protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Medical Waste Incinerators

Basic Info.

Model NO.:medical waste incinerator 300kg/time china
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can use in this gear?  A: This gear for medical waste, pet creature, Municipal waste, reside squander. Prohibit any volatile and radiation material, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of average power. 

Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time to get feeding squander. Laboratory incinerator china maker, big animal incinerators, low-cost medical waste incinerator, pet crematory, pet incinerator deisel, pet incinerators, Real combustion time per day is about 16 hours. The life of incinerator between 5-10 year based on use. 

Ordinarily, we proposition little lab, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, then please calculate the waste output capacity around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs every day, switch to power per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator.  *The best way to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing  A: We provide all files and incinerators simple to installation and functionality. Customer can send individuals visit our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood site if not request. The dispatch price is additional based on order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi degree.  The next combustion chamber: 1000-1200 centi degree.  PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation price based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD annually maintenance according model, use situation. 

One person can service 02 unit incinerators. The team should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower in accordance with operation user guider, and know risk of medical waste to safeguard worker self with mandatory security element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Animal Waste Incineration, Pet Cremation Equipment

Product Description

Waste Incinerator International Market Analytics  Date.

Keyword:  Small incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator manufacturers 

Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be named many words as below: 

Treatment ability: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator fuel: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  All around the world, in most countries, individuals anti incinerator because the incinerator will produce a large Dioxin from the smoke. Dioxins can be released to the environment through woods fires, backyard burning of garbage, certain industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both man-made and natural sources still exist from the environment. Anyhow, we have to remind that, this is large scale incineration pant, normally more than 30 ton every day. This is a social issue, to examine and suggest ways in different angles from the general public, government, economic development, environmental protection, technology advancement, etc. 

So, why we use incinerator?  First, for your medical waste in the hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control.  Secondly, 100 kg incinerator, 100 kg/hr incinerator, 100 kg/hr incinerator for hospital waste, 100 kgs incinerator, 100 kgs/hr, 100 per hour, 100 ton incinerators uses natural gas, for human anatomy, pet creature, in many countries and regions, we want to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As previously two reason but not only above, we still utilize incinerators. 

How you are able to find reasonable incinerator to your local website?  Incinerator isn’t a cheap equipment, normally the small scale model’s cost around $5, 000USD per unit and large scale model’s cost more than $50, 000USD per unit. So, before purchase one unit incinerator, you need to make clear after things: A, burn what? Incinerator is a incineration equipment, function is fire squander. So what kind of waste that you would like to treatment?  B, small or large? This according to the waste output every day or the waste quantity per feed time, like creature size.  C, fuel? Incinerator use gas or oil fuel, normally, gas fuel is cheaper than oil and the smoke cleaner than petroleum gas version. However, some neighborhood website don’t have gasoline supply system.  Along with other tech products, such as power(220V, 380V), waste feed doorway kind, incinerator construction, etc..

After you describe these, it is possible to go to find a local or global producers, asking prices, technical specifications and finally buying the ideal products. 

Wrote by Nicky

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

Little Capacity Incineratorsmall 20 Kg/Hour Medical Waste Inc

Basic Info.

Model NO.:Slaughterhouse Waste Incinerator
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may use within this gear?  A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time daily to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator involving 5-10 year according to use. 

Ordinarily, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s imply you need one incinerator capacity around 400kgs per day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all files and incinerators easy to installation and functionality. Customer can send people visit our factory to find out operation and installation. Generally, We do not send engineer to neighborhood website or even ask. The dispatch cost is extra according to order.  The next combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control instance. PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD per year maintenance according version, use situation. 

One individual can service 02 unit incinerators. Incinerators italy for medical waste, incinerators medical waste, incinirator, industrial incinerators china, insenorator, klarge garden incinerator, lab animal incinerator auction, The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to functionality consumer guider, and understand risk of medical waste to safeguard worker self with necessary security element. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Waste Incinerator

Product Description

Waste Incinerator International Market Analytics  Date.

Keyword:  Little incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator may be termed many words as under: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator fuel: Gas incinerator, oil incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is conventional waste treatment solution for many decades. All around the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin from the smoke. Smart ash cost, smartash incinerator cost, smokeless crematorium, sterilization by incineration, supplier waste incineration china, syc 30 inciner, syc hospital, Dioxins can be released into the environment through forest firesand backyard burning of garbage, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both natural and man-made sources still exist from the surroundings. Anyhow, we have to remind that, this is big scale incineration pant, generally greater than 30 ton per day. This is a social issue, to examine and propose ways in different angles in the general public, government, economic development, environmental protection, technology advancement, etc. 

So, why we use incinerator?  First, for the medical waste in the hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management.  Second, for human body, pet creature, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two rationale although not just above, we nevertheless utilize incinerators. 

How you can find reasonable incinerator to your local site?  Incinerator is not a inexpensive equipment, generally the small scale version ‘s cost around $5, 000USD per unit and big scale version ‘s cost more than $50, 000USD each unit. Thus, before purchase one unit incinerator, you have to make clear following items: A, burn out what? Incinerator is a incineration equipment, function is flame waste. So what sort of waste that you would like to cure?  B, small or big? This according to the waste output every day or the waste quantity per feed time, like creature size.  C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than oil gas version. But some neighborhood site don’t have gasoline distribution system.  Along with other tech items, like power(220V, 380V), waste feed door type, incinerator structure, etc. 

Once you clarify these, it is possible to go to find a local or global manufacturers, asking prices, technical specifications and finally purchasing the ideal products. 

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

Wrote by Nicky

Medical Waste Incinerators Medical Waste Incinerators

Basic Info.

Model NO.:medical waste incinerators manufacturers china
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Waste Incinerator International Market Analytics  Date.

Key Word:  Small incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator manufacturers 

Incinerator is a incineration gear, direct fire squander by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be named many words as under: 

Treatment ability: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, individual cremators  Incinerator fuel: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.  Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment solution for several years. All over the world, in most countries, people anti incinerator because the incinerator will produce a large Dioxin from the smoke. Dioxins can be released into the environment through woods fires, backyard burning of trash, certain industrial activities, 150kg/hr incinerator, 150kg/hr incinerator china, 20 kgs incinerator, 20kg capacity incinerator, 300 kg creature, 300kg capacity incinerator medical waste, 300kgs per hour incinerator, and residue from past business burning of waste. Dioxins break down very slowly and past releases of dioxins from the natural and man-made sources still exist from the surroundings. Anyhow, we must remind this, that is large scale incineration pant, normally greater than 30 ton each day. This is a social issue, to examine and suggest ways in different angles in the public, government, economic development, environmental protection, technology development, etc. 

So, why people use incinerator?  To begin with, for your medical waste from hospital, the pyrolytic incinerators is greatest treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Secondly, for individual body, pet creature, in most countries and regions, we want to cremation them. This is the service in the procedure for society development, and ceremonies to commemorate the disappearance of existence. 

As previously two reason but not just above, we still use incinerators. 

How you can discover reasonable incinerator for your local site?  Incinerator isn’t a cheap equipment, normally the little scale model’s cost around $5, 000USD per unit and large scale model’s cost more than $50, 000USD each unit. Thus, before buy one unit incinerator, you have to make clear following things: A, burn out what? Incinerator is a incineration gear, function is fire squander. So what sort of waste you want to cure?  B, little or large? This based on the waste output daily or the waste volume per feed time, like creature dimensions.  C, fuel? Incinerator use oil or gas fuel, normally, gas fuel is cheaper than oil and the smoke cleaner than petroleum fuel model. However, some local site don’t have gasoline supply system.  And other technology products, like power(220V, 380V), waste feed door type, incinerator construction, etc. 

Once you clarify these, you can go to discover a local or global producers, asking prices, technical specifications and finally purchasing the right products. 

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES

Wrote by Nicky

Animal Crematorium Incinerators Rated for 60 Pounds Per Hour

Product Description

Waste Incinerator International Market Analytics  Date.

Key Word:  Little incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi gas. As distinct circumscription, incinerator could be termed many words as under: 

Therapy ability: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator gas: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment solution for many years. All over the world, in most nations, people anti incinerator since the incinerator will produce a sizable Dioxin from the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins could be released to the environment through forest fires, backyard burning of garbage, certain industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made sources still exist from the environment. Anyhow, we have to remind this, that is large scale incineration pant, normally more than 30 ton daily. This is a social issue, to examine and indicate ways in different angles from the public, government, economic development, environmental protection, technology advancement, etc. 

So, why we still use incinerator?  First, for your medical waste in the hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Second, for human body, pet creature, in most nations and regions, we desire to cremation them. This is the ceremony in the procedure for society development, and ceremonies to commemorate the disappearance of existence. 

As previously two reason but not just above, we nevertheless use incinerators. 

the way you are able to find reasonable incinerator to your regional website?  Incinerator is not a cheap equipment, normally the little scale model’s price around $5, 000USD per unit and large scale model’s price more than $50, 000USD per unit. Thus, before purchase one unit incinerator, you need to make clear after items: A, burn what? Incinerator is a incineration gear, function is fire waste. So what kind of waste you would like to treatment?  B, little or large? This based on the waste output daily or the waste volume per feed period, like creature size.  Incinerator use gas or oil fuel, normally, syc-10 incinerator, thermal oxidiser maker, two chamber medical waste incinerator, waste incineration china, waste incineration furnace, waste incineration in china, gasoline fuel is cheaper than oil along with also the smoke cleaner than petroleum fuel model. However, some local website don’t have gasoline supply system.  Along with other technology items, like electricity (220V, 380V), waste feed doorway kind, incinerator construction, etc. 

After you clarify these, you can go to find a local or global producers, asking prices, technical specifications and finally purchasing the right products. 

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES