Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we small gas incinerators, small high efficiency incinerators, small hospital incinerators, small in lab incinerators, small incenerators, small incinerator business proposal, supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
The gas/oil burner of incinerator equipment — Nov. 26, 2011
We supply incinerator and also burners. Some model of incinerator use Italy original burner (gas or oil fuel) and some model use China original burner. Generally, incinerator with two burners but we can add one extra burner to improve combustion capacity.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| 2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, medical waste incinerator manufacturers of china, medical waste incinerator manufactures in usa, medical waste incinerator plc design, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
Application Scope:
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.
3. Community & Sea Port & Station: Municipal Solid Waste, etc.
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Nanjing Clover Medical Technology Co., Ltd.
Tel: +86-25-84610201
Fax: +86-25-84610406
Nanjing City, China
| Items/Model | TS100(PLC) |
| Burn Rate | 100 kg/hour |
| Feed Capacity | 200 kg |
| Control Mode | PLC |
| Combustion Chamber | 1200L |
| Internal Dimensions | 120x100x100cm |
| Secondary Chamber | 600L |
| Smoke Filter Chamber | Yes |
| Feed Mode | Manual |
| Voltage | 220V |
| Power | 0.7Kw |
| Oil Consumption (kg/hour) | 14–28 |
| Gas Consumption (m3/hour) | 10–32.2 |
| Temperature Monitor | Yes |
| Temperature Protection | Yes |
| Oil Tank | 200L |
| Feed Door | 80x60cm |
| Chimney | 10Meter |
| Chimney Type | Stainless Steel |
| 1st. Chamber Temperature | 800–1000 degree |
| 2nd. Chamber Temperature | 1000-1200 degree |
| Residency Time | 2.0 Sec. |
| Gross Weight | 6000kg |
| External Dimensions | 260x150x180cm |
Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. "Dioxins" refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, low cost plastic incinerator images, low-cost incinerator waste, LPG incinerator for sale, macau incinerator, madical waaste insinaraders nc, main parts of incinerator, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc.
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
| Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
| Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
| Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
| Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
| Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
| Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
| External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
| Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
| Oil Tank(Liters) | 50 | 100 | 100 | 150 |
| Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
| Chimney (M) | 5 | 5 | 5 | 5 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:
Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators
Incinerator fuel: Gas incinerator, oil incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
A Model animal crematory is latest design for animal cremation and other solid waste. This equipment quality structural for kinds of site, like hospital, environmental department, large scale municipal waste incinerator manufacturers in china, large scale of the use of incinerator, large scaled capacity incinerator, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.
| Items/Model | A360 | A600 | A900 | A1200 |
| Burning Rate *animal | 20 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 60 kgs/Hr. |
| Feed Capacity *animal | 30 kgs | 50 kgs | 80 kgs | 100 kgs |
| Equipment Weight | 2300 kgs | 3000 kgs | 4000 kgs | 4300 kgs |
| Primary Chamber (Liters) | 360 | 600 | 900 | 1200 |
| Secondary Chamber (Liters) | 200 | 200 | 300 | 500 |
| External Dimensions (cm) | 145x90x175 | 175 x 100 x 180 | 200x160x230 | 220x180x360 |
| Internal Dimensions (cm) | 100x60x60 | 130 x 70 x 65 | 120x90x85 | 130x100x90 |
| Oil Tank(Liters) | 200 | 200 | 300 | 300 |
| Door Opening (cm) | 48 x 60 | 50 x 60 | 62 x 80 | 55 x 80 |
| Chimney (M) | 5 | 5 | 5 | 10 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
| 1st. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| 2nd. Chmaber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., clover medical limited Saudi, clover medical limited yd-20c, clover medical. Net, clover-incinerator, clover+incinerator, up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
Application Scope:
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.
3. Community & Sea Port & Station: Municipal Solid Waste, etc.
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Nanjing Clover Medical Technology Co., Ltd.
Tel: +86-25-84610201
Fax: +86-25-84610406
Nanjing City, China
| Items/Model | TS10(PLC) |
| Burn Rate | 10 kg/hour |
| Feed Capacity | 20kg |
| Control Mode | PLC |
| Combustion Chamber | 100L |
| Internal Dimensions | 50x50x40cm |
| Secondary Chamber | 50L |
| Smoke Filter Chamber | Yes |
| Feed Mode | Manual |
| Voltage | 220V |
| Power | 0.5Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 |
| Gas Consumption (m3/hour) | 6.2–11.4 |
| Temperature Monitor | Yes |
| Temperature Protection | Yes |
| Oil Tank | 100L |
| Feed Door | 30x30cm |
| Chimney | 3Meter |
| Chimney Type | Stainless Steel |
| 1st. Chamber Temperature | 800degree–1000 degree |
| 2nd. Chamber Temperature | 1000degree-1200degree |
| Residency Time | 2.0 Sec. |
| Gross Weight | 1500kg |
| External Dimensions | 140x90x120cm |
Technology Respond(FAQ)
Q: What is kind of waste can use in this equipment?
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard
A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one waste incineration compaines in china, waste incineration equipment, waste incineration factory data, waste incineration in ukraine, waste incineration plant ipswich jobs, incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order.
Q: Combustion Temperature
A: The first combustion chamber: 800-1000 centi degree.
The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode
A: Default Control mode is common control case. PLC mode according to model and order.
Q: Operation and maintenance costs
A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| 2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic pet cremation manufacturer, pet cremation manufacturer english, pet cremation oven, pet cremation oven from china, pet cremation system, pet cremation system (syc-100) price, incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. To 600kgs/Hr., up to 10ton per day.
Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime.
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day.
* PLC Control Plane for Intelligent operation.
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
| Items/Model | TS20(PLC) |
| Burn Rate | 20 kg/hour |
| Feed Capacity | 40kg |
| Control Mode | PLC |
| Combustion Chamber | 210L |
| Internal Dimensions | 65x65x50cm |
| Secondary Chamber | 110L |
| Smoke Filter Chamber | Yes |
| Feed Mode | Manual |
| Voltage | 220V |
| Power | 0.5Kw |
| Oil Consumption (kg/hour) | 7.8–16.3 |
| Gas Consumption (m3/hour) | 8–15.7 |
| Temperature Monitor | Yes |
| Temperature Protection | Yes |
| Oil Tank | 100L |
| Feed Door | 45x40cm |
| Chimney | 3Meter |
| Chimney Type | Stainless Steel |
| 1st. Chamber Temperature | 800–1000 degree |
| 2nd. Chamber Temperature | 1000-1200degree |
| Residency Time | 2.0 Sec. |
| Gross Weight | 2200kg |
| External Dimensions | 160x110x130cm |
Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.
The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until incinerator usd, incinerator vietnam, incinerator waste, incinerator waste chamber, incinerator waste diesel, incinerator water filter, incinerator website, waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion.
Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell.
The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation.
In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree |
| 2nd. Chamber Temperature | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control.
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we still use incinerators.
How you can find reasonable incinerator for your local site?
Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's w2e pet, waste anathomics incinerator, waste burner china any fuel, waste clinic incinerator manufacturers, waste gas incinerator manufacturer, waste incineration, price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment?
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size.
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don't have gas supply system.
And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |