Archive: April 30, 2026

estilo incinerador para centros de salud

Incinerator for Animal Crematory Pig Farm Model A1200

Incinerator for Animal Crematory Pig Farm Model A1200


*** 3 sets Burners
*** Good for animals or big pets
*** Double Combustion chamber
*** stainless steel chimney
*** Italy made oil burners
*** 1200Liters(1.2m3) big chamber

Model

A1200

Picture

Burning Rate

Average 50 kgs/hour

Feed Capacity

Average 100 kgs/feeding

Primary Combustion Chamber

1200 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V/380V

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 34.4 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

130x100x90cm (primary chamber)

External Dimensions

220x180x360cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

55 x 80cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7500 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

Model

A1200

Internal Dimensions

130x100x90 cm

Suit for Animal

Cat – yes

Dog – yes

Pig – small

Cow – no

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber(Dry Scrubber)

Incinerator Control Case

Chimney:10.0Meters *(upgrade to Stainless Steel, free cost)

Italy oil burner: 03 sets

Oil Tank : 500Liters

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-11

Cheap Price Incinerator



Basic Info.

Type:Incinerators
Export Markets:Global

Additional Info.

Trademark:CLOVER CHINA

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a 600 degree incinerator, 70? 80 kgs / hour, 86 animals ltd co, a hospital medical waste incinerator 100kg, a hospital's incinerators, a2600 incinerator, adamant refractor for pet cremation, diversified company with technology development, manufacture, import and export, supply waste incinerators, medical equipment and other Environmental Protection Equipment. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incineradores de basura

Somos fabricantes de incineradores de China, proveedores de servicios y también exportadores. Tasa de limpieza del proveedor para el consumidor de incineradores, incinerador clínico de suministro, quemador de instalaciones médicas, incineradores de animales, quemadores de cerdos, equipo de cremación de animales, quemador pequeño, incinerador de perros, quemador de mascotas, incinerador portátil, incinerador de mascotas pequeñas, máquina de pirólisis de desechos contagiosos, quemador de laboratorio . HICLOVER ayuda al cliente a reducir el presupuesto de adquisición, características personalizadas, productos de alta calidad y un servicio agradable.Los mejores productores de incineradores, empresas de incineradores, incineradores de desechos comunitarios, quemadores de gas, incineradores de desechos biomédicos

durable and highly efficient incinerators with various capacities for hospital/medical waste, cremation and other solid waste treatments

Single and Dual Chamber Medical Incinerator.durable and highly efficient incinerators with various capacities for hospital/medical waste, cremation and other solid waste treatments.

 

Chamber Double

Burning Rate      10 kg per hour (for two incinerators)

Burning Rate     20 kg per hour (for three incinerators)

Loading   Method   Manual

No of Burners   Single for 10 kg/hour and Double for 20 kg per hour

Fuel                    Diesel and Natural Gas

Warm Up Time    Not more than 20 minutes

Temperature controller   Digital

Power Supply      Single Phase 220V

Chimney Height    20 feet from ground level

·         50kg per hour

·         Option for  medical waste.

Type
Single Chambered Cylindrical

Feed Material
Papers, Cartons wastes

Capacity
1000 Kg/Day

Burning Capacity
125 Kg/hr

Design Standards
Generally confirming to IS Standards

Type of burning operation
Zero Fuel System

Combustion Chamber

Type
Cylindrical

Dimension
1.25 m Dia (Approx) x 1.2 m Height (Approx)

Temperature
400 – 600 °C

MOC
Chrome Alloy Steel, inside lining with fire bricks/Ceramic Clay

Outer Lining
Thermal Proof Lining

STACK

Type
Self Supported

MOC
MS

Accessories
Port Hole and Ladder for emission testing with complete online scrubbing system, thermostat

The units will be used for our client camps in the field. These Camps range in manning size from 20 – 200 people. Each site has a medical clinic, a very small use for medical but will need it.

Smallest Waste Incineration Into Energy System



Basic Info.

Model NO.:small waste incinerator manufacturers
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, incinerator makers in china, incinerator manufacturer italy, incinerator manufacturer small, incinerator manufacturer usa msw, incinerator manufacturer vietnam, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Technical FAQ on HICLOVER Waste Incinerators: Engineering Reliability and Market Position

Technical FAQ on HICLOVER Waste Incinerators: Engineering Reliability and Market Position

Q1: What technical standards govern the operation and design of HICLOVER waste incinerators?

A1: HICLOVER waste incinerators adhere to rigorous industrial standards that ensure reliable combustion and strict regulatory compliance. From the outset, these systems are engineered with **containerized incinerator operation** principles that are complemented by **medical incinerator operating temperature standards** to meet both safety and operational demands. Engineered for a broad temperature range, these incinerators maintain high thermal retention necessary for the complete oxidation of waste material, thereby minimizing pollutant emissions. Detailed engineering specifications include dual combustion chambers for primary and secondary oxidation, which not only enhance combustion efficiency but also contribute significantly to carbon emission reduction pressure and ESG compliance in industrial waste management.
Engineering factors such as thermal stability, precise fuel combustion management, and integration of high-temperature sensors are pivotal. The design also meets strict guidelines referenced by global regulatory bodies like the WHO and EU emission frameworks, ensuring the safe disposal of hazardous waste. Structural components are designed to withstand extreme conditions, certifying that the incinerators are not only robust but consistent in performance. These standards play a critical role, particularly when addressing escalating global infectious disease preparedness and crisis zones & humanitarian camps where dependable waste management is paramount.

Q2: How does HICLOVER ensure compliance with global emission regulations and advanced combustion principles?

A2: HICLOVER utilizes a systematic approach to ensure its incineration systems fully comply with stringent global emission regulations and advanced combustion principles. The waste incinerators incorporate a dual-chamber design, where the first chamber initiates combustion and the second chamber ensures further oxidation, reducing the risk of residual toxins. This process is tightly managed by a PLC automation system, which monitors key parameters such as temperature, oxygen levels, and fuel consumption. These measures are in line with recognized international frameworks, including WHO guidelines and EU emission directives, ensuring that the incineration process operates within safe thermal operating margins.
Furthermore, the engineering design factors in both dry and wet scrubber options, allowing for adaptable exhaust purification that addresses diverse emission challenges. The integrated high-temperature retention in the combustion chamber is critical to meeting both industrial requirements and environmental mandates. For additional technical specifications or detailed system reviews, more information is available on the HICLOVER site at https://www.hiclover.com/. This comprehensive design strategy not only reinforces compliance with environmental regulations but also supports sustainable operational practices in sectors where decentralized waste management is becoming essential, particularly in remote mining or oil camps.

Q3: What are the advantages of HICLOVER’s incineration plant design for remote and crisis zone applications?

A3: HICLOVER’s incineration plant design is structured to offer a robust and adaptable solution for remote operations and crisis management contexts, including humanitarian camps and global infectious disease preparedness environments. The modular, containerized systems allow for rapid deployment and minimal on-site setup, which

diagrama de bloques del quemador

Nuestra variedad de quemadores cubren empresas relacionadas con la cremación de animales de rango pequeño a grande, como ranchos avícolas, ranchos de ganado, ranchos de ovejas, granjas de cerdos, establos, perreras, laboratorios de pruebas, criaderos, crematorios para perros.

El incinerador quema los desechos en la cámara de combustión primaria y vuelve a quemar el humo de la cámara de combustión primaria para asegurarse de que sea respetuoso con el medio ambiente, sin humo negro, sin olor, reduzca la infección por bacterias patógenas.incinerador de residuos sólidos, incineradores en venta, incinerador industrial, incinerador

Soluciones de sistema para el medio ambiente de desechos clínicos, que consisten en incineración de desechos, terapia de descarga de humo, saneamiento a alta temperatura, luz de saneamiento ultravioleta, trituradora de desechos, destructor de agujas, paquete de desechos médicos, contenedores afilados, etc.

Medical Waste Incinerator of 20 kg/hr capacity with dual burner

3 Medical Waste Incinerator of 20 kg/hr capacity with dual burner.Medical Waste Incineration Systems. i’m interested to destroy about 200 kg remains. a Medical Incinerator project for Tehran municipality. Our purpose for this project is to establish a plant in order to incinerate Medical waste with 50 ton/day capacity. a incinerator with 100 kg / hour burning capacity. And it should work on diesel fuel, 2 chamber. Waste management
Incinerator
*External diameter at base 6ft 1.8m
*External diameter at top 4 1/2ft 1.35m
*Internal diameter at base 3ft 0.9m
*Internal diameter at top 3ft 0.9m
*Thickness of wall at base 18cm
*Thickness of wall at top 9cm
*Perpendicular height of wall 4ft
*Height of Iron bars from grate above ground 1ft

Material Required
*Puddle swish
*5 or 6 Iron bars about 4 1/2ft 1.35m long each
*Quantity of large stones for foundation
*2 empty kerosene tins for making vent holes
*2ltrs of coal tar
*2 brushes
*Foundation 1ft-1 1/2ft deep is dug
*Filled with large stones and puddle swish to ground level
*Empty kero tins are next placed into position where the vent holes are to appear
*Wall 1ft high is built with puddle swish
*Iron bars are put in position leaving a space of about 2cm-3cm between the bars 4ft 1.2m to be reached
*Wall plastered smooth.Incinération à haute température pour la destruction complète des déchets contaminés ou dangereux.
Principe de combustion pyrolytique avec brûlage des fumées dans une chambre de post-combustion
Incinérateur double chambre 900°C/1200°C de capacité 30 kg.
Equipé de : 1 brûleur de combustion + 1 brûleur de re-combustion + 1 laveur de fumées. Capacité de destruction horaire
En poids : au moins 30 kg
En volume : au moins 200 litres
Température :
Combustion : 900°C
Post combustion : 1200°C
Puissance des brûleurs
Combustion : au moins 80 KW
Post combustion : 80 KW
Puissance électrique : environ 2 KW
Cheminée :
Section : environ 30×30 cm
Hauteur (minimum) : au moins 8 m
Dimension de la porte de chargement : environ 50X50 cm

incinerator small to medium waste dispossal

Carburant Diesel
Capacité (M3) 1.92
Ave Capacity 1200kg
Consommation (litre/heure 12
Dimension externes
Longueur (mm) 3110
Largeur (mm) 2150
Hauteur (mm) 3200
Ouverture Porte 1000×2000
Dimension internes
Longueur (mm) 2200
Largeur (mm) 1050
Hauteur (mm) 800
Opération. incinerator small to medium waste dispossal for about 150-200 municipal waste from shopping mall, office and residential.

The waste most consist of vary materials plastics, rubber, paper, grass, leaves, woods, fruits, packaging carton, and many others

Minimum température d’opération 950
Maximum température d’opération 1320
Température de suivi oui
Thermostat oui
Ventilateur oui
Chambre de combustion secondaire 2 secs
garantie minimum 12 mois
Carburant Diesel
Capacité (M3) 1.18
Ave Capacity 750 kg
Consommation (l/h) 6
Dimension externes
Longueur (mm) 3110
Largeur (mm) 1800
Hauteur (mm) 3300
Ouverture Porte 770×2000
Dimension internes
Longueur (mm) 2100
Largeur (mm) 700
Hauteur (mm) 800
Opération. incinerator small to medium waste dispossal for about 150-200 municipal waste from shopping mall, office and residential.

The waste most consist of vary materials plastics, rubber, paper, grass, leaves, woods, fruits, packaging carton, and many others

Minimum température d’opération 950
Maximum température d’opération 1320
Température de suivi oui
Thermostat oui
Ventilateur oui
Chambre de combustion secondaire secs
garantie minimum 12 mois.a small animal crematorium, styles and prices