hot medical waste disposing machine, Operation Condition: 8-16 hr/ day



hot medical waste disposing machine, Operation Condition: 8-16 hr/ day 
Control: Built-in data recording
Operating temperature: Incinerator 
/Primary Combustion Chamber
Primary Chamber: 900 – 1200 0C

Type: continuous loading, Top Loading
Capacity/Burn rate per hour: 250 -300 kg/hr 
Material:
External- 3 layers 
Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock
Secondary 
Combustion 
Chamber:
Type: horizontal/vertical
Temperature:  1200- 1300 oC
Residence time of gases : >2 seconds
Ash Residue: <5% of original waste size
Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash
Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity
Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc 
Auxiliary device: Fuel cut-off device
Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      
Chimney (Stack):
Type: Vertical type
height:>7 meter’
Material: Fireproof cast, stainless steel
OUTPUT: 
GAS- SMOKELESS,ODORLESS 
ASH -Max <5% of original waste size
Reduction of Pollutant gas SO2, HCL, HF and line particulate
Emission standard:
WHO/ European
Test report for emission testing provided?
Heat exchange mode: Automatic

Accessories:  
All standard accessories for incinerator, including but not limited to loading system, heat exchangers, pollution control system, ash removal system, including ladder and oil tanker (2500litre capacity).
Operating Environment: 
The incinerator is capable to operate at the altitude of 2400mt above sea level. (according to the site conditions)
Power Requirement:
220 Vac single phase or 380 Vac three phase 4 wire system  50HZ   
Installation Testing and Commissioning :   to be conducted by certified or qualified personnel.  
Supplier shall provide the following documentation    
User (Operating) manual in English. 
Service (Technical / Maintenance) manual in English. 
Certificate of calibration and inspection from factory. 
Fast moving spare parts: Supplier is able to provide fast moving spare parts with quantities as described in the price schedule or their equivalent. 
Training: Supplier is able to provide training on operation, management and maintenance of incinerators.   
Warranty 
Comprehensive warranty for minimum 2 year. 
Maintenance Service during Warranty Period 
During warranty period supplier must ensure, corrective/breakdown maintenance whenever required. 
Supplier has a local agent or branch office in Ethiopia (please indicate the name and contact details of the agent) 
Supplier provides labor, lifting equipment and tools needed for the installation, testing and commissioning of the incinerator. The supplier will be responsible for the safety of its staff, workers and laborers during the installation, testing & commisssioning 
Able to provides all necessary information that would be used as an input for preparation of floor (platform) and room for the incinerator to be supplied such as the following; 
Lay outs (drawings) and  pictures of the incinerators to be installed 
 Length, width and height of incinerator,
 Area (length x width) for the floor (platform) and Length, width and height for roofing, for each type of incinerators to be installed 
Needs during the transport, installation, assembly, commissioning and operation of the equipment in terms of access points, available space to operate (inside and outside of the room), ways to get to the site where the equipment will be placed or any others. ; 
Technical Specifications (fuel consumption rate, weight, anchoring system, support points, etc.);
 Chimney specifications to be used for the roof design ( size, support needs, insulation); 
Considerations related to operation and Maintenance, for e.g., minimum available area to perform routine maintenance tasks and replacement of key parts that need to be changed more frequently; 
Any consideration/need of the incinerator while being operated that might impact the design of the room/shelter where it will be placed.
Other important information to be considered that can influence or impact the designing and building processes of the infrastructure for the incinerators, for example area dimension for other accessary parts like fuel tanker storage, if applicable, etc…. 
Delivery time (DAP, Addis Ababa) in weeks
Name of manufacturer including website of the manufacturer &/ supplier & country of origin



hospital incinerator manufacturers

The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated.
At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of incinerator plant are shown in below table:

hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center.
In Transit and Sorting Center one laboratory must be considered.
In this center, waste will be classified in two groups:
–    Unsuitable for burning
–    Suitable for burning
Unsuitable waste for burning can be divided into the 4 categories:
–    Buried materials
–    Materials (wastes) that need to be stabilized before buried
–    Materials (wastes) that can be sold.
–    Wastes that can be returned to petrochemical.
Suitable wastes are classified into the two categories:
–    Input wastes to rotary kiln, consist of solids and waste fluids.
–    Input wastes to static kiln, consist of clean fluids and gasses.
All solid wastes must be transferred to storage pit from Transit and Sorting Center. Solid wastes storage pit is input of rotary kiln.
All fluid wastes must be stored and stabilized in Transit and Sorting Center. All storage and stabilization devices or facility must be considered. Storage and stabilization devices (facility) consist of:
Tanks, Pumps (Transfer, Loading & Unloading), Agitator (Mixer), Blanketing System, Flare system, Instrumentation and Control Systems, etc
Storage and stabilization capacity must be considered based on worst case (shut down).
Generally incinerator plant consists of two similar trains (capacity of each train is 100%). Each train consists of a rotary kiln and a static kiln.

производство портативных установок для сжигания медицинских отходов в Китае

Возможность: 20 кг / час, диапазон температур: 600 градусов. C– 1100 град. C

Газоснабжение: природный газ / дизельное топливо

Двойная камера сгорания Полная система очистки (двойная

Результирующая газомоечная машина), двойной вентилятор, высота дымохода: 8 м

Электропитание: 220/240 В, одноступенчатое

1. Вид отходов: Мусор.
2. Любой другой тип:
3. Ежедневное количество отходов в кг: (50 лотов в день) SOW
4. Период – горелка обязательно будет использоваться каждый день: (минимум 12 часов) SOW
5. Примерная влажность материала:
6. Локальная работа горелки, а также критерии выхлопа: Агентство по охране окружающей среды США.
7. Какая высота требуется дымовой трубы: не выяснено.
8. Предлагаемое топливо: Deiseal Oil.
9. Доступность мощности, а также вид: 220 или 110
10. Информация о комнатах всегда в наличии: много места.
11. Требуется ли автоматическая система загрузки: [**] Да [**] Нет.
12. Требуется ли вам система очистки газов: [**] Да [] Нет.
13. Как скоро вы потребуете, чтобы система была предоставлена: 30.
14. Любой тип других определенных требований :.
15. Природа: (твердое / полутвердое / жидкое).

incineration in china

Combustion Efficiency     99.99%

Retention time    Of the flow gases not less than 2 Sec in the hot portion.

Excess Oxygen concentration  Of primary combustion chamber 3-6% max.

Refractory    The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and

with highly temp. resistance. Not less than 1400 C for the first combustion chamber, and not less than 1600 C for the

secandry combustion chamber, and at the same time prevent the Temp. of the outside body of the chamber not higher than

70 C.

Doors    Should be lined with the same bricks, and the edges lined with special suitable insulating material to prevent

any gas escaping, and the doors should be kept under negative pressure during the operation.

Air Emission Control System  With high destruction and removal efficiency (DRE). Not less than 99.9999 as per KEPA.

Wet System  If the system equiped with a CEMS washing the flow gas with water, then it should be manufactured from

suitable anti corrossion materials, and equiped with pH meter to measure and neutralize the water. It should be able to

use the water in closed recycled circuit many times before treating/ discharging into the sewage system in compliance

with KEPARS.

Chemical dosing It should be equiped with suitable autochemical dosing system to control the pH for the water of the

wet scrubber system including sensors.

Chimney       It should be suitable with the capacity and the technical specifications, with height not less than 12m from

ground level. With easy opennable sampling point equal about 3 inch, and the optimum sampling locations is at least 8D

downstream direction and 2D upstream from any flow disturbancies.

Sampling point    Should be equiped with a platform located down the sampling point by a distance not less than 1 m, and

equiped with suitable stairs from ground to the port with comfortable slope.

Ash Removal      It should be auto ash removal system.

Fuel       It should be dual system, such as diesel and natural gas.

Feeding System  Should be auto feeding system into primary chamber.

Control Room     Should be equiped with a control panel shows Temp. of the combustion burners, gas monitoring, digital

Temp. indecation for the primary/secondary chambers, digital Temp. indication for the gases…etc. it should be also

Auto operation, burnures on/off auto lamps switch, auto start/stop for air emission control system, auto gas continuous

monitoring system reading and print out of gas emission parameters…etc.

Cooling System   The primary chamber should be provided with auto cooling systemthrough nozzles to permit direct cooling

if the Temp. will be heigher than 1100 C.

Inter-lock system       The incinerator should be equiped with inter-lock system to prevent feeding the waste to the

primary chamber if the combustion Temp. less than 500 C.

Flue treatment and cleaning     To consist a combined system (wet/dry), using water, lime, active carbon and ceramic

filters.

Quenching system/Heat exchanger Should be made and manufactured from anti corrosion and acid attack materials such as

stainless steel 316 or equivalent.

Noise Level  Not more than 85 dBA during normal operation.

Inaddition    The desigh should insure that responsive fail-safe control systems are used.

The incinerator should be installed inside closed suitable building with good aeration and ventilation system.

The building has facilities for off-loading of wastes from transport vehicles. Auto cleaning system for trucks and

waste containers, and cool storage area…etc.

The quotation should included list of original spare parts for 7 years.

The quotation should include supervising, starting up and training of the operators and ministry of health

engineers inside/outside Kuwait.

Detailed drawings, catalogs should be included.Our normal activities generates  2-5 tons of assorted waste

materials per day which range from condemned carcasses, and other wastes all which need to be incinerated  at above

800Centigrade measured  flue exhaust gas.

HICLOVER Incinerator mobile small With Wheel and Brake

Model

YD-30 Mobile Type

Picture

 

Burning Rate

Average 30 kgs/hour

Feed Capacity

Average 60 kgs/feeding

Chamber Main Body

Stainless Steel

Mobile Function

With Wheel and Brake

Primary Combustion Chamber

280 Liters

Secondary Combustion Chamber

150 Liters

Mix Combustion Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.5 Kw

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 13.3 kg/hour

Internal Dimensions

80 x 60 x 60cm (primary chamber)

External Dimensions

125 x 90 x 260cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

100 Liters

Door Opening

50 x 50cm

Chimney Length

2.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

1600 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28

precio de combustión clave del calentador clínico

Nuestras actividades normales producen de 2 a 5 lotes de desechos diferentes al día, que varían de los cadáveres desechados, y también el precio de combustión primaria del quemador médico.

otros desechos, todos los cuales deben quemarse a más de 800 grados centígrados de gases de escape de humos.

centros de salud, así como instalaciones para recibir de forma segura el tratamiento de desechos contagiosos y patológicos. 50 kg / hora – – – –

Quemadores para ser realmente confiables, eficientes en gas con precios de fundido de alta / disminuida capacidad
Tecnología moderna:

Sistema de calefacción controlado por nivel de temperatura. Bienes raíces de servicio pesado, para ser un desperdicio médico de calidad, robusto, confiable y económico

Quemador con control adecuado, muy fácil de operar y también autoportante.
Los equipos deben ser preensamblados, preconectados, precableados & & & & evaluados antes del Transporte / Exportación.

En el marco de un asesoramiento ecológico y también de equipos clínicos & & & & tecnología moderna y compra conjunta, este

Purchase Bureau invita a candidatos para la precalificación con el objetivo de seleccionar principalmente empresas competentes para licitar

para la oferta anterior.
El suministro constituirá los dispositivos únicos para una gestión de residuos confiable, como se mencionó anteriormente para un individuo nuevo.

negocio de administración de contratos ambientales con procedimientos preparados 2013 en Indonesia además de Tailandia, así como 2014 en West & & & & East

Malasia para lograr esas soluciones expertas con el fin de cumplir con las necesidades de eliminación de seguridad y protección del gobierno federal

para instalaciones médicas y médicas, residuos especializados en el área y también para cumplir con el mayor criterio técnico en este particular

incineradores pequeños con filtro (con la mínima contaminación mínima) para quemar / quemar 5 kg / h, 10 kg / h, 15 kg / h,

20 kg / h, 25 kg / ha 50 kg / h, así como también 300 kg / h de SÓLIDO, NATURAL, SECO Y HÚMEDO NO PELIGROSO de ningún tipo (incluido el centro de atención médica)

desechos) todos los días o por hora. Debe ser sin humo, sin vapores, sin olor (olor), sin polvo, sin emisión de sólidos

bits y con la mínima contaminación mínima (dentro de todo el país además de los requisitos mundiales). Requerido para ser eco

saludable y equilibrado junto con aceptable con los requisitos de todo el mundo. Necesita no estar con depuradores de agua. Materiales de ceniza después de la fusión.

debe ser del 3-4%.

Nuestras actividades normales crean de 2 a 5 cargas de diferentes artículos de desecho al día que varían de los cadáveres desechados, así como también la tasa de combustión principal del quemador médico

Мусоросжигательный завод по переработке мусора на свалках из черного мешка

30 августа 2013 г. Последнее обновление в 21:18 BST

Пять советов на юго-востоке Уэльса создали сотрудничество, чтобы позаботиться о черных мешках для мусора, чтобы уменьшить количество мусора, отправляемого на свалки.

Власти стремятся сжигать отходы, которые не могут быть переработаны, и преобразовывать их в энергию для выполнения новой задачи, на которую федеральное правительство Уэльса ежегодно выделяет 4 миллиона фунтов стерлингов.

Об этом сообщает Иоло ап Дафидд, участник программы по окружающей среде.

Стоимость статьи из сетиQQ图片20160218145327

medical waste incinerators manufacturers

chemical agents to be utilized:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water solution,
azotic (nitric) acid vapour with concentration up to 1.1 kg/m3;
2.    neutralization method: thermal decomposition;
3.    neutralization temperature: +800?C to +1200?C;
4.    performance:
?    vapour capacity: 70 to 200 m3/h,
?    water solution capacity: 50 to 500 l/h;
5.    inlet pressure: up to 2 bars;
6.    automatic control system;
7.    overall dimensions shall allow for mounting the unit on a vehicle chassis.
medical waste incinerators manufacturers General Specifications
6mm plate steel sheel construction
11cm 1400 o C Refractory L iner
Temperature controlled Burners
Secondary combustion Burners
Interlock Switch on Load Doors
Separate Ash Door
One Second secondary Residence @ 1000 o C
400 ° C Silicone Based Paint Finish.
Alloy Temperature Sensor
Factory wired and tested
Capacity-20 kg / hr
Primary Chamber-1607 L
Hearth Area-1:36 sq. m
Secondary Chamber-694 L
Primary Burner (oil)-420,000 btu
Secondary Burner (oil)-900,000 btu
secondary Combustion-1/6 hp
Exhaust Stack-46cm x 6m
Electrical Service-220/50
Weight System-5.700 kg
Dimension “D”-152cm
Load Port Height- 60x 60 cm
Ash Port Height -36 x 36 cm

medical incinerator 20kg

We are looking for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr,

10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY AND WET NON-HAZARDUOUS of any kind

(including hospital wastes) per day or per hour. Should it be with no smoke, no fumes, no odour (smell), no dust, no

emission of solid particles and with least minimum pollution (within national and international standards). Must be

environmentally healthy and acceptable with international standards. Should not be with water scrubbers. Ash contents

after burning should be 3-4%.

 

Please incorporate this alarm as it is a requirement.

  1. In addition to the above the following instruments may also be required.

A carbon monoxide and/or oxygen meter/recorder

A smoke density meter/recorder

A gas flow meter/recorder

A solid particulate meter/recorder

Any other instrument or measurement that may be considered necessary–none

 

 

8     Location / Siting 1.    Must be sited in accordance with the relevant local municipal authority

planning scheme, the topography of the area and be compatible with premises in the neighborhood,

 

  1. Must be housed in a suitably ventilated room.

 

 

9     Emission Limits  1.    Combustion efficiency:

 

 

Combustion efficiency (CE) shall be at least 99.00%

The Combustion efficiency is computed as follows;

 

C.E=                % CO2           x 100

% CO2 + CO

 

  1. We are interested to work on Medical Incinerators in our country and looking for a company offering good

quality with reasonable prices, Initially we are interested for incinerator with a burning rate of 30 – 50 Kg/hour.The

temperature of the primary chamber shall be 800 ± 50o C

 

  1. The secondary chamber gas residence time shall be at least 1 (one) second at 1050 ± 50o C, with 3% Oxygen in

the stack gas.

 

 

4     Opacity of the smoke must not exceed 20% Viewed from 50 meters with naked eyes

  1. All the emission to the air other than steam or water vapour must be odourless and free from mist, fume and

droplets.

Waste Incineration Treatment BURNING RATE : 100-150kgs per hour HICLOVER TS150

BURNING RATE : -100-150kgs per hour

MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION )

MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION )

SECONDARY BURNING CAPACITY : COMPULSORY

DENSITY INSULATION : 50 mm high

Refractory capacity : min 114mm

HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C

AVEARGE BURN OUT TIME : MAXIMUM 3HRS

FUEL TYPE : FUEL OIL ( DIESEL )

FUEL CONSUMPTION IN LTRS/HR : average 14

RESIDNECY TIME IN SECONDARY CHAMBER : 2 STAGES


Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 100-150 kg/hour

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (Liter/hour)

Average 14(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

2000L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28