Archive: August 3, 2024

Incinerator YD-500 for Vietnam

 We finish this project in year 2010 to 2011 and delivery to Hochiminh port, Vietnam with 1×40’feet open top full container.


Items/Model YD-500
Burning Rate (kgs/Hour) 500 kgs/Hr.
Feed Capacity (kgs) 800 kgs
Equipment Weight 13000 kgs
Primary Chamber (Liters) 4000
Secondary Chamber (Liters) 1500
External Dimensions (cm) 320x220x460
Internal Dimensions (cm) 257x147x108
Oil Tank(Liters) 500
Door Opening (cm) 108 x 128
Chimney (M) 14
Chimney Type Stainless Steel
Secondary Chamber  YES
Mix-Combustion Chamber YES
Smoke Filter Chamber YES
Combustion Fuel Oil/Gas
Residency Time 2.0 Sec.
Temperature Monitoring YES
1st. Chmaber Temperature 800–1000
2nd. Chmaber Temperature 1000-1200


Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

manufacturer of ha zardous waste incinerator in china

Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system
Imputing door Mouth Width (mm): 760*760 (approx.)
Chimney External Diameter (mm): 300 ± 10
Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max)
Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h
Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz

Per your advertisement for 300 kg.hr. Model – We need to know the price via return.

How many Kg. of Fuel would be required for running this Model 10 hrs. everyday.

We have our own Freight Forwarding Agent.

We had a Contract for Garbage Management before their Civil War for 120 Tons/Day for one Municipality in North Africa
Medical Waste Incinerator

Dual Chamber (Primary & Secondary) with insulation slabs (fully insulated internal refractory lining) along with

controlled air blower for each chamber

Insulation / Refractory Thickness: ≥ 100mm

Chamber plate thickness: ≥ 6mm

Fuel Type: Natural gas based on burning fuel in combustion chambers

Waste Capacity: ≈ 150 Kg/Day

Incineration capacity: ≈ 25 Kg/Day (Separate waste charging and waste removal doors)

Burners: At least with (02) burners of automated start and stop functions

Combustion efficiency: > 97%

Temperature: programmable temperature with temp monitoring system

Residence time: 2 second in secondary chamber

Heating value: 4000 Kcal

Temperature Range: ≈ min 800ºC to max 1200ºC

Electrical supply: 220V with single phase

Chimney Plate Thickness: ≥ 5mm

Water scrubber: Scrubbing using reagent like lime & should made of SS 10 gauge of non-corrosion properties and painted

exteriorly by equipment grade heat resistive enamel

Chimney Height: between 15-25 feet

Контейнерная мобильная горелка Сжигатель медицинских отходов Модель CA50

HICLOVER – контейнерная мобильная установка для сжигания медицинских отходов, модель CA50


Версия

CA50

Изображение

Отходы терапии

Терапия сжиганием медицинских отходов

Возможность подачи

Обычные 100 кг на кормление

Горящая цена

Обычно 50 кг в час

Время горения на корм

В среднем 2 часа

Режим управления

ПЛК (Инсинератор с программируемым логическим контроллером)

Напряжение

220В

Мощность

1.0 кВт

Газ

Дизельное топливо

Нагреватель

Горелка Италии

Настройка подачи

Справочник

Отображение уровня температуры

Цифровой дисплей

Расход топлива (масло)

В среднем 16,9 кг / час

Внутренние размеры

100x80x70 см (первичная камера)

Внешние размеры

230 х 130 х 155 см (текст)

Камера сжигания отходов

560литров

Камера сжигания сообщений

280 литров

Емкость масляного контейнера

200 литров

Открытие двери

70 х 50 см

Дымовой вал

5,0 млн

Вес брутто

4500кг

Материал камеры

Огнеупорный кирпич, огнеупорный бетон

Максимум. Теплая ценность

166000 Ккал / час.

Технические характеристики процедуры

Температура твердой камеры

8000C -10000 C

Температура газовой камеры

10000 ° C -12000 ° C

Камера Anti-Rate

17500C

Время проживания

2.0 сек.

Горящая эффективность

> 98%

Отходы с более низкой теплотворной способностью

3000 ккал


Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-24

GENERAL SPECIFICATIONS FOR INCINERATORS

Primary and secondary burners: Separate electrically spark-ignited primary burners and secondary burners with automatic control shall be used to achieve the specified temperature requirements in the primary and secondary chambers. The flames  of the primary and secondary burners shall not impinge on the incinerator walls or floor.
The primary combustion chamber must:

1.    Be accepted as the primary combustion zone.
2.    Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels.
Other combustion methods will be judged on merits.

3.    Ensure primary air supply is controlled efficiently

Ensure minimum exit temperature is not less than 850oC

Air supply: Air supply in the primary and secondary chamber should be regulated between 30%-80% and 170%- 120% of stoichiometric amount respectively. Suitable flow measurement devices shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan after accounting for the air supplied through burners.The secondary combustion chamber must:

1.    Be accepted as secondary combustion zone.
2.    Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel.

3.    Ensure secondary air supply is controlled efficiently.

4.    Ensure flame contact with all gases is achieved.

5.    Ensure residence time is not less than two (2) seconds.
6.    Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not less than 1100oC.

7.    Ensure the oxygen content of the emitted gases is not less than 11%.
Ensure both primary and the combustion temperatures are maintained until all waste has been completely combusted

lnsulation: lnsulation to be used for masonry, reinforced concrete, or non-combustible material shall prevent damage to the foundation from excessive heat and shall be of a thickness to limit the outer casing to a maximum temperature of 66°C in an ambient temperature of 21°C when the incinerator is operating at full capacity.

Refractory: Refractory shall be #super duty# and heat-resistant to a minimum of 1100°C in the primary chamber and 1250°C in the secondary chamber. Refractory shall also be abrasion resistant in the prlmary chamber, constructed of plastic or castable type refractory, designed to prevent bulging and destruction due to heat stress, capable of supporting more than twice the hourly burning rate and preventing leakage of fluids, and with a minimum thickness of 11O mm for walls and hearths

Сборная мобильная установка для сжигания отходов медицинского учреждения в контейнерном исполнении, модель CA100

Предметы / Модель

CA100

Фото

Концепция

Терапия сжиганием медицинских отходов

Скорость сжигания

Стандарт 100 кг / час

Емкость подачи

В среднем 200 кг / кормление

Настройка управления

ПЛК (Инсинератор с программируемым логическим контроллером)

Горящая камера

1200L

Внутренние размеры

120x100x100 см

Вторичная камера

600 л

Камера дымового фильтра

да

Режим подачи

Справочник

Напряжение

220В

Мощность

1,3 кВт

Расход масла (кг / час)

Обычно 20,4 кг / час

Использование газа (м3 / час)

***

Отображение уровня температуры

Цифровое шоу

Температурный уровень защиты

да

Масляный бак

200л

Дверца подачи

80×60 см

Камин

5 метров

Тип дымохода

Нержавеющая сталь

1-й. Уровень температуры камеры

800 ℃ –– -1000 ℃

2-й. Температура камеры

1000 ℃ -1200 ℃

Время проживания

2.0 сек.

Вес брутто

6000кг

Внешние размеры

260x150x180 см

HICLOVER – Медицинское окружение  

Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-25

pet crematory

The temperature is over the minimum and under the maximum required temperature (e.g 1150?C) of the thermal

reactor (partial load).

 

When switching off, only the solenoid valve for the fuel supply closes, the burner fan stays on to cool and protect the

burner head.

 

The reactor burner shall be modulating burner with pre-ventilation working on the principle of an oil pressure atomizer

with return nozzle for diesel oil, consisting of:

 

–      Fan housing with high-powered fan and cover

 

–      Electric motor

 

–      Oil pressure pump with built-in oil pressure controller

 

–      Burner nozzle rod with return nozzle and baffle plate

 

–      Coupled control with servomotor, rate controller, regulating segment and air valves

 

–          Electromagnetic shut-off dampers

–      Burner tube with flame pot, burner connection and insulation flange

 

–      Electrical high voltage ignition with ignition transformer and ignition electrodes

 

In the control panel:

 

–      Oil firing sequence control automation relay.

capacity – 50 Kg

 

Burn rate – 20 Kg/h

 

maximum Temperature – 1000C

 

Operating Energy – Diesel

 

Ignition method –

 

Combustion chambers – 2

 

Insulation – refractory Lining

 

No of burners – 2

 

Loading Method – Front load with safety latch

 

Chimney – Heavy duty stainless steel

 

Control – Burner control

 

Thermostat control

 

Timer control

 

Fan timer control

 

Instrumentation -4 Digit temperature display

 

Ash removal – Separate ash removal door

 

Fuel consumption per Kg –

 

Automatic & simple to operate control pannel –

 

3 mm steel casing & fully insulation

 

Dense  refractory concrete lining rated to 1400 degree to C

 

safety chute for easy loading –

 

SS Flue as standard –

 

Heat recovery option –

 

Easy onsite Installation –

Incinerator YD-100 for Iraq

 There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several construction sites and all fuel type is diesel oil.

 

Items/Model YD-100
Burning Rate (kgs/Hour) 100 kgs/Hr.
Feed Capacity (kgs) 200 kgs
Equipment Weight 5300 kgs
Primary Chamber (Liters) 1200
Secondary Chamber (Liters) 500
External Dimensions (cm) 220x180x360
Internal Dimensions (cm) 130x100x90
Oil Tank(Liters) 300
Door Opening (cm) 55 x 80
Chimney (M) 10
Chimney Type Stainless Steel
Secondary Chamber  YES
Mix-Combustion Chamber YES
Smoke Filter Chamber YES
Combustion Fuel Oil/Gas
Residency Time 2.0 Sec.
Temperature Monitoring YES
1st. Chmaber Temperature 800–1000
2nd. Chmaber Temperature 1000-1200
Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.