Archive: April 5, 2023

family pet dog incinerator up for sale


1. Capability of damage in weight: 60 Kg/h.
2. It should be able to run very little less than 10 hours/day
3. This burner needs to have the ability to destroy all combustible wastes created by healthcare facilities, unique centers, research laboratories, institutes, and so forth.
4. Style Requirements: Kinds A, B, C, D, as well as E of clinical waste
5.” PYROLYTIC” burning, by taking care of the gasification of waste.
6. The burner needs to remain clear of the release of black smoke as well as likewise fantastic dust, throughout the loadings.
7. It must have the capacity to minimize the volume of wastes by 98%.
8. It should certainly be able to hold discharge in the 2nd shed with gas house of not much less than 2 secs.
9. The incineration must be entirely without noticeable smoke in addition to upseting odours.
The minimized calorific power (L.C.P) of this waste will be 3,500 kcal/kg
? The Temperature levels of burning: Minimum will be 850oC as well as likewise max 1400oC
?
The Quantity of the burning chamber: 1.200 L.
13. The Measurement of the door for filling in cm: 70 × 70.
14. Heater procedure need to be Automatic On/Off.
15. Fuel: diesel.
16. The company needs to supply needed details for the best of the installment.
This heater with “PYROLYTIC” burning need to have:.
17. A burning chamber of waste:.
* Totally restricted door for the hands-on loading of waste. The loading must be Manual, Set Lots.
* A heater of lighting which the usage is restricted to the ignition of waste.
* Frontage of loading with door seals boosted on joints, wheel of screw plug, versatile joint, as well as also loading protecting out of refractory.


Вертикально-чистый верстак

2019-05-13 Оборудование для очистки воздуха609 просмотров


Внедрение продукции

Чистый рабочий стол – это очистное оборудование, которое устанавливается в чистой комнате или на открытом воздухе и может поддерживать высокую степень чистоты на рабочем месте в соответствии с требованиями среды использования.  

Принцип работы:

Воздушный поток проходит через высокоэффективный фильтр HEPA вверху и равномерно оседает с верхней части шкафа ламинарным потоком, чтобы гарантировать отсутствие перекрестного загрязнения образцов в операционной. После того, как воздушный поток достигает рабочей поверхности, около 50% всасывается в решетку в задней части операционной, а остальная часть встречается и уравновешивается с наружным воздухом в передней решетке, что не только предотвращает попадание нефильтрованного воздуха в операционную. помещение непосредственно для загрязнения образца. В то же время он также предотвращает перетекание потока грязного воздуха после контакта с образцом и угрозу безопасности оператора.

Особенности продукта:

Использование технологии напыления холоднокатаного стального листа, повышение прочности и жесткости рамы и уменьшение амплитуды во время работы

Использование высокоэффективного фильтра HEPA, КПД по току 99,99%, нацеленность на частицы размером более 0,3 мкм

Хост оборудования использует эластичное соединение с низким уровнем вибрации и шума.

* Его можно спроектировать как двухстороннюю рабочую беседку, которая гибка в использовании и в то же время снижает затраты

Мониторинг реализации: электронное бесступенчатое регулирование напряжения и скорости, более удобное в использовании

Использование центробежного вентилятора с пеной, низкий уровень шума, низкое энергопотребление, может использоваться в течение длительного времени без обслуживания

Прозрачные боковые окна с обеих сторон для увеличения дневного света

Стандартный чертеж

Технические параметры

модель ECB0609-VPS ECB0618-VPD
Габаритные размеры (длина * глубина * высота мм ) 1200x780x1650 1900x780x1650
Внутренние размеры (длина * глубина * высота мм ) 950 * 600 * 750 1800 * 600 * 750
Площадь рабочей зоны (длина * глубина мм ) 0,57 м 2 1.08м 2
Расчетная скорость воздуха 0,30-0,60 м 2 / с 0,30-0,60 м 2 / с
Номинальный объем воздуха 875 м 3 / ч 1750м 3 / ч
Предварительный фильтр Стекловолокно, предварительная фильтрация крупных частиц пыли
Эффективность HEPA-фильтра 99,99%   КПД по току для частиц размером более 0,3 мкм
Стандарты чистоты воздуха в рабочей зоне Федеральный стандарт США 209E, класс 2, международный ISO 14644
Уровень шума 63 дБ 65 дБ
Интенсивность света 500 люкс
Структура шкафа основная структура Стальная пластина толщиной 1,2 мм или SUS304 толщиной 1,2 мм
Структура консоли 1,2 мм толщиной 304   Столешница из нержавеющей стали
Конструкция боковой стенки Толщиной 5 мм   Закаленное стекло
Электрическая конструкция Мощность / Напряжение 220 В / 50 Гц, однофазный
Мощность / ток 300 Вт 370 Вт
Электрический ток розетки

URL с дополнительным содержанием: www.ecolead.cn Тел: 025-57138032

prix de l'incinérateur de trèfle nanjing

Incinérateurs énormes – – INCINÉRATEURS INDUSTRIELS – – Spécifications ci-dessous.

2.) La dimension nécessaire pour les brûleurs est de 750 – – 850 kg de capacité

3.) Le débit de combustion doit être de 80 LL 100 kg / heure.

4) La chambre principale doit avoir un niveau de température de fonctionnement de 900 à 1200 degrés C.

5) L’incinérateur doit mépriser une seconde chambre à haute température ainsi que 2 secondes de gaz
temps de rétention à 850-1150 degrés C de sorte qu’il convient aux matériaux à haut risque.

6). L’incinérateur doit avoir une surveillance du niveau de température et un thermostat pour faciliter
fonctionnement et également garantie de la température du fond pour valider la bonne procédure.

7). Le brûleur doit être capable de rejeter l’un des déchets dangereux énumérés dans la
zone suivante.

8) Le brûleur doit pouvoir brûler du mazout et doit également être constitué d’un plus gros gaz
réservoir (10-500 litres) et également générateur (3 –– 40 kV) établi qui peut être transporté sur la remorque avec le
incinérateur pour s’assurer que l’appareil n’a pas besoin d’alimentation électrique extérieure.

9.) Le brûleur doit être monté sur remorque de manière à ce qu’il soit

Matériaux contaminés à incinérer

Produit chimique fort dangereux:

Différents types de solides combustibles, utilisant des textiles, de l’huile, ainsi que des cartouches de toner, des produits chimiques
pour la purification de l’eau et les consommables photo et les produits en plastique, vacants
boîtes en plastique / métal qui contiennent encore des restes de matériaux dangereux, absorbant l’huile.

Produit chimique liquide nocif:

Généralement divers types. d’acide, peinture, vernis, acétone, white spirit sans aromatique
Solvants, liquide artificiel pour solutions de rupture, liquide de dégivrage d’aéronef, hydraulique ainsi que
Huile de compresseur, Fréon, utilisée dans certains systèmes de réfrigération plus anciens, Pesticide liquide / spray, air
rafraîchir le spray et divers autres produits chimiques similaires.

Gaz pollué:
Surtout du diesel ou de l’essence infecté par de l’eau ou des solvants.

Huile usée et / ou infectée:

Utilisation d’huiles pour moteurs électriques et / ou d’huiles minérales impropres à l’usage prévu à l’origine. Moteur principalement électrique
et aussi de l’huile de transmission (environ 80%) polluée par un mélange de white spirit et également d’acétone (environ 51%), de fluide hydraulique (environ 5%).

Eau infectée:

Huiles usagées, lessivages, mélanges d’hydrocarbures / eau, solutions et également lixiviat.

Sol pollué:

Sol contaminé par le pétrole, le gaz ou 11 produits chimiques.
Sol contaminé pollué par des produits chimiques qui doivent être réutilisés en décharge.
Saleté polluée – traitée et remplacée sur le site Web.

Solides contaminés par l’huile
Les chiffons, les absorbants, le carton, l’huile ainsi que les filtres à carburant, les filtres à air sont exclus en tant que matières nocives.

Déchets électroniques:

Déchets d’appareils électroménagers ou de réglages électriques ou numériques, y compris la carte de circuit imprimé,
contenant une matière toxique et / ou un métal lourd et / ou émettant un faible rayonnement.

Cellules de batterie utilisées:

Batterie sèche, batterie UPS ou autres types, batteries usagées / cellules de batterie non triées, ayant
produits dangereux.

Batteries au plomb-acide utilisées:
Batteries au plomb usagées, plu / non déchargées et entières ou brisées.

Déchets cliniques nocifs:

Déchets professionnels et assimilés, résultant de techniques cliniques, infirmières ou similaires, ainsi que déchets
générés dans les installations tout au long de l’enquête ou de la thérapie d’individus (danger biologique).

Ran out médicaments, fort:

Déchets de médicaments, de médicaments et aussi de médicaments, constitués de médicaments délicats.

Médicaments arrêtés Iiquide:

Déchets de produits pharmaceutiques liquides, divers types de produits chimiques liquides pour la thérapie, médical
de la graisse, ainsi que des médicaments à base de paraffine.

Ran out et / ou fod infecté:

Aliments frais avariés ou MRE inutilisables (Meal Ready for Consume – – nourriture sèche)

Formation sur site et option d’assemblage pour les incinérateurs industriels

I. Les acheteurs potentiels doivent inclure 1a tarif dans leur offre de formation dans un lieu central (Goma ou
Bukavu) environ 15 personnes dans l’exploitation et l’entretien de la
dispositifs.

Incinérateurs intelligents de cendres

1. La taille requise pour les brûleurs est que l’appareil collabore avec un fini ouvert de 55 gallons
tonneau en acier.
2. Le système doit fonctionner avec. pas de gaz et n’utilisez que de l’énergie électrique de 120 V ou 220 V pour les ventilateurs.
3. Le système doit faire fondre les déchets pollués par les hydrocarbures ainsi que les déchets médicaux avec un matériau d’humidité de 0 à 15% J.
4. Chaque appareil doit inclure deux tambours en acier, pour garantir qu’un tambour de rechange est disponible.

Choix des composants de rechange.
S’il y a un type de composants de rechange suggérés par le fournisseur, cette liste ainsi que le coût doivent être inclus comme un choix dans la transaction.

ความแตกต่างระหว่างฟิลเตอร์ชัตเตอร์ลูกกลิ้งแนวนอนและแนวตั้งอัตโนมัติ

22 พฤษภาคม 2019 Industry News 490 views

ความแตกต่างระหว่างฟิลเตอร์ชัตเตอร์ลูกกลิ้งแนวนอนและแนวตั้งอัตโนมัติ

ทุกคนรู้ดีว่าไม่ว่าเราจะใช้ม่านม้วนอัตโนมัติหรือไม่ ก็สามารถแบ่งออกเป็นแนวนอนและแนวตั้งได้ ที่นี่เราสั้นแนะนำความแตกต่างระหว่างตัวกรองบางส่วนในแนวตั้งและแนวนอนอัตโนมัติที่คดเคี้ยว

1. ความแตกต่างของสถานที่ใช้งาน

ประเภทแนวตั้งเป็นประเภททั่วไป มักใช้ในสถานที่ที่ไม่มีข้อจำกัดด้านพื้นที่ และส่วนตัวกรองมักเป็นช่องเปิดในผนัง

ประเภทแนวนอนมักใช้ในพื้นที่ขนาดเล็กหรือสั้น เมื่อความสูงของพื้นที่มีจำกัด เราต้องพิจารณาพื้นที่ตัวกรองที่มีประสิทธิภาพเพื่อให้ตรงกับปริมาณอากาศที่ต้องการอย่างเคร่งครัด การออกแบบที่กว้างและยาวของตัวกรองไขลานอัตโนมัติแนวนอนสามารถติดตั้งได้ในพื้นที่ขนาดเล็ก และสามารถตอบสนองความต้องการในการออกแบบปริมาณอากาศ

2. ความแตกต่างของรูปลักษณ์

อุปกรณ์แนวตั้งทั้งชุดตั้งตรงและต้องขึ้นเมื่อเปลี่ยนวัสดุกรองใหม่

ประเภทแนวนอนตั้งอยู่ด้านข้าง และสามารถเลือกตัวกรองสำรองได้ทางด้านซ้ายหรือด้านขวาของอุปกรณ์

3. ความแตกต่างของระบบม้วนสื่อกรอง

ประเภทแนวตั้งเป็นวัสดุกรองจากบนลงล่างตามยาว

ตำแหน่งแนวนอนคือจากซ้ายไปขวาหรือทิศทางตรงกันข้ามในแนวนอน

URL เนื้อหาเพิ่มเติม: www.ecolead.cn โทร: 025-57138032

Incinerator for Pharmacuticals Comapny

Product Description

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 
Incinerator fuel: Gas incinerator, oil incinerator 
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, clover incineraters, clover medical China, clover medical net, clover-medical, clovermedical. Net, construction of an incinerator, cost for incineration for pets cost of running 100kg, 
Cremation equipment cost animal, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc. 

So, why we still use incinerator? 
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control. 
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two reason but not only above, we still use incinerators. 

How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model’s price around $5, 000USD per unit and large scale model’s price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system. 
And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc. 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerator: Burning Capacity 20 Kg/Hour

Basic Info.

Model NO.:incineration unit for hospital waste
Export Markets:Global

Product Description

Key Attributes:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to order  * High fever, long life of incinerator.  * Free or minimum installation on site.  * High speed, from 10kgs to 500kgs per hourto 6ton daily.  * 50 capacity incinerator, 50 kg incinerator, 50 kg incinerator china with ce mark, 5  * PLC Control Plane. *according to order  New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation  5.50 kg per hour waste incinerator, 50 kg/hr medical waste incinerator, 50 kg/hr rated capability diesel incinerator,

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

производители мусоросжигательных заводов

1. ОБЪЕМ РАБОТ Работы, указанные в контракте, будут включать.
1. Поставка, установка и ввод в эксплуатацию мусоросжигательной установки в соответствии с техническими условиями.
2. Обеспечение соблюдения OSHA и других законодательных требований, касающихся здоровья и безопасности рабочих во время выполнения работ, указанных в этом тендере.
3. Оценка, подготовка и строительство типового ангара для мусоросжигательного завода с одним складом для отходов (см. Проект).

4. Предоставление руководств по эксплуатации и техническому обслуживанию и чертежей с графиком технического обслуживания и инструкциями.

5. Резервуар для жидкого топлива – низкоуглеродистая сталь, емкость 1500 литров.

6. Обучение на месте эксплуатации и обслуживающего персонала.

ВАЖНЫЙ
Производители инсинераторов Для того, чтобы Заказчик мог провести окончательную оценку тендера, участников тендера просят представить вместе со своими предложениями подробные спецификации, чертежи и каталоги с инструкциями по вводу в эксплуатацию и техническому обслуживанию инсинератора, который они намереваются поставить, установить и ввести в эксплуатацию. Претенденты, которые не соблюдают это требование полностью, будут отклонены. 2. ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ НЕОБХОДИМОГО ИНСИНЕРАТОРА

2.1 Общее описание

Установка должна состоять из четырех отдельных секций, демонстрирующих три принципа турбулентности, времени пребывания и сохранения температуры. Регулируемые разделы могут включать, но не ограничиваются:
1. Общая схема завода
2. Загрузочная камера / загрузка
3. Первичная камера сгорания.
4. Скрубберы для твердых частиц
5. Скрубберы кислых газов.
6. Стек / дымоход.
7. Минимальный объем первичной камеры = 0,18 м3.
8. Скорость сжигания (скорость сжигания отходов) = не менее 20 кг в час.
9. Должен иметь загрузочную дверцу с противовесом во всю ширину, обеспечивающую легкий доступ к основной камере для загрузки и удаления золы.
Поставка, установка и ввод в эксплуатацию мусоросжигательного завода на Восточных гидроузлах [Страница 28

2.2 Кормление и зарядка
Следует использовать контролируемую гигиеническую механическую подачу, не влияющую отрицательно на температуру воздуха в первичной и вторичной камерах инсинератора.
2.3 Первичная камера сгорания.

а) Эта камера должна быть оборудована горелками, работающими на топливе с низким содержанием серы.
б) Камера должна обеспечивать минимальную температуру на выходе 850 градусов по Цельсию.

2.4 Вторичная камера сгорания (после горелки)

а) Должны быть оборудованы горелками, работающими на топливе с низким содержанием серы.
б) Убедитесь, что подача вторичного воздуха регулируется.
c) Убедитесь, что время пребывания составляет не менее двух секунд.
г) Убедитесь, что температура газа, измеренная у внутренней стенки вторичной камеры, а не в зоне пламени, составляет не менее 1100 градусов по Цельсию.
д) Убедитесь, что содержание выделяемого кислорода в выделяемых газах составляет не менее 11%.
f) Убедитесь, что температура первичного и вторичного сгорания поддерживается до тех пор, пока все отходы не будут полностью сожжены.

2.5 Удалители твердых частиц

После вторичной камеры сгорания должен быть установлен механический коллектор твердых частиц для удаления твердых частиц, уносимых потоком дымовых газов. Сборщики твердых частиц могут включать в себя любое из следующего или их комбинацию:
а) Циклонный сепаратор
б) Электрофильтры
в) тканевые фильтры
2.6 Дымоход / дымовая труба

l) Дымоход должен иметь высоту не менее 10 метров над уровнем земли и выходить за самую высокую точку здания не менее чем на 3 метра для всех крыш. Следует учитывать топографию и высоту прилегающих зданий в радиусе 50 метров.
m) Дымоход должен быть виден оператору из зоны кормления.
n) Минимальная скорость на выходе должна составлять 10 метров в секунду и как минимум в два раза превышать скорость окружающего ветра (скорость потока = скорость ветра x 2), в зависимости от того, что больше, чтобы не допустить смыва выходящих газов вниз.
o) Должна быть предусмотрена точка измерения выбросов.

2.7 Контрольно-измерительные приборы

a) Как для первичной, так и для вторичной камер должен быть предусмотрен прибор для определения температуры внутренней стенки, а не температуры пламени горелки.
б) Должна быть установлена звуковая и визуальная сигнализация, чтобы предупредить оператора, когда температура вторичной камеры упадет ниже требуемой температуры.
c) Должны быть предоставлены измеритель / самописец окиси углерода и кислорода.

г) Должен быть предусмотрен измеритель / регистратор плотности дыма.
e) Должен быть предусмотрен измеритель / регистратор твердых частиц.
е) Любой другой инструмент, который может быть сочтен необходимым.

2.9 Пределы выбросов

a) Эффективность сгорания (CE) должна быть не менее 99,00%, где CE =% диоксида углерода x 100 / [% диоксида углерода + монооксида углерода].
б) Температура первичной камеры должна быть 800 +/- 50 градусов по Цельсию.
c) Время пребывания газа в вторичной камере должно составлять не менее 1 секунды при 1050 +/- 50 градусов по Цельсию и 3% кислорода в дымовом газе.
г) Непрозрачность дыма не должна превышать 20% при просмотре с 50 метров невооруженным глазом.
д) Все выбросы в воздух, кроме пара или водяного пара, должны быть без запаха и без тумана, дыма и капель.
f) Эффективность уничтожения и удаления 99,99% (DRE) для каждого основного органического опасного компонента (POHC) в исходных отходах, где DRE [(Win – Wout) / Win] x 100, где Win = массовая скорость подачи POHC в отходах. поток, подаваемый в установку для сжигания отходов, и Wout = массовая скорость выброса POHC в дымовой трубе перед выбросом в атмосферу.
g) Средняя концентрация диоксинов и фуранов в выбросах не должна превышать 80 мг / м3 общих диоксинов и фуранов при измерении в течение периода от 6 до 16 часов.

– Ручной технический мониторинг поставляется с оборудованием со всеми объяснениями сбоев и способов их устранения.
Производительность / остров: 4000 кг / сутки; 25000 кг / сутки; 31000 кг / сутки; 48000 кг / сутки

Температура горения – более 12000С.

Две камеры – минимум

Выбросы – диоксины и тяжелые металлы – лучше, чем Киотский протокол

Эмиссия – система мониторинга

Распаковка отходов – прямо с мусоропровода на мусоросжигательный завод

health center burner design


INCINERATEUR DE DECHETS HOSPITALIER health center incinerator format

SPECS TECHNIQUES.
Capacité harmful de 55 Kg/h jour de déchets hospitaliers avec un p?. c. i jusqu’ à 3.200 Kcal/Kg
1) Kind de déchet

hospitalier
2) Pouvoir calorifique inférieur 3.200 kcal/kg
3) Humidité 20%.
4) Teneur en cendres et/ou inertes 8%.
5) Capacité harmful nominale 55 kg/h.
6) Quantity chambre de burning 1,65 m3.
7) Amount chambre postcombustion 2.1 m3.
8) Temps transportation des fumées en message burning/ sec.

13) Flammable prévu Gasoil.
14) Br?leur en chambre de combustion nbr?: 1.
15) Br?leur en chambre de postcombustion nbr?: 2

CONSTITTUTION DE L’APPAREIL.
1. CHARGEMENT.
Système de chargement hydraulique afin de pouvoir battery charger le 4 en toute sécurité même durant child fonctionnement et

aussi assurer la puissance devastating globale de 450 kg/j?
Le système comprend?:.
1-1Trémie de chargement de forme parallélépipédique de 0,5 m3 de volume, réalisée en t?le d’acier, bridés sur la paroi

frontale de la chambre de burning et munie d’un couvercle à charnières actionné par vérin hydraulique?.
Dimensions?:.
oLongueur 1200 mm.
oHauteur 700 mm.
oLargeur 600.
1-2Un poussoir hydraulique assurera le chargement de la chambre de combustion.
1-3 Une porte de chargement de la chambre de combustion constituée d’une guillotine à vérin hydraulique revêtue

de réfractaire.
1-4Un main hydraulique put piloter tous les vérins de commande, comprenant?: réservoir, pompe, électrovannes et

tuyauteries

2. CHAMBRE DE COMBUSTION PRIMAIRE

2-1- Le bati est une structure métallique cylindrique revêtue intérieurement d’une couche d’isolant et d’une

couche de réfractaire.
2-2-Volume intérieur?: 1,65 m3.
2-3-Aménagement.
? portillon de décharge des cendres?: frontal?; monté sur double charnière et revêtu de réfractaire avec hublot

d’inspection.
? La connexion à la chambre de chargement est revêtue de réfractaire.
? La connexion de la chambre de combustion et de la chambre de article combustion est revêtue de réfractaire.
? Setup des bruleurs.
? Setup du système de circulation de l’air comburant.
? Installment des sondes de mesure de la température.
? Le bac de récolte des cendres est en acier au carbone sur roulettes, équipé de racloir métallique permettant

l’évacuation manuelle des cendres.
3. BRULEUR DE LA CHAMBRE DE COMBUSQTION.
Un bruleur de kind à une flamme à l’air soufflé, alimenté the same level gasoil, équipé des dispositifs de sécurité Puissance

thermique installée 165 KW.
4. AIR COMBURANT.
Le système de distribution et dosage de l’air primaire en chambre de burning comprend?:.
? Ventilateur centrifuge.
? Canalisations de distribution air.
? Systéme de circulation d’air à 2 canaux.
? Soupape de régulation de l’air motorisé selon les phases de cycle de fonctionnement et de la température

5. CHAMBRE DE POST BURNING.
5-1- Chambre de article burning est installée au dessus du foyer de combustion, elle est constituée d’un

cylindre métallique revêtu intérieurement d’une couche d’ isolant et d’une couche de matériaux réfractaires.
5-2- Volume intérieur?: 2,1 m3.
Est dimensionnée put pouvoir garantir un temperatures de fumée de 2 secondes à 1100 ° C avec un pourcentage d’oxygène libre

d’au moins 6 %.
5-3 -Accessoires.
? Trappe de visite boulonnée frontal put permettre l’inspection périodique.
? La intermediary à la chambre de burning est tapissée de réfractaire.
? Setup les br?leurs.
? Installation des sondes de mesure température.
6. MANUFACTURING DE L’AIR COMBURANT DE LA CHAMBRE DE POST COMBUSTION.
? Ventilateur centrifuge.
? Tuyauteries de distribution d’air.
? Série de vannes de circulation d’air.
? Soupape de régulation de l’air soufflé asservi par la sonde du débit d’ oxygène

7. BRULEUR DE LA CHAMBRE DE MESSAGE COMBUSTION.
Sont prévus 2 br?leurs du type à l’air soufflé au gasoil équipés des dispositifs de sécurité.
A la mise en route du four les deux br?leurs sont allumés pour assurer la température minimale d’au moins 1100 ° C?;

ils restent en marche successivement pour maintenir la température constante.
Puissance thermique installée (290 + 350) KW.

8. CHEMINEE D’EVACUATION.
Constitué the same level un avenue métallique vertical de 8 m de long installée au-dessus de la chambre de COMPUTER, diamètre 630 mm

en t?le d’acier au carbone avec garnissage intérieur en réfractaire

9. ARMOIRE ELECTRIQUE DE COMMANDE ET GUIDELINE.
Composée de?:.
? Circuit 380 V- 50 HZ-3 stages.
? Voyant sous stress.
? Commande d’arrêt général.
? Voyant état des bruleurs.
? Affichage des températures des deux chambres.
? Minuterie des temps des cycles.
? Une variation des vitesses des ventilateurs.
? Le tableau et les cablages sont prévus aux règles CEI avec security IP 55.
? Microprocesseur put le contr?le et la régulation des températures, ainsi que les cycles d’opération.
? Cablages réalisés selon les règles CEI.

10. INSTRUMENTATION DE CONTROLE ET DE MESURAGE CONTINU.
Les dispositifs suivants sont prévus?:.
1) Thermocouples pour la mesure de la température en chambre de combustion? et postcombustion, à la sortie de

l’échangeur dans la area d’entrée du filtre.
2) Système de mesure de la concentration d’oxygène dans les fumées humides a la sortie de la chambre de postcombustion

constitué de?:.
? Sonde de mesure de l’oxygène à l’oxyde de zirconium.
? Pompe à la membrane.
? débitmètre


Equipo de cremación para desechos médicos

Información básica.

Modelo NO .: capacidad del incinerador de doble cámara de aire controlado
Mercados de exportación: Global

Descripción del producto

Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores de desechos en China. Somos fabricantes locales y uno de los mayores exportadores de China. El costo de un incinerador de animales, el costo de un incinerador con una tasa de carga de 20 kg / h, el costo de funcionamiento del incinerador de 100 kg de capacidad, el costo del incinerador de pequeña escala, el equipo técnico del incinerador pirolítico es el principal tratamiento de desechos en todo el mundo, para desechos médicos, incineración de animales, Cremación de mascotas y otros sólidos sólidos. La capacidad de 10kgs / Hr. Hasta 500kgs / Hr., Hasta 6ton por día. Actualmente, suministramos diferentes series para los requisitos de los clientes locales y diseñamos un incinerador actualizado con nuestra tecnología líder. La característica de diseño actualizado de nuestra gama de incineradores los convierte en uno de los más rentables del mundo.

Artículos / Modelo YD-30 YD-50 YD-100 YD-150
Tasa de combustión (kg / hora) 30 kg / hora 50 kgs / Hr. 100 kgs / Hr. 150 kgs / Hr.
Capacidad de alimentación (kgs) 60 kilogramos 150 kilogramos 200 kilogramos 300 kilogramos
Peso del equipo 2300 kilogramos 4000 kilogramos 4300 kilogramos 7000 kilogramos
Cámara primaria (litros) 360 900 1200 1500
Cámara secundaria (litros) 200 200 500 500
Dimensiones externas (cm) 145x90x175 200 x 160 x 230 220x180x360 240x170x380
Dimensiones internas (cm) 100 x 60 x 60 120 x 90 x 85 130x100x90 150x100x96
Tanque de aceite (litros) 200 300 300 500
Apertura de la puerta (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimenea (M) 5 5 10 10
Tipo de chimenea Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable
Cámara secundaria
Cámara de mezcla de combustión
Cámara de filtro de humo
Combustible de combustión Gas de petróleo Gas de petróleo Gas de petróleo Gas de petróleo
Tiempo de residencia 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg.
Monitoreo de temperatura

brûleur d'hôpital

Fourniture, installation et test de brûleur à déchets cliniques avec une capacité de 75 kg / h de gaz (GPL) au total avec tous les accessoires et aussi par conséquent avec la cheminée en fonction des spécifications techniques ainsi que des conditions de bien-être public
faire un espace pour l’incinérateur qui convient à 3 incinérateurs comme dans la chose 3.1.1 et fixé au magasin de déchets de la salle du brûleur qui convient aux déchets pendant une période de sept jours ainsi que tous les bâtiments en béton amélioré avec la préparation du bâtiment du brûleur et aussi des magasins avec tous les travaux de câblage, de systèmes électriques et d’éclairage, d’adduction d’eau et aussi d’assainissement
l’approvisionnement du bâtiment de l’incinérateur ainsi que la salle de stockage des déchets avec un système de gicleurs d’extinction d’incendie repose sur la source de l’eau du réseau du site de base, ainsi qu’un système d’alarme incendie contient des unités de détection de chaleur, de fumée et ce système est lié au médical systèmes d’alarme d’urgence pour installations
Fourniture, mise en place ainsi que criblage du système de circulation d’air de la salle d’incinération et aussi de l’entrepôt avec ventilateurs COUVERTURE DE TOIT TOP EXHAUET FOLLOWERS les offrant avec des filtres à haute performance (HEPA FILTER trip pour attirer les ventilateurs avec prise du prix de modification d’air de 5 fois par heure avec ruisseaux et grilles d’air nécessaires
Fourniture, configuration et test de différentes unités de conditionnement pour la base de données des déchets UNITES FENDUES EN CONDUIT et capacité suffisante pour maintenir le niveau de température intérieure à 14 degrés Celsius en été et en hiver
Fourniture, installation, criblage de l’atelier de refroidissement de surfaces murales blindées préfabriquées à l’intérieur de la salle des déchets d’une capacité de 35 mètres cubes pour conserver les déchets médicaux à une température de zéro Celsius jusqu’à la perte, y compris l’unité de refroidissement et tous les accessoires
Bois NON SÉCURISÉ.
jouer du bois.
déchets résiduels de pétrole.
système de flexibles hydrauliques.
sacs d’hydroxyde de calcium.
sacs ou caisses en bois contenant du cyanure.
déchets médicaux.
filtres.
médicaments.
PAS de sciure DANGEREUSE.
Plastique.
auvents en plastique et également en textile.
bois.
baignoires en plastique.
caoutchouc.
déchets hygiéniques.
EPP.
sacs en plastique.
bâtiment et construction récurrents.
chiffons ou serviettes infectés.
plastique ou emballage alimentaire.
plats de polyestirène, verres, cuillère, fourchette, etc. déchets cliniques d’incinérateur de capacité à un niveau de température de combustion élevé.
Avec un gadget sans fumée pour protéger le décor ainsi qu’avec deux chambres de combustion équipées de brûleurs à gaz ou à l’huile.
– brûleur pour jeter les objets de grand volume de 70 cm.
discordance: système de contrôle automatique.
– capacité de destruction de 20 à 30 kg.
Première pièce / température = 900 ° C combustion.
Deuxième pièce / niveau de température = 1200 ° c postcombustion