Archive: December 3, 2022

likewise biomedical and dangerous waste


requirements are figured out, partially, by exactly just how the land is designated under area government advancement plans (i.e. land usage

zoning).

Strong waste burners are crafted systems that are qualified of frequently accomplishing melt temperature levels over of 1000oC

and likewise a holding time of at the very least one. The incineration of

also biomedical and unsafe waste and also sewer sludge calls for certain devices, functional controls as well as training that are

past the array of the existing paper.
Air System burning. Gases from this insufficient burning then get in a second melt chamber where enough air

is instilled and also full burning is achieved.

Solitary Chamber Excess Greater than an adequate amount of air (as high as 50% more than the amount
Air System of air needed) is infused into the solitary thaw chamber to complete total burning of the waste.

Constant Feed An incineration procedure that remains in a continuous shed cycle. A consistent feed

Establish feed dual-chamber handled air incinerators currently run at a number of remote commercial areas in north

Canada and Alaska. They are generally taken right into consideration to have the greatest feasible top high qualities of all the heaters and also open

burning strategies pointed out, they require to be developed for the kind and amount of waste to be shed. The highlights of this

type of incinerator are:

Set procedure permits better control of temperature level as well as air throughout the shed procedure.
A broad selection of wastes can be destroyed, waste may require to be segregated and also remixed in order to acquire a

consistent residence heating worth near the design aspect of the incinerator.
On the surface supplied gas as well as power are required for the heaters in addition to forced air ventilation. A correctly running double-

chamber managed air system will definitely decrease issues with pet tourist attraction as the production of base and additionally fly ash as well as smoke

is decreased.

Area 2.3.2 is planned to provide the site visitor with a brief intro to heaters. It is not meant to give

info appropriate for the design, selection or procedure of an incineration system. Anyone taking into consideration the acquisition of

an incineration system must first contact the system’s supplier or various other qualified people with experience in the

incineration of solid waste.

requirements are figured out, partly, by exactly how the land is marked under area government growth plans (i.e. land use

zoning).

Solid waste incinerators are crafted systems that are qualified of consistently completing burn temperature level levels over of 1000oC

and additionally a holding time of at the very the very least one. The incineration of

also biomedical as well as harmful waste and also sewer sludge calls for certain tools, functional controls as well as training that are

past the range of the present paper. A correctly running dual-

chamber managed air system will definitely lower problems with animal visitor attraction as the production of base and likewise fly ash as well as smoke

is lowered. Any type of individual considering the procurement of

an incineration system need to first get in touch with the system’s supplier or various other certified people with experience in the

incineration of strong waste.

is decreased.

Area 2.3.2 is planned to provide the visitor with a short introduction to burners. It is not intended to provide

information suitable for the style, choice or operation of an incineration system. Any person considering the acquisition of

an incineration system must first get in touch with the system’s supplier or various other qualified individuals with experience in the

incineration of solid waste.


Process Engineering Design of Pathological Waste Incinerator

Basic Info.

Model NO.:small medical waste incinerator manufacturers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may use within this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation material, liquid waste and gas waste.  GB18484-2001. 

Q: Treatment capacity  A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of ordinary power. 

Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is about 16 hours. The life of incinerator involving 5-10 year based on use. 

Generally, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, then please compute the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the clinic, that’s mean you need 1 incinerator capacity around 400kgs per day, switch to power per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, funding, development, etc, you may use capacity from 30-50 kgs each hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Testing and Assembly A: We supply all records and incinerators simple to setup and operation. Client can send people visit our factory to learn installation and operation. Generally, We do not send engineer to local site if not ask. The dispatch cost is additional based on order.  The next combustion chamber: 1000-1200 centi degree.  PLC mode based on order and model. 

One individual can service 02 device incinerators. Medical waste diesel incinerator, medical waste incinerators, cellular incinerator china, nanjing clover medical technology co., ltd., pet crematorium equipment, The staff must have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on functionality consumer guider, and understand threat of medical waste to safeguard employee self with necessary security element. 

Q: The Residency period in secondary combustion space A: 02 sec.

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. Medical waste diesel incinerator, medical waste incinerators, mobile incinerator china, nanjing clover medical technology co., ltd., pet crematorium equipment, The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

cheap incinerators

Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, dependable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transfer / Export.

Note: Similar Technology and / or Tenderers Proposals are welcome.

Within the framework of an environmental equipment & technology consultation and joint purchasing, this Procurement / Notary Bureau invites applicants for pre-qualification from the aim of primarily selecting capable companies to bid for the above tender.
The supply will include the special equipment for successful waste management as stated above for a brand new private environment contract management firm with planned operations 2013 in Indonesia and Thailand, and 2015 in West & East Malaysia to execute those professional services to be able to comply with the government security disposal requirements for animal waste from the area and to meet the higher technical standard in this particular field to be able to protect the public and contain contagious & infectious viruses and animal caused diseases. The spread of a new disease of pigs, also the ‘Nipah Virus Disease’, first evident in 1998 in S.E.Asia, which causes illness and death in both humans and pigs, is increasing again; as well as the sudden passing of sows and boars was recorded in pig farms in Malaysia and other areas in S.E. Asia.

Incinerator Video

Key Features:
— Full range incinerator with Economized Small Scale incinerator, 
Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, 
Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

La incineración de desechos peligrosos

Información básica.

Mercados de exportación: Global

Descripción del producto

Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores de desechos en China. Somos fabricantes locales y uno de los mayores exportadores de China. El equipo técnico de incineración pirolítica es el principal tratamiento de desechos en todo el mundo, para desechos médicos, incineración de animales, cremación de mascotas y otros wste sólidos. La capacidad de 10kgs / Hr. Hasta 500kgs / Hr., Hasta 6ton por día. Actualmente, suministramos incinerador de aguja de jeringa, compra online, diseño técnico de incinerador de residuos de riesgo sanitario, especificación técnica del incinerador 500 pdf, los incineradores más baratos del mercado, diferentes series para los requerimientos del cliente local y diseño actualizado del incinerador con nuestra tecnología líder. La característica de diseño actualizado de nuestra gama de incineradores los convierte en uno de los más rentables del mundo.

Características principales:
* Todos los modelos con doble cámara de combustión.
* Chimenea / chimenea de acero inoxidable, larga vida útil. * según pedido
* Alta temperatura, larga vida útil del incinerador.
* Instalación gratuita o mínima en obra.
* Alta velocidad de combustión, de 10 kg a 500 kg por hora, hasta 6 toneladas por día.
* Plano de control PLC. * según pedido
* Nuevo diseño para el negocio de cremación de animales de compañía.
* Garantía de un año en incinerador y piezas en stock.
Ámbito de aplicación:
1. Hospital y clínica: Residuos Iátricos, Residuos Infecciosos, Vendajes, Biorresiduos, Medicina.
2. Matadero y hospital y granja de mascotas: animal muerto, biorresiduos.
3. Comunidad, puerto y estación marítima: residuos sólidos urbanos, etc.
4. Laboratorios, ubicaciones remotas, operaciones de socorro en casos de desastre, cremación de animales

Artículos / Modelo YD-200 YD-300 YD-500 YD-600
Tasa de combustión (kg / hora) 200 kgs / Hr. 300 kgs / Hr. 500 kgs / Hr. 600 kgs / Hr.
Capacidad de alimentación (kgs) 400 kilogramos 500 kilogramos 800 kilogramos 1100 kilogramos
Peso del equipo 7600 kilogramos 8300 kilogramos 13000 kilogramos 16500 kilogramos
Cámara primaria (litros) 2000 2400 4000 5500
Cámara secundaria (litros) 500 1200 1500 1500
Dimensiones externas (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Dimensiones internas (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Tanque de aceite (litros) 300 500 500 500
Apertura de la puerta (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimenea (M) 10 10 14 14
Tipo de chimenea Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable
Cámara secundaria
Cámara de mezcla de combustión
Cámara de filtro de humo
Combustible de combustión Gas de petróleo Gas de petróleo Gas de petróleo Gas de petróleo
Tiempo de residencia 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg.
Monitoreo de temperatura

Containerized diesel fueled incinerators

Incinerator Type: Containerized, diesel fueled
Burning Rate:100–120kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary chamber:2sec
Residue ash pot 100kg:Max 3.8kg
Incinerator type: Animal waste incinerator
Load Capacity minimum:  1500 kg
Burner fuel type:  Diesel
Burner fuel rate max.:   20-25 Liter diesel/ per hour
Burners minimum: 3
Burning rate minimum: 200-300kg/per hour
Furnace bar area minimum: 2 м3
Fuel tank capacity minimum: 300L
Main chamber burning temperature min. 1100 0C
Afterburner chamber burning temperature min.  1300 0C
Power supply 220V
Incinerator items and electrical appliances should be weather proof and humidity resistant within the range of 30-90 %
Incinerator should be compliant to the environmental protection rules in accordance to national legislation
Maximum dimensions – Length – 5m, width – 3.5m, height – 5m

Ecolead ประสบความสำเร็จในการลงนามสัญญา FFU และสัญญาตัวกรองประสิทธิภาพสูงพิเศษกับ บริษัท ย่อยการผลิตของ Zhongke Jingdian

18 พฤษภาคม 2562 ข่าว บริษัท 418 ครั้ง

สำหรับคำสั่งซื้อนี้ ลูกค้าเลือกแผ่นกรอง Ulpa ประสิทธิภาพสูงพิเศษ ( [ป้องกันอีเมล] ) พร้อมชุดกรองพัดลม (FFU) ของตัวเองเพื่อใช้ในห้องปลอดเชื้อเพื่อให้เป็นไปตามข้อกำหนดด้านคุณภาพอากาศที่ต้องการ บริษัทของเราได้รักษาความร่วมมือที่ดีกับลูกค้ารายนี้ตั้งแต่เริ่มก่อตั้ง และจัดหาอุปกรณ์ FFU ตามลำดับสำหรับการก่อสร้างโรงงาน Beijing Yangzhou Yuncheng และเพิ่มอุปกรณ์ FFU ในภายหลัง คุณภาพและการบริการของผลิตภัณฑ์ของเราได้รับความไว้วางใจและการสนับสนุนจากลูกค้า

แผ่นกรองอากาศประสิทธิภาพสูงพิเศษแบบไม่มีพาร์ติชั่นของบริษัทของเราใช้วัสดุกรองนำเข้าจากอเมริกา HV คั่นด้วยกาวร้อนละลาย และกรอบนอกเป็นอะลูมิเนียมโปรไฟล์ ผ่านการตรวจสอบและสแกนทดสอบรอยรั่วอย่างเข้มงวดก่อนบรรจุภัณฑ์ เหมาะสำหรับทุกชนิด ของห้องปลอดเชื้อ โต๊ะทำงาน สถานที่ที่ต้องควบคุมคุณภาพอากาศ เช่น โรงงานผลิตยา สถานที่วิจัยทางวิทยาศาสตร์ และการแปรรูปอาหาร

ข้อดีของผลิตภัณฑ์: 1. วัสดุกรอง HV ที่นำเข้า ทนต่อความชื้นสูง ความต้านทานต่ำ ความจุเก็บฝุ่นขนาดใหญ่

2. กรอบด้านนอกของโปรไฟล์การอัดขึ้นรูปอลูมิเนียม ด้านขาเข้าและทางออกของอากาศมีตาข่ายป้องกันโลหะสีขาว ซึ่งสามารถปกป้ององค์ประกอบตัวกรองจากความเสียหายระหว่างกระบวนการติดตั้งได้อย่างมีประสิทธิภาพ ขนาดการเปิดของโปรไฟล์คือ 50, 70 มีขนาดความหนา 90 มม. และสามขนาด

3. เทคโนโลยีการปิดผนึกแบบไร้รอยต่อดั้งเดิมประสิทธิภาพการปิดผนึกที่ยอดเยี่ยมและเอฟเฟกต์ที่ยั่งยืน

4. การตรวจสอบคุณภาพผลิตภัณฑ์ที่เข้มงวด การสแกนการตรวจจับการรั่วไหลทีละหนึ่ง ประสิทธิภาพการรวบรวมสูงถึง 99.9995%@0.12um

ต่อไปนี้เป็นรายละเอียดข้อกำหนดมาตรฐาน FFU มาตรฐาน 2*4 สำหรับการอ้างอิงของลูกค้า:

หน่วยกรองพัดลม FFU
ขนาด: 1175*575*250
วัสดุตู้: เหล็กแผ่นเคลือบสังกะสี
มอเตอร์: AC310
ความเร็วลม: ปรับได้ 0.3-0.45 ม./วินาที
แรงดันไฟฟ้า: 220V 50HZ
กำลังไฟ: 130W
ระดับเสียงรบกวน: 52dBA
HV ประสิทธิภาพสูงสุดไม่มีตัวกรองพาร์ติชั่น
ข้อกำหนดตัวกรอง: 1170*570*70
ประสิทธิภาพ: 99.9995%at0.12um
ปริมาณลม: 16CMM
การสูญเสียแรงดันเริ่มต้น: [ป้องกันอีเมล] /S
กรอบ: กรอบอลูมิเนียมอโนไดซ์
วัสดุกรอง: ใยแก้วละเอียดพิเศษ
ตาข่ายป้องกัน: ตาข่ายสเปรย์
กาว: เรซินสังเคราะห์
ปะเก็นสุญญากาศ: ยางสังเคราะห์

URL เนื้อหาเพิ่มเติม: www.ecolead.cn โทร: 025-57138032

100 Kg/Hr Incinerator for Hospital Waste

Basic Info.

Model NO.:small medical waste incinerator
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. 

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. *according to order 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane for Intelligent operation. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown area. Presently, incinerator line products market cover former Soviet Union area, Africa countries, Asia countries and Middle East area. 
From year 2010, we negotiated with updated technology from Europe and America manufacturers and establish cooperation relationship in the territory of China market. Small incinerators, waste incinerator, animal incinerators for sale, clover incinerator limited, incinerator 500kg per, incinerator china manufacturer, Unfortunately, competition in other countries market, country discrimination and worries of intellectual property rights cause failure finally. Presently, we investment more effort, funds and technology development in our own brand, we are to be one of the largest incineration equipment in the world. We have trading branch company for professional export business service.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm