Archive: December 7, 2022

health care risk waste and general waste incinerator

We strive for a sustainable development therefore we are adopting a sustainable medical waste management system, which includes building a modern sustainable incinerator that will not only cater for our facility but also for the other facilities in the larger area of the region. We are aware that we need a  modern incinerator that will not burden the local people or the local environment even more. There are several different types of incinerators available (especially recommended to be built with local materials), which are cheap to build but are more harmful to people and environment.slaughterhouse in Afghanistan in ministry of agriculture. Each plant has capacity of 100 cattle and 500 sheep per day.burn dead chicken of weight 50 kg.4.Waste  type :   health care risk waste and general waste
5. Chimney stack:
Chimney : 3.5mm mild steel
Height from base :11m and if there are buildings within
30m of the incinerator, chimney must extend at least 3m
above the apexes of all the roof of such buildings
Diameter of chimney at top :430mm
Weight of stack:  ±500 Kg
Case and stack be painted with 400⁰C heat resistant Black paint
6.Burners:
1st  chamber 850⁰C  – 900⁰C
2nd  chamber 1000⁰C
7.Variable speed combustion air blowers
8.Primary chamber volume  ±1.05 cubic metres
9.Mixing chamber volume  ±0.30 cubic metres
10.Settling chamber volume ±0.89 cubic metres
11.Weight excluding chimney  ±6.400Kg at manufacture
12..Firing tools supplied :Hoe ,poker and rake
13.Dimensions
Length                   ±2125mm
Width                    ±1890mm
Height                   ±2125mm
Extra width for burners ± 1000mm
14.Loading door opening 610 *540mm
15.Hearth area  ±1.19square metres
16.Description of grate/hearth :A full hearth to be supplied to prevent contaminated
17.Liquids from flowing into ash pit without being incinerated
18.Compliance with South African Atmospheric Pollution Prevention Act No.45 of
1965 or equivalent air pollution standards
19.Documents to be supplied :Operations and maintenance manual and standard
operating procedures (SOPs)
20. Emission controls:
heated refractory screen
Low velocity grit settling chamber
Stainless steel arrester screen

21.Refractory material :alumina content> 49% and thickness average 102mm
22.Bake out : to be done over 2-3 days
23.Materials of constructions
Case :5mm mild steel
Bracing: heavy angle and channel
Hearth: 1550 ⁰C
Ashing door: high grade cast iron
Loading door 5mm mild steel lined with 1550 ⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Incinerator walls and roof: 1550 ⁰C castable monolithic refractory

hospital incinerator

NB.: Civil works and some other relevant services for the installation and training of operators must be included in the incinerator’s cost.
22. Process Filtering system: Scruber to be mentionned as discretionary
23.
25. The technical training of operators will have to be supplied and given by a technician from
Specification for the shelter of the incinerator: House of the incinerator inclusive in offer (the house should have facilities for hand washing and firefighting).
* A timer with adjustable temporization for the regulation of each burner.
This material and equipment must include in the shed of the incinerator: foundation in rubble stone, isolation roofing against humudity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel framework (charpente en metal); roofing in sheet B.C.A. 28 BG (Toiture en t?le),metal gutter, sanitary installation (wash basin, soakway pit of 20 m of depth); ash pit of 30 m3,electrical installation; concrete slab for fixing the incinerator; chanel for evacuation of rain water or waste water, wire mesh for aeration up the lintel; smooth rougtcasting of walls (interior and outside);plinth with cement; two metal doors;email paintings inside and latex paintings outside the house on walls and on doors; roofing limit (planche de rive); steps for this specification will depend on the size of the incinerator which will determine the size of the shed of this incinerator., respectively

* A switch circuit breaker for each engine (ventilators and burners).
* A regulator with electronic viewing for the temperature of combustion.
* Electro-ventilator dispersing the secondary atmosphere, the regulation of the air flow being carried out by valves and adhering to the control of the automatic cycle.
* A secondary shot of air to ensure perfect oxygen content.

* Burner with fuel, mono-bloc casting directing type with flat flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
23. Capacity to treat Plastic: Not less than 40% by weight
19.     A control box ensuring the whole cycle of combustion. Fan:
* A regulator with electronic viewing for the temperature of postcombustion.

21. The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing.
22. Process Filtering system : Scruber to be mentionned as optional
23. Emission Standards Compliance: BS 3316 or équivalent standard
23. Capacity to treat Plastic: Not less than 40% by weight
24. CE Manufacturing Compliance: BS EN 746-2-1997
22.    The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
23.    The installed incinerator must bear a one year guarantee.
24.    The supplier shall perforn an onsite installation of the incinerator.
25. The technical training of operators will have to be provided and given by a technician from
the factory; it will consist of curative and preventive maintenance, and the use of machine, etc

NB.: Civil works and any other related services for the installation and training of operators must be included in the incinerator’s price.
Specification for the shelter of the incinerator: House of the incinerator inclusive in offer (the house must have facilities for hand washing and firefighting).
This material and equipment must include in the shed of the incinerator: foundation in rubble stone, isolation roofing against humudity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel frame (charpente en metal); roofing in sheet B.C.A. 28 BG (Toiture en t?le),metal gutter, sanitary installation (wash basin, soakway pit of 20 m of depth); ash pit of 30 m3,electrical installation; concrete slab for fixing the incinerator; chanel for evacuation of rain water or waste water, wire mesh for aeration up the lintel; smooth rougtcasting of walls (interior and outside);plinth with cement; 2 metal doors ;email paintings inside and latex paintings outside the house on walls and on doors; roofing limit (planche de rive); measures for this specification will depend on the size of the incinerator which will determine the size of the shed of the incinerator., etc

Taux de combustion de grande taille: 150-200 kg / hr Clé pour dispositifs de déchets solides et incinérateur à chambre de combustion secondaire

Articles / modèle

TS500 (API)

photo

Concept

Traitement d’incinération des déchets

Taux de brûlure

150-200 kg / heure

Mode de contrôle

PLC (Incinérateur à contrôleur logique programmable)

Chambre de combustion

2700 L

Mesures internes

190x120x120cm

Deuxième chambre

1300 L

Chambre de filtre à fumée

Oui

Réglage de l’alimentation

Manuel

Tension

220V

Consommation d’huile (kg / heure)

Typique 28

Consommation de gaz (m3 / heure)

***

Affichage de la température

Spectacle numérique

Défense de la température

Oui

Cuve à mazout

1400 L

Porte d’alimentation

90x80cm

Cheminée

10 mètres

Type d’arbre de fumée

Acier inoxydable

1er.

Poids brut

15 000 kg

Mesures extérieures

400x210x300cm (sans cheminée)

21/03/2020

L’approvisionnement en air doit être contrôlé efficacement;
Le contact de la flamme avec tous les gaz doit être réalisé;
La température de combustion minimale de la chambre primaire ne doit pas être inférieure à 850 ° C;
La chambre de combustion primaire doit être équipée d’un moyen pour fournir une alimentation supplémentaire en carburant liquide.
La chambre primaire doit être un revêtement réfractaire à face froide, d’une épaisseur minimale de 100 mm.
Les conditions suivantes doivent être remplies dans la chambre de combustion secondaire:
L’approvisionnement en air doit être contrôlé efficacement;
Le contact de la flamme avec tous les gaz doit être réalisé;
La taille de la chambre secondaire doit être correctement conçue pour garantir que le temps de rétention du gaz ne soit pas inférieur à 2 secondes;
La chambre secondaire doit être un revêtement réfractaire à face froide, d’une épaisseur minimale de 100 mm;
La chambre doit comprendre des ventilateurs d’air de brûleur de combustion intégrés avec une distribution à commande automatique;
La température du gaz, mesurée contre la paroi intérieure de la chambre secondaire (pas dans la zone de flamme) ne doit pas être inférieure à 1 100 ° C;
HICLOVER – Environnement médical  

Incinérateurs de déchets
Incinérateur de déchets médicaux
Crémation d’animaux de compagnie
Déchets solides   Incinérateur

Tél: + 86-25-8461 0201
Mobile: + 86-13813931455 (whatsapp / wechat)
Site Web: www.hiclover.com
E-mail: [email protected]
E-mail: [email protected]
Nanjing Clover Medical Technology Co., Ltd.

21/03/2020

中效/亞高效V型過濾器

2019年05月13日 空氣過濾器 357 views

Ecolead中效/亞高效V型過濾器

產品特性:

l   外框:塑框、鍍鋅框、鋁合金框

l   濾料:玻璃纖維或聚丙烯

l   最高溫度:80℃

l  最高濕度:99%

l   效率:≥80%@1um(F8)≥95%@0.3um(H10)(EN779)

產品應用:

l   主要用於空調系統的中級過濾及高級過濾

l   高效過濾器的前段過濾 

初阻力-風量關係曲線圖

常用規格及性能參數

1、若遇規格、結構變更,以本公司提供的最新數據為準

2、本公司接受非表上規格過濾網產品的訂貨

更多內容 網址: www.ecolead.cn 電話: 025-57138032

2 Chamber Medical Waste Incinerator

Product Description

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of website, like hospital, environmental division, animal cremation services, etc… Animals squander medical waste china, aravali incinerator of 30 kg per hour capacity cost, bahrain, pet incinerator, batch incinerator in china, batch load crematory, 

CLOVER Incinerator supply updated versions with dual combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Disposal of biohazard waste


Nanjing Clover Medical Innovation Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and among the biggest merchant of China. Pyrolytic burner devices technological is primary waste treatment all of the globe, for Clinical waste, Family pet animal cremation and various other Strong waste. The capability from 10kgs/Hr. to 500kgs/Hr., up to 6ton daily. Presently, we provide different collection for regional customer demands and layout updated burner with our leading innovation. The updated design feature of our range of incinerators make them among the most inexpensive worldwide.
* according to buy * High temperature level, lengthy lifetime of burner. * according to buy * New Design for family pet animal cremation service. * One year guarantee on incinerator and components in supply.

#gallery -1

#gallery -1. gallery-item

#gallery -1 img
border: 2px solid #cfcfcf;.

#gallery -1. gallery-caption
margin-left: 0;.

/ * see gallery_shortcode() in wp-includes/media. php */.

.


100-150kgs Burning rate with Secondary burning to be use in the hospital

Oil tank with 2000Liters capacity

Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 100-150 kg/hour

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (Liter/hour)

Average 14(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

medical incinerators

18.     A room of post combustion of gases
* A burner of combustion of gases,

?    
?     Nature: 65% of Al203
* A device of air inlet of cooling of waste gases,
?     . Nature: 42 percent of Al203
?    
* Carcass in solid sheet steel with support of connection.
* A device of injection of air allowing a Whole recombustion of gases,
High content of aluminum and insulates bricks to be able to assure a minimum temperature on
Refractory concrete :
* A sheath of evacuation of the gases burnt.
?     Refractory concrete :
?     Thickness    : ≥150 mm
?     . Thickness    : ≥100 mm
* Burner of light of waste, with gas, regular mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
The exterior sheet metal.

18.    A chamber of post combustion of gases
* A burner of combustion of gases,
* A device of injection of air allowing a total recombustion of gases,
* A device of air inlet of cooling of waste gases,
* A sheath of evacuation of the gases burnt.
* Carcass in strong sheet steel with support of connection.
* Composition of the refractory;
?    Refractory concrete :
?    Thickness    : ≥150 mm
?    Nature: 65% of Al203
?    Insulate in fibrous panel :
?    Thickness: ≥85 mm
?     Nature: Calcium

Новая мусоросжигательная установка для Макао »

Новая мусоросжигательная установка для Макао.

Предметы / Модель TS50 (ПЛК)
Скорость сжигания 50 кг / час
Емкость подачи 100кг
Режим управления ПЛК
Камера сгорания 560 л
Внутренние размеры 100x80x70 см
Вторичная камера 280L
Камера дымового фильтра да
Режим подачи Руководство по эксплуатации
Напряжение 220В
Мощность 0,7 кВт
Расход масла (кг / час) 12.1–24
Расход газа (м3 / час) 9,9–26,1
Монитор температуры да
Температурная защита да
Масляный бак 100л
Дверца подачи 70×55см
Камин 5 метров
Тип дымохода Нержавеющая сталь
1-й. Температура камеры 800 ℃ –1000 ℃
2-й. Температура камеры 1000 ℃ -1200 ℃
Время проживания 2.0 сек.
Вес брутто 4500кг
Внешние размеры 230x130x155 см

Dimension de l'outil : Prix de combustion : Brûleur pyrolytique à double chambre 60-80 kg / h

Articles / modèle

TS100 (API)

Image

Concept

Traitement d’incinération des déchets

Taux de brûlure

60-80 kg / heure

Réglage de contrôle

PLC (brûleur de contrôleur de raisonnement programmable)

Chambre brûlante

1200 L

Dimensions internes

120x100x100 cm

Chambre supplémentaire

600 L

Chambre de filtre à fumée

Oui (épurateur à sec)

Mode d’alimentation

Guide

Tension

220V

Utilisation d’huile (kg / heure)

Typique 20,4

Utilisation de gaz (m3 / heure)

***

Moniteur de température

Présent numérique

Sécurité de la température

Oui

Réservoir de stockage d’huile

1100 L

Porte d’alimentation

80x60cm

Smokeshaft

10 mètres

Type de cheminée

Acier inoxydable

1er. Niveau de température de la chambre

800 ℃ –– -1000 ℃

2ème. Niveau de température de la chambre

1000 ℃ -1200 ℃

Temps de résidence

2,0 sec.

Poids brut

6000 kg

Dimensions extérieures

260x150x180cm


Le besoin concerne un incinérateur pyrolytique à double chambre. L’incinérateur doit être capable d’utiliser du diesel
carburant comme mazout supplémentaire.
Il devrait intégrer un système de contrôle de la pollution atmosphérique (APC) adapté au contrôle de base des émissions.
Les incinérateurs proposés doivent être adaptés aux conditions environnementales difficiles critiques, adaptés aux
déploiement, et différentes zones climatiques (ex: désert, pays tropical, montagne, etc.) dans lesquelles il y a plusieurs
variations des forces naturelles relatives (par exemple température, humidité, vent, etc.) pendant une période minimale de 10 ans
si le calendrier de maintenance spécifié est respecté.
Les incinérateurs doivent être fournis assemblés, dans la mesure du possible, et toutes les pièces et composants doivent être
emballés sur des palettes pour être transportés par route, par air (par hélicoptère ou par fret aérien, par exemple MI8 ou C130)
et par voie maritime dans des conteneurs maritimes ISO de 20 pieds.
HICLOVER – Environnement médical  

Incinérateurs de déchets
Incinérateur de déchets médicaux
Crémation d’animaux de compagnie
Déchets solides   Incinérateur

Tél: + 86-25-8461 0201
Mobile: + 86-13813931455 (whatsapp / wechat)
Site Web: www.hiclover.com
E-mail: [email protected]
E-mail: [email protected]
Nanjing Clover Medical Technology Co., Ltd.

21/03/2020